| 1 | Demolition of Lime concrete / Mud phuska / PCC of any description and in any position not otherwise specifically provided for renewal including taking down old tarfelt and removal of demolished material beyond the Md land to a distance exceeding 500mtr not exceeding 1.5KM completed all as specified and directed. |
| 2 | Taking down cement plaster or cement lime plaster of any description including racking out joints and hacking for key and scrubbing down withwater etcall as directed |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing unsrviceable tiles/debries outside MoD land and rubbish off the premises complete all as apecified and as directed |
| 4 | Dismantling plain or corrugated steel sheeting, AC Sheets any guage, thickness including Nainital or similar pattern roof covering/wall cladding complete all as specified and directed.(Note : height of the bldg truss is upto upto 7 Metre) all as directed |
| 5 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including snap grid of any type and cover fillets complete all as specified and directed |
| 6 | Demolition of brick work or stone masonry built in cement mortar including pillar etc. complete all as apecified |
| 7 | Dismantling timber scantlings 40 sqcm and over in section, unframed in any positionall as directed |
| 8 | Dismantling boarding, any description fixed in any position with nails including cover fillets and frame, complete all as specified and directed by Engineer-in-Charge. |
| 9 | Cutting grooves in brick/stone wall, 75mm wide and 65mm deep and shaping orizontal face ofthe groove with cement mortar 1:3 and all as directed |
| 10 | M&L 40mm thick PCC (1:2:4) type B0 using 12.5mm graded stone aggregate as in padding concrete (levelling course) on roof complete all as specified and as directed by Engr-in-Charge. |
| 11 | M&L for rendering 10mm thick in CM (1:3) on concrete surfaces of roof padding with integral water profing compound @3% by weight of cement content (water proofing compound to be paid separately) finished even and smooth without using extra cement complete all as specified and directed.Note: Water proofing compound will be measured and paid separately. |
| 12 | Supply only Integral water proofing compound |
| 13 | M&L for APP based polymeric membrane minimum weighing 3.5kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) including 10cm side over lap and 15cm end lap laid over primed surface by torching method all as specified and directed.The roof treatement consisting of as under :-(i) Applying one coat of bituminous primer conforming toIS 3384 applied @ 0.30 Ltr/Sqm.(ii) Laying of APP based memberane as specifiedf thickness and weight. (iii) Applying coats of Solar reflective Bituminous aluminium paint @ 0.1 Kg/ Sqm over the membrane |
| 14 | M&L for vetrified ceramic coloured tiles 8 to 10 mm thick area of each tile exc 0.36 sqm and not exc 0.72 Sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM 1:6complete all as directedcomplete all as specified and directed. |
| 15 | M&L for vetrified ceramic coloured tiles 8 to 10 mm thick area of each tile exc 0.36 sqm and not exc 0.72 Sqm in Skirting/dado over 10mm thick backing coat in CM 1:4complete all as specified and directed. |
| 16 | M&L for Non-skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including scread bed or bedding layer 15mm thick in CM 1:6 all as specified. |
| 17 | M&L for Non-skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.36 sqm, in Skirting/dado over 10mm thick backing coat in CM 1:4 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. |
| 18 | M&L glazed ceramic coloured tiles of any size and thickness on vertical surfaces such as dados/skirting, over 10mm thick backing coat in CM 1:4 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. |
| 19 | M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in leveling/beding PCC under floor finishesand as directed |
| 20 | M&L PCC 1:3:6 type C-2, 75mm thick using 40 mm graded aggregate as sub base/Plinth protection and pathcomplete all as specified and directed. |
| 21 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roofovering/cladding to wall, fixed with self tapping screws as specified |
| 22 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. |
| 23 | M&L for rolled mild steel sections of grade Fe-290,(Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and tubular section fixed vertically and guides for sliding doors; fixed with angle cleats or other connecting plates etc complete all as specified as directed. |
| 24 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel withconnecting clips cross the intermediate channel at 457 mm centre to centre. ® andall as directed |
| 25 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 26 | S&F PVC laminated designed (one side PVC lamination and other side Alumnium paper) gypsum board600 x 600 x8mm thick decorative type fixed in aluminium/GI frame work with screws or nails etc complete all as specified and directed by Engineer-in-Charge. |
| 27 | S&Fhorizontal level 15mm thick mineral fibre sound absorbing microlook sheetof size 600mm x600mm panels seamless falseceiling including seamless celing grid system with hot dippedgalvanisedsteelsectionssize 38mm x15mm exposedsurface withprecoatedcapping , main tee ofsize 24x32 mm at evrery1200 mm c/c andcrossteeofsize24 x27 mm ( 1200mm & 600 mm long ) at every 600 mm c/c andwall angleofsize 19x19 mm fixedtoperimeterwall,aspermanufacturer\"sinstructions , gridto besuspendedatevery 1200mmc/c in bothdirectionsby using 6mm dia pre-straightenedGI wireat every 1200mm c/c internalatthe main tee, completeall as specifiedanddirected. (Make - Armstrong, Everest, Gyproc) |
