| 1 | Dismantling ofPVC water storage tank exc 250 and not exc 500 ltrs capacity and removing to store complete all as specified and directed. |
| 2 | Demolition of reinforced cement concrete (reinforcement cutas required to facilitate demolition) as in rcc water tanks, Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed. |
| 3 | S&F rotational moulded,multilayer HDPE water storage tank (white colour three layer) of 500 ltrs capacity (Cylindrical vertical with closed top)ISI marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia PTMTfloat valve epoxy coated Aluminium rod with high density plastic float ball( of minium weight 210 gms ) and refixing of inlet, outlet & overflow pipe etc, complete all as specified and as directed. |
| 4 | S&F in repairs Gun-metal,globe or gate valves with iron wheel head,screwed both ends for iron pipes for 20mm bore of pipe complete all as specified and directed. |
| 5 | Dismantling of brick tiles or terracing tiles single layer on roof & disposal of retrived material upto a distance n.exc 100m complete all as specified and directed |
| 6 | Demolition of mud in roof, any thickness including plastering and leaping ( where full thickness recoved or only a part there of disposal off rubbish upto a distance n.exc 100m, complete all as specified and directed |
| 7 | Removing of surplus excavated/demolised materials to a distance exc 250m and n exc 500 m away where complete all as specified and directed.Note: Demolished material should not be thrown away on the ground from the top of roof, it should be removed from the roof manually or by any mechanical means. |
| 8 | M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed. |
| 9 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof curbing, padding over roof slab complete all as specified and directed. Note - Average thickness shall not exceed 40mm complete all as specified and directed |
| 10 | M&L for rendering 10 mm thick on concrete surface when concrete is green on roof surface in cement mortar 1:3 mixed with water proofing compound @ 200 ml per bag of cement or as per manufacturer\"s instructions complete all as specified and directed. (Note : WPC shall be measured & paid separately) |
| 11 | M&L for water proofing treatment on roof slab consisting with following operations:-(i) Existing surface shall be cleaned of all dust, fungus, moss and other foreign material etc by using wire brush & dusting.(ii) Apply a layer of bituminous primer conforming to IS 3384 @ 0.4 liter/ sqm on plaster surface.(iii) After primer the entire roof surface shall be applied with hot blown bitumen grade 85/25 conforming to IS 702 @ 1.2 Kg/sqm.(iv) Over hot bitumen, polymeric water proofing membrane minimum 3mm thickness consisting of 90 to 100 micron thick central core of HMHDPE film and standard weight 3 Kg/Sqm applied with hot blown bitumen of 85/25 grade Conforming to IS-702 @ 1.20 kg/sqm shall be laid with 100mm side lap/end lap on prepared surfaces as per manufacture\"s Instruction and strict supervision of manufacture\"s technical representative. Note- The laying of the membrane shall be done through authorized applicator of the manufacturer. |
| 12 | M&L for ceramic cool rooftiles, 10mm thick (Square/ rectangular) area of each tile n. exc 0.11sqm as in floor over roof slab etc set and jointed in neat cement slurry and pointed in white or coloured cementincluding 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 13 | S&F for 25mm thick Preformed joint filler for crumple joint etc conforming to 1838-1961 and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed. |
| 14 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for incl cutting of reinforecment and removing rubbish off the premises complete all as specified and directed. |
| 15 | M&L for providing precast cement concrete 1:2:4 type B1 in window or door cills, lintels, bressumers, steps,quoin blocks (for use with masonry), stringcourses, copings.kneelers, apex stones, pier caps, columns, posts,boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin) corbels, brackets, etc. (of any section indicated), with plain fair faces,including chamfers, weatherings, throating etc. and setting in mortar 1:4 complete with joints to match complete all as specified and directed. |
| 16 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape, required, including cranking, bending sprially for hoping for cols, hooking ends and binding with MS and including wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 17 | Demolition of cement concrete of any description and in any position complete all as specified and directed. |
| 18 | M&L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate, cills, steps; copings seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,rounded or chamfered on edges complete all as specified and directed. |
| 19 | Demolition of brick work built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings etc complete all as specified and directed. |
| 20 | M&L for brick work with sub class \"B\" bricks,straight or curved on plan exc 6m mean radiusbuiltin cm 1:6complete all as specified and directed. |
| 21 | Taking down cement or cement lime plaster any description fromwalls/ceiling etc including racking out joints, hacking for key & scrubbing down with water including removing of debries out side of MOD landcomplete all as specified and directed. |
| 22 | M&L for rendering 15 mm thick in cement mortar (1:4) on other than fair faces of brick work or concrete surface mixed with water proofing compound @ 200 ml per bag of cement or as per manufacturer\"s instructions, finished even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured & paid separately) |
| 23 | Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work n exc 15 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc complete all as specified and directed |
| 24 | Supply only Liquid water proofing compound (ISI marked) complete all as specified and directed |
| 25 | Taking down plaster from edges of Roof projection/chhajja or corners of columns where steel reinforcement coming out, fixing 15 mm size Wire netting of mild steel wire 1.60mm dia fixed with tinned tacks of wire staples and filling with 15mm thick rendering in CM (1:3 ) complete all as specified and as directed. |
| 26 | M&L forpreparation of newly plastered surfaces of wall and applying two coats of Cement Base Paintwhite or tinted of approved shade over a coat of alkali resistant primer complete all as specified and directed. |
| 27 | Taking up or down 20mm bore pipes steel tubing and connections including cleaning for refixing or removing to store or removing from site complete all as specified and directed. |
| 28 | S&F 20mm bore Steel water tubing \"medium grade\", galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 29 | Refixing old steel tubing and connection in new or old position in wall/ceiling/floor etc bore of pipe 20mm dia complete all as specified and directed. |
| 30 | M&L for preparation of old decorated surfaces of wall and applying one coat of Cement Base Paint complete all as specified and directed. |
| 31 | M&L for preparation of old decorated surfaces of ceiling/chhajja and applying one coat of white wash complete all as specified and directed |
| 32 | Excavation in post holes (or similar holes) each not exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken mixed with earth around, in layers not exceeding 25 CM complete all as specified and directed |
| 33 | M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed |
| 34 | M&L for Mild Steel rolled sections confirming to Fe-290 (gd E-165) as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc complete all as specified and directed |
| 35 | M&L for preparing new or previously untreated steel and iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed |
| 36 | M&L for pre painted galvanised aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 37 | M&L for pre painted galvanised aluminium zinc coating GI based corrugated steel plain sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 38 | M&L for Machine pressed precast concrete interlocking paver block coloured any shape and size confirming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement and pigment including 25mm thick sand cushion complete all as specified and directed |
| 39 | M&L for rubber moulded chequered cement concrete tiles 300mm x 300mm x (20 to 25) mm thick with grey cement and pigment set jointed and pointed in neat cement slurry over screed bed or bedding layer 15mm thick in CN (1:6) in floor complete all as specified and directed |
| 40 | M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed |
| 41 | M&L for providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings, bed plates including weathering, slightly rounded chamfered angles and throating including necessary form work complete all as specified and directed |
| 42 | M&L for framed work such as grills, gratings, gates etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work confirming to Fe-290, Gde E-165 complete all as specified and directed |
| 43 | S&F glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts in roof, wall etc complete all as specified and directed |
| 44 | M&L for Ornamental and intricate design framed work of mild steel confirming to Fe-290 (Gde E-165) as in doors or gates including cutting, bending in required shape and design, welding etc framed and hung including pintle hinges, stops and hand made sliding bolts etc complete all as specified and directed |
| 45 | M&L for 16-18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including cement mortar bedding (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed |
| 46 | M&L for rendering 15mm thick in CM 1:6 on other fair faces of brick work or concrete surface of wall and finished surface even and smooth without using extra cement complete all as specified and directed |
| 47 | M&L for preparing of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed |
| 48 | M&L for preparing of newly plastered surfaces of wall and applying two coats of cement based paint complete all as specified and directed |
| 49 | Schedule of Credit (MINUS) Rs. 64,550.00 B/F from Serial Page No.[Note : Detailsof items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum |