| 1 | Supply and fixingreciprocating/rotary type company sealed compressor suitable for 1.5 ton capacity window AC of any make , cleaning of condenser/ cooling coil, charging of compressor oil, replacement of new bushes, washers, mounting rubbers, nuts & bolts , making it fully functional , testing completefixed in repair / replacement including taking out unserviceable unit from existing ACcomplete all as specified and directed. |
| 2 | Supply and fixingreciprocating/rotary type company sealed compressor suitable for 2.0 ton capacity window AC of any make , cleaning of condenser/ cooling coil, charging of compressor oil, replacement of new bushes, washers, mounting rubbers, nuts & bolts , making it fully functional , testing completefixed in repair / replacement including taking out unserviceable unit from existing ACcomplete all as specified and directed. |
| 3 | Dismantling and taking out window type air conditioner of capacity 1.5/ 2.0 Ton of any make/ type from its original location, carrying out maintenance/ overhauling cleaning with vacuum cleaner and greasing,including cleaning of condensers/ cooling coil, cleaning of air filter with caustic soda and water mixture & checking of connections complete servicing replacement of minor unserviceable parts such as rubber bushes, washers, mountingpad, rubbers, nuts & bolts, clips etc. and re-fixing the same aftertesting to same or other location complete all as specified and directed.Notes: (a) Spare parts (other than minor) including gas shall be measured and paid for separately under respective items of Schedule of Works. (b) The work under this item shall be executed on TOP PRIORITY basis to avoid inconvenience to the users as directed by Engineer-in-Charge and nothing extra will be admissible on this account. |
| 4 | Supply & refilling refrigerant gas R-22/R-410 after testing, rectification of leakage in the system with brazing/ welding complete all as specified and directed |
| 5 | Supply & fixing liquid line strainer in repair/replacement complete all as specified and directed. |
| 6 | Supply & fixing thermostatic switch for air conditioner inin repair/replacement complete all as specified and directed. |
| 7 | Supply & fixing PVC condenser fan bladematching with existing or superior quality type and model fixed in in repair/replacement complete all as specified and directed. |
| 8 | Supply & fixing blower drum matching with existing or superior quality and model fixed in in repair/replacement complete all as specified and directed. |
| 9 | Supply and fixing fan motor 1/5 HP single Phase 230 volts complete with base, nuts, bolts & washers to match with existing type and model fixed in repair/replacement complete all as specified and directed. |
| 10 | Supply & fixing air filter matching with existing or superior quality suitable for Window type AC 1.5/ 2.0 ton complete as specified & directed. |
| 11 | Supply and fixing in replacement condenser coil 4-row fins type fixed in repair/replacement as per existing type & model complete all as specified & directed. |
| 12 | Supply and fixing wiring kit as per original specifications with bronze thimbles and code marking fixed in repair/replacement complete all as specified & directed. |
| 13 | Supply and fixing cooling coil as per existing type and model fixed in repair/replacement complete all as specified & directed. |
| 14 | Supply only electronic type remote control suitable for 1.5 TR window type AC as per existing complete all as specified . Make: LG/ Videocon/ Voltas/Carrier |
| 15 | Supply and fixing circuit board electronic for window AC 1.5/ 2.0 ton fixed in repair/replacement complete all as specified & directed. |
| 16 | Supply and fixing front grill of window type AC of capacity 1.5 Ton complete with knobs, PVC filter etc. all as per sample including taking out old unserviceable grill complete all as specified and directed. |
| 17 | Supply and fixingreciprocating/rotary type company sealed compressor suitable for 1.5 ton capacity split AC of any make , cleaning of condenser/ cooling coil, charging of compressor oil, replacement of new bushes, washers, mounting rubbers, nuts & bolts , making it fully functional , testing completefixed in repair / replacemnt including taking out unserviceable unit from existing ACcomplete all as specified and directed. |
| 18 | Supply and fixingreciprocating/rotary type company sealed compressor suitable for 2.0 ton capacity split AC of any make , cleaning of condenser/ cooling coil, charging of compressor oil, replacement of new bushes, washers, mounting rubbers, nuts & bolts , making it fully functional , testing completefixed in repair / replacemnt including taking out unserviceable unit from existing ACcomplete all as specified and directed. |
