| 1 | Schedule A (Part-I) COB WAKKAConstruction of PUF shelter (18.30x7.60x2.7M) for 20 Men SM Bk all as per techincal speciication including plinth/foundation with vitrified tiles flooring, plinth protection, furniture and electrification all as techincal specification and Drg No DGAR/COB/01 (Sheet No 01/10 to 10/10) and directed by Engr-In-Charge. |
| 2 | Construction of Single Offr/JCO PUF shelter (7.90x10.64M) living accn incl plinth/foundation, vitrified tiles flooring, plinth protection, furniture , electrification,toilet, sanitary and water supply fitting all as per techincal specifications and drawing No DGAR/COB/03(Sheet No 01/10 to 10/10) and directed by Engr-In-Charge |
| 3 | Construction of PUF shelter (18.30x6.10M) for Kote incl plinth/foundation and flooring all as per techincal specification and Drg No DGAR/COB/04 (Sheet No 01/09 to 09/09) and directed by Engr-In-Charge. |
| 4 | Construction of PUF shelter (18.30x6.10M) for Store building incl plinth/foundation, flooring, plinth protection, furniture , electrification all as per techincal specification and drawing No. DGAR/COB/04 (Sheet No 01/09 to 09/09) and directed by Engr- In-Charge . |
| 5 | Construction of PUF shelter for Sentry post/Gd room complete all as perspecifications and drawing No. DGAR/COB/115 (Sheet No 01/04 to04/04) and directed by Engr-In-Charge. |
| 6 | Construction of PUF shelter (7.20x2.22M) for Six men toilet blockincl plinth/foundation, vitrified tiles flooring, plinth protection, minimum one EWS for each block, electrification,toilet, sanitary and water supply fitting, overhead water tank staging complete all as per specifications and drawing No. DGAR/COB/114 (Sheeet No 01/03 to 03/03) and directed by Engr-In-Charge. COB Wakka- 02 |
| 7 | Schedule A (Part-II) Construction of security fencing all as per drawing and specification and detailed estimate. Earth work excavation by mechanical means Hydaulic excavator/manual means in foundation trenches or drains (nor exceeding 30 cm in depth, 1.5m in width or 10 sqm on plan), including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed by Engineer -In- Charge. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level 1:3:6 (1 Cement : 3 Coarse sand : 6 graded stone aggregate 40mm nominal size) |
| 9 | Centering and shuttering including struting, propping etc and removal of form for walls (any thickness) including attached pilasters, plinth posts etc. |
| 10 | Supplying at site angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10mm dia etc complete 65x65x6mm angle iron post for both iron pillar and strut post. |
| 11 | Fencing with welded steel wire favric fencing with posts of specified material and standard design of size 75mmx 75mm using 4mm dia GI wire. |
| 12 | Extra for providing and fixing FI strip for barbed wire of 40x6mm flat iton section. |
| 13 | Painting with aluminum paint of approved brand and manufacture to give an even shade two or more coats on new work on chain link fencing. |
| 14 | Providing and fixing concertina coil fencing with punched tape concertinal coil 600mm dia 10 metre openable length (total length 90m) , having 50 nos rounds per 6 metre length, upto 3m height of wall with existing angle iron \"Y\" shaped placed 2.4m or 3.00m apart and with 9 Horizontal (R.B.T reinforced barbed wire, stud tied with G.I staples and G.I clips to retain horizintal, including necessary bolts or G.I barbed wire tied to angle iron all complete as per direction of Engineer- In- Charge. |
| 15 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be shuttered on both sides and end post on one side only and provided with horizontal lines and two diagnols interwoven with horizontal wires, of barbed wire weighing 9.38 Kg per 100m (minimuim), between the two posts fitted and fixed with G.I. staples, turn buckles etc complete. (Cost of posts, struts, earth work and concrete work to be paid for seperately). Payment to be made per metre cost of total length of barbed wire used. 16.18.1 with G.I barbed wire. |
| 16 | Painting with aluminium paint of approved brand and manufacture to give an even shade Two or more coats on new work on chain link fencing. |
| 17 | Schedule A (Part-III) Construction of Internal Road all as per drawing and specification and detailed estimate.Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-In-Charge. |
| 18 | Supplying and laying stone aggregate of 90 to 45 mm size. |
| 19 | Providing and lying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6(1 Cement : 3 Coarse sand : 6 graded stone aggregate 40 mm nominal size. |
| 20 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in requied colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc, all complete as per the direction of Engineer-In- Charge. |
| 21 | Schedule A (Part-IV) Construction of Retaining wall all as per drawing and specification and detailed estimateEarthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includig dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 22 | Providing and laying of position cement concrete of specified grade ecliding the cost of centering and shuttering with mix of 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) all work upto plinth level. |
| 23 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12(1 Cement : 6 coarses sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 Cement : 6 coarses sand). |
| 24 | Random rubble masonry with hard stone in Superstructure above plinth level and upto floor five level, including levelling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) above plinth level with : Cement mortar 1:6 (1 Cement : 6 coarse sand). |
| 25 | Providing and laying of cement concrete in cooping of R.R masonry retaining walls of specified grade excluding the cost of centering and shuttering with mix of 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) upto floor five level. |
