| 1 | Excavation in post holes (or similar holes) in any type of soil, each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus spoil to distance not exceeding 50 mtr and making good surface complete all as specified and directed by Engineer-in-Charge |
| 2 | M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates, 75mm thick in foundation filling and mass concreteall as specified and directed by Engineer-in-Charge. |
| 3 | S&F for fe 410-w (Gde-E-250) Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting platesall as specified and directed by Engineer-in-Charge. |
| 4 | M&L for Preparation of new or previously untreated steelsurfaces of any description, over 10 cm width or girth, not otherwise described, and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer,all as specified and directed by Engineer-in-Charge. |
| 5 | S & F Pre-painted galvalume aluminum Zinc coating GI based Corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asall as specified and directed by Engineer-in-Charge |
| 6 | M &L Brick work with sub class\"B\" bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4, complete, all as specified and as directed. |
| 7 | Rendering 15 mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth with out using extra cement all as specified. |
| 8 | S&F mild steel as in hand rail, balusters, noising to steps, post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, drilling, bolting or riveting etc, conforming to Fe-290 , Gde-E-165 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge. |
| 9 | Supply only 3.15 mm dia galvanised steel chain link fencing, 50X50 mm mesh, made up into mattrsses or cages, lapped, wiredall as specified and directed by Engineer-in-Charge |
| 10 | Fixing only chain link fencing including line wires any mesh, size and type to any to any type of standard, rail, straining bolts, etc. including provn of winding wireall as specified and directed by Engineer-in-Charge |
| 11 | M&L mild steel round bars 10 mm dia conforming to FE-410-W (Gde E-250) quality A or Fe-290 (Gde E-165) for use in chain link fencing as wind tieall as specified and directed by Engineer-in-Charge |
| 12 | Mild steel screw bolts(machine made) with hexagonal or square heads at one end screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 30 cm and dia of neack exc 12 mm but not exc 20 mm complete all as specified and as directed by Engineer-in-Charge. |
| 13 | M&L formachine pressed precast concrete interlocking paver block with gray cement and no pigment, any shape and size confirming to IS- 15658 -2006 of 60-80mm thickness, M-40 Gde,Over and including 20mm thick layer of sand completeall as specified and directed. |
| 14 | M&L for 100mm thick PCC (1:4:8) Ty D2 as in sub base over rammed earthall as specified and directed by Engineer-in-Charge. |
| 15 | Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in any type of hard/dense soil. |
| 16 | S & F for glazed Ceramic tiles 8 to 9 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm ( size 600 mm x 1200 mm), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchlaid over cement screed bed 15 mm thick (1: 4) complete all as specified and as directed. |
| 17 | All as per item no. 17 except on vertical surfaces as in skirting etc over 10mm thick backing coat in CM 1:4, set and jointed in white cement with pigment to match all as specified and directed. |
| 18 | M&Lfor sand filling under interlocking pavour block floor or in foundations including watering and consolidation |
| 19 | M&L for Cement concrete 1:4:8 typeD-2using 40mm graded stone agg as in foundations, filling and mass concrete |
| 20 | M&Lfor 75mm thick cement concretetype D-2 1:4:8 (40mm graded aggreate) filling and mass concrete |
| 21 | M&L Providing cement concrete in coping type B-1 ,1:2:4 using 12.5mm graded stone aggregate complete all as specified including necessary form work and finishing the exposed surface even and smoth with using extra cement complete all as specified. |
| 22 | S&F Endura colours paving tiles 30cm X 30cm double charged digital printed with gloss, polished matt finished jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in CM 1:6 all as specified and directed. |
| 23 | M&L aluminium alloy powder coated windows including aluminium coated frames, silding track frame bottom weighing not less than 1.015 kg/Rm ,sides and top not less than 0.826 kg/Rm double revated and 0.55 kg/Rm for window shutter with one fixed glazed shutter and two nos glazed/gauged shutter silding type with aluminium sectins as per series-A (15mm) 3 track of jindal section number for silding windows with framed shutter including aluminium allow powder coated snap type beads handles with locking arrngement spring action and glazingclips joint cleats rubber gaskets etc inclding provision of 5.5 mm thick tinted frosted glass of superior quality and stainless steel jail including all standard fittings complete all as specified and directed |
| 24 | S & F mild steel framed work such as grillsn gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders freamed balusters, walk ways, railings, framework of watertanks and similar work including aldrop and hinges holdfast etc conforming to Fe 290. Gde-E-165. |