| 19 | Dismantling and taking out split type air conditioner of capacity 1.5/ 2.0 Ton of any make/ type from its original location, carrying out maintenance/ overhauling cleaning with vacuum cleaner and greasing,including cleaning of condensers/ cooling coil, cleaning of air filter with caustic soda and water mixture & checking of connections complete servicing replacement of minor unserviceable parts such as rubber bushes, washers, mountingpad, rubbers, nuts & bolts, clips etc. and re-fixing the same aftertesting to same or other location complete all as specified and directed.Notes: (a) Spare parts (other than minor) including gas shall be measured and paid for separately under respective items of Schedule of Works. (b) The work under this item shall be executed on TOP PRIORITY basis to avoid inconvenience to the users as directed by Engineer-in-Charge and nothing extra will be admissible on this account. |
| 20 | Supply and fixing contactor single phase 230 volts AC 40 Amps coil range 208/ 240 volts fixed in repair/replacement complete all as specified and directed. |
| 21 | Supply and fixing capacitor 4 MFD, AC 230 volts dry type fixed in reapir complete all as specified and directed. |
| 22 | Supply & fixing fan motor 1/8 HP single Phase 230 volts complete with box and fan blades as per existing type and model or superior to existing for outdoor unit complete all as specified and directed. |
| 23 | Supply & fixing blower motor 1/20 HP single phase 230 volts complete with box and fan blades as per existing type and model for outdoor unit fixed in repair/replacement complete all as specified and directed. |
| 24 | Supply only remote control electronic type suitable for 1.5/ 2.0 TR split type AC complete all as specified and directed. Make: LG/ Videocon/ Voltas/Carrier. |
| 25 | Supply and fixing panel circuit board electronic for split AC 1.5/ 2.0 tonfixed in repair/replacement complete all as specified and directed. |
| 26 | Supply and fixing Tee valve of size 5/8″ and 3/8″ fixed in repair/replacement complete all as specified and directed. |
| 27 | Supply and fixing Tee valve of size 3/8″ and 1/4″ in replacement fixed in repair/replacement complete all as specified and directed |
| 28 | Supply and fixing wiring kit as per original specification with bronze thimbles and code marking fixed in repair/replacement complete all as specified & directed. |
| 29 | Supply and fixing running capacitor 36 MFD, AC 230 volts grade fixed in repair/replacement complete all as specified and directed. |
| 30 | Supply and fixing running capacitor 45 MFD, AC 230 volts grade fixed in repair/replacement complete all as specified and directed. |
| 31 | Supply and fixing starting capacitor 100-120MFD fixed in repair/replacement complete all as specified and directed. |
| 32 | Supply and fixing starting relay box type (suitable for off sizes split type ACs) fixed in repair/replacement complete all as specified and directed. |
| 33 | Supply and fixing copper tubing size 5/8″ including gas welding and making leak proof fixed in repair/replacement complete all as specified and directed. |
| 34 | Supply and fixing copper tubing size 3/8″ including gas welding and making leak proof fixed in repair/replacement complete all as specified and directed |
| 35 | Material and labour for black foam 4mm thick and 50mm wide for insulation, suction and discharge lines complete all as specified and directed. |
| 36 | Supply and fixing metal plug top 15 Amps, 3 pin 230 volts grade fixed in repair/replacement complete all as specified and directed. |
| 37 | Supply and fixingthermostatic switch of split type air conditioner 1.5/ 2.0 TR fixed in repair/replacement complete all as specified and directed. |
| 38 | S&F sheet metal enclosure single pole and neutral with 2 pin and earth plug and socket complete with 1 No. single pole 20 Amps 240 volts MCB complete including necessary fixing arrangement and connecting all incoming and outgoing electric connection fixed in repair/replacement complete all as specified as directed. |
| 39 | Attending complaints of non functional air conditioner of any make/ model/ type and making them serviceable within 48 Hrs after taking the complaint from the office complete all as specified and directed. Note: Items/ spare parts required to attend the complaint shall be measured and paid for separately under respective items. Note : A recovery of Rs 500/- per AC will be levied incase of non attending the complaint with in 24 hours . |
| 40 | Supply & refilling refrigerant gas R-132, R-134, R 410 after testing and rectification of leakage in the system with brazing/ welding complete all as specified and directed. |
| 41 | Taking down unserviceable/ burnt voltage stabilizer of capacity 5KVA from existing location and re-fixing it after carrying out necessary repairs/ rewinding/ replacement of transformer, repair/ replacement of faulty parts complete all as specified and directed. |
| 42 | Taking down unserviceable/ burnt voltage stabilizer of capacity 4KVA from existing location and re-fixing it after carrying out necessary repairs/ rewinding/ replacement of transformer, repair/ replacement of faulty parts complete all as specified and directed. |
