| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..( Group C). [P.S. No.1.10.3] |
| 2 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. [P.S. No. 1.11] |
| 3 | cost of inverter wiring point light/fan /plug with 1.5 sq mm cu wire. [P.S. No.1.17.1] |
| 4 | wiring for circuit / submain wiring along with earth wire the following sizes of FRLSH PVC insulated copper conductor ,single core cable in surface /recessed medium class PVC conduit as required.2X 2.5 sqmm + 1 X 2.5 sqmm earth wire [P.S. No.1.14.2] |
| 5 | wiring for circuit / submain wiring along with earth wire the following sizes of FRLSH PVC insulated copper conductor ,single core cable in surface /recessed medium class PVC conduit as required.2X 4 sqmm + 1 X 4 sqmm earth wire [P.S. No.1.14.3 ] |
| 6 | wiring for circuit / submain wiring along with earth wire the following sizes of FRLSH PVC insulated copper conductor ,single core cable in surface /recessed medium class PVC conduit as required.2X 6 sqmm + 1 X 6 sqmm earth wire [P.S. No. 1.14.4] |
| 7 | wiring for circuit / submain wiring along with earth wire the following sizes of FRLSH PVC insulated copper conductor ,single core cable in surface /recessed medium class PVC conduit as required.2X 10 sqmm + 1 X 6 sqmm earth wire [P.S. No. 1.14.5] |
| 8 | wiring for circuit / submain wiring along with earth wire the following sizes of FRLSH PVC insulated copper conductor ,single core cable in surface /recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire [P.S. No. 1.14.11] |
| 9 | S/F of Modular Computer Board with 2 No\"s. 5/6 Amp. Switch & Socket and 1 no. 15/16 Amp. Switch & Socket. [P.S. No. A/R] |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | a- 5/6 amps switch [P.S. No. 1.24.1] |
| 12 | b- 3 pin 5/6 amp socket outlet [P.S. No.1.24.4 ] |
| 13 | Supply and fixing of 6 Amp. to 32 Amp. MCB.(10KA) [P.S. No. 2.10.1] |
| 14 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. [P.S. No. 2.18] |
| 15 | Supply & fixing 12 way SPN ,(single pole and neutral) , sheet steel ,MCB distribution board , 240 V ,on surface / recess , complete with tinned copper bus bar ,neutral basbar , earth bar , din bar, interconnections, powder painted including earthing etc. as required.(But without MCB /RCCB/Isolator) [P.S. No. 2.3.3] |
| 16 | Supply & fixing 6 way VTPN ,horizontal type three pole and neutral , sheet steel ,MCB distribution board , 415 V ,on surface / recess , complete with tinned copper bus bar ,neutral busbar , earth bar , din bar, interconnections, powder painted including earthing etc. as required.(But without MCB /RCCB/Isolator) [P.S. No. 2.4.2] |
| 17 | S/F of 40 A DP MCB without enclosure complete in all respect. [P.S. No.A/R ] |
| 18 | S/F of 63 A FP MCB without enclosure complete in all respect. [P.S. No. A/R] |
| 19 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 20 | 2 X 6 sq. mm (19mm) [P.S. No.11.1.1 ] |
| 21 | 3½ X 35 sq. mm (32mm) [P.S. No.11.1.21 ] |
| 22 | 3½ X 70 sq. mm (38mm) [P.S. No. 11.1.23] |
| 23 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. [P.S. No. 5.4] |
| 24 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) [P.S. No. 5.11] |
| 25 | Supply, installation, Testing and Commissioning of 1200mm sweep, BEE 5 star rated, ceilling fan with Brush Less direct current (BLDC) moter ,class of insulation ;B 3 no. blades ,30 cm long down rod, 2nos canopies , shackle rope, copper wiring , power facter not less than 0.9 , service value (CM/M/W) minimum 6.00 , AIR delivery miniimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374 -2019), THD less than 10% ,remte or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise =75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz , single phase AC Supply ,earthing etc.comple as required. [P.S. No.9.1.3 ] |
| 26 | Supply and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting. [P.S. No. 13.34] |
| 27 | Supply and fixing of LED Tube Light with heavy duty Metal Boxtype Tube Light fitting 1x22 watt suitable for upto 1x 22 watt LEDPolycarbonate tube light complete Including tube suitable for bothsurface & suspended complete in all respect 2620 system lumens, >120 Lm/W, PF>0.95, THD<10%, CRI >80, sheet thickness min 0.8mm, Tube with aluminium heat sink, >300V over voltage protection, 2.5 KV internal Surge Protection, with 5year warrantee CAT-AAA [P.S. No. 8.9.1] |
