| 1 | Supply & fix in replacement of unserviceable PVCloft tank (HDPE) of capacity 275 ltrs with complete fitting including 03 Nos adopter with washer for inlet/outlet over flowas per manufactureres instructions complete all as specified and directed by Engineer-in-Charge |
| 2 | Supply and fixing replacement PVC profile suitable for 275 ltr loft tank including fixng of aluminium channel around the profile complete all as specified and directed by Engg-In- Charge. |
| 3 | M& L for Cleaning of loft tanks of capacity 170 to 275 ltrs in existing position by mechanised pressure, cleaning using PVC tank cleaning solution and draining out the water by wet vaccum pump, rinsing with clean drinking water complete all as specified.Note : Any damage to pipe and PVC tank during cleaning shall be made good by the contractor at his own cost. |
| 4 | Cleaning of underground sump of any capacity cleaning the floors, wall and ceiling portion of sump etcby Mechnical high pressure spray and steel wire brush to remove Algae/dirt/foreign dirt completely and soaking out the water/dirt with a high pressure wet vaccum pump and removing spoilsout side of MD land land distance exc 5 KMs & n.exc 10 KMs and applying spray of approved chemical etc. complete all as specified and as directed by Engineer-in-charge .Note :- 1.Rates deemed to be included for pumping out water left below foot valve.2.Rate include the painting of two coats of enamal paint with visible colour on all sides and writing capacity of sump about date of cleaning and due date for cleaning complete all as specified. |
| 5 | Sump capacityof approximately 9,20,000 liters |
| 6 | Sump capacityof approximately 16,00,000 liters |
| 7 | Sump capacityof approximately 14,00,000 liters |
| 8 | Sump capacityof approximately 4,50,000 Liters |
| 9 | Sump capacityof approximately 3,20,000 Liters |
| 10 | Sump capacityof approximately 2,20,000 Liters |
| 11 | Sump capacity of approximately 2,40,000 Liters |
| 12 | Sump capacity of approximately 1,40,000 Liters |
| 13 | Cleaning of PVC and RCC water storage tank in low and high rising buildings(G+14) by mechanical high pressure spray and remove all foreign matter completly and soakingout the water/dirt with a high pressure wet vaccum pump and removing spoilsout side of MD land andcomplete all as specified and as directed by Engineer-in-charge . Note: Rate include the painting of two coats of enamal paint with visible colour about date of cleaning and due date for cleaning complete all as specified. |
| 14 | OH Tank ofcapacity 2000 Litres |
| 15 | OH Tank ofcapacity 5000 Litres |
| 16 | OH Tank ofcapacity 3000 Litres |
| 17 | OH Tank ofcapacity 10000 Litres |
| 18 | OH Tank of capacity 15000 Litres |
| 19 | S&F in replacement FRP lid cover for PVC water storage tank complete accessory for closing and locking arrangement suitable for various capacitys as approved by BMC |
| 20 | For capacity of 5000 litres |
| 21 | For capacity of 3000 litres |
| 22 | Cleaning thevegetation including grass, bushes small trees and all vegetation growth complete including uprooting of bushes and small trees around the installation/sump/OH reservoir, valve chamber etc. filling the rough holes with earth and levelling the surfaces by removing all debris to a distance n.exc.50m complete all as specified and directed. |
| 23 | Supply/Fixingin repair/replacementofinternal steel water tubing with CPVC pipes SDR 11 & PlainCPVC SDR 11 fittings in wall and shaftsincluding necessary saddling andand work to be done in high rise building up to 15 th floor short piece/length, includingbreaking the existing brick wall for replacement ofcorroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge of the following size :- |
| 24 | 20 mm Nominal outside dia |
| 25 | 25 mm Nominal outside dia |
| 26 | Supply & Fixing in repairs Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks, ladders and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc with Fe 410 -W (Gde- E- 250) including making paint with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Note:Contractor should survey each quarter in old and new navy nagar and highlyrusted angle should be change accordingly. |
| 27 | Material and labour for bacteriological and chemical analysis of water sample at govt approved lab (Iso 9001:2008)including collecting sample from pumphouse using labedownedsample jar and testing every month all directed and specfied by Engineer-in-charge |