| 25 | Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed. |
| 26 | Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etcup to 10m height complete all as specified and directed. |
| 27 | Taking down chowkats or frames n.exc. 1.5 Sqm (without taking off shutters from the frame). |
| 28 | Taking down chowkats or frames(without taking off shutters from the frame) area exc 1.5 Sqm but n.exc 4.0 Sqm each. |
| 29 | Anodised aluminium powder coated sliding windows, window shutters and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as locking system, suitable handle (1 no.)complete all as specified and as directed by Engineer-in- charge. |
| 30 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS :1868 with minimum anodiccoating of grade AC 15) of approved design/pattern, with approved stadandered section and fixed to existing window frame with CP brass/stainless steel screws @200mm c/c, incl cutting the grill to proper opening size for ficing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement and direction of Engineer-in-charge. |
| 31 | S&F solid PVC wall lining consisting of 5mm thick plain colour pvc wall lining 2mm thick plain colour PVC sheet dully fitted into the wallinclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing but single side prelaminated PVC sheet use instead of plain clour sheet |
| 32 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). → Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 33 | S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 65 x 125 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (max toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr incharge. Note: For WPC solid door/windows frames,minus 5mm tolerance in dimension i.e depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made. |
| 34 | S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge.complete all as specified and directed. |
| 35 | Supply and fixing 30mm thick FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of density 650 kg/cbm manufactured by an ISO-9001-2015 certified company. Door to be panelled with SS mosquito and XTN aluminium mesh for additional strength and safety purpose (confirming as per IS 4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. SS butt hinges size 100mmx25mmx2mm and 32mm long steel screws drilled suitable to pass through other hardwares should be fixed with 19x6mm size steel screws, etc. complete all as specified& directed.”Note: MTC and Screw Out Test will be provided by Contractor |
| 36 | S&F SS barrel tower bolt extruded section 200mm long and fixed with SS Screws (ISI Marked) |
| 37 | S&F SS barrel tower bolt extruded section 150mm long and fixed with SS Screws (ISI Marked) |
| 38 | S&F 300mm extruded section SS sliding door bolt with hasp and staple and fixing bolt and nut (ISI Marked) |
| 39 | S&F 100mm extruded SS handle fabricated type and fixed with SS Screws(ISI Marked) |
| 40 | S&F 150mm extruded SS handle fabricated type and fixed with SS Screws(ISI Marked) |
| 41 | S&F in repair door closer aluminium (extruded section) hydraulically regulated designation No. 03, universal type, suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 Kgs. |
| 42 | M&L for preparation of newly plastered surfaces of walls and providing and applying putty of 1.5 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)complete all as specified as directed by Engr-in-charge.. Note spray painting(SMART PERIODICAL) |
| 43 | M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing treatment by rubbing ,with mechanichalbrooming down, washing with water etc and providing and applying exterior grade putty of 1.5 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge. Note spray painting(SMART PERIODICAL) |
| 44 | M&L for preparation of old decorated surface (plastered or unplastered) of walls by complete removal of existing treatment by mechanical grinder and applying cement base wall care putty of 1 mm thickness over plastered surface to prepare the surface even and smooth to receive primer and applying one coat primer &two or more coats Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. |
| 45 | Demolition Bricks (laid flat or on edge) or brick tiles in floors, roof, channels, kerbs, aprons, etc. (each layer all as specified and directed. |
| 46 | Demolition Mud in roofs, any thickness, including plastering and lapping (whether full thicknessremoved or only a part thereof) all as specified and directed. |
| 47 | Removing soil excavated material exc. 1.5Km but n exc 5km and depositing where directed at above the starting pointall as specified and directed. |
| 48 | M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone aggregate) on roof paddingsurface finished even and smooth without using extra cement complete all as spd & directed. |
| 49 | M&L providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalent Repair Polymer including taking down existing roof treatment of any type including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, complete all as specified land as directed.Note: The application shall be executed on any type of surface and on horizontal/Vertical areas. |
