| 1 | Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete includingfitting such as switch, sockets, ceiling rose, pendants socket, fan regulators any type, rectangular board, light fittings, terminal boxes etc removing materialsfor taking credit and making good disturbed surfaces of walls floors and ceiling complete all as specified and directed. |
| 2 | M&L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, including metal flush box of 1.60 mm thick suitable for modular switches/ sockets/fan regulators including modular white cover plate and modular metal flush box with frame of required modules at site, blanking plates,brass screws, cup washers etc including all cutting / chases etc in stone/ brick masonary/ walls, pinning in stone walls / brick walls and pointing in cement mortar 1:3 to ends or edges of landing etc for concealed conduit wiring using heavy duty stone drilling/cutter machine and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings:- |
| 3 | One light point controlled by one, one way switch 06 mps |
| 4 | One ceiling fan point controlled by one, one way switch 06 Amps |
| 5 | One exhaust fan point controlled by one, one way switch 06 Amps |
| 6 | One 3/5 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch |
| 7 | One 3/5 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch |
| 8 | One bell Pointcontrolled by one push button 6 Amps switchon independent board |
| 9 | All as per Sl Item No 2.00 here-in-before but point wiring with 2.5 Sqmm single core FRLSH cables and earth continuity wire of 2.5 Sq mm single core FRLSH cable for one 3/6 pin 16 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed. |
| 10 | S&F Modular switch, 10 Amps, single pole, one way, 230 volts, one module complete all as specified and directed. |
| 11 | S&F Modular switch, 16 Amps, single pole, one way, 230 volts complete all as specified and directed. |
| 12 | S&F Modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified and directed. |
| 13 | S&F Modular socket outlet 02 in 01, 3/6 pin,16 Amps, 02 module with shutter complete all as specified and directed. |
| 14 | S&F Modular Bell push 6 Amps, one module 240 volts complete all as specified and directed. |
| 15 | M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC casing capping / surface conduit of 20mm dia or higher, medium grade as per site requirement complete with all casing caping/PVC conduit accessories, incl metal flush box of 1.60 mm thick fabricated CI/MS sheet terminal box covered with 3mm thick bakelite sheet top cover for housing switches, sockets, regulators etc including all cutting / chases etc in stone/ brick masonary/ walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- |
| 16 | One light point controlled by one, one way switch 06 Amps |
| 17 | One ceiling fan point controlled by one, one way switch 06 Amps |
| 18 | One exhaust fan point controlled by one, one way switch 06 Amps |
| 19 | One 3/5 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch |
| 20 | One 3/5 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch |
| 21 | One light point controlled by two 2-way switches |
| 22 | One bell point controlled by one push button 5 Amps switchon independent board |
| 23 | All Sl Item No 15.00 here-n-before but point wiring with 2.5 Sqmm single core FRLSH cables and earth continuity wire of 2.5 Sq mm single core FRLSH cable for one 3/6 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed. |
| 24 | S&F Switch piano flush type 5/6 Amps single pole one way complete all as specified and directed. |
| 25 | S&F Socket outlet 2 in 1, 5 pin, 5 Ampsflush type complete all as specified and directed. |
| 26 | S&F Switch piano flush type 15/16 Amps, single pole one way complete all as specified and directed. |
| 27 | S&F Socket outlet 2 in 13/6 pin 5 and 15 Amp flush typecomplete all as specified and directed. |
| 28 | S&F ceiling rose, 65 x 50 mm surface type with 3 terminals incl connection complete all as specified and directed. |
| 29 | S&F Ding Dong Bell, AC, 230 volts, Single Pole incl connection complete all as specified and directed. |
| 30 | S&F Switch piano flush type 5/6 Amps single pole two way complete all as specified and directed. |
| 31 | S&F Electronic ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, hum free, AC, 230 volts, 100 watts complete all as specified & directed |
| 32 | Taking down old light fitting any type and re-fixing at desired location after rewiring incl connection complete all as specified and directed. |
| 33 | S&F on surface/wall mountedLED batten, 20 watt, 230 V, AC, 4 feet, white / warm white, robust extruded aluminium housing, decorative box type with intigrated electronic drive & accessories including connection complete including taking down old/unsv light fitting complete all as specified and directed. |
