|
| 1 | DSR-2023, Item No.2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 2 | DSR-2023, Item No.2.31Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 3 | DSR-2023, Item No.4.1.3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | DSR-2023, Item No.4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | DSR-2023, Item No.4.6.1Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 6 | DSR-2023, Item No.4.1.7Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 7 | DSR-2023, Item No.5.1.2Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | DSR-2023, Item No.5.9.1Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 9 | DSR-2023, Item No.5.9.6Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 10 | DSR-2023, Item No.5.22.6Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 11 | DSR-2023, Item No.6.1.2Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 12 | DSR-2023, Item No.13.2.215 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) |
| 13 | DSR-2023, Item No.13.186 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. Neat cement punning. |
| 14 | DSR-2023, Item No.14.1.1Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) |
| 15 | DSR-2023, Item No.14.17Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 16 | DSR-2023, Item No14.76Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 17 | DSR-2023, Item No.14.77Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia upto 300 mm |
| 18 | DSR-2023, Item No.19.6.2Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe |
| 19 | DSR-2023, Item No.19.6.3Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe |
| 20 | DSR-2023, Item No.19.6.4Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe |
| 21 | DSR-2023, Item No.19.35.1Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 450 mm dia RCC pipes. |
| 22 | DSR-2023, Item No.21.1.1.2Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge |
| 23 | Market rateCleaning of septic tank by using vehicle mounted tankers of 4000 Ltrs or more and including cost of all labour charge, transportation, taxes, loading, unloading etc complete as pr the direction of Officer-in-charge. |
| 24 | Market rateProviding semiskilled manpower (like Fitter/Electrician etc. having relevant qualification and experience in similar nature of job) for operation of Sewage treatement Plant including all cost and T&P complete as per the direction of the Engineer-in-charge. |
| 25 | Market rateEngagement of contigent semi skilled manpower as per requirement |
| 26 | Market rateEngagement of contigent unskilled manpower for various miscellaneous works |
| 27 | Market rateSupply of Sodium Hypochloride for daily dosing purpose of STP effiuent water includingall cost, transportation to STP, loading & unloadingcomplete as per the direction of Engineer-in-charge. |
| 28 | Market rateEngagement of Tractorwith trolley for shifting of materials in trips of full load up to a distance of 5 Km insidethe campus including costof fuel, driver etc all complete. |
| 29 | Market rateEngagagement of JCBfor miscellaneous works suc as levelling of soil, jungle/bush cleaning including cost of fuel, driver etc all complete. |
| 30 | Market rateRewinding Charges 3 Phase 5HP STP C Series Submersible Sewerage Pump Set (Non-Clogging Type)Make Crompton |
| 31 | Market rateRewinding Charges 1 Phase 1HP Submersible Recirculation Pump Set (Non-Clogging Type)Make LUBI(LFP 2115F) |
| 32 | Market rateRewinding Charges 1 Phase 3HP Submersible Pump Set (Non-Clogging Type)Make LUBI(LFP 3315F) |
| 33 | Market rateRewinding Charges 1 Phase 2HP Submersible Pump Set (Non-Clogging Type)Make LUBI(LFP 3215F) |
| 34 | Market rateRewinding Charges Ring Blower 3 Phase 2.2KW Blower Motor Make CLEANTEK |
| 35 | Market rateOverhauling of 3 Phase 5HP STP C Series Submersible Sewerage Pump Set (Non-Clogging Type) Make Crompton |
| 36 | Market rateOverhauling of 1 Phase 1HP Submersible Recirculation Pump Set (Non-Clogging Type)Make LUBI(LFP 2115F) |
| 37 | Market rateOverhauling of 1 Phase 3HP Submersible Pump Set (Non-Clogging Type)Make LUBI(LFP 3315F) |
| 38 | Market rateOverhauling of 1 Phase 2HP Submersible Pump Set (Non-Clogging Type)Make LUBI(LFP 3215F) |
| 39 | Market rateOverhauling of Ring Blower 3 Phase 2.2KW Blower Motor Make CLEANTEK |
| 40 | Market rateRemoval of submersible sewage pump, sensor from sewerage tank & Re-installation after necessary maintenance12 man-day for 24 pumps (quartly)Total requirement in a year 12x4=48 man day |
| 41 | Market rateCleaning & maintenance of submersible pump, sensor, pressure switch/guage 01 fitter & 01 helper 1man day =04 pumps for 20 pumps = 6 man dayquartly 6x4 = 24 man day (each for fitter & helper)(i)Skilled man power for cleaning & mainteance |
| 42 | Market rateCleaning & maintenance of submersible pump, sensor, pressure switch/guage 01 fitter & 01 helper 1man day =04 pumps for 20 pumps = 6 man dayquartly 6x4 = 24 man day (each for fitter & helper)(ii)Unskilled man power as helper |