| 1 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in ground floors and paving, not exceeding 15 cm thickness (below or above ground level), complete all as directed. |
| 2 | Dismantling of single layer Mangalore pattern or similar tiles in roofing, complete all as specified and directed. |
| 3 | M&L for roof tiles, Mangalore pattern Class \"AA\", interlocking at side joints, laid dry, complete all as specified and directed. |
| 4 | All as per Sr Item No. 03 above, but excluding tiles, complete all as specified and directed. |
| 5 | M&L for cement concretet 1:2:4 type B-0 using 12.5mm graded stone aggregate as in roof kerbs/paddings/mud-stops or bedding for water tanks/tiles etc., including chamfered edges, complete all as specified and directed. |
| 6 | S&F in repairs rotational moulded polythene water storage tank, triple‑layered, dust‑proof, ISI marked, cylindrical vertical with closed top, hoisted and fixed in position, capacity 1000 litres, including all the necessary fittings & fixtures to connect with existing pipeline complete all as specified and directed. |
| 7 | Supplying and fixing in repairs 25 mm bore brass float valve, high pressure, with polythene float and fly nut complete, screwed for GI pipe of following sizes, including necessary GI fittings, complete all as specified and directed. |
| 8 | S&F in repairs 15 mm dia gun-metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed in repair, complete all as specified and as directed. |
| 9 | Taking up or down GI tubing and connections 15 mm bore, including cleaning and stacking/removal to store, complete all as specified and directed. |
| 10 | S&F 15 mm dia uPVC pipes of pressure rating 10 kgf/cm², fixed to walls, ceiling or in floors etc., complete all as specified and directed. |
| 11 | Taking up or down GI tubing and connections 32 mm bore, including cleaning and stacking/removal to store, complete all as specified and directed. |
| 12 | S&F 32 mm dia uPVC pipes of pressure rating 10 kgf/cm², fixed to walls, ceiling or in floors etc., complete all as specified and directed. |
| 13 | S&F in repairs 32 mm dia gun-metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed in repair, complete all as specified and as directed. |
| 14 | Dismantling of stone/boulder masonry built in cement mortar, including all quoins, arches, pillars etc., but excluding ashlar facings and dressed stonework etc., complete all as specified and directed. |
| 15 | M&L for providing precast cement concrete block masonry with solid blocks, exceeding 10 cm width,(1:3:6 type C-1 using 20mm graded stone aggregate) and set in cement mortar 1:4, complete all as specified and directed. |
| 16 | Taking down cement plaster on brick or concrete surfaces of wall/ceiling and the like, including racking out joints, hacking for keys, scrubbing down with water etc., of any description, including removal of rubbish outside MoD land, complete all as specified and directed.Note: The rate quoted by the Contractor shall be deemed to include necessary scaffolding and formwork. |
| 17 | M&L for rendering 15 mm thick in CM 1:4 on fair faces of concrete surfaces and finishing even and smooth without using extra cement, including necessary scaffolding and safety measures as required, complete all as specified and directed. |
| 18 | M&L for preparation of new plastered/decorated wall surfaces and applying two coats of acrylic emulsion exterior grade paint over a coat of primer, including necessary scaffolding and safety measures as required etc., complete all as specified and as directed. |
| 19 | M&L for providing 15 mm thick rendering over roof slab in cement mortar 1:3 mixed with waterproofing compound @ 1% (or as per manufacturer’s instructions, whichever is higher) by weight of cement, finished even and smooth without using extra cement, complete all as specified and directed. |
| 20 | M&L for waterproofing treatment by applying oil bound bitumen primer having density 0.87–0.89 kg/litre @ 0.40 litre/sqm, providing and laying APP modified waterproofing membrane weighing not less than 3.50 kg/sqm of approved make, including minimum 10 cm side lap and 15 cm end lap, laid and pasted with blue flame torching application, and finally finishing with two coats of solar reflective bituminous aluminium paint @ 0.1 kg/sqm, complete all as specified and directed. |
| 21 | M&L for PVC (SWR) pipe, single socketed in any length with rubber ring joints, fixed to wall, 110 mm bore etc., complete all as specified and directed. |
| 22 | S&F PVC (SWR) 100 mm branch piece, single (single Y), equal or unequal, complete all as specified and directed. |