| 1 | Taking down carefully aluminium point wiring (light, fan, socket, bell or power) complete incl all fittings and fixtures, removing, mtrls from site and making good disturbed surfaces of wall, ceilings etc., all as specified and directed. |
| 2 | M & L for surface point wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including FRLS PVC Conduit mediumgrade or PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one Exhaust /fan point or one call bell point controlled by one way switchincl necessarycutting of chases in wall/ceilingfor replacement of Modular metal flush box or filling extra hole with white cement/Putty & making good to wallas,floors etc complete all as specified and directed . |
| 3 | All as per item No. 2.00 above,but for one 5 amps socket point independent |
| 4 | All as per item No. 2.00 above, but for one 5 amps socket point in same board |
| 5 | All as per item No. 2.00 above, but for one 15 amps socket point independentwith 2.5 sqmm cable and 2.5 sqmm earth wire |
| 6 | M & L for submainwiringwith 2 x 2.5 sqmm (Nominal area) single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cabledrawn through in and including FRLS PVC Conduit mediumgrade with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dollyincl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. Note : (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. (b)working height upto roof level of wksp buildings for item No- 6 only. |
| 7 | All as per item No. 6.00 above, but cable of size 2 x 6.0 sqmm and earth wire 1 x 6 sqmm. |
| 8 | All as per item No. 6.00 above,but cable of size 4 x 10.0 sqmm and earth wire 1 x 10 sqmm . |
| 9 | All as per item No. 6.00 above, but cable of size 4 x 16.0 sqmm and earth wire1 x 16 sqmm. |
| 10 | S&F Modular switch 6Amps, 1 way, 1module, 230V all as specified and directed. |
| 11 | S&F Modular Blank plate, 1module, 230V all as specified and directed. |
| 12 | S&F Modular switch 16Amps, 1 way, 1module, 230V all as specified and directed. |
| 13 | S&F Modular Bell push 6Amps, 1 way, 1module, 230V all as specified and directed. |
| 14 | S&F Modular socket 6Amps-2/3 pin combined, 2 module, 230V all as specified and directed. |
| 15 | S&F Modular socket 6/16 Amps-2/3 pin combined, 2 module, 230V all as specified and directed. |
| 16 | S&F Modular fan regulator, stepped type, 2 module, 230V all as specified and directed. |
| 17 | S&Fceiling rose surface Bakelite three terminal incl dismentling taking down unsv oneall as specified and as directed. |
| 18 | S&Fbell electric AC 240 volt, 50 HZ. incl dismentling taking down unsv oneall as specified and as directed. |
| 19 | S&F Modular white cover plate with frame 2 Module all as specified and directed. |
| 20 | S&F Modular white cover plate with frame 3 Module all as specified and directed. |
| 21 | S&F Modular white cover plate with frame 6 Module all as specified and directed. |
| 22 | S&F Modular white cover plate with frame 8 Module all as specified and directed. |
| 23 | S&F Modular white cover plate with frame 12 Module all as specified and directed. |
| 24 | S&F Modular white PVC Box 2 Module all as specified and directed. |
| 25 | S&F Modular white PVC Box 3 Module all as specified and directed. |
| 26 | S&F Modular white PVC Box 6 Module all as specified and directed. |
| 27 | S&F Modular white PVC Box 8 Module all as specified and directed. |
| 28 | S&F Modular white PVC Box 12 Module all as specified and directed. |
| 29 | S&FHylam Sheet 3mm thick on existing concealled MS/CI ractangular or Square or round box with 04 nos cadmium coated screws and cup washer incl cutting slots for mounting switch/socket/fan regulator/ batten holder etc incl dismantling taking down unsv one all as specified and directed. |
| 30 | S&FPVC rectangular switch board of size 200mmx 150mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismantling taking down unsv oneall as specified and directed. |
| 31 | S&FMCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv oneall as specified and directed. |
| 32 | S&FMCB, Double Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv oneall as specified and directed. |
| 33 | S&FMCB, three Pole, 40 to 63 amps, 415 Voltsincl dismentling taking down unsv oneall as specified and directed. |
| 34 | S&FMCB, Four Pole, 40 to 63 amps, 415 Voltsincl dismentling taking down unsv oneall as specified and directed. |
| 35 | S&FMCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismantling taking down unsv one all as specified and directed. |
| 36 | S&FMCB distribution board, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismantling taking down unsv oneall as specified and directed. |
| 37 | S&FVertical MCB distribution board suitable for MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv oneall as specified and directed. |
| 38 | S&FVertical MCB distribution board suitable for MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 8 way incl dismentling taking down unsv oneall as specified and directed. |
| 39 | S&F MCCB, 25KA, 4 pole, with thermal magnetic trip unit, rated current 125amps complete with spider link incl dismentling taking down unsv oneall as specified and directed (Suitable for MCCB incomer DB) all as specified and directed. |
| 40 | S&FMetal plug and socket board with MCB SP 20 amp, 16 KA incl dismentling taking down unsv oneall as specified and directed. |
| 41 | S&F Metal Plug 20amps, 2 pole, 230V all as specified and directed. |
| 42 | Supply & FixLED Tube light baten, 20 watt, Aluminium housing, 230 Volts, 4 feet long , complete with all accssories internally pre wiredincl dismantling taking down unsv FTL/CFL fiitings all as specified and directed. |
| 43 | Supply & Fix Square shaped recess mounted LED slim panel down lighter, 18 watt (1`x1`), to POP/grid celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cableincl dismantling taking down unsv FTL/CFL fiitingsany type all as specified and directed. |
