| 1 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft /loose soil. |
| 2 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m deep for foundation and getting out in soft/loose soil complete all as specified and directed |
| 3 | M&L for cement concrete type D-2, 1:4:8in Cement concrete (40 mm graded aggregate ) in foundations, filling and mass concrete complete all as specified and directed |
| 4 | S&F of Mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated conforming to Fe 290 gde E 165) |
| 5 | S&F of Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections complete all as specified and directed |
| 6 | S&F of Roof trusses (framed), trussed, purlins, crane gantries, rails and fasteningsand heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 7 | M&L for preparation of newly steel surface of any description, over 10cm in width or girth,not otherwise described applying two coats of synthetic enamel paint over one coat of red oxide primer. |
| 8 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete all as specified and directed |
| 9 | Returning/filling in including spreading, levelling, watering and well remming in layers n.exc 25 cm in soft/loose soil. |
| 10 | Removing excavated material n.exc 50m and depositing where directed at a level n exc 1.5m above the starting point. |
| 11 | M&L for Hardcore of gauge n exc. 63 mm, with broken stone/ boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed |
| 12 | M&L for PCC 100mm thick, type D-2, 1:4:8 (using 40mm graded stone agg) infloors and pavings etc. complete all as specified and directed |
| 13 | M&L for PCC40 mm thick, type B-1, 1:2:4 (using 20mm graded stone agg) infloors and pavings etc. and finishing surfaces even and smooth with out using extra cement complete all as specified and directed |
| 14 | M&L for Glass dividing strips, 3 mm thick 38mm wide for constraction and expension jointscomplete all as specified and directed |
| 15 | M&L for plain cement concrete 75mm thick type C-2, 1:3:6, (40mm graded stone aggregate) as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement. |
| 16 | M&L rendering 10 mm thick in CM 1:6on concrete inner surfaces of wallfinished even and smooth without using extra cement . |
| 17 | Material and labour for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer all as specified. |
| 18 | M&L rendering mixed with liquid wpc by 0.4% of cement weight 15mm thick in CM 1:4on concrete outer surfaces finished even and smooth without using extra cement . |
| 19 | Supply only of Liquid water proofing compound for exteenal plastering complete all as specified and directed |
| 20 | M&L for Prepairing surfaces plastered or unplastered newly surfaces with two coats of cement base paint over Primimg coat complete all as specified and directed by engr in charge |
| 21 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 22 | S&F offor Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 23 | Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated,heavy duty electric cableswith Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of following cross-sectional area including removing/ taking down of old unserviceable cables:- 10 Sqmm 2 Core |
| 24 | 16 Sqmm 2 Core |
| 25 | 25 Sqmm 4 Core |
| 26 | 35 Sqmm 3.5 Core |
| 27 | 50 Sqmm 3.5 Core |
| 28 | 70 Sqmm 3.5 Core |
| 29 | S&F Double walled corrugated (DWC) Pipe conforming to IS 14930(Part-II) Pipesof Outer dia 50 mm and inner dia 38mmall as specified and as directed. |
| 30 | S&F Double walled corrugated (DWC) Pipe conforming to IS 14930(Part-II) Pipesof Outer dia 63 mm and inner dia 50mmall as specified and as directed. |
| 31 | Supply and fixing in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protectionincluding removing of old unserviceable street light complete. |
| 32 | S&F MCB SP 5 to 32 Amps 240 volts \"C\" series, 10 KA, 50 Hz including connection in the DB and testing/commissioning.Make:- As approved Make of DB |
| 33 | S&F PVC Junction box sheet moulding compound type (SMC) off white colour with hinged type door of size 250 x 200 x 100mm (internal) comprising bakelite 16 sqmm size terminal block 4 ways-1 No, MCB SPN - 01 No housed inside junction box with neutral bus bar, internally wired, complete fixed on pole with suitable MS clamps bolts nuts and washers including taking out old junction box all as specified and as directed.Make:-Sintex/Prayag/Indoasian |
| 34 | M & L for cable route marker with route indication on cast iron disc of 100mm dia and 10mm thick, marked / written for \"LT CABLE 1100 VOLTS\" embosed including indicating direction fixed / bolted to 40mmx40mmx6mm thick MS angle iron support of 0.5m long embedded upto 200mm depth in concrete block of size 200mm x 200mm x 500mm of mix PCC 1:3:6, type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surfaces complete all as specified and directed. |
| 35 | Supply, installation, commissioning and testing in replacementpowder coated factory made out door type double door panel board confirming to IP 66 protaction, of suitable size made of Robust steel sheet construction made from min 3.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, pedastal type and provided with four nos of angle iron supports duly embedded in foundation using PCC (1:2:4) type C-1 with 20mm graded stone aggregate.The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:- (a) Al bus bar of suitable capacity for phase and neutral.(b) Incoming MCCB 4 pole 250 Amp 36 KA alongwith Spreader terminals with adjustable thermal setting– 01 No(c) Out going MCCB 4 pole 125 Amp 25 KA alongwith Spreader terminals with adjustable thermal setting– 04 Nos(d)Digital volt meter 0 to 500 volt with selector switch – 01 No(e)Digital Amp meter 0 to 500 Amp with CT of suitable ratio and selector switch – 01 No |
| 36 | Supply, installation, commissioning and testing in replacementpowder coated factory made out door type double door Feeder panel board confirming to IP 66 protaction, of suitable size made of Robust steel sheet construction made from min 3.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, pedastal type and provided with four nos of angle iron supports duly embedded in foundation using PCC (1:2:4) type C-1 with 20mm graded stone aggregate.The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:- (a) Al bus bar of suitable capacity for phase and neutral.(b) Incoming MCCB 4 pole 125 Amp 25 KA alongwith Spreader terminals with adjustable thermal setting– 01 No(c) Out going MCCB 4 pole 100 Amp 16 KA alongwith Spreader terminals with adjustable thermal setting– 01 No |
| 37 | M/L for point wiring in casing caping with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl casing caping with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for One light/fan point controlled by one No piano type switch5 Amps single pole one way |
| 38 | S&F ceiling rose surfacebakelite 65mmx50mm 100watt three terminal. |
| 39 | S&F Switch Piano Flush button single pole one way 5/6 Amp. |
| 40 | S&F sheet metal enclosure double door for MCB DB single pole and neutral 4 way with 200 Amps rated bus bar 240 volts double door (Metallic) type including taking down old unserviceable MCB DB with MCBs. |
| 41 | S&F MCB SPN 40 Amps 240 volts \"C\" series, 10 KA, 50 Hz.Make:- As approved Make of DB |
| 42 | S&F MCB SP 5 to 32 Amps 240 volts \"C\" series, 10 KA, 50 Hz including connection in the DB and testing/commissioning.Make:- As approved Make of DB |
| 43 | S&F LED light fitting 1x9w bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable sze. |
| 44 | Supply and fixing LED lights fitting 1x 18W, 4 feet, 220V,AC decorative box type with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 45 | Supply and fixing LED light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 46 | S&F of 1100 volt grade heavy duty ISI marked cable PVC insulated multi stranded aluminium conducttor one twin core flat or circular of size 10 Sqmm served with inner sheating of PVC sheated in service connection of size 10 Sqmm 2 core.heavy duty electric cable with aluminium conductor, 1100 volts grade of size 10 sqmm 2 core complete all as specified and directed by Engineer in charge. |
| 47 | Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanised earth lead wire 4.0mm diaby means of bolts, nuts, check nuts and washers ofgalvanizediron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC(1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduitgrouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete including taking out old unserviceable earthing materials all as specified and as directed. |