| 1 | DESCRIPTION OF ITEMS |
| 2 | Material and Labour in replacement ofsingle phase preventor 415V, 3P , 50 hz including electric connectioncomplete all as specified and directed. |
| 3 | Material and Labour in replacement of Contactor MNX 40 A, 3P and Front Mountingall as specified and directed. |
| 4 | Material and Labour in replacement of Contactor MNX 25A, 3P and Front Mounting Add-on aux. Contact Block MNX 2 NO + 2 NC all as specified and directed. |
| 5 | Material and Labour in replacement of Contactor MNX 325A, 3P and Front MountingContact Block MNX 2 NO + 2 NC all as specified and directed. |
| 6 | Material and Labour in replacement of Contactor MNX 250, 3P and Front Mounting Contact Block MNX 2 NO + 2 NC all as specified and directed. |
| 7 | Material and Labour in replacement of Contactor MNX 300, 3P and Front Mounting Contact Block MNX 2 NO + 2 NC all as specified and directed. |
| 8 | Material and Labour in replacement of Contactor MNX 185, 3P and Front Mounting Contact Block MNX 2 NO + 2 NC all as specified and directed. |
| 9 | Material and Labour in replacement of three pole contactor ML 12 suitable for 150/100HP star delta starter including electric connectioncomplete all as specified and directed. |
| 10 | Material and Labour in replacement of Over load relay 24-40A,MN2all as specified and directed. |
| 11 | Material and Labour in replacement of MO contactor 35-45 ARTO-1 all as specified and directed. |
| 12 | Material and Labour in replacement of Electronic overload Relay 9-45 Aall as specified and directed. |
| 13 | Material and Labour in replacement of Electronic motor protection Relay 16-44A 240v AC all as specified and directed. |
| 14 | Supply and fixing in replacement of415V 10KA \"C\" curve miniature circuit breaker (MCB) of 63 Amp Triple poleall as specified and directed. |
| 15 | Supply and fixing in replacement ofMCCB 63 A 3 Pole 415V ,50Hz breaking capacity 25KA all as specified and directed. |
| 16 | Supply and fixing in replacement ofMCCB 100 A3 Pole415V ,50Hz breaking capacity 25KA all as specified and directed. |
| 17 | Supply and fixing in replacement ofMCCB 160 A3 Pole 415V ,50Hz breaking capacity 25KA all as specified and directed. |
| 18 | Supply and fixing in replacement ofMCCB 250 A4 Pole 415V ,50Hz breaking capacity 36KA all as specified and directed. |
| 19 | Supply and fixing in replacement ofMCCB 400 A 4 pole 415V ,50Hz breaking capacity 36KA all as specified and directed. |
| 20 | Supply and fixing in replacement of ManualOn Load changeover Switch 315/320 A 4 pole 415V ,50Hzall as specified and directed. |
| 21 | Supply and fixing in replacement of Off Load changeover Switch with sheet meatal Enclouser400A 4 pole 415V ,50Hzall as specified and directed. |
| 22 | Supply and fixing in replacement ofMicon 175 Star Delta Timer 240 V all as specified and directed. |
| 23 | Cutting ofbushes , grass, small trees at water supplyinstallations or where directed as per requirement and disposal of the same to a distance not exceeding 50 mtr all as directed. |
| 24 | Supply and laying in replacement of high voltage insulation mat (blue in colour) made of elastomeric polymers material having a high insulation resistance, thus imparting total safety of human being from any leakage current, having high insulation resistance of class B of size 2.5 mm thick and 1.0 m width LT grade confirming to IS - 15652 : 2006, including pasting of mat with SR-998 by adding thinner as per requirement complete all as specified and directed. |
| 25 | Material and Labourfordismantling of main gear box assembly mounted on sedimention tank and cleaning, overhauling,greasing and replacement of gear oil approx 10 ltr , lathe work on Gear drum/pininon and shaft wheel gear with proper alignmentand refixing in same location including testing complete all as directed. |
| 26 | M & L for preparation of old painted surface of panels, 150/250/300 mm pipe lines, railing and Chaqured plate etc and protect meters, switches, duct cover from painting and paint with spray gun with one coat ofpaint complete all as specified and directed. |
