| 1 | Earthwork |
| 2 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil |
| 3 | Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding1.5min width or 10sqm on plan),including dressing of sides and ramming of bottoms, lift upto1.5m,including getting outthe excavated soil and disposal of surplus excavated soil as directed, within a lead of 50. All kinds of soil |
| 4 | Concrete work |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – all works up to plinth level. 1:4:8 (1 Cement: 4 coarse sand (Zone-III): 8 graded stone aggregate 40mm nominal size) |
| 6 | Reinforced Cement Concrete work |
| 7 | Centering and shuttering including strutting, propping, etc. and removal of form for all heights. Foundations, footings, bases of columns, etc. for mass concrete |
| 8 | 1:1.5:3 (1 cement:1.5 coarse sand (zone-III); 3 graded stone aggregate 20mm nominal size) |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 10 | PP tiling |
| 11 | Supply, installation, testing and commissioning of modular PP interlocking sports flooring tiles for Basket Ball court, complete as per specifications below.Material - Tiles manufactured from 100% high-quality virgin polypropylene (PP).UV-stabilized, weather-resistant, anti-fungal and moisture-proof. UV-stabilized, weather-resistant, anti-fungal and moisture-proof. Tiles manufactured from 100% high-quality virgin polypropylene (PP).UV-stabilized, weather-resistant, anti-fungal and moisture-proof. Suitable for outdoor sports usage.Tile Dimensions - 304 mm × 304 mm × 15.8 mm (±0.3 mm tolerance). Thickness strictly not less than 15.6 to 15.8 mm at any point. Installation System - Interlocking click-lock system (no adhesive, no nails). No gaps, No loose movement, Uniform alignment across courtSurface Performance - Anti-skid textured playing surface. Uniform ball bounce and player grip. Uniform alignment across court |
| 12 | Providing and fixing of basket ball post accessories(1 pair- 2 nos)each no consisting of : 1.Acrulic fiber board= size of 1.80mx1.05 m of 30 mm thickness2.Board Supporting frame =L angle size of 20mmx30mmx3 mm thickness3.MS Ring= 0.45 m dia and thickness of ring is 20 mm4.Acrulic board fixed with Ms Plate size of 200mmx200 mm x3 thick with the supporting 04 nos of Anchor bolts |
| 13 | Fencing |
| 14 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4mm |
| 15 | SPainting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade : Two or more coats on new work |
| 16 | Neat cement punning |
| 17 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. |
| 18 | Steel work |
| 19 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 20 | Electrical Works |
| 21 | Supply and transportation and erection of swaged pole of size 9.0mts (113kg) working load per is 2713/1980(410 s-p27) specification the length of sections should be 5.0m at bottom 2.0mts at middle and 2.0 at top and outer dia thickness of section 139.7mm x 4.50mm at bottom and 114.30x3.65mm at top duly erected on bridge kerb portion (R.C.C Work with V.C.C M15 Concrete as per the direction & recommendation size of the P.U Engineer with 4nos 25x 6mm MS special clamps bolts with nuts and locking nuts with one coat of Red oxide paint & two coats of aluminum paints with coil earthling etc including cost and convince of all material and all labour charges etc complete (steel tubular) |
| 22 | Supply, Installation, Testing and Commisioning of 300Watt Led Flood Light delivering minimum system lumen of 36000 lm & the luminaire shall be with system efficacy ≥ 120 lm/W, aluminium die cast housing powder coated with PC lens for better light output and light distribution. The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be BIS Registered with electronic driver with input voltage range of 140-280V, IP 66, IK07, 50000 Hrs LED life with L70B0 Criteria. The LED driver shall be easily available in India for repair and service. The LED shall be SMD type. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacturer along with Photo Biological Safety Standard. 5KV internal surge and 10KV external protection in both Common Mode and Differential Mode. Dimension: 310 X 390 X 73mm (±2mm), Weight: 8Kg. The cost includes cost for suitable mounting bracket over wall. |
| 23 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35sqmm |
| 24 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 4x16 sq mm (28mm) |
| 25 | 4x25 sq mm (28mm) |
| 26 | Supply and fixing of following XPLE armourned 1.1KV grade conforming to I.S. 7098/ 1554Aluminium Conductor Cables: Supply of following sizes of PVC sheathed PVC/ XLPE insulated Aluminium conductor armoured cable of 1.1 KV grade conforming to IS:7098 part-1/ IS:1554 part-1 respectively & ISI marked. 4 C x 16 Sqmm XLPE cable |
| 27 | 4C x 25 Sqmm XLPE cable |
| 28 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 29 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 30 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 31 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required:2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 32 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required:4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 33 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required:4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 34 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 35 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 36 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 37 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, Inter connections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator: 12 way (4 + 36), Double door |
| 38 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps |
| 39 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |