| 1 | Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish of the premises complete all as specified & as directed. |
| 2 | Demolition of cement concrete in ground floors and paving n.exc 15cm thickness (below orabove ground level) complete all as specified & as directed. |
| 3 | Taking down cement plaster on brick or stone walls etc including racking out joints hacking for key, scrubbing down with water etc complete all as specified & as directed. |
| 4 | Dismantling structural steel work including doors, gates, rolling shutters, etc. but excluding framed truss etc complete all as specified and directed. |
| 5 | Dismantling of asbestos cement (corrugated, semi-corrugated,etc.)or steelsheets in roof coverings complete all as specified & as directed. |
| 6 | S & F in repair Steel rolling shutters, 1.00 mm thick, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified & as directed. |
| 7 | S & F Safety lever locks mild steel with 4 levers for rolling shutterscomplete all as specified & as directed. |
| 8 | S & F Ball bearing for rolling shutters complete all as specified & as directed. |
| 9 | Taking down chowkhats or frames with shutters n.exc.1.5 sqm (Without taking off shutters from the frame) and removing to or from complete all as specified and directed. |
| 10 | Taking down chowkhats or frames with shutters exc.1.5 sqm but N.exc 4 Sqm(Without taking off shutters from the frame) and removing to or from complete all as specified and directed. |
| 11 | M & L for hacking out old broken glass from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified & as directed. |
| 12 | S & F3 mm thickglass of ordinary quality, ordinary quality and glazing with oil putty in square n. exc 0.5 sqm complete all as specified & as directed. |
| 13 | S&F inaluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed. |
| 14 | M & L for Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 15 | S&F Steel work in tubular trusses (round/rectangular/square shape of pipes as approved by Engr-in-Charge) complete etc using ERW or induction butt weld M.S tube black conforming to IS 1161-1979 grade Yst 240 as in purlin, rafter, pole including special shaped, washers, fabrication and election complete all as specified. |
| 16 | S&F coloured Glazed ceramic tiles in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in CM 1:3 complete all as specified & as directed. |
| 17 | M &L for Non - skid Ceramic,coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:4 complete all as specified. |
| 18 | S & F 15 mm bore Unplasticiscd PVC pipes of pressure rating 10 kgf/cm2 laid in trenches complete all as specified. |
| 19 | S & F 20 mm bore Unplasticiscd PVC pipes of pressure rating 10 kgf/cm2 laid in trenches complete all as specified. |
| 20 | S & F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified. |
| 21 | S&F in repair low level flushing cistern plastic valve less syphonic action type white with inlet ball valve float chain and ball bracket & capacity 10 ltr ISI marked make commerder including 32mm PVC flush pipe complete all as specified & as directed. |
| 22 | S&Finin repair quarter turn bib tap 15 mm dia chromium plated cast copper alloy with crutch orbutter fly handle screwed down screwed for iron pipe complete all as specified & as directed. |
| 23 | S&F in reapair quarter turn stop cock valves 15 mm cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unious complete all as specified & as directed. |
| 24 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with ruberring jointsfixed to wall complete all as specified & as directed. |
| 25 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with ruberring jointsfixed to wall complete all as specified & as directed. |
| 26 | S&F PVC (SWR) bends 110mm bore in mm any radius with access door complete all as specified & as directed. |
| 27 | S&F PVC (SWR) bend 75mm bore anyredious with access door complete all as specified & as directed. |
| 28 | S&F PVC (SWR) 110mm bore WC connector with liptype ring complete all as specified & as directed. |
| 29 | S&F PVC (SWR) 75mm diameter out let in mm floor trap, plain withgrating including jointing with solvent cement. complete all as specified & as directed. |
| 30 | S&F PVC (SWR) 110mm bore in mmvent cowl complete all as specified & as directed. |
| 31 | S&F PVC(SWR) 75mm bore in mm vent cow complete all as specified & as directed. |
| 32 | Taking down carefully existing bitumen tarfelt including coba,plaster of any description over the surface of roof, terracess including flashings and junctions of parapete/ curbwalls etc and removing of the rubbish to a distance exceding 500m but nexc 1.00km and depositing where directed |
