| 1 | Taking down cement or cement lime plaster, any description on brick,RCC or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc,complete all as specified and directed by Engineer-in-Charge |
| 2 | M & L 15 mm thick rendering on other than fair faces of brick walls in two layers, 1st layer 10mm thick in CM 1:6 and 2nd layer in CM 1:4 with using water proofing compound, finished fair & smooth w/o using extra cement.( WPC to be measured separately under respective item) |
| 3 | Supply only water proofing compound |
| 4 | M&L water proofing treatment to floor & wall of static water tank(SWT) as described below complete all as specified & directed(i) Dewatering of existing water by any means and making surface dry(ii) Cleaning & preparation of old RCC /PCC/brick surface of SWT above or below ground level removing grass/algae/fungus/loose concrete/loose particles & plaster etc and making surface clean dry and dust free.(iii)Applying four layer water proofing system , Ist coat of SBR latex,2nd coat of component elastomeric flexible water tight, crack bridging water proofing coat ,3rd coat with same sandwich layer of 45 GSM glass fiber mesh Note:Make: STP/SIKA/FOSROCThe water proofing treatment will be carried out by the manufacture or their authorized applicator duly approved by GE in writing for guarantee & security deposit ref PS |
| 5 | Demolition of unreinforced cement concrete in ground floors and paving n.exc 15cm thickness(below or above ground level) complete all as specified and directed by Engineer-in-Charge. |
| 6 | M & L for PCC 1:1.5:3, type A-2, using 20mm graded crushed stoneaggregateas in foundation , filling and mass concrete. |
| 7 | M & L for 50mm thick PCC 1:3:6 type B-1, using 20mm graded stone aggregate as in plinth protection, laid in slope in 1:30 in pannels n. exc. 2m long, concrete surfaces finished even and smooth without using extra cement |
| 8 | M & L for preparation of new plastered surfaces of walls applying two coat of cement base paint of approved shade complete as spd & directed |
| 9 | Demolition of cement concrete(unreinforced) of any description above 15 cm and in any position not otherwise specifically provided |
| 10 | Removing building materials etc.to a distance of 2 Km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination |
| 11 | M & L for cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using400 kg of cement per cubic metre, thickness of concrete 25 cm or less, finishing surface of concrete pavement by brooming of concrete pavement complete while concrete is green complete all as specified and as directed. |
| 12 | M & L for Forming 12 mm thick depth 200 mm expansion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete. |
| 13 | M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade \"A\" complete. |
| 14 | Dismantling structural steel work includingdoors, gates but excluding framed truss etc.as in girder, purlin, trusses, wind ties or framed work of false ceilingin any position and in any description complete all as specified and directed by the Engineer-in-Charge. |
| 15 | S&FRooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) (Fe-410 Grade E-250) including distance pieces, cleats etc |
| 16 | S&F mild steel work as in wind tie for roof covering complete all as specified and directed by Engineer-in- charge. |
| 17 | Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 18 | Removing building materials etc.to a distance of 2 Km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination |
| 19 | M&L for providing cement concrete 100 mm thick Type D-2, 1:4:8in foundations, filling and mass concrete and complete all as specified. |
| 20 | M&L for sand filling under floors or in foundations 25 mm thick in cluding watering and consolidation and complete all as specified. |
| 21 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15698-2006 of 100 mm thickness , M-35 grade with grey cement and pigment and complete all as specified. |
| 22 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15698-2006 of 60 mm thickness , M-35 grade with grey cement and pigment and complete all as specified. |
| 23 | M&L for Machine pressed precast concrete interlocking paver blockany shape and size confirming to IS 15698-2006 of 60 mm thickness , M-35 grade with grey cement and no pigment and complete all as specified. |
| 24 | M & L Providing and laying at or near ground level factory made kerb stone of M-35 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 25 | Excavation in over areas n exc 1.50 m in depth and getting out in soft/ integrated rock |
| 26 | Excavating in trenches n exc 1.50 m inwidth and n exc 1.50 min depth for foundation,manholes etc as well as n exc 10 sqm on plan areaand getting out in soft/ integrated rock all as specified and directed. |
| 27 | Removal of exacavated ROCKto a distanceexc 250 and n. exc. 500m m and depositing where as directed at a level of 1.5 m above the starting point complete all as specified and directed. |
| 28 | M & L for PCC 1:4:8 , type D-2, using 40mm graded crushed stoneaggregateas in foundation , filling and mass concrete. |
