| 1 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft / loose soil all as specified and as directed. |
| 2 | Excavation over areas not exceeding 1.5 mtr deep and getting out in soft / loose soil, etc complete all as specified and directed. |
| 3 | Returning filling in including spreading levelling, watering and well ramming in layers n.exc 25cm thick with useful soil allas specified and directed. |
| 4 | Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point in soil all as specified and directed. |
| 5 | M&L for Moorum/ red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified and as directed. |
| 6 | M&L for hard core with broken stone or boulders of gauge n.exc 63mm, deposited, spread, levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces all as specified and directed. |
| 7 | Excavating in post holes each n exc 0.5 cum, getting out, in soft /loose soil, ramming earth filling or borken rubble mixed with earth around in layers nexc 25 cm watering and removing ssurfaces soil to distance nexc 50 m and making good surfaces all as specified and directed. |
| 8 | Taking down chowkats or frames with shutters not exceeding 1.5 sqm each (without taking off shutters from the frames), complete all as specified and directed. |
| 9 | Taking down chowkats or frames with shutters exceeding 1.5 sqm but not exceeding 4 sqm each (without taking off shutters from the frames). Complete all as specified and directed. |
| 10 | Demolition cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 11 | Demolition reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 12 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. Complete all as specified and directed. |
| 13 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 14 | Dismentling of floor hearth or wall tiling including cement mortar bedding (but not baking ) removing from site.complete all as specified and directed. |
| 15 | brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed. |
| 16 | -ditto- all as per item No. 15 above but except bricks including cleaning of mortar etc; complete all as specified and directed. |
| 17 | M&L for rendering 10mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 on walls finished even and fair, complete all as specified and directed by Engineer-In-Charge. |
| 18 | M&L for 15 mm thick renderingin cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair, etc complete all as specified. |
| 19 | M&L for applying two coats of cement base paint over one coat of primer on plastered surfaces of walls including preparation of new or previously untreated surfaces all as specified and directed |
| 20 | M&L for preparation of plastered surfaces and applying plaster of paris putty of 2mm thick over old and new plaster surface to prepare the surface even and smooth complete all as specified. |
| 21 | M&L for 40mm thick PCC 1:2:4 Type B-1 with 20mm graded stone aggregate as in flooring finished even and rough to receive the topping layer. Complete all as specified and directed. |
| 22 | M&L for cement concrete 1:4:8 type D2(Using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified. |
| 23 | M&L for PCC 1:2:4 type B2 (using 40mm graded agg) as in foundation filling and mass concrete etc complete all as spd and directed. |
| 24 | M&L for 100mm thick plain cement concrete 1:4:8 type D2 using 40 mm graded aggregate as in sub base for flooring allas specified and directed. |
| 25 | M&L for 100mm thick plain cement concrete 1:3:6 type C2 using 40 mm graded aggregate as in sub base for flooring allas specified and directed. |
| 26 | M&L for screed bed or bedding layer of motar 15mm thick for laying floor finish in cement motar 1:6 complete all as specified and directed. |
| 27 | M&L for coloured non skid ceramic tiles 7 to 8 mm thick(square/rectangular) area of each tiles exceeding 0.18sqm but not exceeding 0.38 sqm as in floor etc set and joined in neat cement slurry and pointed in white or coloured cement to match . Complete all as specified and directed by Engr-in Charge. |
| 28 | M&L for HD Digital Glossy finish wall tiles coloured of size 300x600x10 mm thick, jointed in neat cement slurry and poiting in colour cement to match inlcuding 10mm thick plaster in cm 1:4 complete all as specified and directed. Make Kajaria (Cristina Bianca), Nitco (Giza Beige Lt G*), HR Johnson (Tribeca white). |
| 29 | S&F of powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc with a minimum size of 101 x 45 mm to carry laod of Aluminium Door/ windows as fixed complete all as specified and directed. |
| 30 | S&F of powder coated anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified. |
| 31 | S&F of powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinge type B-21 100mm long (2 Nos) suitable handle (1 No.) complete all as specified and directed. |
| 32 | S&F of aluminium diamond grill security window with flyscreens, average width of aperture 75mm, premium quality security window with 20mm frame(thickness) including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittingscomplete all as specified and directed. |
| 33 | S&F of aluminium alloy wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified & directed. |
