| Sl. No. | Item Description |
| 1 | M & L taking out and dismanteling of mono block fountain pump set openwell any type of Cap up to 5 HP, 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, transporataion to workshop & dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors and testing including replacing worn out nuts, bolts, washers, Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :-Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item . |
| 2 | supply only bush with oiling and greasing as required. |
| 3 | Supply only ball bearing as per existing. Make:- NBC/SKF/TATA |
| 4 | Supply only pump shaft as per existing |
| 5 | Supply only terminal box including connectors of copper, plate of motor. |
| 6 | Cutting of burnt winding and rewinding the stator with supper enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc. complete all as specified and directed. |
| 7 | M & L for transporataion & dismanteling of centrifugal pump set of cap 5 to 7.5 HP 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors in proper manner and testing including replacing worn out nuts, bolts, washers, Lathe machine work, gland packing pipe, Air vent key complete and lowering the same and reconnecting to pipe line and electric connection after repairs as directed by Engineer-in-charge Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant items of BOQ. |
| 8 | Supply only bush with oiling and greasing as required. |
| 9 | Supply only ball bearing as per existing. Make:- NBC/SKF/TATA |
| 10 | Supply onlyShaft sleeve bronze as per existing |
| 11 | supply only shaft metallic coupling with key & star rubber set. |
| 12 | M & L for transporattaion & dismanteling of centerifugal pump set of Cap 12.5HP 3 phase, 415 volts, 50Hz, AC supplyafter disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors in proper mannerand testing including replacing worn out nuts, bolts, washers, Lathe machine work, gland packing pipe, Air vent keycomplete and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :-Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item |
| 13 | supply only bush with oiling and gresing as required. |
| 14 | Supply only ball bearing as per existing. Make:- NBC/SKF/TATA |
| 15 | Supply only Shaft sleeve bronzeas per existing |
| 16 | M & L for transporattaion & dismanteling of centerifugal pump set of Cap 20 HP 3 phase, 415 volts, 50Hz, AC supplyafter disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors in proper manner and testing including replacing worn out nuts, bolts, washers , Lathe machine work, gland packing pipe, Air vent key complete and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :-Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item |
| 17 | supply only bush with oiling and gresing as required. |
| 18 | Supply only ball bearing as per existing. Make:- NBC/SKF/TATA |
| 19 | Supply only damaged star rubber coupling as per existing |
| 20 | Shaft sleeve bronze as per existing |
| 21 | supply only shaft metallic coupling with key. |
| 22 | M & L for transporattaion & dismanteling of centerifugal pump set of Cap 30 HP 3 phase, 415 volts, 50Hz, AC supplyafter disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors in proper manner and testing including replacing worn out nuts, bolts, washers , Lathe machine work, gland packing pipe, Air vent key complete and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :-Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item |
| 23 | supply only bush with oiling and gresing as required. |
| 24 | Supply only ball bearing as per existing. Make:- NBC/SKF/TATA |
| 25 | Supply only damaged star rubber coupling as per existing |
| 26 | Shaft sleeve bronze as per existing |
| 27 | supply only shaft metallic coupling with key. |
| 28 | Supply only stainless steel shaft as per existing |
| 29 | M & L for transporattaion & dismanteling of centerifugal pump set of Cap 40 HP 3 phase, 415 volts, 50Hz, AC supplyafter disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors in proper manner and testing including replacing worn out nuts, bolts, washers , Lathe machine work, gland packing pipe, Air vent key complete andreconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :-Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item |
| 30 | supply only bush with oiling and gresing as required. |
| 31 | Supply only ball bearing as per existing. Make:- NBC/SKF/TATA |
| 32 | Supply only damagedstar rubber coupling as per existing |
| 33 | Supply only gun metal impeller |
| 34 | Shaft sleeve bronze as per existing |
| 35 | supply only shaft metallic coupling with key. |
| 36 | Supply only stainless steel shaft as per existing |
| 37 | M & L for transporattaion & dismanteling of centerifugal pump set of Cap 50 HP 3 phase, 415 volts, 50Hz, AC supplyafter disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors in proper manner and testing including replacing worn out nuts, bolts, washers, Lathe machine work, gland packing pipe, Air vent key complete reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :-Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item |
| 38 | supply only bush with oiling and gresing as required. |
| 39 | Supply only ball bearing as per existing. Make:- NBC/SKF/TATA |
| 40 | Supply only damagedstar rubber coupling as per existing |
| 41 | Shaft sleeve bronze as per existing |
