| 1 | Demolition of Bricks or stone masonry built in cement mortar complete all as specified and as directed. |
| 2 | Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc as in external surfaces of man holes, septic tank, filter bed etc incl removing of debries complete all as specified and as directed. |
| 3 | Demolition, Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 4 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing complete all as specified and as directed. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided for etc.complete all as specified and as directed. |
| 6 | Dismantling wall and ceiling boards, fibre pulp insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 7 | Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m in depth for foundation or manholes etc, and area n.exc 10 Sqm on plan and getting out in any typesoil complete all as specified and as directed. |
| 8 | Excavating over areas, n exc 1.5m deep and getting out in soft/loose soil, complete all as specified and as directed. |
| 9 | Returning, filling in with approved soil obtained from excavation including spreading levelling, watering and well ramming in layers n.exc. 25cm thick all as specified and as directed. |
| 10 | Removing excavated soil to a distance n exc 50m and depositing where directed at a level not exc1.50m above the starting point complete all as directed. |
| 11 | Demolition and breaking up drain CI pipe/AC pipes/ PVC Pipe set in cement mortar 100 mm and below complete all as specified and as directed. |
| 12 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floor bore of the pipe 110 mm of wall thicknessnot less than 4mm complete all as specified and as directed. |
| 13 | S&F PVC(SWR) bends 110 mm dia with access door complete all as specified and as directed. |
| 14 | M&L brick work with sub class \"B\" brick, straight or curved on plan exc 6 M Mean radius built in type CM 1:6 complete all as specified and as directed. |
| 15 | All as per srl item No 14 above but except brick only complete all as specified and as directed. |
| 16 | M&L for walling of randomrubble masonary, Square, recangular coursed, well bonded, bedded and solidly hearted, built in CM (1:6) complete all as specified and as directed. |
| 17 | All as per srl item No 15above but except stone masonry complete all as specified and as directed. |
| 18 | M & L Rendering 15 mm thick on brick or concrete surfaces of walls in CM (1:4) including finishing the surfaces fair and even without using extra cement as in manholes, septic tank, filter bed out let drain, bdy walls, drains etc all as directed |
| 19 | M&L for raised pointing to random or polygonal rubble masonary coursed or un coursed inCM (1:3) complete all as specified and as directed. |
| 20 | M&L for complete removal of existing treatment on walls/roof projection including facia, cornices etc scrapping with (having mechanical vacuum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour with mechanical sander having RPM of 1500-2700 rpm with internal dust extraction system for clean environment all as directed. |
| 21 | Preparation of old plastered/scrapped surface of wall/ceiling by filling cracks by external wall putty/ crack fill paste and applying exterior water proof wall care putty @ 1 Kg (undiluted) per sqm of average thickness 1mm to 2mm over the plastered wall/ceiling surfaces complete all as directed |
| 22 | M&l for grinding the puttied surface with mechanical grinder for make the surface even and smooth for receiving primer complete all as directed |
| 23 | M&L for priming coat of exterior primer applied @ 0.9 ltr (undiluted)/10 Sqm over old putty surface of wall/ceiling complete all as specified and directed |
| 24 | M&L applying two or more coats of 100% premium acrylic smooth exterior emulsion paint having VOC less than 50 gms/litre and UV resistance as per IS 15489 :2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives & colour stay technology, excellent dirt pickup resistance @ 1.79 litre/10 Sqm diluted with water as per manufacturer instruction, Paint usingAirless spray technology with max working pressure of 3300 PSI and capable of opening single spray gun with a mix material hose length of 30 mtr the spray machine should be reputed brands. Make : Asian Paints Apcolite Premium Emulsion,Birla Opus Calista (Premium), Berger Elegance, Nerolac Beauty Gold Washable / Washable Plus.Note : Material directly procured from authorised dealer of manufacturer andwhich will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor. |
| 25 | M&L for Plain cement concrete type B1 (1:2:4) (using 20mm graded stone aggregate) as in surface chanels and drains, manhole complete all as specified and as directed. |
| 26 | M & L Plain cement concrete type-B1(1:2:4) (using 20mm graded stone aggregate ) as in benching, haunching , coping, edging of path and similar work incl necessary form work complete all as specified and directed. |
| 27 | M&L for 75 mm thick plain cement concretetype D-2 (1:4:8) (40 mm graded stone aggregates) as in sub basecomplete all as specified and directed. |
| 28 | M&L for chequered cement concrete (glossy finish) tile 300 mm x 300 mm x 25 mm thick setjointed andpointed in neat cement slurry in floor with grey cement and pigment all as specified and directed. |