| 34 | S&F of15mm thick toughened glass as in hinged doors patitions automatic doors and similar work including cutting to shape , drilling holes requried with solar control dil 25micron reflective type socked to glass panes as per instruction of manufacturers complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F of powder coated anodised aluminium frame for doors, windows, ventilators with one or4mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed by Engr-in-Charge. |
| 36 | powder coated anodised aluminium frame for doors, windows, ventilators with one or 8mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately).complete all as specified and directed by Engr-in-Charge. |
| 37 | S&F of powder coated anodised aluminium frame for doors, windows, ventilators with one or powder coated anodised aluminium frame for doors, windows, ventilators with one orGl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. complete all as specified and directed by Engr-in-Charge. |
| 38 | S&F of steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified. |
| 39 | S&F of 5 mm thick mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 290 grade E-165 complete all as specified. |
| 40 | S&F of mild steel screw bolts (machine made) of 11 mm to 15 mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt exceeding 10 cm but not exceeding 15 cm complete all as specified. |
| 41 | S&F of pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified. |
| 42 | M&L for preparation of new steel surfaces of any descriptionexc 10 cm width or girth when unconnected with other Painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat ofred oxide primer all as specified and directed. |
| 43 | M&L for RCC (nominal mix) type B1 1:2:4 (20mm graded aggregate ) as in slabs supported on wall beam and columns in floor roofs landings balconies canopies deck slabs and in shelves and the like, complete all as specified and directed by Engr-in-Charge. |
| 44 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engr-in-Charge. |
| 45 | M&L for granite 20mm thickmachine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types including 15mm thick bedding layer in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 46 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and directed by Engr-in-Charge. |
| 47 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to. Complete all as specified and directed by Engineer-In-Charge. |
| 48 | S&F of vitreous china wash hand basin counter type, coloured and size not less than 630 x 450mm including waste pipe and coupling with a pair of CI brackets reqd for fixing, complete all as specified and directed. |
| 49 | S&F of vitreous china urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) with grating and union for dischage pipe complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement fixing flush pipe grating and union for discharge pipe complete fixed in repairs. complete all as specified and as directed. |
| 50 | S&F of urinal spreader of PTMT any colour for fixing with 15mm dia pipe (min weight 60gms).. complete all as specified and as directed. |
| 51 | S&F of coupled closet (one peace) EWC colour, bowl for coupled EWC with UF soft close slim seat cover, Hinges, fixing accessories and accessories set size 380x660x765mm and cistern withcistern fittings complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F of SDG frameless bevelled mirror for bathrooms Wall and Office, 18x24 Inch (Silver) and 5mm thick looking mirror and bevelled Edge of mirror for 0.75 Inch, Edge thickness shall be 4mm, fitted to wooden plug with CP screws complete all as specified and as directed by Engr-in-charge. |
| 53 | S&F of toilet paper holder with flat recessed type stainless steel , chromium plated fixed with brass screws complete all as specified and as directed. |
| 54 | S&F of health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 55 | S&F of sheet glass shelf PTMT assembly consisting of 5.5mm thick sheet glass shelf 12cm wide fixedwith includingchromium plated screw, bracket guard and railing 60cm long complete all as specified and directed. |
| 56 | S&F of stainless steel soap dispensers with bracket complete all as specifiedand directed. |
| 57 | S&F of tubular towel rail brass chromium plated, D type, 60cm long between flange complete all as specified and directed. |
| 58 | S&F of 32mm waste coupling of PTMT (half or full threaded) (minimum weight 40mm-60 gms) with PVC waste pipe for wash hand basin fixed in repair complete all as specified and as directed. |
| 59 | M&L for chromium plated long body bib tap cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe and fix to 15mm bore pipe fix as .complete all as specified and as directed. |
| 60 | S&F of 15mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 61 | S&F of 15mm bore pillar taps, cast copper alloy with capstan heads chromium plated fancy type screwed down high pressure with or without lettered hot or cold with long screwed shank and fly nuts, .complete all as specified and as directed. |
| 62 | S&F of 100mm size stainless steel butt hinge medium weight complete all as specified and directed by Engr-in-Charge. |
| 63 | S&F of aluminium handle cast type anodised of size 125mm etc complete all as specified and directed. |
| 64 | S&F of 150mm long aluminium alloy anodized barrel tower bolt of extruted section and fix Complete all as specified and directed by Engr-In Charge. |
| 65 | S&F of PVC connection 15mm size with PTMT nut of length 450mm etc Complete all as specified and directed by Engr-In Charge. |