| 28 | Checking of over head tanks of any capacity , making arrangement of mosquito proofingof the tank from overflow side with new GItank nipples, socket, barrel nipple , elbow, MS wire net, locking the existing tank cover to avoid entry of lizards, mosquitos inside the tank, tightening of all inlet and out let connections to make the tank no leaking of watercomplete including painting with white colour paint on base coat and writing theletters of black colour of the following details all as specified and directed :-(a)Date of cleaning (b)Date of Next due(c)Tank capacity |
| 29 | Supply, Installation Testing & Commissioning in repair of Motor Actuated Butterfly Valve (With manual operating wheel)consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 300mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure.Specifications & FeaturesInput Voltage: 230 V, A.C., Designed line pressure: 16 kg/sq cm.Operating Angle: 90 degrees,Disc Material: CI with nylon coatingLimit Switches : 02 Nos.For open and close status Mounting : Extended type with universal joint for installation 18-24 inches above the pipe level with angle mounting including raising of existing chamber as required at site. Note :-1. Rates also including of cutting, welding and any modifications in existing line with suitable DI/CI fittings with joints and its fixing are completely included in the item rate and no extra cost will be claimed by the contractor.Make :- Emtork/Hasel Hofener/Ritetork/Siemens/HoneywellNote :-2 Contractor\"s shall visit the site before quoting the rate of the item. |
| 30 | All as per item No. 12 above but capacity of motor actuated butterfly valve of size 200 mm dia complete all as specified and directed |
| 31 | All as per item No. 12 above but capacity of motor actuated butterfly valve of size 100 mm dia complete all as specified and directed |
| 32 | All as per item No. 12 above but capacity of motor actuated butterfly valve of size 80 mm dia complete all as specified and directed |
| 33 | All as per item No. 12 above but capacity of motor actuated butterfly valve of size 50 mm dia complete all as specified and directed |
| 34 | Supply & fixing in repair on wall/ laying in trench 4C x 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable. (Make: POLYCAB/FINOLEX/Havells) |
| 35 | Supply & fixingin repiar wall/ laying in trench 6Cx 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable. (Make: POLYCAB/FINOLEX/Havells) |
| 36 | S&F in replacement PVC water storage Tank with cover 3 layer, ISI marked, pure anti microbail round typeand making connections including replacement of new GI fittings i.e. tank nipple, washers, float valves and Gate valves and Pipes for connecting the existing Inlet/delivery lines, testing complete all as specified and directed for the following capacity :-Note :- Gate valves and GI pipe only shall be paid under relevant item of Schedule \"A\" remaining items shall be deemed to be included in the item rate. |
| 37 | 5000 Ltr capacity |
| 38 | 3000 Ltr capacity |
| 39 | 2000 Ltr capacity |
| 40 | 1000 Ltr Capacity |
| 41 | Supply and fixing in replacement , Installation, Testing and Commissioning of Float type Point Level Sensor with the following specifications;Type: MagneticMagnet: Ring typeSwitch: Reed Switch (Epoxy sealed)Connecting Cable: Teflon |
| 42 | Supply and fix in repairs in existing line, gun metal gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified of following sizes :- |
| 43 | 40 mm bore |
| 44 | 50 mm bore |
| 45 | 80 mm bore |
| 46 | 25 mm bore |
| 47 | Supply and fix in repairbrassfloat valve (ISI marked) high pressure with polythelene float (flat) and fly nut complete screwed for GI pipe 15mm bore including necessary GI fittings such as elbow, reducer, nipple etc. |
| 48 | All as per item No 22.00 above but for GI pipe 25 mm bore |
| 49 | All as per item No 22.00 above but for GI pipe 40 mm bore |
| 50 | Supply and fixing in repair/ replacement , Installation Testing & Commissioning of Indoor type Programmable Logic Controller based Valve Automation and communication Panel suitable for control and/or monitoring of 18 Nos motorized valves and 28 Nos. magnetic sensors . The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated. The Panel should have the following features: -(a)Automatic Operation of Motor Actuated Valves (b)01 No. SMPS of 5 A rating (Make: SCHNEIDER / NHP)(c)Suitable no. of interposing relays 24 V D.C. coil rating, 4 pole and 2 A contact rating. (Make: OEN / OMRON / IDEC / ALLEN BRADLEY)(d)MCB of rating 10A -01 No.(Make: Havells/ Schneider)(e)Selector Switches as per requirement(Make: SCHNEIDER / ESBEE).(f)Compatible with OFC based communication Ethernet Switch –16 port GBPS layer 2 manageable switch, Make Cisco, Dlink, Redundant GPRS modembased communication module comprising of one Main and One standby Modem with suitable antenna, modem controller and 02 Nos. data enabled SIM cards (01 No per modem) using two different service providers. The module shall be programmed to automatically toggle between the service providers based on the actual signal strength. switch to the stand by modem in case the main modem fails, Compatible for Wimax Connectivity if required. |
| 51 | To make the system fully functional. all panels shall be consisting ofthe following :-(a) Rack mountable Web Smart Switch with 28 ports and POE for CPE hardware and following specifications:-(i) Number of Ports24 10/100Base-TX Ethernet ports2, 10/100/1000BASE-T2 Combo 10/100/1000BASE-T/SFP.(ii)Port StandardSupply and fixing unctions • IEEE 802.3 10BASE-T Ethernet (twisted-pair copper) • IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted-pair copper) • IEEE 802.3x Flow Control • IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper) • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 Switching Capacity • 12.8 Gbps Make : Siemens, Dlink, Ubiquiti, Cisco |
| 52 | (b) Hot pluggable 1310 nm multimode/Single mode SFP (mini-GBIC) transceiver, supporting full duplex, Gigabit speeds on multimode/Single mode fiber for distances of up to 550m/550m/10km on 62.5µm/50µm/9µm respectively in a metal housing to reduce EMI and to increase durabilityMake : Dlink, Ubiquiti, Cisco, Siemens, HP(c)Rack Mountable LIU with the following specifications:-(i) Rack Mountable 12 Port Unloaded LIU(ii)Aluminium Base Material(iii) Slim 1 U mounting height(iv) Metal Shelf Aluminium 1.2 mm thick(v) Splice tray Aluminium 0.6mm (vi) Winding Panel – Plastic(vii) Cable Plug – Rubber for minimum 2 cable entries (viii) Adaptor Panel Aluminium 1.5 mm thick(ix) 2 fiber spools built in for 900 um tight buffered fibre storing(x) Capable of storing upto 3 mts of 900 um tight buffered fibre per adaptor |
| 53 | (d)SC-LC Duplex SM Patch Cord 0.9 mm dia of suitable length (i)Size 0.9mm dia(ii) Insertion Loss <=0.2 db, max 0.3 db(iii) Return Loss PC>=45dB, UPC>=50dB, APC>=60dB (iv) Connector Ferrule Ceramic(v) Apex Offset <50um (vi) Fiber Height +-100nm (vii) End Face Radius of Curvature 7mm=45dB, UPC>=50dB, APC>=60dB(iii) Connector Ferrule Ceramic (iv) Apex Offset <50um (v) Fiber Height +-100nm(vi) End Face Radius of Curvature 7mm |
| 54 | (h)CAT6 UTP 24 AWG Patch Cord of suitable length, Plug 30U snag less Make : Dlink, FinolexSeamless Integration of the above PLC Panels into the Existing SCADA System incorporating (a)Development:(i)SCADA Screens for new Updated Panel configuration(ii)Layout for App new Updated Panel configuration(iii) Report Format new Updated Panel configuration(b) On-site development:(i)Modifications in SCADA Screens (ii) Modifications in reporting format(iii) Modifications in App layout |
| 55 | The quoted cost shall deem to include the cost of communication for 12 months from the date of completion.Above All automation panel should connected to existing SCADA server and anyother leftout devicesand accessories require to commissioning should be consider and same should be include in quoted rates and department will not pay extracost for the same.Make of Control Panel: Cimcon Software Pvt Ltd/ Reckronic Devices and Systems / Sombansi Schneider/UniversalSwitchgear. Note :- Cost for Synchronising of panel in to existing SCADA system is in contractors scope only and no extra payment shall be given to the contractor by the department. |
| 56 | Taking down cement plaster of any description etc. including raking out joints, hacking for key, scrubbing down withwater, etc. Including removal of debris out side MD land complete all as specified and directed by Engr-in-charge. |
| 57 | Providing and applying fair finish 15mm thick plaster with ready mix prepacked proportioned dry mix mortar fair faces of brick wall or concrete surfaces, wall surfaces including transporting of material, mixing, curing, etc.complete as per direction of Engr-in-chargeNote:- (i) Liquid water proofing compound will be measured and paid seperately as supply only |
| 58 | Supply only liquid water proofing compound. |
| 59 | Providing and applying fair finish 10mm thick plaster with readymix prepacked proportioned dry mix mortar fair faces of brick wall or concrete surfaces, on ceiling including transporting of material, mixing, curing, etc.complete as per direction of Engr-in-charge. |
| 60 | M& L for applying 1mm thick wall care putty on walls complete all as specified and directed by Engr-in-Charge |
| 61 | M & L for preparing new surfaces of wall and apply two coats of distemper oil emulsion white or tinted over and incl one coat primer on walls complete all as specified and directed by Engr-in-Charge. |
| 62 | M & L for preparation of old wall surface and applying one coat of distemper oil emulsion white or tinted complete all Sqr as specified and directed by Engr-in-Charge. |
| 63 | M & L for preparation of newly plastered surface of ceiling and applying two coats of distemper oil emulsion white ortinted over one coat primer complete all as specified and directed by Engr-in-Charge. |
| 64 | Providing & applying anti algal water-based Elastomeric exterior wall finish newly plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per ltr coverage area and application of two coats (base coat 4.2-4.7 & top coat 6-6.5 sqm per ltr coverage area) of paint by roller etc. complete |
| 65 | Material and labour for applying two coats of oil emulsion distemper over a coat of primer including 1mm thick wall care putty on old decorated surfaces of wall. Complete all as specified and directed by Engineer-In-charge |
| 66 | Material & Labour for applying two coats of oil bound distemper on old decorated ceiling incl complete removal of existing treatment by washing, rubbing down and over 1mm thick putty in two layer complete all as specified and directed by Engineer-In-charge. |
| 67 | M&L cleaning the existing surfaces of chequered tiles/paver blocks and applying one coats of floor guard paint (1st Sqm quality as approved by GE) complete all as specified and directed by Engr-in-charge |
| 68 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof Coverings coverings. |
| 69 | ML pre-painted galvatume aluminum zinc coating Gl based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including making grooves of minimum 50mm into brick walling and inserting the sheets into these grooves including working platform/scaffolding) Complete all as specified and as directed by Engr-in-Charge |
| 70 | S&Fin replacement SMC PANEL TANK confirming to Panel must be ISI Marked and have ISI Logo with CML and Batch Number along with ISI Code.(ISI 14399 Part-1 & Part-11-2006) of the under mentioned size (3mt x 2mt x 1mt) and capacity (06 KL.)Made out of HOT PRESS MOULDED SHEET MOULDING COMPOUND (SMC) Panels of size 1005mm X 1005 mm. The flange should be perpendicular to the main surface. The shape should be Trunk Type for extra strength and 90 degree flanges predrilled for bolting. All the Flanges of the Panel should have maximum 13 Nos. holes for fastening/joining the panels to one another. Hot Pressed Moulded SMC Pre Drilled Corner Pieces with built-in ribs of the size 75mm X 75 mm should be provided for 90 degree joints of tank walls or wall to base or wall to roof joints complete Hot Dipped Galvanized (HDG) hardware nuts, bolts and washers. Special sealant having excellent UV Resistance as well as suitable for portable water, complete with Top Covered construction having Man-Hole with Cover of Dia 600mm and internal FRP Ladder. The tank after erection and assembled as per Manufacturer Specification\"s shall be filled with water upto overflow level, which will be placed near the roof of the tank and test for leakages rectified any leakage found during the testing should be rectified to make it 100% leak proof complete as per direction of Engineer-in-Charge. (ISI Logo & CML number must be printed on all Panels). NOTE: (i) Rate quoted shall deemed to be inclusive of internal and external ladder made out of FRP/ Pultruted Section. MS supporting channels and necessary PVC profile including FOUNDATION, GRILLAGE, UNLOADING, SHIFTING & OTHER CIVIL COMPONENT IN CLIENT SCOPE. Including demolition/dismantling of RCC Storage tank. |