| 33 | M&L for PCC 1:2:4 B-0 using 12.5mm graded aggregate as in filleting and benching slightly rounded etc including necessary formwork complete. |
| 34 | M&L for PCC 1:2:4 B-0 25mm thick using 12.5mm gradedstone aggregateas in padding concrete on roof slab.all as specified |
| 35 | M/L forrendering 10 mm thick on CM (1:3) on concrete roof top and chajjas surface finished even and smooth to getuniform level surface forlaying of membrane treatement,with using water proofing compound complete all as specified & as directed. |
| 36 | M&L for preparing, clean and dry plastered roof surfaces and applying APP modified water proofing membrane mineral finish with non woven polyster reinforcement/mat not less than 3mm thick having weight not less than 3kg/Sqm including and surface painting, with a layer of blown grade bitumen confirming to IS :3384applied@ .250 kg per sq.m, all as per manufacturers instructions complete all as specified and as directed. |
| 37 | M&L for rendering5mm thick incm 1:3 on fair faces of concrete as in soffit ceiling of slab, chajjas finished even &smooth without usingextra cement complete all as specified & as directed. |
| 38 | M&L for rendering 10mm thick incm 1:6 on fair faces of brick work or concretesurfaces of wall and finishing thesurface with neeru etc complete all as specified. |
| 39 | M & L for rendering 15 mm thick in cement mortar 1:4 (10 mm thick backing coat and 5 mm thick finishing coat) on fair faces of brick work or concrete surfacesincluding finished even and smooth without using extra cementwith using water proofing compound (water proofing compound shall be measured and paid seperately) |
| 40 | Supply only integral water proofing compound of approved make |
| 41 | M & L preparation of plastered or unplastered new surfaces of walls and applying three coats of white wash on Walls complete all as specified. |
| 42 | M & L preparation of plastered or unplastered new surfaces of ceilings and applying three coats of white wash on ceilings complete all as specified. |
| 43 | M&L for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot tinted) with silicon additives @ 1.43 Litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new surfaces in camouflage pattern of different shades complete all as specified and as directed. |
| 44 | M & L preparation of plastered or unplastered old surfaces of walls and applying two coats of white wash on Wallscomplete all as specified. |
| 45 | M & L preparation of plastered or unplastered old surfaces of ceiling and applying two coats of white washcomplete all as specified. |
| 46 | M&L for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot tinted) with silicon additives @ 1.43 Litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm in camouflage pattern of different shades over old surfaces complete all as specified and as directed. |
| 47 | M & L for machine cut kota stone slab flooring 20-25mm thick over 20 mm thick cement screed (1:6 ) baselaid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 48 | M & L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and including 10 mm thick rendering in in CM 1:3 complete all as specified |
| 49 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing |
| 50 | S&F Factory made solid panel pace door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C\" channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. |
| 51 | S&F but hinges stainless steel 100mm long.complete all as specified & as directed. |
| 52 | S& F Aluminium anodised barrel tower bolts150mm long of extruded section and fixed complete all as specified and directed. |
| 53 | S & F 150mm size extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed. |
| 54 | M&L powder coated aluminium Door/ window/ sliding window / Ventilator / partition frames and shutters using standard aluminium powder coated sections including necessary joining cleats, glazing clips, rubber packing anodised aluminium snap beading, screws, anodised aluminium fittings suitable Nylon gasket, nylon rollers, maruthi locks, handles, concealed star lock, aluminium F channel for fixing aluminium grill and all necessary fittings and fixtures etc all as specified etc complete of standard sections and fixing to cudappa stone/granite stone with necessary bolts/screws complete directed. |
| 55 | S&F aluminium anodized grill of 4.75 x 7.75 mm, size ofopening 10cm,size of mesh RG 103 (as per royal grill) with aluminium channel `F\" angle 20mmx15mm fixed to aluminium frame work all as directed. |
| 56 | S & F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed |
| 57 | M & L for powder coatedaluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beadingscrews etc. complete all as specified |
| 58 | S&F for framed work as in plates (plain or chequred) channels, square cut or notched with fabricationand erection of FE 410-W (Gde E-250) auality A (ordinary and counter sunk) forming holes without any attachment. |
| 59 | M&L for two coat of synthetic enamel paint over a coat of red oxide primer over newely untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described etc complete. |
| 60 | Material and labour for post construction anti termite treatmentunderexisting floorsurface of any description using emulsion by injection methord (300 mm centre to centre hole destance) by means of mechanical injucter at the rate ofone litre per hole of emulsion including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 Cement: 2 Coarse sand) to match the existing holes complete all as specified and as directed. |
| 61 | Material and labour for post construction anti termite treatment along the external wall below concrete or masonry apron using emulsion by injection methord (300 mm centre to centre hole destance)by means of mechanical injucter at the rate of2.25 litres of emulsion per linear metre including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 Cement: 2 Coarse sand) to match the existing holes complete all as specified and as directed. |
| 62 | M & L for 75 mm thick PCC 1:3:6 type C2 using 40 mm graded crushed stone agg complete all as specified. |
| 63 | M & L for 75 mm thick PCC 1:2:4type B2 using 40 mm graded crushed stone agg complete all as specified. |
| 64 | M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified. |
| 65 | M & L for 80 mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigmentconfirming to IS 15658-2006 ,M-40 Grade complete all as specified. |
| 66 | M & L for white Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble complete all as specified. |
| 67 | S & F Sheet glass, 5.5 mm thick ordinary quality and glazing with oil putty in squareexc 0.5 sq. m in each pane complete all as specified. |
| 68 | M & L for rolled sections as in framing for cladding, glazing and thelike fixed with angle cleats and connecting plates, etc.FE 410-W (Gde E-250) |
| 69 | S&F sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm complete all as specified. |
| 70 | S & F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified. |
| 71 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified. |
| 72 | Returning, filling in , spreading, levelling, ramming, watering in layers not exc 25 cm complete all as specified & as directed. |
| 73 | Removing excavted material to a distance exc 200 m and n.exc 250 m and deposting where directed at a level n. exc 1.5 m above the starting point |
| 74 | Taking down copper/aluminum point wiring (light, fan, socket or power) complete and including (fitting and fixture such as switches, socket ,ceiling rose ,pendent ,regulators,light fittings, etc to be measured separetaly) NOTE:- Job including for taking out old gutties,screw,nails,casing caping/conduit etcand making good to disturbed surface of wall ,floor etc including to match with the existing surface. complete all as specified & as directed. |
| 75 | M & L for point wiring with 1.5 sq mm FRLS single core PVC insulated unsheathed 1100 V grade with multistranded copper conductor drawn through PVCconduit with all accessories concealed in thewall /roofsetc and incl provision of 1.5 sq mm PVC insulated and unsheathed copperconductor as earth continuity conductor and connected to common earth dollyall as s specified and directed for following. (a)one light/Fan point controlled by one switch complete all as specified & as directed. |
| 76 | (b) One socket 3 pin outlet 5 amp on independent board. |
| 77 | (c)One 3 pin socket outlet 5 amp on the same board with other switches. |
| 78 | All as per item No 75 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm 2.5 sq mm copper cable as earth continuity conductor. |
| 79 | Supply & Fix in repair Switch piano, flush type single pole, one way 5 Ampcomplete all as specified. |
| 80 | Supply & Fix in repairswitch 15 Ampcomplete all as specified. |
| 81 | S & Fin repair ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified. |
| 82 | Supply & Fix in repair Socket outlet 2 in 1, 3 pin, 5 and 15amp flush typecomplete all as specified. |
| 83 | Supply & Fix in repair Socket outlet 2 in 1, 3 pin, 5A |
| 84 | S&F in repair stepped type electronic fan regulator flush type120 Won the existingphenolic laminated sheet etc. as reqd. |
| 85 | S&F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings |
| 86 | Supply & Fix in repair LED Batten for LED tube light with 01 Nos of LED tube 20 Watt fixed on two Nos of Square Block with twin core copper flexible wire and incltaking down old type tube light fitting etc all as directed. |
| 87 | S&F in replacement sub main wiring drawing through PVC conduit concealed in wall/roof with two single core 4 sq mm and one run of 4 sq mm as earth wire of FRLSHstranded copper conductor PVC insulated and unsheathed cable of 1100 volts gradeall as directed |
| 88 | S&Fin repair MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including taking down old Unsv DBs by dissconnecting of electrical coonection any type including connection in new DBs by using flexible pipe suitable size and making good and match with theexisting surface of wall etc all as specified and directed |
| 89 | S&Fin repair MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including taking down old Unsv DBs by dissconnecting of electrical coonection any type including connection in new DBs by using flexible pipe suitable size and making good and match with theexisting surface of wall etc all as specified and directed |
| 90 | Supply & Fixin repair MCB single pole and neutral 35-63 amps, 240 Volts, Complete all as specified and directed. |
| 91 | S&F in replacement of MCB 6 to 40 amps single pole 240 Volts, Complete all as specified and directed. |
| 92 | Supply and fixin repair exhaust fan 380 mm sweep single phase 230/240 V made ofsteel body with frame and louver shutter copper winding fixed in wall with nuts and bolts by making of suitable arrangement and making good complete all as specified and directed by engineer-in-charge. Note- Old ceiling fan to be deposited in MES store yard for safe custody. |
| 93 | Supply and fixin repair exhaust fan 450 mm sweep single phase 230/240 V made ofsteel body with frame and louver shutter copper winding fixed in wall with nuts and bolts by making of suitable arrangement and making good complete all as specified and directed by engineer-in-charge. Note- Old ceiling fan to be deposited in MES store yard for safe custody. |
| 94 | Supply and hanging /fixing in repair ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of \"B\" class insulation, single phase, minium 26W (± 10%), Temperature rise 40 degree maximum without remote with and including operative based capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified.Note :- (i) Sereial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.Note- Old ceiling fan to be deposited in MES store yard for safe custody. |
| 95 | S&F in replacement of aesthetically designed LED security light luminiareis of 35 watts system wattage for energy saving having IP 66 degree of protection,with minimum system efficiency as>85%,made ofpressure die casting aluminum housing power coated in graphite grey andheat resistant toughened glass with excellent thermal management LED should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light Fitting should have operating voltage range of 120-270 VAC,THD<10%,P.F>.95 The fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K including 40mm dia GI pipe light grade of 1.5mtr length with necessary clamp & nut bolts complete all as specified and directed. |
| 96 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as directed. |
| 97 | Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 98 | Taking out old unserviceable LT cable of any size any type from trench/duct/poles/ roof/pipe etc and keeping aside for segregation of serviceability. Serviceable cable will be re-laid at same place or other place as required. |
| 99 | Supply, Laying, testing & commissioningof UG LT cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2coreincluding connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends and necessary saddle clamp (heavy duty) , all as specified and directed by Engg-In-charge. |
| 100 | Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/ loose soil, for laying of under ground electric cable, pipes etc all as directed and specified. |
| 101 | M & L for river bed sand filling in trenches/ ducts 15 cm above cable and 8 cm under the cable for cushioning/protection to cable including spreading, leveling and get thick 18cm after hand punning complete all as specified and directed. |
| 102 | Supply & laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding10mm over under cable for protection complete all as specified & as directed. |
| 103 | Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed. |
| 104 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. |
