| 1 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing),removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.. |
| 2 | Dismantling Stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness infloors, aprons etc. complete all as specified and directed. |
| 3 | M&L for 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and directed. |
| 4 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 to receive tiles etc on vertical surfaces of walls complete all as specified and directed. |
| 5 | M&L for light shadeVitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 SQM, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match premium quality as in floor etc. complete all as specified and directed. |
| 6 | All as per item No 5 here in before but on vertical surfaces/skirting complete all as specified and directed. |
| 7 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular)area of each tile exceeding 0.06 SQM but not exceeding 0.11 SQM, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 8 | M&L for Glazed ceramic coloured tiles in vertical surfaces 300X450X7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 9 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 SQM but not exceeding 0.18 SQM, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 10 | M&L for Granite 20 mm thick (of any type) work (table rubbed and polished) insteps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 11 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 12 | Dismantling Plain or corrugated steel/ Fibre translucent sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 13 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 14 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 15 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 16 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. (Fe 410-W(Gde-E- 250) quality-A) complete all as specified and directed. |
| 17 | S&F 2mm thick fibre glass reinforced translucent corrugated/plainsheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etccomplete all as specified and directed. |
| 18 | S&F pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of colour having tensile strength of 550Mpa as in roof covering fixed with self tapping screw complete all as specified and directed. |
| 19 | M&L Loose filling with aggregates with broken stone or boulders of gauge 80 to 150 mm in soakage pits, soakage wells and Recharge pits etc complete all as specified and directed. |
| 20 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar complete all as specified and directed. |
| 21 | M&L Brick work with fly ash brick, old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed |
| 22 | Taking down cement or cement lime plaster any description incl racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 23 | M&L for cement plaster 10mm thick plaster in CM 1:6 on fair faces of brick work or concrete surfaces of walls finished even & smooth with out using extra cement complete all as specified and directed. |
| 24 | M&L for cement plaster 15 mm thick plaster in two layer (first layer 10mm thick & Second layer 5mm thick) in CM 1:4 on fair faces of brick work or concrete surfaces of walls finished even & smooth with out using extra cement complete all as specified and directed. |
| 25 | M&L for 10mm thick cement plaster in CM 1:3 as in ceiling finished even and smooth without using extra cement over 10mm thick setting coat using bonding agent as directed. |
| 26 | M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 27 | M&L for preparation of new wood surfacesof any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 28 | M&L preparing newsurface of wall and applying three coat of white washcomplete all as specified and directed. |
| 29 | M & L preparing newsurface of ceiling and applying two coat ofoil emulsion distemper over a coat of chalk whiting complete all as specified and directed. |
| 30 | M & L preparing newsurface of wall and applying two coat ofcement base paint over a coat of chalk whiting complete all as specified and directed. |
| 31 | M&L for preparation of newly plastered surface of wall and appplyingTwo or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. all as specified and directed |
| 32 | M&L Loose filling with aggregates with broken stone or boulders of gauge 40mm to 80 mm in soakage pits, soakage wells and Recharge pits etcas specified and directed. |
| 33 | M&L for preparation of oldsurfaces of ceiling and applying one coat of white wash complete all as specified and directed. |
| 34 | M&L for preparation of oldsurfaces of wall and applying one coat of white wash complete all as specified and directed. |