| 66 | S&F of PVC connection 15mm size with PTMT nuts of length 300mm complete all as specified and directed. |
| 67 | S&F of stop valve/ angle valve cast copper alloy bore dia of pipe 15mm screwed down high pressure with crutch or but trely handle screwed both ends for iron pipe and fixed but fancy type brass chromium plated Complete all as specified and directed by Engr-In Charge. |
| 68 | S&F of stop valve/ angle valve cast copper alloy bore dia of pipe 15mm screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe and fixed but fancy type brass chromium plated with long shank and cup (concealed type) etc complete all as specified and directed by Engr-in-Charge. |
| 69 | S&F of shower rose of brass chromium plated with shower arm 195mm long with bend of 45 degree 15mm dia, complete all as specified and directed by Engr-in-Charge. |
| 70 | Taking up or down, steel tubing 15mm bore and connections including cleaning for refixing and removal from sitecomplete all as specified and as directed. |
| 71 | Taking up or down, steel tubing 20mm bore and connections including cleaning for refixing and removal from sitecomplete all as specified and as directed. |
| 72 | S&F of32mm dia of CPVC PipesSDR 11 &Plain CPVC SDR 11 fitting on walls/celling or laying in floor complete all as specified |
| 73 | S&F of20 mm dia of CPVC PipesSDR 11 &Plain CPVC SDR 11 fitting on walls/celling or laying in floor complete all as specified |
| 74 | S&F of CPVC elbow 32mm bore complete all as specifed and directed by Engr-in-Charge. |
| 75 | S&F of CPVC elbow 20mm bore complete all as specifed and directed by Engr-in-Charge. |
| 76 | Cutting holes into or through brick walls superfacial area n.exc. 150 sqcmbult incement mortar or cement lime mortar and making good in c.m 1:3 or cement concrete 1:2:4 type B-1including matching the surfaces with the existing surface finishes complete all as specified and directed by Engr-in-charge. |
| 77 | S&F of 110mm bore PVC (SWR) pipe single socket in any length with rubber ring joint laid in trenches or in floor Complete all as specified and directed by Engr-In Charge. |
| 78 | S&F of 110mm bore PVC (SWR) bend any radius Complete all as specified and directed by Engr-In Charge. |
| 79 | S&F of PVC (SWR) floor trap of 110 mm outlet dia plain with grating including jointing with solvent cement Complete all as specified and directed by Engr-In Charge. |
| 80 | S&F of CP garting 100mm dia with waste hole ofetc complete all as specified and directed. Complete all as specified and directed by Engineer-In-Charge. |
| 81 | S&F PVC (SWR) vent cowl of 110mm bore complete all as specified and directed by Engr-in-Charge. |
| 82 | S&F 110mm PVC (SWR) junction (single T) equal or unequal Complete all as specified and directed by Engr-In Charge. |
| 83 | S&F of 75mm bore PVC (SWR) pipe single socket in any length with rubber ring joint laid in trenches or in floor Complete all as specified and directed by Engr-In Charge. |
| 84 | S&F of PVC (SWR) Bends and radius of 75mm bore complete all as specified and directed by Engr-in-Charge. |
| 85 | S&F of PVC (SWR) junction single, (Single T) equal or unequal of 75m bore complete all as specified and directed by Engr-in-Charge. |
| 86 | S&F of PVC (SWR) 75mm floor trap, plain with grating, including jointing with cement solvent complete all as specified and directed by Engr-in-Charge. |
| 87 | S&F of rotational moulded polyethylene water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified including 20mm dia ball brass valve, complete all as specified and directed by Engineer-In-Charge. |
| 88 | S&F of 20mm brass ball valves, high pressure with polythene float and flynut complete all as specified and directed by Engr-in-Charge. |
| 89 | S&F of gun metal ,globe or gate metal with iron wheel head screwed both ends for iron pipe and fixed to steel or union 20 mm bore dia of pipe.Complete all as specified and directed by Engr-In Charge. |
| 90 | Taking down carefully aluminium / copper point wiring (light, fan, socket, powerpoint) including batten, conduit and fittings such as switches, ceiling rose, sockets, brackets, light fittings, switch board etc, making good distrubed surfaces of wall, floar, ceiling etc complete all as specified and directed. |
| 91 | M&L for point wiring for one light / fan / bell point with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor ( FRLS ) 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including PVC concealed conduit with all accessories including 1.5 sqmm copper multistrand conductor (FRLS ) 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel Metal flush mounting box for mounting of fittings like switch , socket and fan regulator and cover plat of suitable modules capacity and make of swich socket complete all as specified and as directed. |
| 92 | One light point controlled by one, one way switch |
| 93 | One fan point controlled by one, one way switch |
| 94 | One socket outlet 3 Pin, 5 Amp on independent board |
| 95 | One socket outlet 3 Pin, 5 Amp on same board. |
| 96 | - ditto - all as per item No. 91 here in before but 2.5 Sqmm PVC insulated unsheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board. |
| 97 | All as per item No. 91 here in before but 4 Sqmm P.V.C insulated unsheathed cable with stranded copper conductor for 6 pin 6/16 Amp switch socket combination on independent board. |
| 98 | S&Fswitch piano flush type single pole one way 6 Amp (ISI Marked) |
