| 1 | Taking down & Dismentling defective ceiling fan from existing location of Md Accomodation and other than Md Accomodation area and dismantling of ceiling fan sweep 1200/1400 mm including fan blade, down rod, coupling, decorative caps, condenser housing, stator and rotar and replacement of defective parts complete all as specified including complete overhauling as per manufacturers instructions, reassembling and testing of 24 hrs complete and after repair refix at existing location of md accn and OTM complete all as specified and directed. Note :(i)Repair/maintenance work will be carried out at site OTM and Md Accomodation.(ii) Emergency/genuine complaint should be done by contractor within 24 hrs if not done an amount of Rs 350 will be charged from the contractor. |
| 2 | All as per Srl item No 01 here-in-before but Wall mounted fan of 450 mm. |
| 3 | All as per Srl item No 01 here-in-before but Exhaust fan of 230 mm (9\"\") and 300mm (12\"). |
| 4 | All as per Srl item No 01 here-in-before but Exhaust fan of 380 mm (15\") and 450 mm (18\"\"). |
| 5 | Taking out the old burnt out winding from the fan, rewinding with super enameled superior quality copper conductor winding with similar gauge & size as per original incl sleeves, varnishing etc of ceiling fan 1200/1400 mm complete and repaired fan should be refixed at existing location of Md Accn/OTM after testing of 24 hrs complete all as specified and directed. |
| 6 | All as per Srl Items No 5 here-in-before but wall mounted fan 450mm. |
| 7 | All as per SrlItems No 5 here-in-before but Exhaust fan of 230 mm (9\"\"). |
| 8 | All as per Srl Items No 5 here-in-before but Exhaust fan of 300 mm (12\"\") and 380mm (15\"). |
| 9 | All as per Srl Items No 5 here-in-before but Exhaust fan of 450 mm (18\"\"). |
| 10 | S&F in repair/replacement of motor with copper winding suitable for 200 mm plasticexhaust fan/ventilating fan/Air circulating fan/Fresh Air fan including disamantiling and refitting and connection of exhaust fan complete and repaired fan should be refixed at existing location of Md Accn/OTM after testing of 24 hrs complete all as specified and directed. |
| 11 | S&F in repair/replacement of motor with copper winding suitable for 250/300 mm plasticexhaust fan/ventilating fan/Air circulating fan/Fresh Air fan including disamantiling and refitting and connection of exhaust fan complete and repaired fan should be refixed at existing location of Md Accn/OTM after testing of 24 hrs complete all as specified & directed. |
| 12 | M&LRepair of old unservicable PCB Controller complete Kit from BLDC Fan and after repair of PCB Board the repaired fan should be refixed at existing location of Md Accn/OTM after testing of 24 hrs complete all as specified and directed. |
| 13 | M&L replacement of old unservicable PCB Controller complete Kit from BLDC Fan and replaced with new Electronic PCB Controller complete Kitfor BLDC ceiling fan 1200/1400 mm complete and repaired fan should be refixed at existing location of md accn/OTM after testing of 24 hrs complete all as specified and directed. |
| 14 | M&LSprey Painting withtwo coat of painting for ceiling fans/wall mounted fan/exhaust fan completewith synthetic enamel paint by spraying including writing CA No and MES No in black paint fillingcavities with filler after cleaning all dustetc complete all as specified and directed. |
| 15 | S&F in repalcement flexible 2 core copper conductor cable of size 0.75 sqmm wire PVC insulated super conductor twin core for replacement from ceiling rose to ceiling/exhaust fan complete all as specified and directed. Makes : Havells/Anchor/Polycab/Finolex |
| 16 | S&F in repalcementcapacitor of 1.5 MFD with capacitor clamp and after repair refix at existing location of Md Accn/OTM complete all as specified and directed.Makes : EFCOS/ASIAN/Bajaj/Havells |
| 17 | S&F in repalcementcapacitor of 2.5 MFD with capacitor clamp and after repair refix at existing location of Md Accn/OTM complete all as specified and directed.Makes : EFCOS/ASIAN/Bajaj/Havells |
| 18 | S&F in repalcementcapacitor of 3.15 MFD with capacitor clamp and after repair refix at existing location of Md Accn/OTM complete all as specified and directed.d. Makes : EFCOS/ASIAN/Bajaj/Havells |
| 19 | S&F in repalcement capacitor of 4 MFD with capacitor clamp and after repair refix at existing location of Md Accn/OTM complete all as specified and directed.Makes : EFCOS/ASIAN/Bajaj/Havells |
| 20 | S&F in repalcement Ball bearing Suitable for ceiling fan of sweep (200/1400mm) 48\"duly greased packed in suitable size (6201/6202) packing and after repair refix at existing location of Md Accn/OTM complete all as specified and directed.Makes : NBC/SKF/TATA |
