| 1 | Demolition of cement concrete in ground floor and pavings n exc 15cm thickness (below or above ground level) complete all as directed. |
| 2 | M& L for rubber moulded Chequered cement concrete colourtiles 30 cm x 30 cm x 25mm thick with mixture of grey cement & pigment set jointed and pointed in neat cement slurry in floors including 15mm thick screed bed inC M 1:6 complete all as specified and as directed. |
| 3 | M & L Machine pressed precast concrete rubber moulded interlocking dark colouredpaver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 Grade all as specified and disposing to debries etc all as directed by Engr-in-Charge. |
| 4 | M&L sand filling under floors or in foundation including watering and consolidation |
| 5 | M&L Cement concrete ( 1:2:4) type B-1, using (20mm graded stone aggregate)25 mm thick as in sub base complete all as directed. |
| 6 | M & L Cement concrete1:4:8 in foundations, filling and mass concreteas in sub base all as specified. |
| 7 | S&F in repairs pre painted galvalume aluminum ZINC coating GI base corrugated steel 0.5mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall fixed with self tapping screw with minimum 150mm end lap and one corrugation side lap including dismantling the existing sheets complete all as specified and directed. |
| 8 | S&F properly on wall of display board of size minimum 1 sqm of coloured acrylic sheet of minimum 8mm thickness sheet to show house number occupant (Offrs) name, display board will show house number in 3 digit & words like Ground, 1st floor to 5th floor on board, size of word should be either 25mmx15mm or instructed by Engr-in-Charge, with fixing/detachable arrangements.This item includes dismantling/removal of old board complete all as specified and directed. |
| 9 | Demolition of brick work built in cement mortar in any description and position,complete all as specified. |
| 10 | Excavation in trenches (soft/loose soil) n exc. 1.5m wide and n exc 1.5 m in depth for foundation etc. and getting out all as specified. |
| 11 | M & L Cement concretetype D-2, 1:4:8 (40 mm graded stone aggregate) in foundations, filling and mass concreteas in sub base all as specified. |
| 12 | M&L for brick work with sub class \"B\" brick straight or curved on plan exc6 metre mean radius with old size bricks, built in cement mortar 1:4, complete all as specified. |
| 13 | M&L for brick work with subclass \"B\" bricks, straight or curved on plan to any radius in half brick thick walls with old size bricks, built in cement mortar1:4, complete all as specified. |
| 14 | All as per item no 9 before but except bricks |
| 15 | M&Lcement concrete 1:3:6 type C2 using 40mm graded aggregate in surface channels and drains etc incl demolition of existing drain, surface channel all as specified and disposing of debries etc as directed by Engr-in-Charge. |
| 16 | M&Lcement concrete 1:2:4 type B2 using 20mm graded aggregate in drains, foundation,coping, flooring etc all as specified and directed by Engr-in-Charge. |
| 17 | Taking down cement plaster in concrete or brick wall suface of any thickness from brick or stone walls etc including raking out joints, hacking for key,scrubbing down with wate etc complete all as specified. |
| 18 | M&L for rendering 15mm thickon fair faces of brick work or concrete surfaces in CM 1 : 4 mixedfinished even and fair faces using extra cement complete all as specified. |
| 19 | M&L preparation of newly plastered surfaces of work and applying two coats of cement base paint complete all as specified and directed. |
| 20 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 21 | M & L for removing excavated material exc. 250m but not exceeding 500m and depositing where directed all as specified. |
| 22 | M&L for cement concrete 1:2:4 type B1(using20mm graded stone aggregate) as in blocks for hold fast, coping,benching etc. including weathering, slightly rounded or chamfered angles or throating including form work to concrete surfaces, complete allas specified |
| 23 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified. |
| 24 | Dismantlingpost or struts (wood , steel or RCC) of any sectionany description and in any position including taking out embedded portion in concrete, brick work, masonry etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed |
| 25 | Dismantling fencing wire mesh any type fixed in any situation complete all as directed. |
| 26 | Excavating in posts holes (or similar holes) in soft/loose soil each n.exc 0.50 Cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm complete all as specified and directed. |
| 27 | S&Fin repairs Framed work as in Fencing Posts, Swan necks, doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing offencing wireor other covering.etc.also fastening and fixing completeincl cleats, brackets, complete of Fe 410-W (Gde e-250) quality B complete all as specified and directed. |
