| 1 | Surface dressing n exc 15 cm deep and getting out In hard/dense soil complete all as specified and as directed. |
| 2 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing outside MD land complete all as specified and directed. |
| 3 | Excavation over areas not exceeding 1.5m deep and getting out in hard/dense soil. |
| 4 | Excavation over areas exceeding 1.50m deep and not exc 3.00m deep and getting out in soft disintegrated rock |
| 5 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting outin hard/dense soil complete all as specified and as directed. |
| 6 | Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundations,fillingand mass concrete. |
| 7 | M&L Providing, cement concrete 1:2:4 type B1 in lintels upto 1.5m clear span, cills, steps; copings, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including neccessary formwork. |
| 8 | M&L for modular size brickwork with fly ash bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 |
| 9 | Rendering 15mm thick in cement mortar 1:4 on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement, all as specified. |
| 10 | M&L for Reinforced cement concrete (Design mix) M30 (20 mm graded aggregate) as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including demolition of old RCC structure of any description and in any position all as specified and directed |
| 11 | M&L precast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slab set in CM 1:6 all as specified (Reinforcement steel will be measured and paid separately under relevant item. |
| 12 | M&L TMT reinforcement bars 10mm and over usingcut to length bent to shape as required including cranking bending spirally for hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia or securig with clips etc complete. |
| 13 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat and rough finished surface |
| 14 | Formwork to edges of concrete flats, floors and roofs etc n,exc 20cm wide for fair finished surfaces. |
| 15 | Supply only half burnt broken bricks size 50 to 100mm graded for loose filling etc complete all as specified and as directed. |
| 16 | Supply only broken stone aggregate, broken to gauge n exc 50 mm for loose filling etc complete all as specified and as directed. |
| 17 | Supply only broken stone aggregate, broken to gauge n exc 12.5mm for loose filling etc complete all as specified and as directed. |
| 18 | Supply only course river sand for loose filling etc complete all as specified and as directed. |
| 19 | PVC 150mm dia perforated caps screwed to ends of puff or vent pipes |
| 20 | S&F 150mm dia(Internal dia) PVC perforated pipe and single socketed in any length with rubber ring joint laid in borehole complete all as specified and directed. |
| 21 | M&L for cement Concrete 1:3:6 type C2 bed to 150mm pipe drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in, all as specified. |
| 22 | Supply and fixing HDPE pipe PN 10, 150mm bore with fixture fittings, bends complete all as specified and directed . |
| 23 | S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls and including clamps and all as specififed and directed |
| 24 | S & F 110mm bore PVC (SWR) bends of any radius all as specified and as directed |
| 25 | S & F PVC (SWR)junction single(single T)equal or unequal with access door bore of pipe 110 mm bore all as specified and as directed |
| 26 | S&F framed work such as grills,gratings, pit covering etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 all as specified and as directed |
| 27 | S&F 1.25 mm thick plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) all as specified and as directed |
| 28 | M & L preparation of new steel surface over 10Sqm cm width or girth of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. |
| 29 | M & L for Trial bore of 250 mm dia below ground level in any kind of soil strata including hard stone/boulder including electric logging, MS cap, MS flat iron clamps, reducing socket etc. |
| 30 | Supply and lowering ERW fine cut MS slotted strainer 150 mm internal dia, 6.0 mm thick with 1.5 mm x 10 cm slots including Jhonson well screens of LCG with slot opening 0.75 mm including sockets etc complete. |
| 31 | M&L for 40mm thick PCC, 1:2:4,type B-1 (using 20mm graded crushed stone aggregate), as in floor finishing surfaces of conc topping even and smooth with using extra cement . |
| 32 | Returning filling of excavated any type soil including spreading leveling watering and well ramming in layers n exc 25 cm thick all as specifiedcomplete all as specified and as directed. |
| 33 | Removal of excavated materialexc 0.5km but not exc 1.5km outside MD land |
| 34 | Extra for forming fair finished drain or channel 40 to 50 cm inner girth in cement concrete using extra cement including forms, moulds mitred / stopped ends etc |