| 1 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mmFRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 2 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mmFRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 4 | a)4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 5 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board,415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 6 | a)6 way (4 + 18), Double door |
| 7 | a)8 way (4 + 24), Double door |
| 8 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 9 | a)100 A |
| 10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 11 | a) Single pole |
| 12 | b)Triple pole and neutral |
| 13 | Supplying of PVC insulated and PVC sheathed aluminium conductorarmoured XLPE power cable of 1.1KV grade of following sizes etc as required.Make; Havells or equivalent in Polycab/Finolex/RR cables /Anchor |
| 14 | a) 3.5 Core x 95 Sqmm |
| 15 | Supplying and laying offollowing sizeDWC HDPE PIPE along with all accessories like socket, couplers etc confirming to IS: 14930 PART- II Complete with necessary HDPE fittigs for protection of 1.1 KV grade on surface etc as required. |
| 16 | a) 77/63 mm dia (OD-77 mm & ID-63 mm nominal) |
| 17 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 18 | a)Above 35 sq. mm and upto 95 sq. mm |
| 19 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 20 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 21 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. |
| 22 | a)3½ X 95 sq. mm (45mm) |
| 23 | Supplying, installation, testing and commissioningof35KAbreakingcapacity ofFixedthermal & fixed magnetic settingMCCB, 200A four poleMake:- Havells Cat.No.IHLFN40200 with four pole MCCBs enclosure Make:- Havells Cat.No. \"F\" Frame FP IHEFFP respectively or equivalent in Legrand/L&T/ any reputed make complete with all accessories etc as required. |