| 28 | Supply and fixing of IP 20, Mid Power SMD type LED Light, 2\"x2\"50 Watt , Indoor Recess mounting LED Square Fitting for Armstrong Ceiling Powder coated CRCA housing body, High purity / transmisivity UV Stabilized Non yellowish diffuser/ Reflector for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24 Hr Continuous Operation, Complete in All respect. 4320-5520 system lumens, with fully covered diffuser type, >120 Lm/W, PF>0.95, THD <10% at full load, CRI >80, >300V over voltage protection, 4 KV internal Surge Protection,with 5 years warrantee.CAT-AAA [P.S. No. 8.12.12] |
| 29 | Supplying and fixing of 20 Watt Lamp Based LED Mirror Light Complete in all respect. [P.S. No. A/R] |
| 30 | Supplying and fixing of Single Light Wall Bracket (9 Watt LED ) Complete in all respect. [P.S. No. A/R ] |
| 31 | Supply and fixing of decorative 40 Watt to 45 Watt, LED Post top indirect light luminaire having Pressure die cast aluminium body and UV Stabilized PC Clear/ frosted glass cover, with driver set confirming to IP 66 and IK 08 protection, Potted driver (Not circuitory) complete in all respect 4800-5400 system lumens, >120 Lm/W, PF>0.95, THD <10% at full load, CRI >70, > 300V Over VoltageProtection and auto restart feature, 4 KV internal SurgeProtection, with 5 years warrantee.CAT-AAA [P.S. No. 23.21] |
| 32 | Supply & fixing of water tight oblong 10 watt LED Bulkheadluminaire having pressure die cast housing with driver setconfirming to IP65 and above protection, IK 08, High purity /transmisivity UV Stabilized Non yellowish diffuser/ for uniformlight distribution, detachable driver set, open and short circuitprotection, suitable for 24 Hr Continuous Operation, Complete inAll respect. compelete in all respect. 1200 system lumens, >120 Lm/W, PF>0.95, CRI >70, >300V overvoltage protection, 4 KV internal Surge Protection, metal housingwith 5 years warrantee. CAT-AAA [P.S. No. 23.11] |
| 33 | Supply and fixing of LED Street light fitting with Mandatory driver set heavingdie cost aluminium body with toughend glass/UV suitable stabilized PC cover and lenses suitable for 140 watt to 150watt and confiming to IP 66 and IK 07 and above protection heaving company LOGO Engraved complete in all respect including labour. CAT-AAA 16800-18000 system lumens, high power LED with lenses>120Im/W, PF>0.95, THD<10% at full load CRI>70 potted driver set in metal housing (not circuilory ) phase to phase protection at 440V &> 300 V auto cut and restart feature, 4 KV internal suger protection with 5 Year warantee. [P.S. No. 8.12.17] |
| 34 | S/F of 7/9 Watt LED Bulb Havells or equivalent. [P.S. No.A/R ] |
| 35 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. (2 Nos. of switch and sockets are reqired for each cable TV points.) [P.S. No. 1.29] |
| 36 | Supplying and fixing of TV antenna socket outlet piano type on the existing switch box/ cover including connections etc. as required. [P.S. No. 1.23.7] |
| 37 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required. [P.S. No. 1.19] |
| 38 | Supplying and fixing of 25 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required(25m taken for each TV Cable and 25 m for all plug points). [P.S. No. 1.21.2] |
| 39 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. including excavation and refilling The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 40 | a- 6 sq mm 2 core [P.S. No. 20a.1.1] |
| 41 | b- 35 sq mm 3-1/2 core [P.S. No. 20a.1.11] |
| 42 | c- 70 sq mm 3-1/2 core [P.S. No. 20a.1.13] |
| 43 | Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering.All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A &above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type.Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/CProtection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA \"C\" Curve. Cubicle type switch board shall be Cat- B only. Incoming :-200 Amp. FP MCCB Outgoing:- 63Amp. FP MCCB 03 Nos. [P.S. No. 22.1.2.b.ii] |
| 44 | Supply and fixing of plain or pin type copper tin platedcable socket ( lug ) to the cable leads, insulating with tapeand making connection etc. complete in all respect as perdirection of the Engineer-Incharge. |
| 45 | a-4 sq mm [P.S. No. Q/R] |
| 46 | b-6 sq mm [P.S. No. Q/R] |
| 47 | c-10 sq mm [P.S. No. Q/R] |
| 48 | d-16 sq mm [P.S. No. Q/R] |
| 49 | Supply and laying of of 1800 mm x 900 mm x 12 mm thick chequered rubber matting of quilty. [P.S. No. Q/R] |
| 50 | Supply of Fresh Air Fan 200 mm Sweep Complete in all respect. [P.S. No. A/R] |
| 51 | Supply and fixing of 200 Amp. Change Over switch Complete in all respect. [P.S. No. A/R] |
| 52 | Dismantling of old DB\"s, old mains switch and removing of old aluminium wiring in office. [P.S. No. ] |
| 53 | a-Electrician (1 No.) [P.S. No. 1019] |
| 54 | b-Khallasi. (2 No\"s.) [P.S. No. 1007] Please Enable Macros to View BoQ information |