| 35 | M&L for preparing of oldsurfaces of ceilingand applying one coat of distemper oil emulsion complete all as specified and directed. |
| 36 | M&L for preparing of old surfaces of wallsand applying one coat of distemper oil emulsion complete all as specified and directed. |
| 37 | M&L for preparing of oldsurfaces of walls and applying one coat of cement based paint complete all as specified and directed. |
| 38 | M&L for preparing of old surfaces of wall and applying onecoat of acrylic weather coat paint complete all as specified and directed. |
| 39 | M&L for preparation of old wood surfacesof any description, not otherwise descri-bed, over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 40 | M&L for preparation of old painted steel and iron surfacesof any descriptionover 10cm width or girth not otherwise described and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 41 | S&F 12mm Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required with all fittings and solar control film 50 micron reflective type sticked to glass panes as per manufacture instruction complete all as specified and directed. |
| 42 | Disconnecting existing tanks, setting aside (or lowering if required) of capacity exc 250 Ltr n exc 500ltr for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. (Cleaning repairing, etc. measured separately) |
| 43 | Disconnecting existing tanks, setting aside (or lowering if required) of capacity exc 500 Ltr n exc 1000ltr for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.. (Cleaning repairing, etc. measured separately) |
| 44 | M&L Loose filling with aggregates with broken stone or boulders of gauge upto 25 mm in soakage pits, soakage wells and Recharge pits etcas specified and directed. |
| 45 | S&F in repairs 10 litres capacityPVC valveless symphonic action type, flushing cistern, low level, white, with inlet, ball valve float handle including brackets complete all as specified and directed. |
| 46 | S&F in repair 32mm brass chromium plated waste coupling for wash hand basin complete all as specified and directed. |
| 47 | S&F in repairs Pillar taps, fancy type cast copper alloy, with capstan heads, chromium platedscrewed down highpressure, with orwithout lettered \"Hot\" or \"Cold\" withlong screwedshanks and fly-nuts,screwed for iron pipe and fixed to 15mm bore pipecomplete all as specified and directed.. (Minimum weight0.665 Kg). |
| 48 | S & F in repairs Bib taps fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed to 15mm bore pipe complete all as specified and directed..(Minimum weight0.575 Kg). |
| 49 | S&F in repairs Stop valves fancy type cast copper alloy,screwed down,high pressure,with crutch orbutterfly handle,screwed bothends for iron pipe or fo runions and fixed to15mm bore pipe complete all as specified complete all as specified and directed. (Minimum weight0.575 Kg). |
| 50 | S & F in repairs Toilet paper holder with flat recessedtype stainless steel Complete all as specified and directed. |
| 51 | Supply and fix in repairs 32 mm size waste pipe for wash hand basin / urinal / sink complete all as specified and directed. |
| 52 | M&L coarse Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 53 | S&F 5.50 mm thick glass,looking mirror size exc 0.5 Sqmandnot exc 3 Sqm of selected quality glass, mounted on 10 mm thick commercial ply woodwith chromium plated brass screws/ Bracketsincluding taking down old looking mirror complete all as specified and directed. |
| 54 | S&F in repair Stainless steelsinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 55 | S & F in repairs stainless steel Soap dish fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 56 | Demolition Cement concrete(unreinforced) Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 57 | M&L for 75mm thick Cement concrete Type D21:4:8 (40 mm graded gradedaggregate) as in floor finishes and pavings complete all as specified and directed. |
| 58 | M&L for 20 mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes all as specified and directed. |
| 59 | M & L Chequred cement concrete tiles 30cm x30cmx 25mm thick with grey cement and pigment , set jointed in neat cement slurry complete all as specified as directed. |
| 60 | Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 61 | Dismantlingof stone slabs and paver block tiles of any description or thickness in floorslaid bedded and pointed in any mortar complete all as specified and directed. |
| 62 | M&L Sand filling under floors or in foundations including watering and consolidation all as specified and directed. |
| 63 | M&L for machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment conforming to IS-15658-2006 of 60mm thickness M-35 gradecomplete all as specified and directed. |
| 64 | All as per item No 63 here in before but except tiles complete all as specified and directed. |
| 65 | M&L for machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment conforming to IS-15658-2006 of 80mm thickness M-40 gradecomplete all as specified and directed. |
| 66 | All as per item No 65 here in before but except tiles complete all as specified and directed. |
| 67 | M& L factory made kerb stone of concrete C2 1:3:6 (25mm graded aggregate)cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever omplete all as specified and as directed. |
| 68 | M&L for preparation of old painted surfaces of wall / concrete surfacesover 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified. |
| 69 | M&L for preparation of new surfaces of wall / concrete surfacesover 10cm width or girth not otherwise described and applying two coats of synthetic enamel paintover a coat of primer complete all as specified. |
| 70 | Demolition of Cement Concrete(Reinforced) of any description and in any position not otherwise specifically provided for compete all as specified and directed. |
| 71 | M & L for precast cement concrete 1:2:4 Type B1 using 20 mm graded aggregate for manhole covers/ drai covers all as specified and as directed. |
| 72 | M & L for TMT bars 6 to 8 mm dia and above cut to length, bent to shape required, including crancking, bending spirelly for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and as directed. |
| 73 | S&F in repairs PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls forrain water pipes complete all as specified and directed. |
| 74 | S&F in repairs PVC (SWR) bends any radius 110mm dia complete all as specified and directed. |
| 75 | S & F in repair PVC connection 15 mm size with PTMT nuts on both end, length 450 mm, including taking down old PVC connection complete all as specified and directed. |
| 76 | S & F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with MS screw & bolts in repairs complete all as specified and directed. |
| 77 | S & F in repair 300 mmsize mild steel ordinary rat tail, rod pattern springs including roller and roller plate complete all as specified and directed. |
| 78 | M&L for 75mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection and finished even and smooth with using extra cementcomplete all as specified and directed. |
| 79 | Repairs of rolling shutter door any size and incl taking down, refixing in same opening after alingment & greasing as required complete all as specified and directed. |
| 80 | S&F in repairs 15 mm CP Bib cock 2 way with wallflange and single knobscomplete with all fittings complete all as specified and directed. |
| 81 | S&F in repairs CP Overhead rain shower - ABS type Square 150x150mm complete with all fittings complete all as specified and directed. |
| 82 | S&F in repair Health Faucet ABS bodymild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified and directed. |
| 83 | S&F in repair urinal spreader of chromium plated of any colour for fixing with 15 mm dia pipecomplete all as specified and directed. |
| 84 | Dismantling of ceiling board/false ceiling any Size and thickness complete all as specified and directed. |
| 85 | Providing and fixing Gypsum Board false ceiling tile (size 595x595mm) 12mm thick in false ceiling complete all as specified and directed. |
| 86 | M&L for Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm all as specified and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. |
| 87 | Providing & fixing false ceiling atall heights with GRG (Glass FibreReinforced Gypsum) false ceiling tiles ofSize 595 x 595 mm with semi perforated 12mm thick micro tegular edged GRG false ceiling tilesof approved texture, 12mm thick thick micro tegular design and patterns having moisturecontent less than 2%, humidity resistanceof 99%, NRC0.50 to 0.75 as per IS8225:1987, Noncombustible as per BS4 76 (part 4 )-1970 and light reflectance of85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqmincluding both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. |
| 88 | S&F in repair stainless steel grating doom150x150mm complete all as specified and directed. |
| 89 | Dismantling/removal of existing water proofingmembrane, including of cement plaster of any description and any thicknessand removal ofmaterial out of MOD land/sites etc complete all as specified and directed. |
| 90 | M&L for rendering in CM (1:3) 10mm thick over RCC roof, chajja/ brick wallmixed with water proofing compound @ 3% by weight of cement finished even and fair without using extra cement complete all as specified and directed. Note - WPC shall be measured and paid separately. |
| 91 | Supply only integral water proofing compound complete all as specified and directed. |