| 99 | S&F switch piano flush type single pole one way 15 Amp (ISI Marked) |
| 100 | S&F socket out let 2 in 1, 3 pin 5 Ampflush type (ISI Marked) |
| 101 | S&F socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) |
| 102 | M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) |
| 103 | S&F in repairPVC/Polycarbonate Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings type with back plate suitable for batten fittingscomplete all as specified and as directed. |
| 104 | Supply, installation, testing and commissioning of 40 watt 4 ft long LED Batten housing made of extruded alluminium with milky white diffuser and inbuilt electronic driver system lumen output should be at least 1800 lumen with a CCT of 6000 K, power factor should be greater than 0.9 with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed. |
| 105 | Taking down old US MCB DB and S & F in Repair sheet metal enclosure for MCB DB double door single pole & Neutral 12 way with 200 Amps rated bus bar all as specified and directed by Engineer-in-Charge. |
| 106 | Taking down old unsv MCB and Supply and fixingSP 6 To 32 AMP amp rating 240V, 10KA \"C\" curve miniature circuit breaker(MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified. |
| 107 | - ditto - all as per item No. 102 here in before but SPN 32 AMPcomplete all as specified. |
| 108 | Supply and fix wall mounted fan PVC body AC single Phase. 230V of size 400m sweep with three blades, complete all as directed by Engr-in-Charge. |
| 109 | Supply Installation. testing and commissioning Solar Water Heater (Flat plate collectortype), capacity 200 LPD duly integrated with electric water heater, indirect Heating with Heat exchanger SS 304 with selectively coated \"B size Solar Flat Plate Collector (cu-Cu), made of aluminium body with toughened glass of thickness 3.2mm insulated hot water tank including inter connection circulation piping between the system, collectors and hot water tank stand & temp gauge etc.2 nos. of Solar Collectors for 200 LPD for installation of Solar water heater with the following specification as per IS 12933 (Part-1)-2003(a) Solar Flat plate collector ISI Marked dimension (2030mm*1030mm ±10mm) (cu-cu)(b) Material-aluminium casttype channel and angle.(c) Back covering 24 SWG aluminum sheet and upper covering not less than 3.2mm thick temper/toughened glass absorber selectively coated copper fin and tubes nominal fins, insulation 50mm thick mineral wool of 48 kg/cum density & reffector, 48 gauge aluminium foil(d) Gasket EPDM/SPDMNeoprene flange(e) electric backup as per manufacturers recommendations(f) Solar Hot Water Tank capacity 200 Ltr made of 1 mm SS 304 with 50mm puffinsulation including neccessary structure and finishing work, foundations Electrical connection and othe safety devices such as thermostat relay etc complete all as specified and directed byEngr-in-Charge. Make-Inter Solar, Bosch, Solimpeks, TATA BP, Novel Energy |
| 110 | Supply and fix rotational moulded poly ethylene water storage tanks Capacity 500 liter( Cylindrical vertical With Close Top ) Hoisted and Fixed in Position all as Specified in SSR part-1. |
| 111 | Supply and fix 32mm bore PP-R polypropylene random copo-lymer) concealed Pipes SDR 7.4 ( PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain & Brass threated polypropylene random fittings laid in trenches. |
| 112 | - ditto - all as per above ser item no. 107but size 25mm bore. |
| 113 | - ditto - all as per above ser item no. 107but size 15mm bore. |
| 114 | Suply and fix staging/foundation for water tank made out of ms angle , Strip etc complete all as specified and directed . |
| 115 | Taking down GI pipe 25 mm bore medium grade and fitting and supply and fixing GI tubing medium grade 25 mm bore in any length with all fitting laid in trench and connecting up with water supply main complete all as specified and directed (Excavation and earthwork shall be measured and paid for separetely under approprite item) by Engr-in-Charge. |
| 116 | Supply and fix exhaust fan, made of sturdy engineering plastic AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers cutting of the holes in existing wall and making good the surfaces all as directed. |
| 117 | M&L for GI Pipe \"light grade\" galvanized with all fitting laid in trenches/on pole/road crossing of size 40mm |
| 118 | Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 25 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole including taking down old one complete all as specified and directed by Engr-in-Charge. |
| 119 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation of poles/ stays/ laying of cables etc and gettingout including trimming of sides of trenches complete all as specifiedand directed. |
| 120 | Returning, filling the soft / loose soil including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and directed. |
| 121 | Removing of surplus excavated soilto a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point completeall as specified and directed. |
| 122 | M&L for sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed. |
| 123 | M&L for brick protection using old size sub class ‘B’bricks, laid flat, dry adjacent to each otherlaid length wiseperpendicular to theaxis of cable complete all as specified and directed. |
| 124 | Earthing complete with galvanised steel earth plate electrode 60×60cm.x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |