| 1 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 2 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 3 | S&F 9 mm thick prelaminated particle board interior grade, ISI marked, both side with decorative choice lamination fixed to aluminium door/partition complete all as specified and directed. |
| 4 | S&F 4.8 mm thick sheet glass, ordinary quality and glazing with oil putty /wooden beads in square n. exc 0.5 sqm in each pane complete all as specified and as directed. |
| 5 | S&F 150 mm long extruded Aluminum alloy handles, fabricated type, anodizedcomplete all as specified and directed. |
| 6 | S&F 200 mm long aluminium anodized barrel tower bolts of extruded sections and fixed complete all as specified and as directed. |
| 7 | S&F aluminium extruded section body door closer hydraulically regulated, designation No -3, universal type, suitable for door shutter of 851 to 1000 mm in width and of weight 61 to 80 Kg (ISI marked) complete all as specifiedand as directed. |
| 8 | S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed. |
| 9 | S&F Brass 4 levers mortice lock, vertical type of size 100 mm complete all as specified and directed. |
| 10 | M&L for PCC 1:2:4 type B-2, using 40 mm graded stone aggregate as in foundation and mass concrete complete all as specified and directed. |
| 11 | S&F angle iron or any section of any size for balusters, nosing to steps including embeding in concrete and screwing etc., posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 12 | S&F for 3.15 mm dia, expended, welded, mild stee wire fabric of mesh, size25 mm x 25 mm, weight not exc 4 kg per Sqm, including cutting in any size, fixed to steel member such as angle/flat with welding complete all specified and directed. |
| 13 | M&L for preparation of new steel surface and applying two coats ofsynthetic enamel paint over and including a coat of red oxide and zinc chrome primer onsteel surfaces of any description, over 10 cm width or girth complete all as specified and directed. |
| 14 | Supply, installation and testing of inverter type split unit Air conditioners electric driven single phase of capacity 2.0 Ton, 5 star BEE rating,copper condenser, indoor noise level <50db with standard fitment and accessories complete all as specified and directed. |
| 15 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB of Capacity 20 Amps complete all as specified and as directed. |
| 16 | M&L for cutting holes into through brick walls built in cement mortar and making good in cement mortar (1:3) or PCC (1:2:4) type B1 to match with existing surfacesuperficial area exc 150sqcm but not exc 400 sqcm complete all as specified and as directed. |
| 17 | S&F copper tube kit (all in one) (7 mtr length) of size 1/4 inch and 1/2 inch with fire retardant insulation layer, flexible drain pipe & interconnecting copper cable complete all as specified and directed. |
| 18 | S&F floor mounted outdoor bracket of length 24 inch, P2 type, heavy duty, load capacity upto 50 kg, compatible for all AC outdoors upto 2 Ton complete all as specified and directed. |
| 19 | M&L for sub main wiring complete with (2x4.0 Sqmm+1x2.5 Sqmm earth wire) 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi strandedduly colour coded cable drawn through and including PVC casing Caping and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 2.5 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. Note : -02 run of 4 sqmm single core copper conductor cable and 01 run of 2.5 sqmm single core copper conductor and 01 run of PVC Casing Capingshall be measured as one unit. |
| 20 | M&L for sub main wiring complete with (2x10.0 Sqmm+1x6.0 Sqmm earth wire) 2 run of 10 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi strandedduly colour coded cable drawn through and including PVC casing Caping and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. Note : -02 run of 10 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC Casing Capingshall be measured as one unit. |
| 21 | M&L for LT under ground cable 10 Sqmm 2 Core, 1100 V grade XLPE insulated screenedPVC bedded , galvanized steel strip or wire armoured, electric power cable with stranded aluminium conductors laid in pipes,trenches, clamp on wall etc complete all as specified and directed. |
| 22 | Excavation in trenches not exc 1.5 mtrs wide & not exc 1.5 mtrs in depth for taking out/laying of pipes/cables etc & getting out in Soft/Loose soilcomplete all as specified and directed . |
| 23 | Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtrs above the starting pointcomplete all as specified and directed . |
| 24 | Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 25 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cables of size.Outer/Inner dia of pipe 40/32 mmwith all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified(excavation and earth work shall be measured and paid separately). Rate for Inserting cable in pipe deemed to be included in quoted rate. |