| 1 | Dismantling of stone slabs and tiles of land on dry of any description or thickness in floors, aprons etc complete all as specified and directed. |
| 2 | M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour red and yellow both combination, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed |
| 3 | Demolition of brick work built in cement mortar incl all quoins, arches pillars etc but excluding ashlar facings etc. |
| 4 | M&L for PCC 1:2:4 Type B0 (12.5 mm graded crushed stone aggregate) in filling under pressed steel door frame, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,bed plates copings, kneelers, kerbs etc, water troughs and the like including weathering, slightly rounded or chamfered angles and throating,complete all as directed |
| 5 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed |
| 6 | Dismantling, floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 7 | M&L for chequered cement concrete tiles, size not less than 20cm x 20cm x 25mm thick set, with grey cement and pigment, jointed and pointed in neat cement slurry in floors, path over and incl 20 mm thick screed bed in cement mortar 1:6 compltete all as specified and directed |
| 8 | Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soil and loose soil complete all as specified and directed. |
| 9 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depthforfoundation etc and getting out in soft/loose soil complete as specified and directed. |
| 10 | M & LPCC1 : 4 : 8Type D2 ( 40 mm graded aggregsate) as in foundation and mass concrete complete all as specified and directed. |
| 11 | Use and waste the form work to sides of concrete fdn, footings plinth beam etc, vertical or to batter. |
| 12 | Use and waste form work to sofit of suspended slab such as roof slabs,floor slabs ,landings and similar work ;not exceeding 200 mm thick |
| 13 | Use and waste the form work to sides of pillars, posts, struts, piers, columns, fair finished surface. |
| 14 | S & FTMT steel bars 10 mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking end and binding with and including MS wire annealed not less than 0.9 mm dia or securing with clips complete all as specified. |
| 15 | S & FTMT steelbars 6 to 8 mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking end and binding with and including MS wire annealed not less than 0.9 mm dia or with securing clips complete all as specified. |
| 16 | M&L for RCC (1:2:4)type B1 as in foundationfootings, foundation beam,plinth beams and bases of columns basement slabs, and mass concrete. |
| 17 | M&L for RCC 1:2:4 type B1as in columns pillers, piers, posts and struts complete all as specified |
| 18 | M & LRCC 1 : 2 : 4 Type B1 ( 20 MM graded aggregate) as in slabs supported on walls beam and colums in floors, roofs, landings, deck slabs and shelves and the like complete all as specified and directed. |
| 19 | M & Lbrick work with sub class \"B\" bricks straight or curved on plan exc 6 m mean radius built inCM1 : 6complete all as specified. |
| 20 | M & L for brick work with sub class \"B\" bricks straight or curved on plan to anyradius built in CM 1 : 4 in half brick thick walls complete all as specified and directed. |
| 21 | M & Lhardcore of broken bricks or bouldersn .exc15 cm thick of gauge n.exc63 mm, deposited, sprayed and levelled in layersnexc15 cm thick watered and rammed to a true surfaces. |
| 22 | M & L 75 mm thick PCC 1:4:8 Type D2 ( 40 mm graded aggregate) as in sub base to floors |
| 23 | M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles and including 15mm thick CM 1:6 complete all as specified and directed. Make Orient Bell, Kajaria, Somany |
| 24 | M&L Glazed ceramic coloured tiles in vertical surface 350x250x 7 mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchwith the shade of tiles and including 10mm thick rendering in CM 1:3 to receive wall tiles complete all as specified and directed. Make Orient Bell, Kajaria, Somany |
| 25 | S & F 25 mm dia GI tubing medium grade with all fittings and fixed complete to walls or laid in floors. Make Prakash, Jindal and Tata |
| 26 | S & F 20 mm dia GI tubing medium grade with all fittings and fixed complete to walls or laid in floors. Make Prakash, Jindal and Tata |
| 27 | S & F 15 mm dia GI tubing medium grade with all fittings and fixed complete to walls or laid in floors. Make Prakash, Jindal and Tata |
| 28 | S&F 500 litres capacity rotational moulded polythene water storage tanks (Double layer) (cylindrical vertical, with closed top), hoisted and fixed in position as specified in SSR Part I complete. Make Vectus, RC Plasto, Syntex |
| 29 | S&F 15mm bore bib taps cast copper alloy, screwed down high pressure with crutch or butterfly handle fancy type chromium plated screwed for iron pipe for brass furule and fixed complete all as specified and directed. Make Prayag, Grohe and Essco |
| 30 | S&F 15mm pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or with out lettered \"Hot\" or \"Cold\" with long screwed shanks and flynuts, screwed for iron pipe and fixed complete all as specified and directed. Make Prayag, Grohe and Essco |
| 31 | S&F 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (min weight 15mm-142 gms/20mm-210 gmsfixed to iron pipe complete all as specified and directed. Make Nirali, Prayag and Jain Brother |