| 34 | S&F Surface/wall mountedLED batten, 10 watt, 230 V, AC, 2 feet, white / warm white, decorative box type with intigrated electronic drive & accessories including connection complete including taking down old/unsv light fitting complete all as specified and directed. |
| 35 | S&F in replacement LED wall mounting mirror type, white/ warm white wall light / picture light fitting with high out put diffuser 10 watt, 220 V, AC, decorative type with driver holder and LED lamp (as per sample) including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. |
| 36 | S&F in replacement LED wall light fitting, decorative type, STYLO wall mounting, champagne gold / black finish fixture with plastic body as per sample suitable for 9/12 W LED lamp B22 base with driver holder with lamp white / warm white incl connection complete all as specified and directed. |
| 37 | S&F in replacement LED decorative down light fitting/recess mounted, round type, white/ warm white, high out put diffuser, 220 V, AC, with driver holder and LED lamp including connectioncomplete all as directed for the following wattages :- |
| 38 | 6/8 watt |
| 39 | 12 watt |
| 40 | S&F in replacement air surface/ceiling recessed mounted LED panel type of size 2 ft x 2 ft, 36 W, 230 V, white / warm white type complete with driver full window glarefree opal diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling complete all as directed |
| 41 | S&F in replacement of exhaust fan, steel body, AC single phase, 230 V of size 300mm sweep with, blades, and frame and louvers shutters along with all electrical wire connection incl taking down old fan & depositing to MES store complete all as specified and directed for the following sizes :-(Note :- Old/unsv fan shall be deposited at MES store) |
| 42 | 300 mm sweep |
| 43 | 380mm sweep |
| 44 | 450mm sweep |
| 45 | S&F Ceiling fan complete with three blades, down rod, accessories230 V, 1200 mm sweep, min air delivery 210 CFM, BEE 5 star rated with Brushless Direct Current (BLDC) motor incl connection including taking down old/unsv/faulty fan any sweep and depositing to MES store yard complete all as specified & directed .(Note: Old/unsv fan shall be deposited in MES store)(Make - Havells Model Enticer Prime BLDC (Colour Pearl White Chromear) or Atomberg Model No ERICA (Colour Snow white Matte finish) or Usha (Hi-Trend series fans) Model - Striker Platinum TM) |
| 46 | S&F in replacement fresh air ventilating fan 230/250 mm sweep, 230V, AC, sturdy engineering plastic body with louver shutter etc complete and connection from ceiling rose to fan terminal complete all as specified & directed . |
| 47 | S&F in replacement of LED lamp, inverter type bulbs, 12 watt, BEE star rated energy efficient Retrofit bulb back up time upto 04 hrs, auto cut off, 6500 K complete all as specified & directed . |
| 48 | S&F in replacement LED lamp, BEE star rated energy efficient retrofit bulb, white/ warm white, complete all as directed for following wattages :- |
| 49 | 7 Watt |
| 50 | 9 Watt |
| 51 | 12 Watt |
| 52 | 15 watt |
| 53 | 18 watt |
| 54 | S&F LED post top light, 40 watt, 230 volts, AC, outdoor type with decorative post top for 360 degree indirect light IP 65 protection, made from aluminium housing with impact and corrosion resistant with driver and lamp, fitting to be fittied & incl GI pipe of required length & size, fixed at gate/wall incl connection complete all as specified & directed. |
| 55 | S&F in replacement energy saving security light fitting of 45 watts LED pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections, fitting to be fitted on old / new GI bracket complete all as specified & directed. (Note- New GI bracket shall be measured and paid seperately) |
| 56 | S&F security light mounting bracket made out of 40 mm bore light grade GI tube of suitable length, bend to shape and fixed to wall / pole by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed. |
| 57 | Taking down exhaust fan any make/size from wall carefully, cleaning to remove any type of sticky dust with cleaning material as required and re-fixing in its original position with necessary connection after repairing, greasing, oiling, replacement of minor items such as pins, nut bolts, flexible wire etc complete all as specified and directed. |
| 58 | M&L for sub main wiring with 2.5 Sqmm nominal cross sectional area, two single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit not less than of 20mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases, pinning etc in stone/ brick masonary/ walls and making good to the disturbed surfaces to match the existing complete all specified & directed.(Note : One run of earth continuity conductor, one run of PVC Conduit concealed in wall and two runs of copper conductor together shall be taken as one length for measuring unit length) |
| 59 | All as per Sl Item No 35.00 here-in-before but for 02 x 4.0 Sqmm for phase & neutral and 01 x 4.0 Sqmm for continuous earth wire. |
