| 1 | Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixture and fittings such as switches,ceiling roses, pendants, regulators, sockets, light fitting etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 2 | Taking down submain wiring of any description and any type/size. |
| 3 | Taking down copper/aluminium earth strip of any size/type, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, or roof etc. |
| 4 | Taking down MCB distribution board of any rating/type/size or other descriptions. |
| 5 | Taking down MCBs/MCCBs of any rating/type/size or other descriptions. |
| 6 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earthstrip 25x4 mm by means ofnut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991)(a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 15 mm nominal bore medium grade GI protection pipe 7.5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 7 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm by means ofnut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991)(a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 15 mm nominal bore medium grade GI protection pipe 7.5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 8 | M&L for earth electrode 17.2mm dia 3 mtr long of low Carbon steel electrode with copper bonding of thickness 250 micron, back-fill earthing enhancing compound AXIS ULTRA/AXIFILL type Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per clause 14.5D of IEEE:80 standard. Back-fill compound should be electronically conductive (like in Metals) and should not depend on moisture for conduction. Back-fill compound should be environment friendly & should be solidify when mixed with water and set like concrete and should not leach/diffuse into the ground.Back-fill compound shall not be mixed with any type of soil while pouring in the bore hole.Test certificate as per IEC:62561-7 for back-fill compound shall be submitted alongwith the material including SS clamps and PVC earth pit 300x300mm with plastic lid to be provided both sides,complete all as specified. NOTE: (i) Earth electrode should be as per standards of IS:3043, IEC 62561-2 and IEC: 60364-5 and made of high tensile rod copper bounded, high tensile strength good electrical conduction & effective performance and suitable for all type of soil and minimum depth of earth pit should not be less than 4 mtr deep. (ii) Back-fill compound should be compliance to the standards IEEE:80, IS:3043, BS 7430, IEC 62561-7, ANSI/NSF 60 certification. (iii) Provide positive low resistance electrical connections to the earth.(iv) Does not contain hazardous chemicals. (v) Electronically conductive (Like in metals) and sholud not depend on moisture. (vi) Provide the desired value of earth resistance as per required specified value.(vii) Provide the Exothermic welding joints to entire grid system of earthing electrode. (viii) Test certificate to be provided for each electrode separately. |
| 9 | M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron. |
| 10 | M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip. |
| 11 | M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip. |
| 12 | Supply, installing, testing and commissioning factory made and tested LT Panel Indoor type, platform mounted of size: 800 X 300 X 1200 mm (LxWxH) suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Copper bus bars of capacity 250 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, IP-42 and made out of 2.00 mm thick CRCA mild steel sheet Wall mounted type, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade complete all as specified and directed by Engineer-in-Charge. The scope of work also comprising of the following:- BUS BAR CHAMBER:- (a) 250 Amp TPN, Copper conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER:- (i) Volt Meter,96mm,flush type rated 0-500V, Digital type with Volt Meter selector switch- 01 Set. (ii) Amp Meter,96mm,flush type rated 0-200A, Digital type with suitable size C.T\"s, and Amp Selector switch- 01 Set (iii) RYB Phase indicating light LED type with MCB 2A SP C Series- 1 Set of three. INCOMING:- (i) MCCB 160 Amps 25 KA , 4 Pole with adjustable thermal magnetic release=01 No., Make of MCCB:- Siemens / Legrand/ Schneider.OUTGOING:- (i) MCB 2 Pole 63 Amps, 415 volts , 50Hz, 10 KA = 04 Nos(ii) MCB 2 Pole 10 Amps, 415 volts , 50Hz, 10 KA = 01 Nos. (iii)Provision for Prepaid meter (Meter provided by MES ) (v) Panel wiring for control circuit with copper flexible 1.5 Sq mm& powerwiring minimum 10 Sqmm flexible.Note :- (i) Marking of Flat Nos on outgoing feeders of LT Panel. (ii) Time duration for replacement of LT Panel should not be more than 4 Hours. (iii) Rate quoted are deemed to be inclusive of all the fixture /fittings cater above |
| 13 | Supply and fixMCB DB SPN 4 way Horizontal, IP-43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link complete. |
| 14 | Supply and fixMCB DB SPN 8 way Horizontal, IP-43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link complete. |
| 15 | Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link completeall as directed by Engineer -in- Charge. |
| 16 | M&L sheet metal enclosure for DBs when MCBs to be used triple pole and neutral double door with 200 amps rated bus bar 4 ways complete. |
| 17 | Supply and fixing in replacement 415V, 10KA \"B\" curve miniature circuit breaker (MCB) of three pole and neutral and current carrying capacity 16 to 32 amps complete with connection testing and commissioning. |
| 18 | Supply and fixing in replacement miniature circuit breaker (MCB) of single pole and neutral and current carrying capacity 40 amps 240V 10KA\"C\" curve testing and commissioning. |
| 19 | Supply and fixing in replacement 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. |
| 20 | Supply and fix in repair MCCB 160 Amps, FP 415 volts 25 16KA, 4 pole 50 HZ with thermal magnetic setting complete all as specified and directed. |
| 21 | S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. |
| 22 | S&F in repair Sub main wiring with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. |
| 23 | Supply and fixing cast aluminium/cast iron decorative pole suitable for land scapining LI-8206 type of height not less than 2.165 mtr including PCC foundation of suitable ratio and depth not ness than 45cms and nuts, bolts and washers grouted in PCC foundation to erect the pole vertically and making light connections all as specified and directd. |