| 32 | S &Fin repairs glass shelf of PTMT fixed with and including Chromium plated brass screws and wooden/ plastic cleats (min weight 300 gms) complete as specified and directed. |
| 33 | S &Fin repairs Towel rail of CP 600 mm long fixed with and including Chromium plated brass screws and wooden/ plastic cleats (min weight 190 gms) complete as specified and directed. |
| 34 | M&L PVC(SWR) floor trap ,plain with grating including jointing with solvent cement |
| 35 | S & F 110 mm dia, PVC (SWR) single socketed rain water pipe in any length with rubber ring joints fixed to walls complete all as specified and directed. Make Finolex, Astral and Prince |
| 36 | S & F 75 mm dia, PVC (SWR) single socketed rain water pipe in any length with rubber ring joints fixed to walls complete all as specified and directed. Make Finolex, Astral and Prince |
| 37 | S&F110mm bore PVC (SWR) branch pipe, single Y equal or unequal with access door complete all as specified. |
| 38 | S&F 75mm bore PVC (SWR) branch pipe, Double Y equal or unequal with access door complete all as specified and directed. |
| 39 | S&F in repair vitreous china squatting pan, Orissa pattern size 580mm x 440mm with integral foot rest including connection to trap and to flush pipe, anti-syphonage pipe etc completeall as specified and directed. Make Cera, Hindware and Parryware |
| 40 | S & F in repairs vitreous china wash hand basin, white, flat back, size 450 X 300 mm excluding taps, wash, chain and plug and procelain stopper but including brackets cutting for pinning in ends of brackets or erecting stand and waste coupling and waste pipe (half or full thread) min weight 32mm-45 Gms/40mm-60Gms) Make Cera, Hindware and Parryware |
| 41 | S & F 600 X 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromiumplated brass screws and cup washers . |
| 42 | S & F in repairs 10 litres capacity PVC valveless syphonic action type flush cistern low level white with inlet ball valve float & handle including brackets and flush pipe of polythene of low or high density 32mm dia for low level cistern complete all as specified and directed. Make Cera, Hindware and Parryware |
| 43 | S & F in repair 15mm Angle stop cock ofCP screwed for iron pipe and fixed complete all as specified and directed. Make Prayag, Essco and Grohe |
| 44 | S&F solid PVC door frames of size 50mm X 47mm made out of 5mm plain color PVC sheet reinforced with MS square tube complete all as specified & directed. Make Rajshree, Yamuna Interior or equivalent |
| 45 | S&F factory made solid panel PVC door shutter, 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded, plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom railon either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as per specification anddrawing and as directed. Make Rajshree, Yamuna Interior or equivalent |
| 46 | S & F 100mm long steel butt hings medium weight cold rolled mild steel & fixed to chowkats complete all as specified. |
| 47 | S & F 200 mm long SS barrel tower bolts complete all as specified as directed. |
| 48 | S & F 150 mm size SS handles complete all as specified as directed. |
| 49 | S & F stainless steel sliding door bolts, 300 mm long, plate type bolts not less than 12mm dia with & including a minimum of 6 boltsand nuts, four on bolt plate and two on staple plate etc complete. |
| 50 | M & L 5mm thick rendering on fair faces of brick work or concrete surface in cm 1:3 as in ceiling to be finished even and smooth with out using extra cement.Note- Rendering will be done by coarse sand only |
| 51 | M & L 10mm thick rendering on fair faces of brick work or concrete surface in cm 1:4 as in internal walls to be finished even and smooth withoutusing extra cement .Note- Rendering will be done by coarse sand only |
| 52 | M & L 15 mm thick rendering on fair faces of brick work or concrete surface as in external walls in cm 1:4 to be finished even and smooth withoutusing extra cement. Note- Rendering will be done by coarse sand only |
| 53 | M & L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 54 | M&L for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of oil bound distemper on walls over a coat of primer, complete all as specified and directed |
| 55 | M & L for preparing newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified. |
| 56 | Returning, filling in, including spreading levelling, watering and well ramming in layersnexc25 cm in soft/loose soil. |
| 57 | M & L Removing excavated material to a distance exc 50 mtr but n.exc 250 mtr but and depositing where directed at a level n exc 1.5 mtr above starting point. |
| 58 | M & L 75 mm PCC1:3:6Type C2( 40 mm graded aggregate ) as in plinth protection. |
| 59 | S&F 20mm bore Gun-metal, globe or gate valves,with iron wheel head, crewed both ends for iron pipe and fixed complete all as specified and directed. |
| 60 | Steel ventilator with top hung shutter including hinges, steel peg stay, complete |
| 61 | S & F Steel glass of ordinary quality 3.00 mm thick in panesnexc 0.5 Sqm in each pane. |
| 62 | S & F in repairsvitreous china urinal bowl type or half stall pattern white (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets flush pipe grating and union for dischargemm-45 Gms/40mm-60Gms). Make Cera, HIndware and Jaquar |