| 44 | Fixing only Square shaped recess mounted LED slim panel down lighter, 36/40 watt (2`x2`), to POP/grid celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cableincl dismantling taking down unsv FTL/CFL fiitingsany type all as specified and directed.Note :- LED fitting will be issued under Sch B free for fixing only. |
| 45 | Fixing only LED high bay light of any wattageat roof truss level of wksp buildings and other places incl dismantling taking down unsv one any typeall as specified and directed.Note :- LED fitting will be issued under Sch B free for fixing only. |
| 46 | S&F LED recessed round or square polycarbonate housing down lighter with superior light output and integral driver , 12 watt, warm white, complete with fixing spring clip 2 nos, fixed flush togypsum/grid ceilingincl dismantling taking down unsv one any type all as specified and directed. |
| 47 | S&F LED COB light 4 watt, WW, polycarbonate housing down lighter with targeted beams with superior lightcomplete with fixing spring clip 2 nos, fixed flush togypsum/grid ceiling suitable for existing cut out diaincl dismantling taking down unsv one any type all as specified and directed. |
| 48 | S&F LED wall Spot light 9 watt, WW, polycarbonate housing , targeted beams with superior lightcomplete with fixingarrangement incl dismantling taking down unsv one any type all as specified and directed. |
| 49 | Fixing only LED recessed (4\"x1\") polycarbonate housing down lighter with superior light output and integral driver , 40 watt complete with fixing spring clip 4 nos, fixed flush togypsum/grid ceilingincl dismantling taking down unsv one any type all as specified and directed.Note :- LED fitting will be issued under Sch B free for fixing only. |
| 50 | S&F LED flame proof high bay light fittings 150 watt, IP-65, 230V,including necessary connection with suitable size of wire complete all as specified and directed. |
| 51 | S&F LED flame proof batten suitable includingtwin T-8 tube rod of 20 watt, IP-65, 230V,including necessary connection with suitable size of wire complete all as specified and directed. |
| 52 | Supply & fix LED building security light 90 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable incl One GI medium grade 20mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismantling taking down unsv fitting any type all as specified and directed. |
| 53 | S&F LED engagement light Red & Green including dismantling taking down unsv one all as specified and directed |
| 54 | Taking down and Refixing of loose conduit/casing capping/ cable /wiring of size upto 25sqmm all as specified and as directed |
| 55 | Dismantling and refixing Aluminium strip 25 x 3.15 mm laid in trench/ roof/ wall for earthing connection for various machines/ other incl dismantling taking down unsv strip all as specified and directed. |
| 56 | Attending day to day complaint of No-light, circuit fault, non-functional of fan/light/switch/socket/regulator, frequent tripping of MCBs, realingnment/refixing of loose conduit/casing capping upto 5 mtr by providing suitable Electrician daily all as specified and directed. Note: Work to be measured as unit specified. Contractor shall not claim for outsourcing. Work is to be carried out till rectification. Any material as in this schedule shall be measured as applicable. Required screws, shadles, nuts, bolts, insulation tapes shall be provided by the contractor. Complaint shall be collected from Online complaint cell and to be rectified within 2 hours else recovery shall be made double the quotaed rate. |
| 57 | S&Ffor rolled mild steel plain or chequered plates confirming to Fe-290, Gde E-165 welded, riveted, bolted attached to supporting structure of capstan, duct covers, valve pit access platform and working in a confined area including making good the disturbed portion and dismantling old structureof concrete surfaces with 1: 1 1/2 :3 type A0 using 12.5 mm stone aggregatewith handle for lifting includingtwo coats of synthetic enamel paint over a coat of zinc chrome primer all as complete specified and directed. |
| 58 | S&F on wall/pole timer enclosure panel complete with timer analog time switches heavy duty of 230V, 50Hz, power contactor 3Phase MNX 15, 415V, 63 amps, 100A MCCB TPN, 16KA, with rotary switch with connector for incoming and outgoing cable incl removing the old one from existing site complete all as specified and directed. |
| 59 | Supply &fix, install, testing and commissioning of LTPanel factory fabricated compact size, indoor type cubical shape,three phase, 4 wire, copper bus bar for phases 400 Amps and neutral 250 Amps made out of CRCA sheet ,2 mm thick ,factory fabricated , CPRI approved , Pure Polyester Powder coated ,dust and vermin proof , provn for ventilation , fixed on wall properly with anchor fastner and of suitable compact size to accomodate the items mentioned belowand having seperate compartment /chambers for cable gallery busbar,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc and supporting angle iron\"C\" channel of suitable frame complete all as specified and directed. |
| 60 | (a) MCCB,4 pole,400 Amps with breaking capacity 25 KA -01 No (Incoming) (b) MCCB, 3 pole, 160 Amps with breaking capacity25 KA-01 Nos (Outgoing) (c) MCCB, 3 pole, 125 Amps with breaking capacity16 KA -05 Nos (Outgoing) (d) MCCB, 3 pole, 100 Amps with breaking capacity16 KA-06 Nos (Outgoing)(e) Phase indicating lamps in red/blue/yellow colours \"LED type\" - 03 Nos(f)Digital multimeter showing voltmeter, Ammeter, frequency, PF, KWH - 01 SetNote:- Rates for Excavation, PCC for foundation (Civil wk), cable glands, Cu/Al lugs for cable and other work if reqd for installation shall be deemed in contractor quoted rates. |