| 50 | M&L providing and applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary [coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge.Notes: For itmes ser No 51 & 52 (1) The work shall be executed through authorised applicator of manufacturer only.(2) Authrised Applicator shall be approved by GE before starting of work.(3) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material.Engineer-in-Charge shall deface the original purchase vouchers.(4) Guarantee: The contractor shall furnish a written guarantee for the effectiveness of the water proofing treatment for a period of Ten (10) years in favour of the GE. A sum equivalent to 2.5% (Two point Five Percent) of the cost of water proofing treatment shall be retained by the Govt from the contractor\"s dues as security deposit. The contractor may, however, furnish a fixed deposit receipt in lieu from a Schedule bank pledged in favour of Garrison Engineer. |
| 51 | M&L two coats of synthetic enamel painting on wooden surfaces not otherwise described over 10cm width or girth over a coat of pink primer inclding prepration of newly untreates surfacescomplete all as specified and directed. |
| 52 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and chamfered edges complete and including provn of 20mmthick screed bed or bedding layer in CM 1:4 etc complete all as specified . |
| 53 | M & L for 18-20 mm thick Black Granite stone work (table rubbed and polished) over and including15mm thick Screed bed or bedding layer in CM 1:4,as in steps, jambs, pillars, window cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite,front and side of slab moulded and polishedincluding dismantling the existing stone slab with screed/ backing and removal of debries out side the MOD Land complete all as specified and as directed by the Engineer-in-Charge.Note- The cost of making hole for Gas pipe in cooking plateform is included in unit cost of item and nothing extra shall be paid on this account. |
| 54 | Construction of 100 users Septic tank to carry sewage and sludge water, complete all as specified and shown in Drg No. STD 1320 (C) Sheet 1/3 to 3/3of Chief Engineer Chandigarh Zone and directed.Note:-(a) Excavation and earth work shall be in any type of soil. (b) The cost of all above provisions and other provisions as shown in drawings shall be deemed to be included in quoted rates of this item and nothing extra shall beentertained on this account.AND connected the existing manhole |
| 55 | Construction ofSoakage well 1.80 m dia and 3.0 m effective depth complete all as specified and shown in Drg No. STD 1173 (C) Sheet 1R/2 of Chief Engineer Chandigarh Zone and as directed.NOTE:- (a) Excavation and earth work shall be in any type of soil. (b) foundation in PCC 1:3:6 type C2 using 40 mm graded stone aggregate.(c) Honey combing brick walls masonry as shown in drawing.(d) RCC work where ever shown in drawings shall be M-25 Design Mix, type B1 using 20 mm graded stone aggregate(e)The cost of all above provisions and other provisions as shown in drawings shall be deemed to be included in quoted rates of this item and nothing extra shall beentertained on this account.and connected to septic tank. |
| 56 | M&L for cement concrete 1:2:4 type B1(using20mm graded stone aggregate) as in blocks for hold fast, coping,including form work to concrete surfaces, complete allas specified. |
| 57 | S & F Expanded metal n exc 4 kg weight per square meter, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members all as specified and all as specified and directed by Engineer-in-Charge. |
| 58 | M&L forVitrified tile ultra charge, 9-10mm thick (square/ rectangular) polished, area of each tiles not exceeding .38sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in cement mortor 1:6 complete all as specified. |
| 59 | M&L for preparation of old/new decoreated/undecoreatedexternal wall applyingtwo coats of berger weather proofing exterior acrylic emulsion paintup to 8 storey bldg complete all asspecified and all as directed by Engr- in-charge. |
| 60 | M&L for rendering 10 mm thick in CM (1:6) on any faces of concrete or brick surfacesfinished even and smooth without using extra cement complete all as specified and directed. |
| 61 | M & L for two coat of distemper oil emulsion over a coat of primer and 2-3 mm thickJK Birla wall care puttyincluding preparation of new plastered surface of wall complete all as specified and directed. |
| 62 | M & L forframed work as in doors, sun shade or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-410W-Gde-250 quality A complete all as specified and directed. |
| 63 | Roughening of surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dusts etcand applying neat cement slurry over rough concrete surface with 3.00 kg of cement/sqm. |
| 64 | M&L for Ceramic tiles of light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement tomatch and including provn of 15mmthick screed bed or bedding layer in CM 1:4 etc complete all as specified . |
| 65 | M&L for Ceramic tiles of light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement tomatchlaid over and including provn of 10mmthick rendering of backing coat in CM 1:4 etc complete all as specified. |
| 66 | M&L aluminium alloy powder coated door including aluminium coated frames and channel of section (door frame single grove 101.6mm x44.45mm x 2.1, shutter top section 47.62mm x44.45mm x1.95mm thick shutter bottom vertical section 85mm x 44.45mm x 1.80mm thick, shutter middle section 83.5mm x 44.45mm x 1.80mm thick shutter glazing clips weighing not less than 0.0097kg/rm as directed and approved by GE and as per IS specification including provn of 5.5mm thick tinted glass/12mm thick prelaminated particle board as required including alu handle 150mm, tower bolt 150mm, floor spring heavy duty \"smart\", looking arrangment \"godrej\" rubber gasket and door stopper complete all as specified and directed. |
| 67 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc |
| 68 | Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed. |
| 69 | M&L point wiring complete with 1.5 Sqm single core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI) marked concealed in wall/fixed to roof, ceiling etc and incl provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, modular fabricated sunken terminal box made out ofminimum 1.2 mm thick sheet steel duly painted concealed in walls, with 3mm thick bakelite/PVC sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, all as specified and as directed. |
| 70 | All as per item No 72 here-in-before but one light /fan point controlled by one switch. |
| 71 | All as per item No 72 here-in-before but one 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. |
| 72 | All as per item No72 here-in-before but one 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board |
| 73 | All as per item No72 here-in-before but one bell pointpoint controlled by one bell switch. |
| 74 | M&Lpoint wiring with PVC unsheathed multi stranded copper conductorcable 4.00 sqmm FRLS 1100 Volts inPVC concealed conduitmedium grade ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 4 sqmm FRLS 1100 Volts copper conductor cableas earth continuityconnected to common earthfor one 15 A switch socket power point, all as specified |
| 75 | Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories(Concealed)/ Surface in walls all as specified and as directed. Note :- Two run of main wire PVC insulated FRLS 1100 volts unsheathed stranded copper conductor and one run of earth wire with one run of PVC conduit will be measured and paid in one length. |
| 76 | M&L switch Modular type 6 Amp SP one wayISI marked complete all as specified |
| 77 | M&L switch Modular type type 16 Amp SP one way,ISI marked complete all as specified |
| 78 | M&LModular type socket outlet 5 pin 6 Amp flush type,ISI marked complete all as specified |
| 79 | M&L Modular type socket outlet 2 in 1,5 pin 6/16 Amps, ISI marked complete all as specified |
| 80 | M&L switch bell push Modular type 6 Amps 1W-1 module, ISI marked 230V AC complete all as specified. |
| 81 | M&L bell electric (ding dong) 230 volt, SPall as specified and directed. |
| 82 | M&L ceiling rose 3 phase PVCpolycorbonate,isolated body, complete all as specified |
| 83 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.90, THD< 20%, colour temperature - 6500K, surge protection2.5 KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 140 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete.Note-All the above mentioned specs will be verified through LM 79 and LM 80 report of NABL accredited Lab before supply of LED fixtures. |
| 84 | Supply and fix LED batten luminaire surface mounted, 2 feet system wattage of 10 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.90, THD< 20%, colour temperature - 6500K, surge protection 2.5 KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 140 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete.Note-All the above mentioned specs will be verified through LM 79 and LM 80 report of NABL accredited Lab before supply of LED fixtures. |
| 85 | Supply and fixing ceiling fans three blade, Robust and reliable inverter motor (brush less DC Motor) powered by BLDCtechnology, BEE 5 star rating for energy saving, rated Air delivery >220 cum/min, service valve > 6, ACsingle phase 230/240 V of size 1200 mm sweepwith down rod, canopy, regulator etc including making connection with three core flexible, copper cable pvc insulated of suitable length, complete all as directed. |
| 86 | S&f exhaust fansAC single phase 230/240 V of size 300 mm sweep,Air flow rate > 900cum/min, Bird screen for protection against birds, double ball bearing, heavy duty, metal body with louvers for fixing of exhaust fan complete |
| 87 | Taking down carefully ceiling fan,exhaust fan, fresh air fan deposited to MES store yard all as specified & directed |
| 88 | S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 230 volts, 50 Hz, 10KA breaking capacity complete. |
| 89 | Schedule of Credit |