| 1 | Supplying of XLPE insulated & PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of size 3.5 X 35 sqmm, confirming to IS:7098 (Part- I) 1988 with up to date ammendmentas required. |
| 2 | Supplying of XLPE insulated & PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of size 4 X 25 sqmm, confirming to IS:7098 (Part- I) 1988 with up to date ammendmentas required. |
| 3 | Supplying of XLPE insulated & PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of size 4 X 10 sqmm, confirming to IS:7098 (Part- I) 1988 with up to date ammendmentas required. |
| 4 | Supplying of XLPE insulated & PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of size 2 X 10 sqmm, confirming to IS:7098 (Part- I) 1988 with up to date ammendmentas required. |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the open air along with 8 swg GI wire or as suitable for supporting the cable,etc. completeas required. Upto 95 sq. mm |
| 6 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm |
| 7 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE aluminium conductor power cable of 1.1 KV grade, of size upto 35 sq. mm (clamped with 1mm thick saddle) etc. on wall/pole surface, as required. |
| 8 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc.External work |
| 9 | 32 mm dia nominal bore |
| 10 | 40 mm dia nominal bore |
| 11 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 12 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driveras per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above90°C).150 watt |
| 13 | Supplying and fixing of outdoor type loop in loop out cable junction box fabricated from PVC/1.6 mm MS sheet enclosed weather proof, dust proof, water proof and locking arrangement internally embedded gasket with bottom cable entry plate through cable glands having seperate holes for incoming and outgoing cables and with wires fixed in it having clamps for fitting on steel structure or wall with followings in it. i) HD Connector for 10 to 16 sqmm -4 No. ii)10 to 16 amp SP \"C\" curve 10 KA MCB- 1 No. iii) fixing Clamps with nuts,bots,etc. -2 Nos. |
| 14 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz,Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC. As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electricalcircuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).45 watt |
| 15 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sinkof aluminum housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness ≥ 0.50 mm)18- 22 watt |
| 16 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 17 | Providing and Installation of floor mounted dust proof, weather proof outdoor feeder panel of minimum size 800 X 750 X 300 mm of 2mm CRCA Sheet IP 42 with seperate compartment, factory finished painting with 9tank treatment process, finishing powder coating of minmum 60 micron thickness, locking arrangement complete with internal wiring.The board includes 415 V suitable size of Aluminium bus bar, Removable gland plates, Cable glands & lugs for cables complete in all respect.The board shall be complete with 3 nos. LED phase indicating lights,flush AVF meter with CTs, PTs, selector switches,protective MCBs, Danger Notice Plate etc. with all interconnections by minimum 2.5 Sq.mm copper wire as per the requirement.Further the panel will be placed on MS frame stand as per direction from Engineer in charge. |
| 18 | The following mountings are to be fixed in the panel board. a) Incoming 100 Amp, 30 KA, MCCB 4 pole - 1 No.(Conforms to IS/IEC:60947-2) b) Outgoing:63 Amp, 10 KA, MCB 4 pole - 1 No. c) 32 Amp, 10 KA MCB DP - 2 No. d) 16 Amp, 10 KA MCB DP - 2 No. e) 16 Amp, 10 KA MCB SP - 2 No. f) CT- 3 Nosg) Ampere Meter -1 No. h) Volt Meter (0-500V)- 1 No. i) Selector Switch - 2 Nos.j) Indicator lamp with toggle switch with SP MCB set - 1 Set |
| 19 | Providing and Installation of floor mounted dust proof, weather proof outdoor feeder panel of minimum size 800 X 750 X 300 mm of 2 mm CRCA Sheet IP 42 with seperate compartment, factory finished painting with 9tank treatment process, finishing powder coating of minmum 60 micron thickness, locking arrangement complete with internal wiring.The board includes 415 V suitable size of Aluminium bus bar, Removable gland plates, Cable glands & lugs for cables complete in all respect.The board shall be complete with 3 nos. LED phase indicating lights,flush AVF meter with CTs, PTs, selector switches,protective MCBs, Danger Notice Plate etc. with all interconnections by minimum 2.5 Sq.mm copper wire as per the requirement.Further the panel will be placed on MS frame stand as per direction from Engineer in charge. |
| 20 | The following mountings are to be fixed in the panel board. a) Incoming 100 Amp, 30 KA, MCCB 4 pole - 1 No.(Conforms to IS/IEC:60947-2) b) Outgoing:63 Amp, 10 KA, MCB 4 pole - 1 No. c) 32 Amp, 10 KA MCB DP - 3 No. d) 16 Amp, 10 KA MCB SP - 2 No.e) CT- 3 Nosf) Ampere Meter -1 No. g) Volt Meter (0-500V)- 1 No. h) Selector Switch - 2 Nos.i) Indicator lamp with toggle switch with SP MCB set - 1 Set |
