|
| 1 | Earth work in excavation by mechinical means in trenches for foundations, drains, pipes, cables etc. (Not exceeding 1.5 mtr in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, depth upto 1.5mtr. including disposal of excavated earth upto 1 mtr from cutting edge, disposed earth is to be levelled and neatly dressed in all kinds of soil. |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 4 | Brick work with common burnt clay F.P.S.(non-modualar) bricks of class designation 75 in foundation and plinth in Cement mortar 1 :6 ( 1 cement : 6 coarse sand) & Extra for brick work in superstructure above plinth level upto floor V level. (By manual means) |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Centring and shuttering including strutting , propping etc. and removal of form work for Foundations , footings bases of columns etc. for mass concrete |
| 8 | Centring and shuttering including strutting , propping etc. and removal of form work for Suspended floors, roofs, landing, balconies and access plate form |
| 9 | Centring and Shuttering including strutting, propping etc and removal of form work for Edges of Slabs and Break in floors and walls (Under 20 cms wide) |
| 10 | 6mm cement plaster to ceiling of mix 1:3 ( 1 cement :3 fine sand). |
| 11 | 12 mm cement plaster of mix 1:6 ( 1 cement : 6 coarse sand) |
| 12 | 15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand) |
| 13 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 10.5.1 Using M.S. angles 40x40x6mm for diagonal braces |
| 14 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 15 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All works upto plinth level in (1:2:4) grade with 20mm nominal size of crushed stone aggre-gates. |
| 16 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. in colour such as White, Ivory, Grey, Fume Red Brown |
| 17 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 18 | Making plinth protection 50mm thick with cement conc .(1:3:6) ,20 mm nominal size of stone aggregates over 75mm bed of dry brick ballast,40mm nominal size of well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 19 | Painting with ready mixed synthetic enamel paint of approved brand and manufacture in all shades to give an even shade New steel work (two or more coats) |
| 20 | Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade/ colour complete as per manufacturer\"s specifications Two or more coats on new work |
| 21 | Finishing walls with water proofing cement paint of required shade New work (two or more coats) applied @ 3.84 kg/10 sqm |
| 22 | Providing and fixing G.l. pipes complete with G.l. fittings and clamps, including cutting and making good the walls etc.: INTERNAL WORK-Exposed on wall 15 mm dia. nominal bore light |
| 23 | Providing and fixing G.l. pipes complete with G.l. fittings and clamps, including cutting and making good the walls etc.: INTERNAL WORK-Exposed on wall 20 mm dia. nominal bore light |
| 24 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 25 | Providing & fixing C.P brass angle valve for basin mixer and geyser points of approved make conforming to IS:8931 (15mm nominal bore) |
| 26 | Providing & fixing White vitreous china water closet squatting pan(Indian type) along with “S” or “P” trap including dismantling of old WC seat and S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm |
| 27 | Providing and fixing wash basin with C.I/M.S brackets, 15mm C.P brass pillar taps, 32mm C.P brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China wash basin size 550x400 mm with single 15 mm C.P. brass pillar taps.(Hindware/Cera) |
| 28 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back ,for the reception of pipes and fittings |
| 29 | Providing & fixing C.P brass bib cock of approved quality conforming to IS:8931.(15mm nominal bore) |
| 30 | Providing and fixing uplasticised PVC connection pipe with brass unions 15 mm nominal bore |
| 31 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete Flexible pipe 32 mm dia |
| 32 | Providing and fixing CP grading of 100 mm dia of approved brand. (Jaquar Essco) |
| 33 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20 mm nominal bore |
| 34 | Providing and fixing PVC pipe at the weight of 4 kg/sqcm Finolex /Supreme 110 mm diametre |
| 35 | Providing and fixing PVC pipe at the weight of 4 kg/sqcm Finolex /Supreme 75 mm diametre |
| 36 | Providing and fixing electric points as per necessity at site |
| 37 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. Sand lead up to 60 kms avge. |
| 38 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. Stone aggregate lead up to 30 kms avge. |
| 39 | Carriage of materials by mechanical transport including loading / unloading and stacking complete. Bricks lead up to 90 kms avge. Please Enable Macros to View BoQ information |