| 1 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars etccomplete all as specifiedand as directed. |
| 2 | M&L for brick work with sub class \"B\" bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1:6 omplete all as specifiedand as directed. |
| 3 | All as per item no 2 before but except bricks |
| 4 | Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in in soft/loose soil complete all as specifiedand as directed. |
| 5 | Returningfilling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil omplete all as specifiedand as directed. |
| 6 | Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil omplete all as specifiedand as directed. |
| 7 | M&L for PCC 1:2:4 type B1 using 20mm graded aggregates as in surfaces channels and drains complete all as specified. |
| 8 | M&L for cement concrete 1:2:4 type B1(using20mm graded stone aggregate) as in blocks for hold fast, coping,benching etc. including weathering, slightly rounded or chamfered angles or throating including form work to concrete surfaces, complete allas specified and directed. |
| 9 | Taking down cement plaster in concrete or brick wall surface of any thickness from brick or stonewalls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 10 | M&L for rendering 15mm thickon fair faces of brick work or concrete surfaces in CM 1 : 4 mixedfinished even and smooth without using extra cement complete all as specified. |
| 11 | M&L preparation of old plastered surfaces of work and applying two coats of cement base paint all as specified and directed. |
| 12 | S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps etc complete all as specified. |
| 13 | S&Fin repair 110mm dia of any radius PVC (SWR) bends |
| 14 | S&F DWCPE(SN4) 150mm dia (Internal Dia)pipes,snap fit coupler and rubber ring incltesting and laid and properly jointed laid in trenches to a level on concrete bedincluding demlition of exiting pipes complete all as specified. |
| 15 | S&F DWCPE(SN4) 200mm dia (Internal Dia)pipes,snap fit coupler and rubber ring incltesting and laid and properly jointed laid in trenches to a level on concrete bed including demlition of exiting pipes complete all as specified. |
| 16 | S & Ffor precastplastic fibre reinforced cement concreteManhole coverincluding grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mm & 75 mm thick complete all as specifiedand as directed. |
| 17 | S & Ffor precastplastic fibre reinforced cement concrete Manhole covers with frame medium duty of overall size 450mmx450mm & 50mm thick factory made all as specified and directed by Engr-in-Charge. |
| 18 | S & Ffor precast cement concrete Manhole covers with frame medium duty of overall size 300mmx300mm & 25mm thick factory made complete all as specified and directed by Engr-in-Charge. |
| 19 | S & Ffor precastplastic fibre reinforced cement concretedrain coverincluding drain hole, grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mm & 75 mm thick complete all as specifiedand as directed. |
| 20 | Cleaning ofEWCs, IWCs, bottle traps, Nahani Traps, Gully traps and Floor traps etc and CI/PVC Pipes all types top to bottom including junctions etc,Cleaning of sewage line upto GTin the area of Pratap Chowk and Adjoining Area(Md accn and all types of Accn). complete all as specifiedand as directed. |
| 21 | Cleaning of GTs in the area of Pratap Chowk and Adjoining Area (Md accn and all types of Accn) complete all as specifiedand as directed. |
| 22 | Cleaning of Manhole depth ofupto 1.20mtrin the area of Pratap Chowk & Adjoining Area(Md accn and all types of Accn) and taking out sludge and depositing ,cleaning of all sludge, silt residue of both organic and inorganic nature by manual labour or by mechanical scrappers etc and disposal off the same out side the defence area notified by Municipal Corporation of Delhi all as directed by Engr-in-Charge. |
| 23 | Cleaning of Manhole depth exc 1.20mtr to upto 3.00 mtr in the area of New Pratap Chowk , Arjan Vihar & Adjoining Area (Md accn and all types of Accn) and taking out sludge and depositing ,cleaning of all sludge, silt residue of both organic and inorganic nature by manual labour or by mechanical scrappers etc and disposal off the same out side the defence area notified by Municipal Corporation of Delhi all as directed by Engr-in-Charge |
| 24 | Cleaning of sewage line n.exc 10mtr in lengthin the area of Pratap Chowk & Adjoining Area (Md accn and all types of Accn). complete all as specifiedand as directed. |
| 25 | Cleaning of Sewage line 0.00mtr to 20.00mtr in length in the area of New Pratap Chowk , Arjan Vihar & Adjoining Area (Md accn and all types of Accn) omplete all as specifiedand as directed. (Note :- This item will be measured if length exceed from 10.00mtr.) |
