| 1 | Demolition of reinforced cement concrete in ground floors and pavings n. exc. 15cm thickness (below or above ground level) and removing rubbish to outside MD land complete all as specified and directed. |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided for wall complete all as specified and directed. |
| 3 | Dismantling plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern roof covering complete all as directed. |
| 4 | Surface excavation n exc 30 cm deep & avg 15 cm and getting out in hard / dense soil complete all as directed. |
| 5 | Excavating over areas n exc 1.5m in depthin hard / dense soil and getting out complete all as specified and directed. |
| 6 | M & L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 7 | S&F TMT bars 10mmdia and over, cut tolength, bent to shaperequired, includingcranking, bendingspirallyfor hoopingfor columns, hookingends and bindingwith and includingmild steel wire(annealed) not lessthan 0.9mm dia orsecuring with clips complete all as specified and directed. |
| 8 | S&F TMT bars 5 mm to 10mmdia as in stirrups / spacers / binders, cut tolength, bent to shaperequired, includingcranking, bendingspirallyfor hoopingfor columns, hookingends and bindingwith and includingmild steel wire(annealed) not lessthan 0.9mm dia orsecuring with clips complete all as specified and directed. |
| 9 | M&L forRCC M-30 (Design Mix) (20mm graded aggregates) as in foundation, footing, mass concrete, foundation beam, plinth beam and base for column complete all as specified and directed. |
| 10 | M&L for RCC M-30 (Design Mix) (20mm graded aggregates) as inColumns,pillars, piers,posts and struts complete all as specified and directed. |
| 11 | M&L for RCC M-30 (Design Mix) (20mm graded aggregates) as in beams, cantilevers,bressummers, lintels over 1.5m span complete all as specified and directed. |
| 12 | M&L for RCC M-30 (Design Mix) (20mm graded aggregates) as in slab supported on wall ,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 13 | Use & waste for flat formwork to sides of concrete foundations, footings, bases of columns raft and raft beams, sides and soffits if any of foundations and plinth beams and similar work, etc, rough finished surfaces of concrete etc all as specified and directed |
| 14 | Use & waste for flatform work to sides of pillars, posts struts, piers columns and stanchions, square, rectangular or polygonal rough finished surfaces of concrete etc all as specified and directed |
| 15 | Use & waste for flat formwork to sides of concrete beams, cantilevers,bressummers, lintels over 1.5m span and similar work, etc, rough finished surfaces of concrete etc all as specified and directed |
| 16 | Use & waste for flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat surface, rough finished surfaces of concrete etc complete all as specified and directed |
| 17 | Returning, filling in incl spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified & directed. |
| 18 | Removing excavated material to a distance n exc 50 mtr and depositing where directed at a level n exc 1.50 mtr above the starting point complete all as specified & directed. |
| 19 | M & L for full or more brick thick Brick work with AAC bricks of size 600 x 200 x 200mm / , 600 x 200 x 230mm straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 using old size brick complete all as specified and directed. |
| 20 | M & L for rendering 15 mm thick cement plastering on wall surfaces in two layers (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4,mixed with liquid water proofing compoundin top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 21 | Supply onlyliquid water proofing compound complete all as specified and directed. |
| 22 | S & F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework ofwater tanksand similar work, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under \"Structural Steel\")complete all as specified and as directed. |
| 23 | M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. |
| 24 | Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumifion based fluoropolymer resin coating of approved colour and shade on one faceand polymer (Service) coating on other face as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. The fastening brackets of Aluminium alloy 6005 T5/MS with hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristicscomplete all as specified and directed. (Note: (i) Actual area on the external face of the curtain wall with aluminium composite panel cladding shall be measured for payment purpose) |
| 25 | M&L 18 to 20 mm thick granite stone slabs (colour/ shade, design / pattern as approved by GE) tiles machine cut in skirting/dado/cladding jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing and including screed bed 10 mm thick in cement mortar 1:3, complete all as specified and as directed. |
| 26 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. |