| 105 | M&L in repairsub main wiring with 2 run single core multistranded copper conductor cable, of size 1.5Sqmm, PVC insulated, unsheathed, FRLSH drawn through and including heavy duty ERW steel conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 1.5 Sqmm, PVC insulated, unsheathed, fire retardant as earth wire, fixed on wall / ceiling complete including taking down old sub main wiring. Note: 02 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment. |
| 106 | S&F in repair/replacement for kiosk box for luminaries, weather proof made out of PVC/HDPE /FRP housing fire retardant, non fusing, shock & rust proof, single piece molded andcover with hinged door, pole mounting type comprising of aluminum TPNbus bar of 60 Amps of minimum inside size 200 x140 x 95mm, fixed on wall/pole with MS, clamps 30x5mm with necessary nuts, washer including 16 Amp MCB SP for out goining complete all as directed. Note. Rate of TPN bus bar and MS clamp inclusive in item rate. |
| 107 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicatedincluding testing on completion complete all as specified & as directed. |
| 108 | Taking down ceiling fan/Exhaust fan of any make and sweep, cleaning externally and internally including painting with synthetic enamel paint of existing colour. Stripping out the fans, examine the unserviceable spares, cleaning and lubricating bush/ bearings. Refixing the fans in same position after necessary servicing including carring out the replacement worn out parts, screws, spilt pins nuts condensor and flexible wire copper conductorr from ceiling fan to ceiling rose etc complete all asspecified and as directed. |
| 109 | M&L for point wiring for one light/Fan/socket 5Amps point on indep boardcontrolled by one, one way switch complete with two runs of 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FRLSH cable 1100 volts grade ISI marked drawn through and including heavy duty ERW conduit not less than 20 mm dia concealed type (including cutting, chasing and make good with painting of existing colour) including all accessories like bend, tees, junction boxes etc.including run 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly complete all as specified and directed by Engr-in-charge. Note : Point wiring will be done from Main DB. Length of point wiring may be beyond 5 mtrs and no extra amount for long point wiring will be considered. |
| 110 | M&L for point wiring for one socket16 Amps point on indep boardcontrolled by one, one way switch complete with two runs of 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FRLSH cable 1100 volts grade ISI marked drawn through and including heavy duty ERW conduit not less than 20 mm dia concealed type (including cutting, chasing and make good with painting of existing colour) including all accessories like bend, tees, junction boxes etc.including one run 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly complete all as specified and directed by Engr-in-charge. Note : Point wiring will be done from Main DB. Length of point wiring may be beyond 5 mtrs and no extra amount for long point wiring will be considered. |
| 111 | M&L for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6Sqmm, PVC insulated, unsheathed, FRLSH drawn through and including heavy duty ERW steel conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant as earth wire, fixed on wall / ceiling complete including taking down old sub main wiring. Note: 02 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment. |
| 112 | S&F in replacement switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed |
| 113 | S&Fin replacement Flame proof switch socket & plug combined in LM6 cable termination box in LM6,16A, 250V, 2P+earth complete all as specified and directed |
| 114 | Supply and fixin repair/replacement LED flame proof well glass in die cast aluminum housing with heat resistant toughened glass, 70watt , IP66 protected and including all accessories, connecting up with flexible copper conductor 1.5 Sqmm 3core covered with flexible metal conduit of suitable size complete all as specified and directed. |
| 115 | S&F flame proof, weather proof distribution board 6 way, Aluminum die cast alloy in LM6 material sheet metal enclosure including MCB 40 Amp, SPN (incomer) and 04 Nos SP 6-32 Amp (out going) terminal, wiring and all fitting accessories etc complete all as specified & directed. |
| 116 | M&L for sub main wiring with 2 run single core multistranded copper conductor cable, of size4 Sqmm, PVC insulated, unsheathed, FRLSH drawn through and including heavy duty ERW steel conduit concealed type not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant as earth wire, fixed on wall / ceiling complete including taking down old sub main wiring. Note: 02 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment. |