| 1 | Dismantling of existing Bird Poofing Net of any description including all associated Fittings and Accessories from Hangers of any height and removing the debris off the premises complete all as specified and as directed. |
| 2 | S & F Bird Proof Net of size 25 X 25 mm made of 2.5mm Dia Twine of Polyolefin Co-Polymer White / Green or approved colour, Heavy Duty, fixed to MS Frame Work without any sag with suitable fixing materials such as Clamps, Bolts, Nuts, Washers, Nylon Zip Ties at a height of 8.00 to 10.00 m from Floor Level inside Shed / Storage Accommodation / Hangers etc. including providing double scaffolding and safety measures as required and removal of the same on completion complete all as specified and as directed and comprising the following specifications:[a] Material of the Net: Polyolefin All Weather Proof Co-Polymer[b] Twine Breaking Strength: >22 KGF[c] Mesh Breaking Strength: >18 KGF[d] Knot Breaking Strength: >28 KGF[e] Size of Mesh 25mm X 25mm [± 2mm][f] Diameter of the Twine: 2.5 mm[g] Quality Control: Filaments shall be Twisted and Knotted, Pressure Stretched and Tightened.[h] Chemical Properties: The Net shall be Chemically Inert, Flame Retardant and Highly Resistant to Chemicals at varying temperatures and shall be Highly resistant to Acids and Alkaloids at all concentration.Note: Make shall be approved by the GE in writing after checking above parameters from Manufactures Test Certificate, Independent Testing and physical checking of the Samples of Net. All safety measures for the safety of workmen shall be ensured by the contractor. Nothing shall be paid extra on any account. |
| 3 | S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E-250, Quality-A as in Roof Trusses [framed], Trussed, Purlins, Crane Gantries, Rails and fastenings and heavy bracket framing [Beam, Tee, Angle, Channel or Flat Sections] including distance pieces, cleats etc. complete all as specified and as directed. |
| 4 | M & L for Two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed. |
| 5 | M & L for Two coats of Synthetic Enamel Paint on Old Steel Surfaces exceeding 10cm width or girth including preparation of surfaces complete all as specified and as directed. |
| 6 | M & L forPowder Coated Aluminium Sections [Minimum 50 Micron thick] of approved colour as in Door, Window, Ventilator Frames, Partitions with one or more rebates and Door, Window, Ventilator Shutters, Sliding or Openable Type, with or without Sash Bar, Aluminium section weighing not less than 0.55 KG / RM including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [1 No], Suitable Handle [1 No], Stainless Steel Friction Hinges [1 No] per Window Shutter and 150mm Dia Handles on both sides, Tower bolts, 200 mm Long [2 Nos] etc. complete all as specified and as directed. Note: [a] The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I.[b] Supply only panel inserts of Glass / Particleboard / Gauze / Grills will be measured and paid separately.[c] Unit rate quoted shall be deemed to include for cost of Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws fittings such as Handles, Butt Hinges, Tower Bolts, Stainless Steel Friction Hinges and fixing only of Panel Inserts ofGlass / Particleboard / Gauze / Grills / Aluminium Composite Panel etc. |
| 7 | S & F Double Action Floor Spring Hydraulically Regulated made of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governingpivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed. |
| 8 | Supply only 8mm thick Toughened Glass, Factory Made in squares of any size in each pane complete all as specified and as directed. |
| 9 | Supply only Aluminium Composite Panel sheet of 6 mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30 micron of approved Colour / Design complete all as specified and as directed. [Make of Aluminium Composite Panel: ALSTRONG / ALCOBOND / ALSTONE] |
| 10 | S & F False Ceiling Frame Work using Powder Coated [Minimum 50 Micron thick] Aluminium Snap Grid Frame work of 600 X 600 mm panel size for false ceiling with Aluminium \"T\" section of size 38 X 25 X 1.50 mm thick for Main Runners, 25 X 25 X 1.5 mm thick for Cross Runners and Angle of size 25 X 25 X 1.50 mm thick along the Walls suspended with and including 4 mm dia, Galvanized mild steel wire as in suspenders of ceiling members fixed in proper position including supplying and fixing 4mm thick Decorative Non Asbestos Fibre Cement Building Boards [E Board] for false ceiling, fixed to ceiling section with 25 mm dry wall screws at 230 mm centres and including applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer to Ceiling Boards complete all as specified and as directed. |
| 11 | M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified and as directed. |
| 12 | All as per Serial Item No. 11 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified. |
| 13 | All as per Serial Item No. 11 above but for One 3 pin Socket Outlet 5 Amps on the Same Board with other switches complete all as specified and as directed. |
| 14 | All as per Serial Item No. 11 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor. |
| 15 | S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed. |
| 16 | S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed. |
| 17 | S & F Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed. |
| 18 | S & F Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed. |
| 19 | S & F Square recessed mounted Flat Panel LED Ceiling Light suitable for fixing in 2\" X 2\" Grid False Ceiling of not less than 3600 Lumens output, 6500 K, with high transmitive diffuser for soft-light and glare free symmetrical illumination with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 Make: Model / Catalogue No. CCR-127-36-57-SL-NWH of Crompton Greaves or its Equivalent Model in Philips / Havells / Wipro / GE / Bajaj / Jaquar |
| 20 | M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit. |
| 21 | S & F MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed. |
| 22 | S & F MCB, DP, 40 to 63 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed. |
| 23 | S & F MCB, SP, 6 to 32 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed. |
| 24 | S & F Electronic wall mounted time delay Voltage stabilizer of 5 KVA Capacity, Automatic Operation, for input variation of 170 Volts to 270 Volts with stabilised voltage of 230 Volts with accuracy of ± 2.5% complete all as specified and as directed Make: V Guard / Servo / Kee Line |
| 25 | Supply, install, testing and commissioning of 5 Star rated Hi-Wall Split type Air Conditioner [Indoor & Outdoor Units] with Cordless Remote Control Unit and with in-built advanced Air Filters for better indoor air quality with latest Inverter technology, having Eco friendly Refrigerant Gas, Copper Condenser Coil, EER 4.5 or above of Capacity 1.5 TR, Summer Cool, Inverter Compressor, Automatic 2D Swing Copper Condenser, BLDC Motor, necessary copper pipe connections including cutting, bending, brazing, insulation on pipe etc, PVC Drain Pipe, electric connection between indoor and outdoor unit with suitable size PVC insulated, multi-stranded copper cable complete all as specified and as directed. Make: Blue Star / Hitachi / Daikin / Carrier / VoltasNote: The rate quoted by the contractor is deemed to include for Powder Coated Mild Steel Fixing Brackets for Outdoor and Indoor Units at any height and Copper tube of suitable size, Drain Pipe made of High Density Polyethylene Pipes [HDPE] of pressure rating 6 KGf / Sq.cm of 20mm dia as required and 3 Core, 4 Sq.mm, PVC Insulated and PVC sheathed, heavy duty cable, ISI marked with Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade as required for connecting indoor and outdoor units. |
| 26 | S & F SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 32 Amps, 240 Volts complete all as specified and as directed. |
| 27 | M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit. |