| 43 | Supply & fixing new company sealed compressor suitable for existing water cooler/refrigerator of capacity 150/ 120/ 80 Litre (Fridge) and 190 - 300 Ltr (Water cooler), charging of compressor oil, refrigerant gas R-22/R-132/R-134 upto required pressure , replacement of foundation bushes & nuts/ bolts of existing size including dismantling & taking out unserviceable existing compressor complete all as specified and directed. |
| 44 | Supply and fixing condenser fan motor 1/16 HP capacity with blades and box plate suitable for refrigerator 190-300 Ltr capacity and water cooler 80-150 Ltr capacity fixed in repair/replacement complete all as specified and directed. |
| 45 | Supply and fixing condenser fan motor 1/10 HP capacity with blades and box plate suitable for refrigerator 190-300 Ltr capacity and water cooler 80-150 Ltr capacity fixed in repair/replacement complete all as specified and directed. |
| 46 | Supply and fixingcondenser fan motor 1/8 HP capacity with blades and box plate suitable for refrigerator 190-300 Ltr capacity and water cooler 80-150 Ltr capacity fixed in repair/replacement complete all as specified and directed. |
| 47 | Supply & refilling, refrigerant R-22/ R-132, R-134 after testing, rectification of leakage in the system of refrigerator/ water cooler of any make and capacity with brazing/ welding work complete all as specified and directed. |
| 48 | Supply and fixing push cock 15mm dia chromium plated self closing (Heavy duty) as per existing size for water cooler of any make and capacity fixed in repair/replacement complete all as specified and directed. |
| 49 | Supply & fixing in repair/replacements PTMT float valve 15mm dia bore with high density polyethylene and brass rod fixed in repair/replacement complete all as specified and directed. |
| 50 | Supply and fixingthermostatic switch for water coolers fixed in repair/replacement complete all as specified and directed. |
| 51 | S & F capacitor 40 MFD capacity suitable for 80 to 160 litres water coolers complete all as specified and directed. |
| 52 | Supply & fixing fan motor 1/8 HP single phase 230 volts complete with legs, fan blades, nuts, bolts & washers etc. including dismantling & taking out unserviceable burnt fan motor complete all as specified and directed. |
| 53 | Supply & fixing water lifting pump 1/70 HP AC single phase 230 volts including taking out unserviceable water lifting pump complete all as specified and directed. |
| 54 | Supply & fix selector switch with knob (as per sample) fixed in repair/replacement complete all as specified and directed. |
| 55 | Supply & fixing wood wool pads as per existing size and type fixed in repair/replacement complete all as specified and directed |
| 56 | Supply and fixingPVC insulated copper conductor flexible cable of size 70/.0076, 3 core fixed in repair/replacement complete all as specified and directed. |
| 57 | Supply and fixing PVC insulated copper conductor flexible cable of size 40/.0076, 3 core fixed in repair/replacement complete all as specified and directed. |
| 58 | Supply and fixingfront grill made out of PVC/ GI sheet including selector switch, indication lamp fixinged on GI front sheet 0.7mm thick, suitable for air flow capacity 4000/ 5000 CFM desert cooler including taking out old unserviceable front grill alongwith front sheet complete all as specified and directed. |
| 59 | Supply and fixing fan blades as per requirement for desert cooler 4000/ 5000 CFM including taking out old unserviceable fan blades complete all as specified and directed. |
| 60 | Supply and fixing PVC connection with complete accessories suitable for desert cooler 4000/ 5000 CFM with flair nuts, PVC connector and washers suitable for 15mm bore complete all as specified and directed. |
| 61 | M&L for fabrication of desert cooler body made using 20 gauge PGI sheet suitable for evaporative type desert cooler of suitable size with water tank of min height 20cm duly fitted with side panels made out of 20 gause PGI sheet & grill with fins electrical wiring and connection with ON/ OFF switch piano type with distribution PVC cup and elbow, PVC pipe connection, PVC cable 3 core 23/.0076 - 3 Mtr fitted with 01 No. 5 Amp top plug including painting the complete body internally and externally with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer in repair/replacement / replacement complete all as specified and as directed. |
| 62 | M&L for fabrication of angle iron stand of suitable size to place desert cooler made out of angle iron of size 35mm x 35mm x 5mm including two coats of synthetic enamel paint of approved colour over a coat of red oxide primercomplete all as specified and directed by the Engineer- in-Charge. |
| 63 | S & F capacitor 6 MFD capacity suitable for 4000/5000 CFM desert cooler complete all as specified and directed. |
| 64 | Note: The Total amount shall subject to adjustment of credit of Rs. 58,595.00 for old Materials as per Schedule of Credit. |