| 21 | S&F in repalcementof complete hanging clamps upper and lower bolt, nut, washer, split pin, rubber reel of requred size complete all as per specified and directed by Engr-in-Charge. Note : Repair/maintence work shall be carry out at siteOTM and Md Accomodation. |
| 22 | S&F in repalcement of fixing screw of fan blade and fan body of any size and after repair refix at existing location of Md Accn/OTM complete all as specified and directed. |
| 23 | S&F in repalcement shaft suitable for any type of ceiling fan including mechanical laith work etc and after repair refix at existing location of Md Accn/OTM complete all as specified and directed. |
| 24 | S&F in repalcementplastic canopy (set of 02) with screw suitable for 1200/1400mm sweep and after replace, refix at existing location of Md Accn/OTM complete all as specified and directed. |
| 25 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00with brushless direct current motor (BLDC) complete all as specified and directed. |
| 26 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00with brushless direct current motor (BLDC) complete all as specified and directed. |
| 27 | S&F Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200 mm complete all as specified and directed. |
| 28 | S&F Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250/300mm complete all as specified and directed. |
| 29 | S&F Exhaust fan, steel body AC single Phase. 230V of size 250 mm sweep with, blades, and frame and louvers complete all as specified. |
| 30 | S&F Exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 31 | S&F Exhaust fan, steel body AC single Phase. 230V of size 380mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 32 | S&F Exhaust fan, steel body AC single Phase. 230V of size 450mm sweep, heavy duty with, blades, and frame and louvers complete all as specified and directed. |
| 33 | S&F ceiling fan blade 1400 mm of Make Crompton made out of aluminium sheet 14 guage duly painted each (set of Three) and after replace refix at existing location of Md Accn/OTM complete all as specified and directed. |
| 34 | S&F ceiling fan blade 1200 mm of make \"Crompton\" made out of aluminium sheet 14 guage duly painted each (set of Three) and after replace, refix at existing location of Md Accn/OTM complete all as specified and directed. |
| 35 | S&F Exhaust fans Steel/ M S frame complete with legs (set of four) including rubber as per sample for 300 mm (12\")sweep complete including removal of old U/S frame and after replace, refix at existing location of Md Accn/OTM complete all as specified and directed. |
| 36 | S&F Exhaust fans Steel/ M S frame complete with legs (set of four) including rubber as per sample for 380 mm (15\")sweep complete including removal of old unserviceable frame and after replace, refix at existing location of Md Accn/OTM complete all as specified and directed. |
| 37 | S&FExhaust fans Steel/ M S frame complete with legs (set of four) including rubber as per sample for 450 mm (18\")sweep complete including removal of old unserviceable frame and after replace, refix at existing location of Md Accn/OTM complete all as specified and directed. |
| 38 | Taking out existing unserviceable fan motor from the Exhuast Fan of Size 300 mm and supply fixing and connecting new fan motor Suitable for 300 m Ex Fan, RPM 1400, 230 Volt 50 C/s single phase complete including MS clamps and rubber pad , Fan Blade complete all as specified and directed. |
| 39 | Taking out existing unserviceable fan motor from the Exhuast Fan of Size 380 mm and supply fixing and connecting new fan motor Suitable for 300 m Ex Fan,RPM 1400230 Volt 50 C/s single phase complete including MS clamps and rubber pad , Fan Blade complete all as specified and directed. |
| 40 | Taking out existing unserviceable fan motor from the Exhuast Fan of Size 450 mm and supply fixing and connecting new fan motor Suitable for 450 m Ex Fan,RPM 1400 & above230 Volt 50 C/s single phase complete including MS clamps and rubber pad , Fan Blade complete all as specified and directed. |
| 41 | S&F in replacement of fan blade for Exhaust fan12\" and after repair refix at existing location of Md Accn/OTM complete all as specified and directed. |
| 42 | S&F in replacement of fan blade for Exhaust fan15\" and after repair refix at existing location of Md Accn/OTM complete all as specified and directed. |
| 43 | S&F in replacement of fan blade ( consist of 4 Blades) for Exhaust fan18\" and after repair refix at existing location of Md Accn/OTM complete all as specified and directed. |
| 44 | S&F wall mounted fan of size 450 mm sweep AC single phase 230V complete all as specified and directed. Make of fan: Crompton/Bajaj/Khaitan/Havells all as direted by Engineer-in-charge . |
| 45 | S&F down rod 15mm dia of 18\"/24\" in length alongwith hole at one end and cut for hanging of fan and after replace, refix at existing location of Md Accn/OTM complete all as specified and directed. |