| 1 | Supply, laying, jointing & testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade (Earthed), of size 95 sqmm, 3 core in trenches / through GI pipe / fixed along pole structure with clamp etc complete all as specified & as directed. NOTE : (i)Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work.(ii) Any damages made to the existing services of MES/PHED/Defence nits/Other Depts like HT/LT UG cables, Water Supply/Sewage Pipe lines, OFC/BSNL/Signal communication cables etc. during the excavation/boring/road cuting etc. progress of the work shall be made good with proper jointing kits etc. as per original to the entire satisfaction of Engr-In-Charge & GE & the cost of the same is deemed to be included in the unit quoted rates. Decision of the AO shall be final & binding.(iii) Wherever the cables are to be laid/fixed on poles/walls/other surfaces the cost of clamping using appropriate size/type of MS clamps,nuts both etc is deemed to be included in the unit quoted rates. |
| 2 | Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for OUTDOOR termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mm complete. |
| 3 | Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for STRAIGHT THROUGH Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mm complete. |
| 4 | M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-55, 11.0 meter longinclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint incl preparation of surfaces complete all as specified and directed. The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161.NOTE : Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. |
| 5 | M&L for cross arms bracings supports, clamps and back plates fabricated from structural steel sections incl nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint incl preparation of surfaces complete. |
| 6 | M&L for anti-climbing devices, comprising of 2.24 mm dia galvanised steel 2-strand barbed wire with 2.00 mm dia barbs wrapped spirally round poles, to a length of 0.5 mtr to 1.0 mtr clamped & properly secured or as specified & as directed (clamps measured separately). |
| 7 | M&L for Pin type porcelain, vitreous, white, brown or green insulators inlcuding one GI spindle, two galvanized iron washers and one galvanized iron nut, 150 mm dia & 150 mm height suitable for working pressure 11 KV complete all as specified and as directed by Engr-in-charge. |
| 8 | M&L Disc type, porcelain, vitreous, 145mm High and 255mmdia ball and socket type white, brown or green insulator single disc assembly for tension with tension clamps for conductors, working pressurer 11000 volts grade complete all as specified and as directed by the Engr-in-Charge/GE. |
| 9 | Supply, install, testing & commissioning of gang operated device (GOD), triple pole, current rating 400 Amps, HT 11 KV vertical, mechanically operated mounted on insulators and steel frame with operating mechanism operated from ground with and including jumper connections with suitable size & type ACSR conductor along with PVC pipe covering with colour code between main supply and GOD incl taking down old existing one complete all as specified and as directed by the Engr-in-Charge/GE. |
| 10 | M&L for swing out expulsion fuse single pole (Drop Out Fuse) with fuse carrier , fuse element mounted on insulator & fitted on steel frame etc for 11000 volts of capacity (25-50) amps incl taking down old existing one complete all as specified and as directed by the Engr-in-Charge/GE. |
| 11 | S&F lightening arrester non-linear metal oxide type, complete with all fittings, transmission/distribution class, discharge capacity 65 Kilo amps suitable for 11 KV out door type including necessary connection and fittings all as per IS-3070 Part-III and IEC 1994 including dismantling of old unsv lightening arrestor including strap bolts, nuts and washers etc. complete all as specified and as directed by the Engr-in-Charge/GE. Make : ELPRO/OBLUM/JAIPURIA BROS/PACTIL |
| 12 | S&F danger notice plate of size 25 x 20cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for HT conforming to IS-2551 complete. |
| 13 | M&L for cement concrete in foundation, filling mass concrete type-C2, 1:3:6, (40mm graded aggregate) for pole foundation & finishing the surface even & smooth without using extra cement incl necessary formwork complete all as specified & as directed. |
| 14 | M&L for PCC (1:2:4) Type B-1 (using 20mm graded stone aggregate) for coping of poles etc & finishing the surface even & smooth without using extra cement incl necessary formwork complete all as specified & as directed. |
| 15 | M&L for aluminium conductor steel reinforced (ACSR) for jumpering of HT Line along with connecting accessories complete all as specified and directed by Engr-in-charge. |