| 24 | Supply andfixing post top light fittings cast aluminium base, spun aluminium top, acrylic diffuser, stainless screws, corroson and UV rays rasistant coating complete LI-50030 S-40 type with LED lamp 40 watt and making necessary electrical connection with suitable size copper multistranded cable 1100 volts grade and testin on completion all as specified and directed by Engr-in-Charge. |
| 25 | S&F not less than 60 Watt High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarieshould more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP-66 protected.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 180-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision ofsuitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wallcomplete as specified and directed. |
| 26 | GI bracket 40mm/50mm bend to shape including clamps,nuts, bolts and washers and grouting in wall and painting with two coats of black enamelled paint over a red of red oxide primer all as specified. |
| 27 | M&Lcopper three core cable 1.5 sqmm for connecting street light with connector all as directed. |
| 28 | Taking down of old unsv garden/gate light fittings of any description including service connection/wiresof any dia or size and accessories etc complete. |
| 29 | Supply and fixing LED post top light die cast aluminium housing spigot, powder coated top cover opal PC diffuser having IP 65 protection complete of 20/25 watt including making necessary electrical connections with suitable size copper multistranded cable all as specified and directed by Engineer-in-Charge. |
| 30 | Supply and fixing LED bollard light aluminium extrusion, opal, polycarbonate diffuser for spot and glare free lighting of suitable height not less than 1000mm having IP 65 protection complete 10/15 watt including PCC of suitable ratio for grouting/fixing of light fittings including necessarty excavation and earth work, returning, refilling of excavated soil and making necessary electrical connections with suitable size copper multistranded cable of suitable size but not less than 1.5 sqmm copper multistranded cable and testing after completion upto entire satisfaction of Engr-in-Charge. |
| 31 | Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable)insulated,10 sqmm 2 core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutlistranded, heavy duty 1100 Volts grade complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items). |
| 32 | Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundations etc. or for shafts, well cess pits, manholes, pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing /trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified. |
| 33 | Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubingof 40 to 80 mm bore complete all as specified. |
| 34 | Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified. |
| 35 | Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified. |
| 36 | Material and labour for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed. |
| 37 | M&L laying well burnt old size bricks, sub calss \"B\" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all as specified. |
| 38 | Supplying and fixing (in repairs) Galvanised mild steel tubing, \"Light grade\" of following bore complete with all fittings, laid in trenches/ under roads, drain, paths, fixed to poles/walls with Mild steel clamps, bolts, nuts and washerws complete all as specified of the following bore (Note :- Excavation & Earth work shall be measrued and paid separately) |
| 39 | 40 mm bore |
| 40 | 50 mm bore |
| 41 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn throughrigid PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box/M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate,top sheet cover for housing switches,socket out let and fan regulators etc, all as specified and as directed for the followings:- |
| 42 | Onelight/fan or bell point controlled by oneway switch with 1.5 sqmm copper cable PVC insulated FRLS complete. |
| 43 | Onelight point controlled by two-way switches with 1.5 sqmm copper cable PVC insulated FRLS complete. |
| 44 | One 3 pin 5 Amps socket outlet point controlled by one switch on same board with 1.5 sqmm copper cable PVC insulated FRLS complete. |
| 45 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board with 1.5 sqmm copper cable PVC insulated FRLS complete. |
| 46 | All as item No-39 above but with cable 4 sqmm copper cable PVC insulated FRLS complete. |
| 47 | S&Fswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified. |
| 48 | S&Fswitch Modular type 6 Amps 2 Way,1 module, 230V AC complete all as specified. |
| 49 | S&F Modular socket outlet 2/3 pin 6 Amp socket combined 2 module complete all as specified. |
| 50 | S&F Modular socket outlet 2/3 pin 6A/16 Amp socket combined 2 module complete all as specified. |
| 51 | S&F Modularfan regulator step type 2 module 120W complete all as specified. |
| 52 | S&F bell ding dong AC 230 volt single pole. |
| 53 | S&F bell push modular type 6A single module. |
| 54 | M&L ceiling rose 3 phase polycarbonate isolated body complete. |
| 55 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2000 systems lumen outputwith lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>70, Power Factor > 0.90, THD< 10%, colour temperature-6500K, surge protection 2.5KV in CM, IP-20 protected, Class-1, short circuit and over circuit protection, voltage range-180 to 240 Volts AC, temperature range 0 to 50 degree C andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting completeallas specified and directed. |
| 56 | Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.90, THD<10%, color temperature>6500 K, surge protection 2.5 KV in CM IP-20 protected meets LED IS specifications, voltage range-180 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. |
| 57 | Supply and fixing lamp holder polycarbonated type with back plate suitable for batten fittings. |
| 58 | Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 25,000 burning hours at L70 criteria,Power Factor >0.90, driver with Voltage range 180-270V, Temperature range 0 to 50 Deg, Driver efficiency>85%, THD<10%, CRI>70, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5 sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 59 | Schedule of Credit |