| 29 | M&L sand Stone slab 25 to 35 mm thick, dressedTrue and squre in one length not less than 60 CM and n exc 120 CM in coping, window cill , chajjs, sunshed etc, punched dressed on exposed faces and self faced on the embeded unexposed bed and joints exposed edges rounded and chamfered as directed set jointed in cement mortor. |
| 30 | M&L for PCC block masonarywith solid blocks exc 10 cm in width 1:3:6 Type C1 20 mm graded aggregate and setting in mortar complete . |
| 31 | M & L PCC 1:4:8type D-2 using 40mm graded aggregate as in 75mm thicksub base . |
| 32 | M&L for25mm thick PCC (1:2:4),typeB-0, using 12.5 mm graded stone aggregate as in floor complete all as spfd & directed. |
| 33 | M&L for preparation of new steel & Iron surface of width or grith exceeding 10cm & applying two coats of synthetic enamel paint of 1st quality complete all as spd & directed. |
| 34 | Steel work in tubular trussesincluding special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 |
| 35 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment |
| 36 | Pre-painted galvalumealuminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 37 | M&L for pre-cast cement concrete type B1 (1:2:4) using 20mm graded stone aggregate) as in road side kerbs size and shape as specified and directed by Engineer-In-Charge complete. |
| 38 | Excavation in over areas n exc 1.50 m in depth and getting out in soft / loose soil . |
| 39 | Removal of exacavated soil in soft & loose soil to a distanceexc 250 and n. exc. 500m m and depositing where as directed at a level of 1.5 m above the starting point complete all as specified and directed. |
| 40 | M & L 40mm thick sand stone slabs, dressed close picked on exposed faces, set and jointed in cement and stone dust mortar 1:3 and pointed in cement mixed with approved pigment to match |
| 41 | S & F stainless steel letters of size 9\" to 12\"\" at any height complete all as specified and directed. |
| 42 | M&L for Squared rubble stone walling , well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed |
| 43 | M & L 15 mm thick rendering on fair faces of brick walls in CM 1:4 , finished fair & smooth w/o using extra cement. |
| 44 | M & L PCC 1:4:8type D-2 using 40mm graded aggregate as in 75mm thicksub base . |
| 45 | S &F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; cooler stand; 12 mm sq gaurd bar framework of water tanksand similar work con- forming to Fe.290.Gde-E-165 |
| 46 | M&L Wire netting of stainless steel wire 1.23mm dia fixed with tinned tacks of stainless steel wire staples Size of mesh in 12 mm |
| 47 | S&F water tubing 20mm bore, medium weight ISI marked galvanized with all fittings & fixed to walls, ceiling or laid in floors complete all as spd & directed. |
| 48 | S&F in repair stop valve cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union 20 mm dia, ISI marked complete all as spd & directed |
| 49 | M&L Jodhpur stone slab patties self faced, 7.5cm thick laid dry in single width in trenches as covering to cables etc. |
| 50 | Surface excavation averaging 15 cm deep and not exceeding 30 cm deep and getting out in soft and loose soil. |
| 51 | M&L for pre-cast cement concrete type B1 (1:2:4) using 20mm graded stone aggregate) as in road side kerbs size and shape as specified and directed by Engineer-In-Charge complete. |
| 52 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cmcomplete all as specified and directed. |
| 53 | M&L Cement concrete type B1 1:2:4 (20mm graded) in foundations, filling and mass concrete complete all as specified and directed. |
| 54 | M&L for Brick work with flyash bricks, straight or curved on plan n.exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed |
| 55 | M&L for Cement concrete 1:2:4 type B1(20mm aggregate) in foundations, filling and mass concretecomplete all as specified and directed |
| 56 | S&f for Framed work(Fe 410-W(Gde-E-250 Quality A) as in doors or gates of angle or other section with gusset plates, railing, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed |
| 57 | M&L for preparation of new or previously untreated surfaces of walland applying two coat of cement based paint over a coat of alkali resistant priming paint complete all as specified and directed. |
| 58 | Cutting holes in in stone walls built in cement mortar inserting holdfasts and making good dismantled portion in cement concrete 1:2:4 Type B-1 as requiredmath to existing wall paint surface and derbies removing from site all as specified and directed. |
| 59 | M&L for preparation of new steel and iron surfaces of any description exc 10 cm width or girth and applying two coats of synthatic enamel paint over one coat of red oxide primercomplete all as specified and as directed by Engr-in-Charge. |
| 60 | S&F 50mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge. |
| 61 | Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, pier holes, for foundations of poles, struts, stays etc. or layingunderground cable and water supply pipe lines etc.in hard/dense soil/rocks,& getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge. |
| 62 | Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil/\ complete all as specified and directed by Engineer-in-charge. |
| 63 | Removal of excavated soil material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge. |