| 16 | M&L for stay assembely with stay rod of dia 20mm with accessories as shown in electric plate No. 1 complete all as specified and directed by Engr-in-charge.( loop type insulator, excavation and concrete shall be measured and paid separately) |
| 17 | M&L for cable route indicator using RCC post 1.20 mtr long, top 100 x 100 mm & bottom 200 x 200 mm, with height not less than 50 cm above GL with engraved marking \" MES HT CABLE \" in bold letters during refilling of the trench complete. NOTE : The spacing between two consecutive cable route indicators shall not be more than 50.0 meters & also shall be provided at each & every bend or corner. |
| 18 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth forlaying of pipe and getting out in soft/loose dense soil complete. |
| 19 | All as per item Sl No - 18 here in before but exc 1.5m & n.exc 3.0 m in depth complete all as specified & as directed. |
| 20 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick. |
| 21 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. |
| 22 | M&L for cutting the existing hardstanding/PCC/WBM road at a depth of not less than 45 cm & 25 cm in width for passing of HT/LT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed. |
| 23 | M&L for boring under road manually/ Arguing the Hole under road with machine suitable for inserting upto 100 mm bore pipe at a depth 0.75 to 1.0 mtr complete all as specified and as directed. |
| 24 | M&Lfor GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 80 mm complete all as specified and directed. |
| 25 | M&Lfor GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 100 mm complete all as specified and directed. |
| 26 | M&L for providing sand cushioning for protection of UG cable in trenches with dry (coarse) river sand approved quality including filling, spreading and punning down to desired thickness & levelling, watering & consolidation in 15 cm layers on the level ground surface in Sub-Stns complete all as specified and as directed by the Engr-in-Charge/GE. |
| 27 | Supply and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300 x 180 x 40 mm in trenches for protection of UG Cable with width equal to length of PCC cover, laid dry & flat complete all as specified & as directed. |
| 28 | M&L for spreading & leveling of stone aggregates/Gravels of size 25 to 40 mmupto Max.75mm on sand filling in the Sub-Stns completeall as specified and as directed by the Engr-in-Charge/GE. |
| 29 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made out of 8 mm dia round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion incl taking down old existing unserviceable earthing along with all accessories complete all as specified and directed by Engr-in-charge. |
| 30 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made out of 8 mm dia round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion incl taking down old existing unserviceable earthing along with all accessories complete all as specified and directed by Engr-in-charge.Note for item No 28.00 & 29.00: On testing after completion, if the earth resistance is not obtained below 2 Ohms the earthing shall be redone at no extra cost till the entire satisfaction of Engr-in-Charge |
| 31 | S&F 32 x 6 mm galvanised iron strip as earth continuity conductor incl connection complete with the help of chromium plated washers, nuts etc. |
| 32 | S&F 40 mm dia GI pipe light grade on walls, floors under ducts/culverts, trenches etc. for protection of earthing lead complete. |
| 33 | M&L for dismantling of 11KV ACSR conductors fixed between PCC Poles incl disconnecting the electrical connection from line complete all as specified and as directed by Engr-in-charge. |
| 34 | M&L for dismantling of Cross Arms of MS Channels or angle section, clamps and back plates etc complete incl setting aside and Re-use same (if/any usable) with in 50 meter fixed atPCC Poles/two pole or four pole steel tubular poles structure complete all as specified and as directed by Engr-in-charge. |
| 35 | M&L for dismantling of insulators of any type/ size along with fixing clamps and Re-use the same ( if /any serviceable insulators) at newly installed Steel tubular pole incl disconnecting the electrical connection from line complete all as specified and as directed by Engr-in-charge. |
| 36 | M&L for dismantling of Old Existing GI Pipe of any size/type complete incl setting aside and Re-use same with in 50 Meter incl fixed the GI Pipe with suitable size of Clamps and accessories.Note : the rate quoted by contractor is deemed to be inclusive of fixing clamps and removal of old existing pipe and Reuse same for protection of cable in trenches/Road/ along the poles complete all as specified and as directed by Engr-in-charge. |