| 1 | SUPPLY OF MATERIALS: |
| 2 | Construction of 132kV D/C transmission line from 220/132/33kV Diezephe Sub-station to Molvom Railway Sub-station: |
| 3 | Conductor |
| 4 | ACSR \"Zebra\" Conductor |
| 5 | Type test charges for Conductor |
| 6 | OPGW cable & Accessories |
| 7 | 24 Fiber (DWSM) OPGW fiber optic cable live line (With Central Fibre Optioc Unit of Steel tube Design) |
| 8 | Suspensipon Clamp assembly for 24 Fibre OPGW |
| 9 | Dead end Tension clamp for 24 fibre OPGW |
| 10 | Tension fittings assembly for 24 fibre OPGW including all accessories for joint box (Splicing) Location |
| 11 | Passing Tension clamp for 24 Fibre OPGW |
| 12 | Tension fittings assembly on Suspension tower for 24F OPGW including all accessories for joint box (Splicing) Location |
| 13 | Down lead clamp assembly for 24F OPGW |
| 14 | Vibration Damper for 24 F OPGW |
| 15 | Joint Box for 24 Fibre OPGW |
| 16 | FODP |
| 17 | FODP 48F: Indoor Type, rack mounted with FCPC coupling and pig tails (5 mtrs each) |
| 18 | Fibre Optic approach cable |
| 19 | 24 Fibre (DWSM) |
| 20 | Installation hardware set for above 24 Fibre, Fibre Optic Approach cable |
| 21 | Insulator |
| 22 | Long Rod 120kN 132kV Grade Polymer Insulator with Corona Ring |
| 23 | Type Test Charges for Insulators |
| 24 | Hardware Fitting |
| 25 | Hardware fittings for ACSR Zebra Conductor-Double Tension String |
| 26 | Hardware fittings for ACSR Zebra Conductor-Single Tension String |
| 27 | Zebra Conductor Accessories: |
| 28 | MSCJ for Conductor |
| 29 | Repair Sleeve for Conductor |
| 30 | Vibration Damper for Conductor |
| 31 | Type Test charges for conductor accessories |
| 32 | Tower Accessories: |
| 33 | Number plate |
| 34 | Danger Plate |
| 35 | Phase Plate |
| 36 | Anti climbing Device |
| 37 | Earthing of Towers |
| 38 | Counterpoise Type (120m length) |
| 39 | Shieldwire Earthing Including PG clamps, Downlead clamps but excl. Earthwire pits i.e, Shield wire earthing( pipe type/counterpoise type) shall be as additional to items i.e, Earthing of towers (Counterpoise type) |
| 40 | Tower High Tensile Steel (Annexure-Ib) |
| 41 | Fabrication, galvanising & supply of various types of towers parts, tower/leg extensions (complete) excluding stubs & bolts & nuts but including hangers, D-Shackles, pack washers etc. for Normal Towers GI |
| 42 | Hexagonal bolts & Nuts |
| 43 | Anti-theft bolts & Nuts |
| 44 | Construction of 132kV Molvom Take Off bay (2 Nos) at 220kV Diezephe Sub-Station: |
| 45 | 132kV Circuit Breaker, 3-ɸ |
| 46 | 132kV, 2500A, 50kA, 3-ɸ Double break isolator with earthswitch (Electrically Operated) |
| 47 | 132kV, 2500A, 50kA, 3-ɸ Double break isolator without earthswitch (Electrically Operated) |
| 48 | 132kV Current Transformer 2500A,31.5kA, 1-ɸ |
| 49 | 132kV Surge Arrester, 1-ɸ |
| 50 | 132kV Post Insulator Solid Core, 1-ɸ |
| 51 | 132kV CVT, 1-ɸ |
| 52 | 132kV PT, 1-ɸ (Bus) |
| 53 | 132kV Control Relay Panel for Line protection (with Automation) |
| 54 | ACSR \"Moose\" Conductor for 132kV Bay |
| 55 | Earthwire (G.S, 7/3.15 mm) |
| 56 | 40mm MS Rod for Earthmat |
| 57 | Long Rod 120KN 132kV Grade Polymer Insulator with Corona ring |
| 58 | Hardware Fittings for ACSR Moose conductor-Single Tension String |
| 59 | 132kV Connector clamp suitable for Single ACSR Moose Conductor |
| 60 | 132kV T-Clamp suitable for SingleACSR Moose Conductor |
| 61 | GI Structure |
| 62 | Marshalling Box for C.T & PT |
| 63 | Control Cables: |
| 64 | (a). 2 x 2.5Sqmm |
| 65 | (b). 4 x 2.5Sqmm |
| 66 | (c). 7 x 2.5Sqmm |
| 67 | (d). 10 x 2.5Sqmm |
| 68 | Suspension Clamp |
| 69 | Earthing Electrodes |
| 70 | Galvanised earthing strip |