| 26 | S&F in repair vitreous China European type WC with \"P\"trap 1st quality including connection to drain and fixing bolts incl plastic water closet seat cover complete all as specified and directed. |
| 27 | S&F in repair vitreous china squatting pan of orrissa pattern long pan size 580mm white with \"P\"or \"S\" trap front or back inlet and integral footrest any pattern (excluding flushing cistern and flush pipe) including Provn of concrete bedding complete all as specified and directed. |
| 28 | Mechanically used high pressure Super Sucker Machine capable of Air lifting of dense sludge like muds, slurry, small stones, debries, grits etc from sewer lines/Manholes thorough vaccum mode and capable of Jetting sewer lines of any dia. The machine shall be used by the contractoras per direction of Engineer-in-Charge as on required basis. Job shall be completed to the entire satisfaction of GE..Note: Rates quoted cleaned for 08 hrs of super sucker machine. Any work carried out throughout 08 hrs shall be measured as on Job. |
| 29 | M& Lcement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection 75 mm thick laid in bays and surfaces finished even and fair including demolition of existing surface all as specified and disposing to debries etc all as directed |
| 30 | Demolition of cement concrete in ground floor and pavings n exc 15cm thickness (below or above ground level) complete all as directed. |
| 31 | M& L for rubble moulded Chequered cement concrete colourtiles 30 cm x 30 cm x 25mm thick with mixture of grey cement & pigment set jointed and pointed in neat cement slurry in floors including 15mm thick screed bed inC M 1:6 complete all as specified and as directed. |
| 32 | M & L Machine pressed precast concrete interlocking dark colouredpaver block any shape and size confirming to IS 15658-2006 of 60mm thicknessM-35 Grade all as specified and disposing to debries etc all as directed by Engr-in-Charge. |
| 33 | M&L sand filling under floors or in foundation including watering and consolidation |
| 34 | M & L Cement concretetype C-2, 1:3:6 (40 mm graded stone aggregate) in foundations, filling and mass concreteas in sub base all as specified. |
| 35 | Supply and fix in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenchesor in floors or fixed to walls with FI clamps etc,bore of pipe 100mm complete all as specified and directed. |
| 36 | Supply and fix in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenchesor in floors or fixed to walls with FI clamps etc,bore of pipe 75mm complete all as specified and directed. |
| 37 | Supply and fix cast iron Bends (sand cast) (any radius), diminishing pieces or tapers soil/waste pipes 100mm dia bore with or without duck\"s foot or heel restin any length (larger bore measured) complete all as specified and directed. |
| 38 | Supply and fix cast iron Bends (sand cast) (any radius), diminishing pieces or tapers soil/waste pipes 75mm dia bore with or without duck\"s foot or heel restin any length (larger bore measured) complete all as specified and directed. |
| 39 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed by Engineer-in-Charge. |
| 40 | S&F in pre painted galvalume aluminum ZINC coating GI base corrugated steel 0.5mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall fixed with self tapping screw with minimum 150mm end lap and one corrugation side lap including dismantling the existing sheets complete all as specified and directed. |
| 41 | S & F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates |
| 42 | M & L for painting new or previously untreated steel and iron surfaces of any description, over 10cm in width or girth,not otherwise described with two coats of synthetic enamel paint over a coat of red oxide complete all as directed. |
| 43 | M&L for dismantling tiles laid dry or pointed of any size and thickness in walls and floors and complete removal of debris outside MOD land complete all as specified and directed. |
| 44 | M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes of cement plaster 1:6 complete all as specified and directed. |
| 45 | M&L for coloured ceramic tiles (Non skid) of size 300x300x 7-8mm thick as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement over 15mm thick screed bed in CM 1:6 complete all as directed. |
| 46 | S & F for Non - skid Ceramic tiles 7-8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm( size 400 mm x 400 mm), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over complete all as specified and as directed. |
| 47 | Schedule of Credit |