| 28 | M&L PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, coving, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directedincluding formed work complete all as specifed and directed. |
| 29 | M&L Brick work with Fly ash modular bricks straight or curved on plan to any radius in half brick thick walls built in cm 1:4 complete all as apecified |
| 30 | M&L for rendering 15 mm thick on brick or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement all as specified |
| 31 | M&L for rendering 10 mm thick on brick or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement all as specified |
| 32 | M&L for preparation of two coat of OBD over a coat of chalk whiting on plastered surfaces of primer on newely plastered surfaces of walls complete all as directed |
| 33 | M&L for preparation of two coat of cement base paint over a coat of alkali resistant primer on newely plastered surfaces of walls complete all as directed |
| 34 | Taking down eaves, gutters and rain water pipes including all fittings any size and pattern. |
| 35 | S&F PVC (SWR) 100/110mm bore single socketed pipes in any length with rubber ring joints fixed to wallwith pvc clamps complete. |
| 36 | S&F150 mm dia of PVC (SWR) Pipes of 6 kg/sqcm pressure rating, half round ready made eave gutter of approved make including necessary fitting like bend WC/MS Clips etc.and all as directed |
| 37 | M&L Up rooting of vegetation growth, shurbs, small plants and small trees of any size /girth from walls, roof chajja gutter, up to four storey at any location and position of bldg, including roots and making good the disturbed surfaces, cleaning the surfaces and making goodwith cement mortar (1:3) with WPC @ 3.0kg by weight of cement, each holes n exc 0.10 Sqm. Note : Rate including WPC |
| 38 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall. |
| 39 | M&L for Disconnecting existing tanks, setting side(or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position. exc 250 Ltrs but n .exc 1000 Ltrs capacity including cleaning and removing all scale and dirt.and all as directed |
| 40 | S&F 1000 ltr capacity of Rotational moulded PVC water storage tank three layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. |
| 41 | Taking up or down steel tubing & connections,15 mm dia complete all as apecified |
| 42 | Taking up or down steel tubing & connections,20 mm dia complete all asapecified |
| 43 | Taking up or down steel tubing & connections,25 or 32 mm dia complete all asapecified |
| 44 | S&F 15mm dia. Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe all as specifiedanddirected. |
| 45 | S&F 20mm dia.Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe and all as directed |
| 46 | S&F 25mm dia.Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe and all as directed |
| 47 | M&L for Refixing old steel tubing 15 to 20mm dia and connections in new or old position (Walls, ceiling, floors, etc.) |
| 48 | S&F in repairs 15mm bib taps fancy type chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferule and fixed |
| 49 | S&F in repairs,CP 15mm, stop valves/ angle cock, concealed type cast copper alloy with crutch or butterfly handle, screwed down, high pressure, screwed both ends for iron pipe complete all as specified |
| 50 | S&F 15 mm dia 600 mmlong PVC water connection with PTMT nuts and washersall as specified |
| 51 | S&F in repairs 15mm bore Fancy type pillar taps, long shank (swan neck), Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed. |
| 52 | S&F in repairs Gun metal globe or gate valves of 20 mm dia with iron wheel head screwed both ends for iron pipe and fixed in repair complete all as specified |
| 53 | S&F 20 mm bore dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (min weight 210gms) complete all as specified |
| 54 | S & F in repairs, vitreous china wash down water closet pan ( Pedestal pattern) including \"P\" or \"S\"trap with necessary fixing arrangement includingplasticwaterclosetseat coverwhitewithrecessedbottom andcoverfixed with aluminium hinging device complete all as apecified anddirected |
| 55 | S&F in repairs, PVC low level flushing cistern 10 litres capacitycomplete all as specified |
| 56 | S&Fin repairs, counter top vitreous china wash basin white flat back size 550x400mm with brackets including cutting for and pinning in ends of brackets or erecting stand including waste coupling CP brass 32mm dia with long screwed shanks & fly nuts & fancy type CP pillar tap complete all as apecified |
| 57 | S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) |
| 58 | S&F 75mmPVC (SWR) multi floor trap with grating including jointing with solvent cement |
| 59 | M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete |
| 60 | S&F in repairs 600x450mm bevelled edge mirror of selected quality glass, mounted on 06mm thick commercial ply wood backing including aluminiumframe and fixed in wall with wooden plug with chromium plated brass screws and cup washerswith glass self assembly complete all as specified and as directed by Engineer-in-Charge. |
| 61 | S&Fin repairssoap dish, vitreous china white, approximate size 160 x 160 x 90mm, fixed to plugs with chromium plated brass screws all as specified and as directed. |
| 62 | S&F in repair Vitreous China urinal (half stall type) flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe), complete all as specified and as directed by Engineer-in-Charge. |