| 1 | M&L for mild steel framed work for made of angle iron with and including mild steel sheet as required/MS Square pipes/MS flange for GI Pipes including necessary welding, cutting, hinges, locking arrangments including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 2 | Taking out of borewell submersible pump of any type and capacity upto 12.5 HPalongwith column pipe and 3 core flat cable complete after disconnecting of all electric and water line connectionforany make of pump & motor up to 170mtr complete all as specified and directed |
| 3 | Dismantling of borewell submersible pump bowl assembly of any make and capacity and size complete( to be measured only after lifting carefully without damaging any parts of the pump and setting aside in Pump house/specified nearest location of ascertaining the serviceability of existing dismantled parts including reassembling pump complete all as specified and directed with the following works :-(a) Cleaning of completepump assembly parts, discharge case,impeller , Shaft suction casing bowls disc & bearing etc.(b) Checking of all rotary and statutory parts of pump bowl & stage casing assembly and making free for their satisfactory run, rewinding and reinsulation of motor and making it serviceble.(Note : cost forreplacement of minor spares i.e.rubber \"O\" ring , oil seal, upper bush, motor bush and thrust bearing etc. is deemed to be included in the item rate). |
| 4 | Lowering down of borewell submersible pump of any type and capacity upto 12.5 HPalongwith UPVC column pipe and 3 core flat cable complete including (rethreading to GI pipe if required) and reconnecting of all electric and water line connectionforany make of pump & motor up to 200mtr complete all as specified and directed.Note: Column pipe and Submersible cable measured and paid seperately. |
| 5 | Supply and fixing 50mm dia (OD: 60 mm (2”) DN: 50 mm) ISI markedsuper heavy type and shall not be less than 30Kg/Cm2 hydrostatic pressure rating , threaded UPVC column pipe (each length shall not be less tha 3 meter for borewells alongwith PVC coupler with SS wire lock , shal be provided Multi seal ring, sealant and gripping system provides leak proof fitting and also capable to absorb the vibrations of the pump complete all as specified and directed. |
| 6 | Refixing old retrived of good condition steel tubing of 50 mm dia and connections in new or old position including cleaning internally and externally any grade/make in trenches/wall/floor/ceiling with and including providing all type of new fittings sockets, tee, union, elbow etc complete allas specified and directed. |
| 7 | S&F of GI tubing, medium grade, ISI Markedin any length including cutting, threading, making connection in new or old position with and including and all type of GI new fittings for laid in trenches/wall/floor pipe galvanized, “Medium class”, including fittings 50 mm (2”) diainlcuding taking down existing steel tubing and connections with fittings and Scada valves/NRVs/Gate valves/butterfly valves etc complete all as specified and directed. |
| 8 | S&F new flange type non return valve of size 50 mm dia including nuts, bolts and all connecting accessoriescomplete all as specified and directed. |
| 9 | Supply and fix Strainer Y type,flanged End Flanges ISI marked as per undrilled Working Pressure: 16kg/cm²g Hyd. Cast Iron Body Y Type Strainer Size: 50mm (2 inch) complete all as specified and directed. |
| 10 | S&F of cast iron body class B woltman type analog water flow meter, flanged type as per IS-237350mm dia rubber gasket for flanged joints including necessary bolts and nuts of suitable size including flange for GI pipes both side of meter etc, threading and testing complete all as specified and directed. |
| 11 | S&F gun metal globe or gate valves of 50mm dia, confirming to IS: 778 with iron wheel head, screwed both ends for iron pipe and fixed in existing or new position complete all as specified and directed. |
| 12 | M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized iron strip 32X6mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 part – I connected to machinery/equipment for Timer Panel etc. as required 32x6 mm dia galvanized iron with 40mm GI light Grade pipe for protection including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thick in PCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and 20mm bore GI watering pipe medium grade,etc. complete all as specified and directed. |
| 13 | Supply and fixing in repair, flexible flat XLPEinsulated PVC sheathed copper couductor stranded submersible cable1100 volt grade 10 Sqmm 3 core ISI marked including jointing material and connection work complete all as specified and directed. |
| 14 | Supply and fixing in repair, flexible flat XLPEinsulated PVC sheathed copper couductor stranded submersible cable1100 volt grade 6 Sqmm 3 core ISI marked including jointing material and connection work complete all as specified and directed. |
| 15 | Supply and fixing in repair, flexible flat XLPEinsulated PVC sheathed copper couductor stranded submersible cable1100 volt grade 4 Sqmm 3 core ISI marked including jointing material and connection work complete all as specified and directed. |
| 16 | S&F round Nylon rope dia 10mm and connected clamp nut bolts fixed , complete all as specified and as directed. |
| 17 | Supply & Fix Star Delta Motor Control Panel made of 3.15mm thick CRCA Sheet single door Outdoor type with epoxy powder coating of RAL-7035 (Siemens Grey) shade with matt finish and factory assembled, conforming to degree of protection IP-54, front side single door type with locking arrangement and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber. The panel shall be provided with aluminium bus bars, electrolytic grade of adequate rating or specified below.The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding.The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars. Note: Earthwork and PCC work shall be measured and paid separately\"All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers.The panel shall be provided 4 Nos 25x25x5mm thick angle iron supports of not less than each 0.6 mt height duly painted with anti-corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement. The overall size of the panel shall not be less than 900mmX300mmX900mm (L x B x H).Including dismantling of existing old one complete along with its all cable connection and relaying and reconnecting the LT power cable etc. |