| 27 | M & L for preparation of old painted surface with the help of paint remover, scrapper & fine ambery paper and painting with two coat of heat resistance paint with the help of spray gun on 150/120/100/75 HP Centrifugal pump set including motor, and writing SM No/ Maching No and connect back all Electrical connection and testing complete all as specified and directed. |
| 28 | M & L for preparation of old painted surface with the help of paint remover, scrapper & fine ambery paper and painting with two coat of heat resistance paint with the help of spray gunon 30/15/12.50/10 HP Centrifugal pump set including motor, and writing SM No/ Maching No and connect back all Electrical connection and testing complete all as specified and directed. |
| 29 | M & L for preparation of old painted surface with the help of paint remover, scrapper & fine ambery paper and painting with tow coat of heat resistance paint with the help of spray gunon 5/3/1/0.50HP Centrifugal pump set including motor, and writing SM No/ Maching No and connect back all Electrical connection and testing complete all as specified and directed. |
| 30 | Material and Labourfor preparation of old painted surface and applyingone coat of synthetic enamel paint ( existing colour ) first qualityonNRV /Sluice valve of any size complete all as specified and directed. |
| 31 | Material and Labour for disconnecting motor 150 HP all electrical connections , removing the motor from the base and opening upthe motor carefully and cleaning, servicing,greasingincluding varnishing complete, heating,replacement of worn out bearing with reassembling, mounting the same,includingtesting onfull load up to entire satisfaction, complete all as directed .Note:- (i)The cost of bearing rates shall be measured and paid separately.(ii) other Spare partsshall be measured and paid separately under respective items |
| 32 | All as per Item No 30 above but 125 HP |
| 33 | All as per Item No 30 above but 100/75 HP |
| 34 | All as per Item No 30 above but30/25 HP |
| 35 | All as per Item No 30 above but 3/5 HP |
| 36 | All as per Item No 30 above but 0.5/1.0 HP |
| 37 | Material and Labourfor disconnecting all electrical connections , removing the pump 150 HP from the base and opening upthe pump carefully and overhauling , cleaning, servicing, greasing and including replacement of worn out bearing,worn out gland bush,and reassembling, mounting the same, includingtesting onfull load up to entire satisfaction , complete all as directed.Note:- (i)The cost of bearing rates shall be measured and paid separately.(ii) other Spare partsshall be measured and paid separately under respective items |
| 38 | All as per Item No 36 above but 125 HP |
| 39 | All as per Item No 36 above but 100/75 HP |
| 40 | All as per Item No 36 above but 30/25 HP |
| 41 | All as per Item No 36 above but 5..0/7.5 HP |
| 42 | Supply onlyheavy duty grease all as specified and directed. |
| 43 | Supply only Gland of Size 06 mm all as specified and directed |
| 44 | Supply only Gland of Size 10mm all as specified and directed |
| 45 | Supply only Gland of Size 12mm all as specified and directed |
| 46 | Supplyand Fixing in replacement ofPVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core of 120 Sqmm size from LT panel to starter and starter to motor including crimping of copper lugs -06 nos, complete all as directed. |
| 47 | All as per Item No 45 above but 150 Sqmm size complete all as directed. |
| 48 | Supply and Fixing in repair neon blub indicating lamp assembly complete all as directed. |
| 49 | Supply and Fixing in repair suitable selector switch for ammeter/voltmeter complete all as directed. |
| 50 | Supply and Fixing in replacement Digital type Volt meter (0-500V) flush mounted three phase class 1.0 size ofsize 96x96 sqmm complete all as specified and directed. |
| 51 | All as per Item No. 49above but Digital Type (0-600A)Amp meter. |
| 52 | Supply and Fixing in replacement of Current transformer (CT) of range 100/5 A complete all as specified and directed. |
| 53 | Earthing complete with galvanised steel earth plate electrode 600x600x6 mm, burried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of platevertically to a depth not less than 1.5m below ground level, connected to galvanised steel strip32x6 mm dia of any length as required at site,by means of bolts, nuts, check nuts and washers of galvanised steel, earth lead wire encased in and including 40mm bore GI medium grade pipe for protection of G I strip 20 mm dia watering pipe medium grade including charcoal dust and common salt packed all around the earth plate, including necessary excavation and earth work in any type of soil /strata all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. all as specified. Note :(i) Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner. |
| 54 | Supply and Fixingin replacement GI strip 32 x 6 mm complete laid in trenches / ducts fixed on steel structure complete all as specified and directed. |
| 55 | Material and Labour foropening upthe motor 150 HP carefully and removing burnt windings from stator and rewinding with suitable gauge of supper enamelled copper insulated wire and superior insulating material including varnishing, heating, greasing replacement of worn out bearing, reassembling the same,includingtesting onfull load up to entire satisfaction,complete all as directed . |
| 56 | All as per Item No 54 above but 125HP |
| 57 | All as per Item No 54 above but 100/75HP |
| 58 | All as per Item No 54 above but 30/25 HP |
| 59 | All as per Item No 54 above but 10/12.5HP |
| 60 | All as per Item No 54 above but 2.5/3/5 HP |
| 61 | All as per Item No 54 above but 0.5/1.0 HP |
| 62 | Supply and fixing in replacement of MS coupling set including rubber bush and MS nut/bolts suitable for 100 to 150 HP Pump complete all as directed. |
| 63 | S&F in replacement MS coupling set suitable for 30/25 HP Pump complete all as directed. |
| 64 | S&Fin replacement sieve coupling beltsuitable for 7.5 HP Pump complete all as directed. |
| 65 | S&Fin replacement sieve coupling beltsuitable for 30/25/20 HP Pump complete all as directed. |
| 66 | S&F in replacement of coupling rubber bush -12Nos with MS nut bolts suitable for 100 to 150 HP Pump complete all as directed. |
| 67 | S&Fin repair pump bearing No 2310 complete suitable for 100 to 150 HP complete all as specified and directed. |
| 68 | S&F in repair motor bearing No NU316 complete suitable for 100 to 150 HP all as specified and directed. |
| 69 | S&F in repair pump bearing No 7310 complete suitable for 100 to 150 HP complete all as specified and directed. |
| 70 | S&F in repair motor bearing No 6317 complete suitable for 100 to 150 HP complete all as specified and directed. |
| 71 | S&F in repair motor bearing No 6315 complete suitable for 100 to 150 HP complete all as specified and directed. |
| 72 | S&F in repairmotor bearing No 6310/6305/6306 complete suitable for 25/30 HP all as specified and directed. |
| 73 | S&F in replacement of stainless steel shaft with check nut etc complete suitable for 100 to 150 HP centrifugal pump complete all as specified and directed. |
| 74 | S&F in replacement of stainless steel shaft with check nut etc complete suitable for 30/25 HP centrifugal pump complete all as specified and directed. |
| 75 | S&F in replacement ofinter stage gunmetal/ brass bush complete suitable for 100 to 150 HPcentrifugal pump complete all as specified and directed. |
| 76 | S&F in replacement ofboth end long gunmetal/ brass bush complete suitable for 100 to 150 HP centrifugal pump complete all as specified and directed. |
| 77 | Supply only pressure plate with balancing disc suitable for 100 to 150 HP centrifugal pump complete all as specified and directed. |
| 78 | S&F in replacement ofgun metal impeller complete set suitable for 100 to 150 HP centrifugal pump complete all as specified and directed. |
| 79 | S&F in replacement ofgun metal impeller completeSet suitable for 25/30 HP centrifugal pump complete all as specified and directed. |
| 80 | Material and Labourin replacement of glands suitable for 100 to 150 HP centrifugal pump complete all as specified and directed. |
| 81 | Material and Labour inreplacement of glands suitable for 30/25HP centrifugal pump complete all as specified. |
| 82 | Supply and Fixing in replacement pressure gauge range 0 to 400 kg/cm2 of suitable size for 100 to 150 HP pump set complete all as specified and directed. |
| 83 | Supply and Fixingin replacement pressure gauge range 0to 200 kg/cm2 of suitable size for 30/25/5/3 HP pump set complete all as specified and directed. |
| 84 | Repair/ Replacement of fan belt of existing size and dia of main gear assy mounted on sediment tank complete all as directed. |
| 85 | Supply and Fixingin replacement Copper Cable lugs of size 120 Sqmm for connection to copper cable complete all as specified and directed. |
| 86 | Supply and Fixing in replacement Copper Cable lugs of size 150 Sqmm for connection to copper cable complete all as specified and directed. |
| 87 | Supply and Fixingin replacement Cable lugs of size 70 Sqmm for connection to copper cable complete all as specified and directed. |
| 88 | S&F in replacement of bearing housing RKB23 of make Kirloskar pump with existing size 120/150 HP pump complete all as specified and directed. |
| 89 | S&F in replacement of Stainless steelmotor coupling guardwith existing size of pumps complete all as specified and directed. |
| 90 | S&F in replacement cast iron air valves with two air outlets, 150 mm dia bore and fixing in cast iron water supply mains including all fixing arrangement complet all as specified and directed. |
| 91 | M&L in repair including jointing and testing of CI wedge gate sluice valves of 150mm dia class 300 Type,bolted bonnet outside screw & Yoke type rising stem, ISI marked, flanged ends, drilled having stainless steel spindle with cast iron wheel at top complete with nut bolts, washer and rubber gasket complete all as specified . |
| 92 | Supply and Fix in replacement of 150 mm diaSluice valve both end flanged class PN-10 non rising type complete with stainless Steel spindles check nut CI wheel including all fixing arrangements complete all as specified and as directed. |
| 93 | Supply and Fix in replacement of 100 mm diacost iron foot valve swing type both end flangedincluding all fixing arrangements complete all as specified and as directed. |
| 94 | Supply and Fix in replacement of 150 mm diacost iron foot valve swing type both end flangedincluding all fixing arrangements complete all as specified and as directed. |
| 95 | M&L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in Foundation of Pumps including necessary form work completeall as specified and directed.Note :Foundation of Pump grounting nuts & bolts for pumps included in the qouted rates. |
| 96 | M&L for fabrication of MS channel base frame for motor and pump as per existing size including welding,leveling alignment & testing of electric moter,pump or Air compressure including nut & bolts all as directed by Engr in charge. |
| 97 | S&F in replacement ofSS retro reflective blue background white letters sign board for thickness 3/6 mm rectangular in shape with standard designincluding all fixing arrangement complet all as specified and directed. |
| 98 | Supply and fixingin replacement of pump machanical seal type of NBM-3 and size 74.mm including all fixing arrangement complet all as specified and directed. |
| 99 | Repair of casing complete set ofpump with existing size 120/150 HP pump complete all as specified and directed. |
| 100 | S&F in replacement of oil seal pump with existing size 120/150 HP pump complete all as specified and directed. |
| 101 | S&F in replacement of greas platepump with existing size 120/150 HP pump complete all as specified and directed. |
| 102 | S&F in replacement oflong sleevpump with comlete set of existing size 120/150 HP pump complete all as specified and directed. |
| 103 | S&F in replacement of small sleevpump with complete set ofexisting size 120/150 HP pump complete all as specified and directed. |
| 104 | S&F in replacement of Rubber ringpump with complete set ofexisting size 120/150 HP pump complete all as specified and directed. |
| 105 | Excavation in trenchesnot exceeding 1.5m wide and not exceeding 1.5 M. depth for LT cable nd getting out in hard/dense soil, comlete all as specified and directed. |
| 106 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. |
| 107 | Removing excavated soil to a distance exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point , complete all as specified and directed. |
| 108 | M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after laying of cable in trenches complete all as specified and directed. |
| 109 | M&L for protection to cable using old size sub class \" B\" bricks, laid flat, dry butt jointed, laid lenthwise perpendicular to the axis of cable all as specified and directed. |
| 110 | Supply and laying in replacement of XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 185 sqmm 3.5 core complete all as specified and directed. |
| 111 | Dismantling old Panel and Supply & Fixing 25 HP Softstarter panel(1w+1s) factory made , floor mounted, made of CRCA sheet powder caoted 2.0 mm, detachable type fixed with nuts and bolt and front door fixed with hinges and knobs, suitable for 3 phase 415 volts, 50Hz AC supply complete as as specified and directed comprising of the following :-(a) 100 A 4P 36 KA MCCB, TMD Release, Type : EasyPact CVS - 01 Nos (b) Standard extended rotary handle for EasyPact CVS 100/160/250A - 01 Nos (c) Spreader Links (Set of 4) 4P for EasyPact CVS 100A - 02 Nos (d) Three Phase Voltmeter, Acc CI: 1.0, Model : DM3210 - 01 Nos (e) Three phase Ammeter, Acc CI:1.0 Model: 3110 - 01 Nos (f) 100/5A Acc. CI:1 15VA Resin Cast Ring Type Current Transforme, Round Dia : 30mm - 03 Nos (g)Yellow Direct Intergal LED indicating lamp, Voltage : 230 V AC - 01 Nos (h) Blue Direct Intergal LED indicating lamp, Voltage : 230 V AC -01 Nos(i) 50A 36 KA MCCB, TMD Release, type : Easy Pact CVS -02 Nos Contd.... |
| 112 | (j) Standard extended rotary handle for EasyPact CVS 100/160/250A - 02 Nos(k) 18.5 KW Soft Starter for Motor Delta Connection, Supply Voltage : 230-440 V AC, Type: ATS22 - 02 Nos(l) 10A Auxiliary Contactor, Coil:220V AC, Aux. Contact: 2 NO+2NC, Typ : CAE - 02 Nos(m) Green Flush Type Spring Return Push Button, Contacts:1 No - 02 Nos(n) Red Flush Type Spring Return Push Button, Contacts: 1NC - 02 Nos(o) Standard Single Contact blocks 1 NO - 02 Nos(p) Standard Single Contact blocks 1 NC - 02 Nos(q)Red Direct Intergal LED indicating lamp, Voltage : 230 V AC - 03 Nos(r) Green Direct Intergal LED indicating lamp, Voltage : 230 V AC - 02 Nos(s) Amber Direct Intergal LEd indicating lamp, Voltage : 230 V AC - 02 Nos(t) 6A 1P 2 Way Local - Remote/Auto-Manual Switch without OFF, 90 Deg Operation Complete Rotation - 02 Nos(u) 6A 1P 10 KA C -Curve MCB, Type: xC60- 06 NosNote :- Old Panel shall be deposited in MES store yard. |
| 113 | Supply & Fixing in replacement of 150 HP Automatic Star Delta starter panel factory made, floor mounted, made of CRCA sheet powder caoted 2.0 mm, detachable type fixed with nuts and bolt and front door fixed with hinges and knobs, suitable for 3 Phase 415 Volts, 50 Hz AC supply complete as specified and directed comprising of the following:-(a) MCCB 300 Amps 35 KA TP (Make-L&T/Schenider/Siemens) - 01 No(b) Three pole contactor ML 10 -02 Nos (Make-L&T/Schenider/Siemens)(c) Three pole contactor ML 12 -02 Nos (Make-L&T/Schenider/Siemens)(d) Single Phase Preventor (Make-L&T/Schenider/Siemens) - 01 No(e) Bimetal overload Relay (90-150 Amp) (Make-L&T/Schenider/Siemens) - 01 No(f) Indicating light On, Off (Make-L&T/Schenider/Siemens) - 02 Nos(g) Phase indicating lamp R,Y,B (Make-L&T/Schenider/Siemens) - 03 Nos(h) Digital Amp Meter (0-300 Amp) (Make-L&T/Schenider/Siemens) - 01 No Contd..... |
| 114 | (j) Digital Volt Meter (0-500 Volt) (Make-L&T/Schenider/Siemens) - 01 No(k) Amp Meter Selector Switch (Make-L&T/Schenider/Siemens) - 01 No(l) Volt Meter Selector Switch (Make-L&T/Schenider/Siemens) - 01 No(m) CT 300/5 (Make - AE) - 03 Nos(n) Motor protection automatic phase sequence corrector time delay circuit sigle phase preventor with facility to change over from automatic to manual with contactors suitable for150 Hp motor, protection fuse etc - 01 NoNote :- Old Panel shall be deposited in MES store yard. |
| 115 | Note : Tenderers may note that amount of credit Rs 1,16,060.20 will be deducted from the total amount arrived, at the time of Acceptance of contract. |