| 27 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 28 | M&L for drilling holes ,dia and depth of hole shall exc. 25mm but n.exc. 40 mm tappered(with standard or gasthread) complete all as specified and directed. |
| 29 | M & L for 75 mm thickPCC 1:4:8, type D2, (using 40mm graded stone aggregate) as in sub- base floor finished the surface fair and rough to receive subsequent layer with and including necessary formwork complete all as specified and as directed. |
| 30 | M & L Machine pressed precast concrete interlocking paver block any shape prepared with grey cement and pigment of size confirming to IS 15658-2006 of 80 mm thick M-40 Grade laid over sand cushioning layer complete all specified and directed. (Note: Sand cushioning shall be measured and paid in relevant item.) |
| 31 | M&L for sand filling under floors or in foundations including watering and consolidation for cushioning complete all as specified and as directed. |
| 32 | Supply, laying and testing of XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.00 sq mm 4 core shall be laid under trench or pipe or loop or shall be fixed on wall / pole including taking out old unserviceable cable complete all as specified and directed.(Note: Earthwork , excavation, sand coushioning, GI pipe etc. shall be measured and paid separately uinder relevant item) |
| 33 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, in cable tench etc. n exc 10 sqm on plan and getting out soft / loose soil complete all as directed. |
| 34 | M & L for sand cushioning under trenches as in cable protection complete all as specified and directe.(Note: Punned thickness shall measured for payment purpose) |
| 35 | M&L for Sub Class B bricks common burnt clay building bricks designation 75 Kg/Sqmmcomplete all as directed. |
| 36 | Supply and laying 40 MM bore diaGI tubes, light grade galvanised with all fittings laid in trenches etc for protection of cable including taking up / down old unserviceable pipe complete all as specified and directed. |
| 37 | S&F MCB 6-32 Amps, TPN, 415 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed. |
| 38 | S&F MCB 6 to 32 Amps, SPN, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed. |
| 39 | S&F MCB 6 to 32 Amps, SP, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed. |
| 40 | S&F double door metallic sheet metal enclosure for DBs when MCB to be used,SPN, 8 ways 240 Volts (horizontal type)fixed properly on in concealed position and to provide required size of flexible conduit at any open surface near DBs for cable / wires complete all as specified and as directed. |
| 41 | S&F single door metallic sheet metal enclosure for DBs when MCB to be used,SPN, 2 ways 240 Volts (horizontal type)fixed properly on in concealed position and to provide required size of flexible conduit at any open surface near DBs for cable / wires complete all as specified and as directed. |
| 42 | M&L for sub main wiring with 2 run of Single core FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.50 Sqmm alongwith one run of single core FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.50 Sqmm as earth continuity conductor drawn through and including one run of PVC conduit of suitable size, concealed on wall or ceiling including taking down old unserviceable submain wiring complete all as specified and directed.NOTE : (i) Three runs of single core 2.50 Sqmm cable & one run of PVC conduit shall be measured as one unit.(ii) Cost of cutting chases for concealed wiring shall be deemed to be included in the quoted rates. No claim in this regards shall be entertained at a later stage. |
| 43 | M&L for sub main wiring with 2 run of Single core FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 1.50 Sqmm alongwith one run of single core FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 1.50 Sqmm as earth continuity conductor drawn through and including one run of PVC conduit of suitable size, concealed on wall or ceiling including taking down old unserviceable submain wiring complete all as specified and directed.NOTE : (i) Three runs of single core 1.50 Sqmm cable & one run of PVC conduit shall be measured as one unit.(ii) Cost of cutting chases for concealed wiring shall be deemed to be included in the quoted rates. No claim in this regards shall be entertained at a later stage. |
| 44 | S&F 30W round recessed COB down light, with neutral white light (4000K), with cut out size not less than 130mm dia, minimum lumen efficiency of 70 lm/W, housing made of PDC aluminium with all accessories complete connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 45 | M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia bymeans of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (medium grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (light grade) testing on completion complete all as specified and directed. [Note : (a)Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate.] |