| 29 | M&L for 15 mm thick screed bed in cement mortar 1:6 for layingfloor finishes under floor complete all as specified and as directed. |
| 30 | M&L forheavy duty coloured (Dura stone) tiles n exc 0.36Sqm of 8-10mm thick tiles as in floors etc. set and jointed in neat cement slurry and pointedin white or coloured cement to match complete all as specified and directed. |
| 31 | M&L for glazed ceramic wall cladding coloured tiles 300mm x 450mm x 7mm or 300x600x7-10mm thick (design and size as approved by Engr in Charge)as in vertical surfaces of walls, set and jointed inneat cement slurry and pointed in white or coloured cement to match over 10mm cement rendering in cement mortar 1:4 or chemical adhesive as directed by Engr in Charge complete all as specified and as directed. Make : Somany Clador Atico Blue or Kajaria Vitronite K 34020G or Orient Bell Craftclad Linear Engrave Multi or as approved by Engr in Charge” |
| 32 | M & L for PCC 1:1.5:3 Type B2 using 20mm graded aggregate as in foundations, filling and mass concreteas padding on roof surface includingwith water proofing compound/admixer like Ulratech Seal & dry SBR or its Equivalent make in Dr Fixit/Fosroc as per manufacture\"s instructions complete all as specified. Note : use concrete mixer for concreting, no hand mixing allowed. Waterproofing compound/admixer shall be paid separately. |
| 33 | Waterproofing compound/admixture Ulratech Seal & dry SBR or its Equivalent make in Dr Fixit/Fosroc as per manufacture\"s instructions complete all as specified and as directed. |
| 34 | Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tar felt and brushing neat cement slurry @ 3 kg/Sqm. Applying compatible bituminous primer on prepared surfaces and allow it to dry. Provide APP modified polyester reinforced bituminous membrane 4mm thick plain finish with torch the substrate and the underside of the membrane until the bituminous becomes glossy. Press the membrane firmly to ensure full adhesion. Maintain side overlap of 100mm and end overlap of 150mmcomplete all as specified and as directed. Make : UltraTech Weather Pro APP Membrane or equivalent make as directed by Engr in Charge. Note :Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise. |
| 35 | S&F 4mm thick Cement fibre board (designer ceiling) of size 600mm x 600mm panel conforming to IS 14862 type B category three including GI frame work with size of grid 605mm x 605mm including all accessories and GI suspensions. The fibre sheet should be fire resistant, water resistant, termite resistant, environment friendly & 100% asbestos free complete all as specified and as directed |
| 36 | M&L for 3 coats of Prime B90 elastomeric waterproofing liquid applied membrane which is formulated with acrylic fibres and PU hybrid polymers having crack bridging ability of upto 3mm, tensile strength of 1.8 Mpa, 300% elongation and can withstand upto 12 bars hydrostatic pressure. The coating also provided with anti carbonation properties and ensures surface temperature reduction of upto 12 degree C. Coating to ensure a forced coverage of 10 Sqft/3 coats on terrace and horizontal surface having 33% water dilution in 1st coat and an undiluted 2 coats as per manufacturers instructions complete all as specified and as directed.Make : Birla Opus, Asian Paints/ UltraTech/Dr Fixit. Note :Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise. |
| 37 | S&F 10-12 mm thick gypsum boards seamless false ceiling including sunk or raised moulding or cop design as approved, moisture resistant, including GI hanging wires & frames with intermediate, perimeter channel ceiling channel, along nuts and bolts connecting plates gypsum boards, dry wall screws soffits cleats, ceiling section, rawel plugs fixtures and screws and applying two coats of emulsion paint over a coat primer on exposed surface complete all as specified and directed.Note : (a) Design of ceiling board as approved by Engr-in-Charge. (b) GI grid/hanging system shall be of the same make as of false ceiling manufacturer |
| 38 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 39 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. |
| 40 | M&L for framed work such grill, griting as doors, gates of angle or other section with gusset plates, rails, braces, etc complete drilled for fixing of steel sheeting or other covering doors, etc to be prepared for hanging or sliding eith and including either hooks and hinges or steel hanging door fittings including ornament and intricate design, including pintle hings, stops hand made sliding bolts etc conforming to Fe 290 Gde-E-165 complete all as specified and as directed. |
| 41 | M&L for preparation of new steel surfaces of any descripton not otherwise described over 10 cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide on steel surfaces . |
| 42 | M&L for Precast cement concrete louvers and jallies 25mm thick set in cement mortar 1:4 type B0 (1:2:4 using 12.5mm graded aggregate etc sample as approved by GE incl taking out old precast jali complete all as specified and directed. |
| 43 | M & L 18-20 mm thick granite (of any type) work( table rubbed and polished) in steps, jambs, pillars, window sills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab complete all as specified and as directed. |