| 60 | All as per Sl Item No 35.00 here-in-beforebut for 02 x 6.0 Sqmm for phase & neutral and 01 x 6.0 Sqmm for continuous earth wire |
| 61 | All as per Sl Item No 35.00 here-in-beforebut for 02 x 10.0 Sqmm for phase & neutral and 01 x 10.0 Sqmm for continuous earth wire |
| 62 | All as per Sl Item No 35.00 here-in-before but for 04 x 10.0 Sqmm for 3 phase & neutral and 01 x 10.0 Sqmm for continuous earth wire in 32 mm PVC conduit.(Note : One run of earth continuity conductor, one run of PVC Conduitand four run of copper conductor together shall be taken as one length for measuring unit length) (Note for sl item No 35.00to 39.00 above) :- Chases/ groove cutting in stone walls/ brick wall/ block masonary walls as required for concealed sub main wiring shall be measured and paid separately under relevant item no 40.00) |
| 63 | Cutting chases, pinning in Stone walls/ brick walls etc.making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings etc, for concealed conduit wiring a into or through the stone walls built in cement mortar or cement lime mortar and walls of cement concrete suitable for housing 25mm dia conduit pipe using heavy duty stone drilling/cutter machine and making good the disturbed surface all as specified and directed. |
| 64 | S&F in replacement sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 200 Amps rated copper bus bar and metal double door suitable for MCCB 63/100 amps as incomer and MCB SPs as outgoing along with cable end box for above DB and flush to wall including all cutting etc in wall complete all as specified & directed for the following ways :-(Note : MCCB & MCB SPs/SPN shall be measured and paid seperately) |
| 65 | 4 way |
| 66 | 6 way |
| 67 | S&F in replacement sheet metal enclosure, double door type for MCB TPN DB 4 way, vertical type, 415 volts with 200 Amps rated busbar and neutral link, chases wall for fixing DB and making good distributed wall surfaces to match with existing complete all as specified & directed |
| 68 | S&F in replacement Sheet metal enclosure DB, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed,double door type, IP-43,including connecting all connections of wire to MCBs with proper lugs incl chases wall for fixing DB and making good to the disturbed surface complete for the following No of ways :- |
| 69 | 4 way |
| 70 | 8 way |
| 71 | 12 way |
| 72 | S&F sheet metal enclosures with socket plug top and MCB, Single pole & neutral enclosure with a 2 pin & earth plug & socket, modular type complete with one single pole MCB 20 amps, \"C\" curve, flushed/concealed to wall incl making good the disturbed surface and connection complete all as specified & directed |
| 73 | S&F MCCB 63 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB/LT Panel & connection complete all as specified & directed |
| 74 | 63 amps |
| 75 | 100 amps |
| 76 | S&F in replacement MCB TPN, 240 Volts, AC of breaking capacity 10 KA,\"C\" curve and connections by using suitable copper lugs complete all as specified & directed of following rating :- |
| 77 | 40 amps |
| 78 | 63 amps |
| 79 | 100 amps |
| 80 | S&F in replacement MCB SPN, 240 Volts, AC of breaking capacity 10 KA,\"C\" curve and connections by using suitable copper lugs complete all as specified & directed of following rating :- |
| 81 | 40 amps |
| 82 | 63 amps |
| 83 | S&F in replacement MCB SP, 240 Volts, AC of breaking capacity 10 KA,\"C\" curve and connections by using suitable copper lugs complete all as specified & directed of following rating :- |
| 84 | 10 to 32 amps |
| 85 | 40 amps |
| 86 | S&F 1100 volt grade, heavy duty cable PVC insulated aluminium conductor, multistranded, served with inner sheathing of PVC tape and overall PVC sheathed in service/light connections suspended complete all as specified & directed. |
| 87 | 6 Sqmm, twin core, flat or circular |
| 88 | 10 Sqmm, twin core, flat or circular |
| 89 | Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed ofcomplete of following nominal cross section / sizes :- |
| 90 | 10 sqmm 2 core |
| 91 | 16 Sqmm 4 core |
| 92 | S&F for GI tubing light grade 40mm bore with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size for protection of LT UG cable complete all as specified & directed |
| 93 | M&L for Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25mtrs deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level, connected to galvanised earth lead wire 4.00 mm diaas earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point including testing on completion incl excavation and PCC work complete all as specified and directed.Note: (i) The unit rate includes 15 mm dia GI pipe up to 7.5m for protection of earth lead. (ii) The unit rate includes galvanised iron wire 4 mm dia from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance of each earthingis recorded more than 3 ohms then the earthing shall be re done by the contractor without any extra cost to the department. |