| 21 | Supply, Installation, testing & commissioning of cubicle type totally enclosed free standing type moisture, dust and vermin proofPanel Board made out of 2.0 mm thick CRCA sheet Steel IP 42 floor mounting type with minimum dimension of 1700 mm(H) X 1400 mm (W) X 350 mm(D) fabricated in compartmentalized design. The sheet steel shall undergo minimum 9 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes415 V electrolytic, 315/400 Amp Aluminium Bus Bar, removable gland plates, cable glands,including connection with outgoing feeders completeinall respect. All MCCB shall have thermalmagnetic release with adjustable over current,short circuit & Earth fault protection with trip history (Faulty phase, type of fault and interupted Current) . All MCCB\"s shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L &S/Ctrip setting as per load requirement. All TP MCCB shall be with solid isolable neutral link.The breaking capacity specified is Ics value. All outgoing MCB\"s shall be C type with 10 KA breaking capacity. The fault withstanding capacity of panel shall be 25 KA rms for 1 sec. The above board shall be complete with 3 nos. phase indicating lights, flush AVF meter with, CT\"s, PT\"s, selector switches, protective fuses etc. at Incomer with all inter connections by min. 2.5 sq.mm. Further the panel will be placed on MS frame stand as per direction from Engineer in charge.Copper wires alongwith switchgears as mentioned below: |
| 22 | The following mountings are to be fixed in the panel board. a) Incoming -1 No of 250 Amp FP Moulded Case Circuit Breaker. (36 KA) (Conforms to IS/IEC:60947-2)b) Outgoing: 100 A,30 KA,MCCB 4 pole - 3 No. (Conforms to IS/IEC:60947-2) c) 63 Amp, 25 KA, MCCB FP - 2 No. (Conforms to IS/IEC:60947-2) d) 16 Amp, 10 KA MCB DP - 2 No.e) CT- 3 Nosf) Ampere Meter -1 No. g) Volt Meter (0-500V)- 1 No. h) Selector Switch - 2 Nos.i) Indicator lamp with toggle switch with SP MCB set - 1 Set j) Changeover Switch 250 Amp. with rotary handle - 1 No. |
| 23 | Supply of7.5 mtr GI pipe as par IS/1239 ISI MARKED C Class (heavy) of 50 mm dia. for erecting vertically in ground in cement concrete foundation. |
| 24 | Erection of metallic pipe/pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 6.5 metre and upto 8.0 metre |
| 25 | Supply, Installation, Testing and Commissioning of 1200 mm ceiling fan,with class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, 350-400 RPM (tolerance as per IS : 374-2019) and all remaining accessories including safety pin, nut bolts, washers, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 26 | Supplying and fixing following way, single pole andneutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 27 | 6 way , Double door |
| 28 | 8 way , Double door |
| 29 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 30 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. |
| 31 | Single pole |
| 32 | Double pole |
| 33 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 34 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. |
| 35 | Supply of Exhaust fan alongwith louvers with sweep size of 250 mm, RPM 1200, 220-240 V and with air delivery capacity > 800 CMHconfirming to IS and IEC code as approved by the Engineer in charge. |
| 36 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 37 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for installation of LED light and painting with primer and finished paint as required. |
| 38 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 250 A,36KA,FP MCCB |
| 39 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 40 | Supply and fixing of 100 A, 415 V operational voltage, 50 Hz , 4 Way, weatherproof, outdoor,wall mounting type Busbar Chamber with angle stand and suitable for connection of 3 phase,4 Core Aluminium Armoured Cablesas required having removable gland plate with knock out provision and Liberal space between cable / busbar and live parts, fabricated using sheet steel (CRCA) and epoxy powder coated to give superior & lasting finish, manufacturedby CPRI approved manufacturer. |
| 41 | EarthingwithG.I.earthpipe 4.5metrelong,40mmdia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 42 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 43 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 44 | Supplying and fixing of 600 mm x 600 mm size metalic frame cover fabricated with 35 mm x 35 mm x 5 mm thick angle iron welded construction frame structured and 3 mm thick M. S. sheet cover plate with double hinges and knobe type locking arrangement including painting, making recess in wall, masonary, plastering & finishing the good |
| 45 | Credit to Estimate |
| 46 | OldLT panel, loop boxes, all electricals materials etc. |
| 47 | Dismantled RCC Poles |
| 48 | Old wire pieces, cable pices |