| 28 | M/L for providing PCC (1:3:6) type C2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed. |
| 29 | Fixing only chain link fencing including line wires, any mesh, size and type to any of standards, rails, straining bolts, etc including provision of binding wire complete all as directed. |
| 30 | Supply only Chain link MS galvanised fencing any size or type complete all as directed. |
| 31 | S&F Mild Steel round bars in fencing etc complete all as specified and as directed. |
| 32 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed to other, or screwed both ends, each screwed end to be fitted with washers and hexagonal or square nut length of boltn.exc 5cm long and dia of neck 5 to 10mm complete all as specified and directed. |
| 33 | Preparation newly or previously untreated steel surfaces of any description over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of red oxide complete all as directed |
| 34 | S & Ffor precastplastic fibre reinforced cement concretedrain coverincluding drain hole, grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mm & 75 mm thick complete all as specifiedand as directed. |
| 35 | M&L for cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection 75mm thick laid in bays and surfaces finished even and fair, including filling the joints with bitumen mastic complete all as specified and directed. |
| 36 | M&L for steel work in tubular trusses inclung special shaped washersetc omplete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade including dismantling of old steel work complete all as directed by Engr-in-charge. |
| 37 | M&l for dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 38 | Providing and fixing factory made 18 mm thick 100% Solid WPC (Wood Polymer Composit) JALI, of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibrs (wood powder/rice husk/ wheat husk) and non toxic additives made from Extrution Process WPC foam sheet Single Extruded (Inner) with having minimun density not less than 650 kg/cum manufactured by certified company having good screw holding capacity (Screw Withdrawl strength of 2000 N (Face) & 1100 N (Edge), minimum compressive strength 50 N/mm2 and resistance to spread of flame of class A category with properties of being termite/borer proof, water/moisture proof and fire retardant. WPC Jali to fixed with stainless steel butt hinges (if required) of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer-in- Charge, material test certificate and authentication should be compulsory provided by the manufacturer company. |
| 39 | Providing & Fixing factory made 100% Solid WPC ( Wood Polymer Composite ) Door Frame 75mm x 50 mm ( Moulded ) Single Rebated, made from Wood Polymer Composite ( Single Extruded Process ) material comprising of virgin PVC polymer of K Value 57-60 (suspension Grade ), Calcium Carbonate and Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/cum & manufactured by Certified Company, having good screw holding capacity ( Screw Withdrawal strength of ( Min.990 N ), Minimum Compressive Strength of 58 Nlmm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite I borer proof , water / Moisture proof & Fire retardant &. Fixed in position with SS Dash Fasteners / Hold Fast of required dia and lenght, all as per specifications drawings as directed by the EngineerJn-Charge, Material test ceftificate and authentication should be compulsory provided by the manufacturing company. |
| 40 | M & L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4(1 cement: 4 coarse sand) furrowing the under layer with scratching tool and applying cement slurry on the under layer @3g of cement per square metre, top layer 15mm cement plaster 1:1/2:2(1 cement :1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and wasshing, the top layer with brushes and water to expose the stone chippings complete all as specified(Payment for providing grooves shall be made separately). |
| 41 | M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of penels and finishing the groove complete as per specifications and direction of Engineer-in- Charge. |
| 42 | M&L Endura colours paving tiles of size 30cm x 30cm x 10mm thick double charged digital printed with gloss, polished matt finished, set, jointed and pointed in neat cement slurry laid over 15mm thick screed bed in cm 1:6 as in floors with no pigment complete all as specified and directed |
| 43 | S&F SFRC manhole covers of medium duty of overall size 1000mmx500mmx75mm thick factory made complete all as specified and directed. |
| 44 | S & F for precast plastic fibre reinforced cement concrete Manhole covers with frame medium duty of overall size 450mmx450mm & 50mm thick factory made (make-polycrete) all as specified and directed by Engr-in-Charge. |
| 45 | Schedule of Credit |