| 64 | S&F ingun metal globe or gate valve 50mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge. |
| 65 | Supply, Fixing, Installation and Commissioning of Submersible underground sump openwell, 5 HP motor pump, 3 phase 50 mm Delivery headwith stainer all as specified and as directed. |
| 66 | Supply lay & testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, laid in trenches/passing through piperduct or fixed to wall/pole etc., and connecting up complete all as specified and directed for the following size of cable(i) 16 Sqmm 4 Core |
| 67 | Supplying & Fixing of MCCB 4 Pole, 415 V, Adjustable type, 16 KA thermal Magnetic 160 Amps with breaking capacity 36 KA complete all as specied and as directed. |
| 68 | Supplying, laying & jointing in replacement submersible cable flat type, copper conductor of size 4 Sqmm 3 core complete all as specified & as directed by Engineer –in-charge. |
| 69 | Supplying, Installing, testing and commissioning of outdoor type factory made CRCA sheet,thickness 3.15 mm platform mounted LT Panel board to accommodate the following items and built upon angle iron frame suitable size compatmentalized design work, dully powder coated with gray paingt and suitable size of cable glands chromium plated and copper busbars TPN 160 Amps , 415 V, 50Hz complete as following :-(i) MCCB 100 Amps, 4 Pole 36 KA -01 Incoming (ii) MCCB 63 Amps, 4 Pole 25 KA -01 Outgoing (iii) Voltmeter 0-500 v digital type with selector switch -01 Nos (iv) Amp meter 0-200 A digital type with selector switch -01 Nos (v) fully automatic star delta Starter suitable for 05 HP -01(vi)Indicating lamp LED RYB set of three with colour coding -01 Nos(vii) Push button for ON / OFF - 01 Set |
| 70 | Taking up or down 50mm bore galvanised steel water tubing including connections, fixed in walls, ceiling or laid under floor or laid in trenches etc complete all as specified and directed by Engineer-in-charge.Note :-Excavation and earthwork shall be measured and paid for separately. |
| 71 | All as per Srl item No 70 above but 40 mm dia bore. |
| 72 | S&F 50mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge. |
| 73 | All as per Srl item No 72 above but 40 mm dia bore. |
| 74 | Supplying, laying & jointing in replacement submersible cable flat type, copper conductor of size 6 Sqmm 3 core complete all as specified & as directed by Engineer –in-charge. |
| 75 | All as per serial item No. 74 here-in-above but 4 Sqmm 3 core. |
| 76 | M&L for rewiding of submersible pump set of capacity 1/2 HP with PVC insulated copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts complete all as specified and as directed by Engineer –in-charge |
| 77 | S&F in replacement on / off switch (push button) complete all as specified & as directed by Engineer-in-charge |
| 78 | Preparation of old painted steel surfaces of panel body of any size incl scrapping old paint, denting and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. |
| 79 | M&L for complete removal of existing paint of Elect motor with pump including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. |
| 80 | S&F in replacement gun metal globe or gate valve 40 mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge. |
| 81 | All as per Srl item No 80 above but 50 mm dia bore. |
| 82 | M&L for taking down carefully ceiling fans with fan down rod of any length by disconnecting electrical connections and fixing the same with new Anti suicide fan down rod 10 inch (off white color), hanging fan and making necessary electrical connectinons, testing fan for its smooth functioning. Antisucide Fan rod shallmanufactured with inbuilt spring so as to brake and hang on spring when load on fan exceeds 20 kg. Fan rods shall be tested and approved by Govt of India MSME Labotary all as specified and directed. Make- GOLD LIFE manufactured by Safe soluction, Mumbai or equivalen in similar specification in approved makes. |
| 83 | M&L for taking down carefully ceiling fans with fan down rod of any length by disconnecting electrical connections and fixing the same with new Anti suicide fan down rod 15 inch (off white color), hanging fan and making necessary electrical connectinons, testing fan for its smooth functioning. Antisucide Fan rod shallmanufactured with inbuilt spring so as to brake and hang on spring when load on fan exceeds 20 kg. Fan rods shall be tested and approved by Govt of India MSME Labotary all as specified and directed. Make- GOLD LIFE manufactured by Safe soluction, Mumbai or equivalen in similar specification in approved makes. |
| 84 | M&L for taking down carefully ceiling fans with fan down rod of any length by disconnecting electrical connections and fixing the same with new Anti suicide fan down rod 18 inch (off white color), hanging fan and making necessary electrical connectinons, testing fan for its smooth functioning. Antisucide Fan rod shallmanufactured with inbuilt spring so as to brake and hang on spring when load on fan exceeds 20 kg. Fan rods shall be tested and approved by Govt of India MSME Labotary all as specified and directed. Make- GOLD LIFE manufactured by Safe soluction, Mumbai or equivalen in similar specification in approved makes. |