| 63 | M & L Reinforced concrete pipes 150 mm bore of pipe class NP2, laid and jointed complete with collars complete all as specifiedand directed. |
| 64 | Concrete bed to drain pipes in cement concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate including packing under and completely surrounding pipe with concrete after they arelaid jointed and tested for 150mm bore of pipe complete all as specified and directed. |
| 65 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors,and making good disturbed portion / surface of wall/ floor/ ceiling etc by using cement mortar (1:4)including white / colour wash / distempering etc as required to match with the existing surfaces / location complete all as specified and as directed. |
| 66 | Material and labour for point wiringwith 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLS PVC insulated, sheathed, copper conductor cable in and including PVC concealed conduit of not less than 20/25 mm dia complete with all accessories/fittings, brass screws, washer etc, including modular boxes, modular front cover plates & back plate suitable for fixing modular switches/sockets and including continuous earth wire ( green colour) of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated multi stranded copper conductor cable, sheathed and connected to common earth and earth duly complete all as specified and directed for the followings :- |
| 67 | All as per Srl item No. 66.00 above but for one tube light/Bulb/ Bldg security light/Fan point controlled by one, one way switch 05 / 06 Amps. |
| 68 | All as per Srl item No. 66.00but forOne socket outlet point 6 A on sameboard |
| 69 | All as per Srl item No. 66.00but for one socket outlet point 6 Amps on independent board |
| 70 | All as per Srl Item No. 66.00 here in before but concealed point wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed (FRLS) cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed (FRLS) cable, green colour as earth continuity wire. |
| 71 | S&FModular Switch, 1 module, 6A, AC, 240V, one way ISI Marked complete all as specified and directed.. |
| 72 | S&FModular Switch, 1 module, 16A, AC, 240V, one way ISI Marked complete all as specified and directed.. |
| 73 | S&FModular Socket, 2 module, 6A, 3 pin combined, AC, 240V, ISI Marked complete all as specified and directed.. |
| 74 | S&FModular Socket, 2 module, 16A, 3 pin combined, AC, 240V, ISI Marked complete all as specified and directed.. |
| 75 | Supply & fixing of ceiling rose in polycarbonate 3 terminal brass flush type 6 Amps, 250 Volts, AC supply (ISI marked), fixed on & including 3 mm thick 75mm dia sunmica hylum plastic laminated round sheetcomplete all as specified and directed. |
| 76 | Supply & Fix electronic fan regulator modular type of one module |
| 77 | Taking down unserviceable main switch, DB’s insulators, DB for MCB and board etc of any type and any capacity and further disposal including making good the disturbed surfaces in cement mortar (1:4) including applying white/colour wash / paint / distemper as required to match the existing surfaces complete all as specified and as directed. |
| 78 | Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in -charge. |
| 79 | S & F MCB SPN 32 Amps, 230 Volts \"c\" curve10 KA, including necessary connection complete all as specified and as directed. |
| 80 | Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of6 to 32 amps, 240 Volts in proper positionall as specified and as directed. |
| 81 | Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate all as specified and directed. |
| 82 | Supply and fixing LED bulb 2 pin 9/10 watt. |
| 83 | Taking down old unserviceable light fitting any type, complete all as specified. |
| 84 | Supply and fixing LED light fitting 1x22/25 watt,220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 85 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 86 | Taking down existing earthing of any description and M&L for new earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earthing wire 4mm dia size by means of GI bolts, nuts, check nuts and washers, earthing wire protected by GI pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 ofSSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) type C1 in chamber of size not less than 300x300x300mm (internal diamentions) with cover made of RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15cm C/C both ways and angle iron 40X40X5mm frame etc duly painted with two coats of synthetic enamel paint over a coat of red oxided primer on exposed surfaces complete all as specified and directed by Engineer-in-Charge.Note: The unit rate includes earthing wire and protection pipe upto maximum 7.5 metre from earth plate, earth point / test point. |
| 87 | Supply and fixing Exhaust fan with louver PVC and fixing accessories 230 Volt and250 mm sweep BEE 5 star rating . |
| 88 | supply ,laying commissioning ,testing of XLPE under ground LT cable 1100 volts grade of size 16 sqmm 2 core armoured PVC sheathed with aluminium conductor heavy duty laid in trench ,fixing on wall ,under road crossing through proctection pipe etc complete all as specified and directed. |
| 89 | M & L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness only shall be measured & Paid. |
| 90 | Supply & Laying of sub class \"B\"bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed by Engr-in-Charge. |