| 92 | M&L for preapring clean and dried plaster surface and applying a coat of oil based bitumen primer confirming to (IS: 3384) at the rate of 0.30 litrs per Sqm and then laying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced withnon woven polyster reinforced membrane having thermal insulation with mineral gravel on upper side of membrane land on primed surface by torch application methodcomplete all as specified and directed. |
| 93 | M&L ATT Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed. |
| 94 | M&L Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. |
| 95 | S&Fin repair CP bib cockwith wallflangefixed to15mm bore pipe complete with all fittings complete all as specified and directed.(Make- JaquarCat No. FON-40037 or equivalent as approved by GE.) |
| 96 | S&F in repair Angular stop cock with wall flange fixed to15mm bore pipe complete all as specified and directed.(Make- JaquarCat No. KUP-35053PM or equivalent as approved by GE.) |
| 97 | S&F in repair Pillar tap single lever tall boy without popup waste system fixed to15mm bore pipe complete all as specified and directed.(Make : Jaquar Cat part No OPP-35001PM or equivalent as approved by GE.) |
| 98 | S&F in repair Round shape thin rim Table top basin with fixing accessories of size 360mm x 360mm x 120mm complete all as specified and directed. (Make : Jaquar Cat part No SLS-WHT-6905 or equivalent as approved by GE.) |
| 99 | S&F in repair EWC with wall hung cistern, Drainage L Bend Pipe, Gasket and Installation Kit with PP normal close seat cover, Hinges, Fixing Accessories, Accessories Set and Cistern fitting, of size 350x480x395 mm with S trap complete all as specified and directed.(Make JaquarCat No. CNS-WHT-551SNSPP184LZ or equivalent as approved by GE.) |
| 100 | S&F in repair 15 mm CP Bib cock 2 way with wallflangefixed to15mm bore pipe complete with all fittings complete all as specified and directed.(Make- JaquarCat No. KUP-35041PM or equivalent as approved by GE.) |
| 101 | S&F in repair CP Health Faucet with 8mm dia, 1.20 mtr long flexible tube & wall hook complete all as specified and directed.(Make- JaquarCat No. ALD-573 or equivalent as approved by GE.) |
| 102 | S&F Geotextile membrane of approved quality with necessary fitting arrangements and lapping at joints as per manufactures instuctions in reachage pit at regular intervals complete all as specified and directed |
| 103 | M & L for preparing bituminous/ concrete surfaces of road and marking centre lines, stop lines, dashes, arrows etc. and the like on roads pavements with hot applied thermo plastic(2.5mm thick) / water based for tarmac area road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. |
| 104 | Racking out old polysulphide or Polyurethane joint sealant with special tools like cutting blades / Machine and joint cleaned on thoroghly with application of compressed air. Make necessary cutting arrangement of cutting of PQC where required. The joint shell be made dry and free of dirt and vacuum cleaned by a mechanical device as well as free of oil, vegetation and other debries . Two coats of primer should be applied with in thin brush by the forward and backword moverment at an interval of 30 minutes before pouring the sealent(i.e. one side will be brushed twice forward and backword with adequate quantity of primer and applicant temprature of the sealants should be strictly adhered to as per manufacture instruction. The penumatic pressure while application should not be too high which causes a high speed flow and results in overfilling of joints. Too low pressure form small bubbles which can be starting point for cohesive failures. Every air bubbles that appeared on the surface should be immediately popped with levelling tool. A masking tape from existing Dummy/Contraction joints of dimension 10 mm wide and 10 mm deep and removing the sealant outside the MD landand fixing 12 mm dia polyethylene rod in position as required incl treating the sides and bottom of the joint with primer suitable for sealant and refilled with polyurethane joint sealant compound with masking tape using mechanical means to a minimum depth of 8 mm and minimum movement accommodation factor (MAF)=30% conforming to requirements of BS-5212,BS-4254 and EN 141875-2003 for hydrolysis/ water resistance test and making good surface all as per manufactures instructions. Make : Fosroc, Sika or equilavent as approved byEngr-in- Charge. |
| 105 | Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity exc 250 Ltr n exc 500 Ltr capacity complete all as specified and directed. |
| 106 | Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity exc 500 Ltr n exc 1000 Ltr capacity complete all as specified and directed. |