| 26 | Raised and cut pointing in stone work in white cement mortar mix of 1:3 (1 cement : 3 fine sand). |
| 27 | Supplying and stacking at site 20 mm size stone aggregate. |
| 28 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. |
| 29 | Providing and laying opposition cement concrete of specified gradient excluding the cost of centenring and shuttering with mix of (1:2:4) (1 cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size) all work upto plinth level |
| 30 | Providing and laying of position cement concrete of specified grade excliding the cost of centering and shuttering with mix of 1:3:6(1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) all work upto plinth level. |
| 31 | Schedule A (Part-V) Construction of Storm Drainage all as per drawing and specification and detailed estimate.Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5 m disposal soil to be levelled and neatly dressed. All kind of soil. |
| 32 | Earth work in excavation by mechanical means (Hydraulic excavation)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m, all kind of soil. |
| 33 | Providing and laying in position cement, concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size. |
| 34 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 35 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : cement mortar 1:6 (1 cement : 6 coarse sand). |
| 36 | 12 mm cement plaster of mix 1:4 (1 cement : 4 fine sand). |
| 37 | Schedule A (Part-VI) Provision of PCC Footpath with Chequred Tiles.Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5 m disposal soil to be levelled and neatly dressed. All kind of soil. |
| 38 | Supply and lying stone aggregate of 90 to 45mm size of WBM with moroum as binding material including 13.2mm size stone screening sorting, watering spreading to template, compacting stone aggregate in uniformed thickness and consolodiation with power road roller of 8 to 10 tonne capacity in two layer with proper gradient |
| 39 | Providing and laying of position cement concrete of specified grade excliding the cost of centering and shuttering with mix of 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone agregate 20 mm nominal size) all work upto plinth level. |
| 40 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses plinth and string courses etc. |
| 41 | Chequerred precast cement concrete tiles 22mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 42 | Schedule A (Part-VII) Provision of Earthwork in excavation in over areas.Earth work in excavation by mechanical means (hydrolic excavator) manual means over area. |
| 43 | Schedule A (Part-VIII) Sewage Disposal SystemSeptic Tank 50 user all as per drawing No DGAR/Engr/355 (Sheet No 01/01) |
| 44 | Septic Tank 20 user all as per drawing No DGAR/Engr/355 (Sheet No 01/01) |
| 45 | Soak Pit all as per drawing No DGAR/Engr/356 (Sheet No 01/01) |
| 46 | Mainhole Chamber all as per drawing No DGAR/Engr/356 (Sheet No 01/01) |
| 47 | Laying of PVC sewage pipiline 110mm diameter in trenches incl earthwork execuation and filling complete |
| 48 | COB NOGLOConstruction of PUF shelter (18.30x7.60x2.7M) for 20 Men SM Bk all as per techincal speciication including plinth/foundation with vitrified tiles flooring, plinth protection, furniture and electrification all as techincal specification and Drg No DGAR/COB/01 (Sheet No 01/10 to 10/10) and directed by Engr-In-Charge. |
| 49 | Construction of Single Offr/JCO PUF shelter (7.90x10.64M) living accn incl plinth/foundation, vitrified tiles flooring, plinth protection, furniture , electrification,toilet, sanitary and water supply fitting all as per techincal specifications and drawing No DGAR/COB/03(Sheet No 01/10 to 10/10) and directed by Engr-In-Charge. |
| 50 | Construction of PUF shelter (20.88x9.10M) for CH/DH all as per techincal specification incl plinth/foundation, vitrified tiles flooring in dining hall, plinth protection, furniture , electrification, overhead stagingand water supply fitting and as per drawing No. DGAR/COB/02 (Sheet No 01/11 to 11/11) and directed by Engr-In-Charge. |
| 51 | Construction of PUF shelter for Sentry post/Gd room complete all as perspecifications and drawing No. DGAR/COB/115 (Sheet No 01/04 to04/04) and directed by Engr-In-Charge. |
| 52 | Construction of PUF shelter (18.30x6.10m) for Signal Centre/MI room/Coy office including plinth/foundation with vitrified tiles flooring, plinth protection, furniture and electrification all as per techincal specification and drawing No. DGAR/COB/04 (Sheet No 01/09 to 09/09) and directed by Engr-In-Charge. |
| 53 | Construction of PUF shelter (7.20x2.22M) for Six men toilet blockincl plinth/foundation, vitrified tiles flooring, plinth protection, minimum one EWS for each block, electrification,toilet, sanitary and water supply fitting, overhead water tank staging complete all as per specifications and drawing No. DGAR/COB/114 (Sheeet No 01/03 to 03/03) and directed by Engr-In-Charge. |
| 54 | Schedule A (Part-II) Construction of security fencing all as per drawing and specification and detailed estimate. Earth work excavation by mechanical means Hydaulic excavator/manual means in foundation trenches or drains (nor exceeding 30 cm in depth, 1.5m in width or 10 sqm on plan), including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed by Engineer -In- Charge. |
| 55 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level 1:3:6 (1 Cement : 3 Coarse sand : 6 graded stone aggregate 40mm nominal size) |
| 56 | Centering and shuttering including struting, propping etc and removal of form for walls (any thickness) including attached pilasters, plinth posts etc. |
| 57 | Supplying at site angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10mm dia etc complete 65x65x6mm angle iron post for both iron pillar and strut post. |
| 58 | Fencing with welded steel wire favric fencing with posts of specified material and standard design of size 75mmx 75mm using 4mm dia GI wire. |
| 59 | Extra for providing and fixing FI strip for barbed wire of 40x6mm flat iton section. |
| 60 | Painting with aluminum paint of approved brand and manufacture to give an even shade two or more coats on new work on chain link fencing. |
| 61 | Providing and fixing concertina coil fencing with punched tape concertinal coil 600mm dia 10 metre openable length (total length 90m) , having 50 nos rounds per 6 metre length, upto 3m height of wall with existing angle iron \"Y\" shaped placed 2.4m or 3.00m apart and with 9 Horizontal (R.B.T reinforced barbed wire, stud tied with G.I staples and G.I clips to retain horizintal, including necessary bolts or G.I barbed wire tied to angle iron all complete as per direction of Engineer- In- Charge. |
| 62 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be shuttered on both sides and end post on one side only and provided with horizontal lines and two diagnols interwoven with horizontal wires, of barbed wire weighing 9.38 Kg per 100m (minimuim), between the two posts fitted and fixed with G.I. staples, turn buckles etc complete. (Cost of posts, struts, earth work and concrete work to be paid for seperately). Payment to be made per metre cost of total length of barbed wire used. 16.18.1 with G.I barbed wire. |
| 63 | Painting with aluminium paint of approved brand and manufacture to give an even shade Two or more coats on new work on chain link fencing. |
| 64 | Schedule A (Part-IV) Construction of Retaining wall all as per drawing and specification and detailed estimate.Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includig dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 65 | Providing and laying of position cement concrete of specified grade ecliding the cost of centering and shuttering with mix of 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) all work upto plinth level. |
| 66 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12(1 Cement : 6 coarses sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 Cement : 6 coarses sand). |
| 67 | Random rubble masonry with hard stone in Superstructure above plinth level and upto floor five level, including levelling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) above plinth level with : Cement mortar 1:6 (1 Cement : 6 coarse sand). |
| 68 | Providing and laying of cement concrete in cooping of R.R masonry retaining walls of specified grade excluding the cost of centering and shuttering with mix of 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) upto floor five level. |
| 69 | Raised and cut pointing in stone work in white cement mortar mix of 1:3 (1 cement : 3 fine sand). |
| 70 | Supplying and stacking at site 20 mm size stone aggregate. |
| 71 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. |
| 72 | Providing and laying opposition cement concrete of specified gradient excluding the cost of centenring and shuttering with mix of (1:2:4) (1 cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size) all work upto plinth level |
| 73 | Providing and laying of position cement concrete of specified grade excliding the cost of centering and shuttering with mix of 1:3:6(1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) all work upto plinth level. |
| 74 | Schedule A (Part-V) Construction of Storm Drainage all as per drawing and specification and detailed estimate. Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5 m disposal soil to be levelled and neatly dressed. All kind of soil. |
| 75 | Earth work in excavation by mechanical means (Hydraulic excavation)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m, all kind of soil. |
| 76 | Providing and laying in position cement, concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size. |
| 77 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 78 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : cement mortar 1:6 (1 cement : 6 coarse sand). |
| 79 | 12 mm cement plaster of mix 1:4 (1 cement : 4 fine sand). |
| 80 | Schedule A (Part-VI) Provision of PCC Footpath with Chequred Tiles.Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5 m disposal soil to be levelled and neatly dressed. All kind of soil. |
| 81 | Supply and lying stone aggregate of 90 to 45mm size of WBM with moroum as binding material including 13.2mm size stone screening sorting, watering spreading to template, compacting stone aggregate in uniformed thickness and consolodiation with power road roller of 8 to 10 tonne capacity in two layer with proper gradient |
| 82 | Providing and laying of position cement concrete of specified grade excliding the cost of centering and shuttering with mix of 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone agregate 20 mm nominal size) all work upto plinth level. |
| 83 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses plinth and string courses etc. |
| 84 | Chequerred precast cement concrete tiles 22mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 85 | Schedule A (Part-VII) Provision of Earthwork in excavation in over areas.Earth work in excavation by mechanical means (hydrolic excavator) manual means over area. |
| 86 | Schedule A (Part-VIII) Sewage Disposal System Septic Tank 50 user all as per drawing No DGAR/Engr/355 (Sheet No 01/01) |
| 87 | Septic Tank 20 user all as per drawing No DGAR/Engr/355 (Sheet No 01/01) |
| 88 | Soak Pit all as per drawing No DGAR/Engr/356 (Sheet No 01/01) |
| 89 | Mainhole Chamber all as per drawing No DGAR/Engr/356 (Sheet No 01/01) |
| 90 | Laying of PVC sewage pipiline 110mm diameter in trenches incl earthwork execuation and filling complete |