| 18 | The panel shall be provided with and including following accessories:-Smart Controller MU-G6S SMART Controller withxD1000 415V Drive 5.50kW(ND) suitable up to 6 HP, In-built short circuit protection and Theft protection, gives emergency alert to your mobile when someone steals your pump, cable or controller , With Dry Run, Locked Rotor and Short Circuit protection (In-built MCB with K-Curve & MCCB) , Voltage and current based protection for all faults with individual protection Enable/Disable feature , In-built hour based and Real Time Clock based timers with time compensation feature , With Line Voltage, Phase Current, Power Factor, Power, Energy metering and total run time information for your pump,Complete operation (Remote ON/OFF, parameter setting, monitoring and troubleshooting) through SMS or App or IVRSAvailable in Hindi, Gujarati, Marathi, Tamil, Telugu, Kannada, Malayalam, Bengali, Oriya, Punjabi and English languages with different language selection for individual users , Microcontroller based technology › Easy installation with factory fitted complete wiring and terminal block, need to connect only the supply and motor wires. The quoted cost shall include the cost of communication for a period of 36 months from the date of completion i.e. recharge of SIM and cost of installation of SIM in each controller also.Make-L&T/C&S/Havells (Make of smart controller and VFD shall be same make)Note:-(a) M-Power++ is compatible with LTE 4G/VoLTE. It also supports 2G network.(b) Enables Remote operation (Pump ON/OFF) through GSM networks.(c) It can operate through missed Call/IVRS/SMS. Regional languages are available for SMS/IVRS(d) All Event are communicated to user by SMS& Total Pump run time can be checked.(e) Wide range of selection for operating modes are available like Auto/Manual/Timer (Duration Based)/ 4 Daily Timers (RTC Based)(f) Compatible with 1 Phase and 3 Phase starters and controllers. |
| 19 | All as per item no 17 above but with VFD xD1000 415V Drive 7.50kW(ND) suitable for above 6 HP to 10 HP complete all as specified and directed. |
| 20 | All as per item no 17 above but xD1000 415V Drive 11.0kW(ND) suitable above 10 HP and upto 15 HP complete all as specified and directed. |
| 21 | Developing of tube well by means of air compressor and using three way valves/necessary T&Petc , for number of hours, until sand free clear potable water is obtained complete all as specified and as directed.Note : Quoted rate is inclusive of all required T&P |
| 22 | Enhancing recharge and revival of failed/Dry/low yeild/any borewell using Hydrological survey by trained hydrogeological expert and making details as per Appx 21A, using a Borewell underwater scanning camera system, undertakes a thorough hydrogeological investigation and lithological mapping, provides information such as casing depth, any hinderances, depth of water bearing structures, thickness of aquifer structures, any deformities, caving ins, etc and making precise perforations to the impervious borewell casing from inside at an appropriate depth. This testing shall be carried out through Patented Technology including providing inventory details with Logsheet, Water Quality Tests – pH, EC, TDS, etc., copy of Video of the Borewell Scanning Camera to visually map Litholog (Angiograph of Borewell) complete all as specified and directed.Note:- (i) MoU shall be submitted from patented firm and submitted before carrying out this job.(ii) Taking out & Lowering down of the the borewell pump shall be paid and measured seperately. |
| 23 | Yield test for the bore wells as per IS 2800 by continuously pumping upto 16 hours or as per actual hours to determine safe pumping yield including making details as per Appx 22A, making all arrangements for test and necessary T&P/tools etc and Water Quality Tests as per IS-10500– pH, EC, TDS etc complete all as specified and directed.Note:-(i) Taking out & Lowering down of the the borewell pump shall be paid and measured seperately. |
| 24 | Supply and fixing illuminated display board of size shall not less than .9M x .3M x .9M (L x B xH)with Flex of Light Blue( MES Colour) Colour of letters shall be white,outerside fabrication bordered with Aluminium angle Frame of size 35mm x 35mm x 4mm thick, inner side fabricated with 12mm MS square barincluding all internal wirings and illuminated with 2 feet LED 20 W Tubelightfitting 02 Nos, SMC/FRP Junction Box 140mm x 140mm x 95mm inner dimension make sintex cat part No GSJB-1414 and written \"BOREWELL, AGE E/M Bairagarh, GE Bhopal\",size of letters shall be proportion with overall size of board with electrical connection complete in all respect and electrical connection with PVC insulated 3 core cable not less than 4 Running meter complete all as specifiedand as directed. Note : Before manufacturing boards drawing and design of Board including colour of board shall be approved by Engr-in-charge. |
| 25 | M& L for PCC demolition of panel of any type any description and in any postion complete all as specified and directed. |
| 26 | M&Lfor plain concrete cement 1:3:6 type C2 using 40mm graded coarse aggregate for foundation of poles including necessary form work and PCC Demoltion of Strut/pole of any description and in any position complete all as specified and directed. |
| 27 | M & L gravels for packing in tubewells as per IS-4097free from impurities such as shale, mica, felspar, clay, sand, dirt, loam, haematite and organic materials aggregate for evenly spreading around borewell casing pipes upto the required thickness from natural ground level complete all as directed by Engineer in Charge |