| 42 | supply only shaft metallic coupling with key. |
| 43 | M&L for transporataion & dismantling of existing defective induction motor of the Pumpset capacity 50 HP, 03 phase, 415 Volt sizes from the foundation, disconnecting the electric connection, coupling joint and transporting to workshop for cutting down and removing existing burnt copper windings, clenining of slots and rewinding with supper enameled copper conductor complete including varnishing, drying, ovening, overhauling, greesing, necessary lathe work and replacement of bearing and fixing in the original position, making neccessary electric connection and coupling connection and testing of induction motor complete all as specified and as directed by Eng in charge |
| 44 | ,---ditto--- all as per srl item No 8 above but Induction motor of pumpset of 40 HP Capacity, 03 phase, 415 Volt complete. |
| 45 | ,---ditto--- all as per srl item No 8 above but Induction motor of pumpset of 30 HP Capacity, 03 phase, 415 Volt complete. |
| 46 | ,---ditto--- all as per srl item No 8 above but Induction motor of pumpset of 20 HP Capacity, 03 phase, 415 Volt complete. |
| 47 | ,---ditto--- all as per srl item No 8 above but Induction motor of pumpset of 12.5 HP Capacity, 03 phase, 415 Volt complete. |
| 48 | ,---ditto--- all as per srl item No 8 above but Induction motor of pumpset of 7.5 HP Capacity, 03 phase, 415 Volt complete. |
| 49 | ,---ditto--- all as persrl item No 8 above but Induction motor of pumpset of 5 HP Capacity, 03 phase, 415 Volt complete. |
| 50 | M & L for lifting out submersible pump set of Capacity 7.5 HP, 3 phase, 415 volts, 50Hz, AC supply along with column pipe of any size from the bore well after disconnecting electric connection, dismantling of pump and motor and transportation to workshop for repairing/ replacing defective parts as ordered, oiling, greasing as required and re-assembling and testing including replacing worn out nuts, bolts, washers, lathe machine work etc complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed.Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant item of BOQ. |
| 51 | Supply only stainless steel pumpshaft. |
| 52 | Supply only impeller with neck key and distance bush. |
| 53 | Supply only Shaft bush. |
| 54 | Supply only thrust bearing with plate of pump : |
| 55 | Supply only rubber gasket 3mm thick of any size |
| 56 | Cutting of burnt winding and rewinding the stator with PVC insulated copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles, mechanical oil seal with oil etc. |
| 57 | M & L for lifting out submersible pump set of Capacity 10 HP, 3 phase, 415 volts, 50Hz, AC supply along with column pipe of any size from the bore well after disconnecting electric connection, dismantling of pump and motor and transportation to workshop for repairing/ replacing defective parts as ordered, oiling, greasing as required and re-assembling and testing including replacing worn out nuts, bolts, washers, lathe machine work etc complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed.Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant item of BOQ. |
| 58 | Supply only stainless steel pumpshaft. |
| 59 | Supply only impeller with neck key and distance bush. |
| 60 | Supply only Shaft bush. |
| 61 | Supply only thrust bearing with plate of pump |
| 62 | Supply only rubber gasket 3mm thick of any size |
| 63 | Cutting of burnt winding and rewinding the stator with PVC insulatedcopper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles mechanical oil seal with oil etc. |
| 64 | M & L for lifting out submersible pump set of Capacity 12.5 HP, 3 phase, 415 volts, 50Hz, AC supply along with column pipe of any size from the bore well after disconnecting electric connection, dismantling of pump and motor and transportation to workshop for repairing/ replacing defective parts as ordered, oiling, greasing as required and re-assembling and testing including replacing worn out nuts, bolts, washers, lathe machine work etc complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed.Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant item of BOQ. |
| 65 | Supply only stainless steel pumpshaft. |
| 66 | Supply only impeller with neck key and distance bush. |
| 67 | Supply only Shaft bush. |
| 68 | Supply only thrust bearing with plate of pump |
| 69 | Supply only rubber gasket 3mm thick of any size |
| 70 | Cutting of burnt winding and rewinding the stator with PVC insulatedcopper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles mechanical oil seal with oil etc. |
| 71 | M & L for lifting out submersible pump set of Capacity 15 to 17.5 HP, 3 phase, 415 volts, 50Hz, AC supply along with column pipe of any size from the bore well after disconnecting electric connection, dismantling of pump and motor and transportation to workshop for repairing/ replacing defective parts as ordered, oiling, greasing as required and re-assembling and testing including replacing worn out nuts, bolts, washers,lathe machine work etc complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed.Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant item of BOQ. |
| 72 | Supply only stainless steel pumpshaft. |
| 73 | Supply only impeller with neck key and distance bush. |
| 74 | Supply only Shaft bush. |
| 75 | Supply only thrust bearing with plate of pump |
| 76 | Supply only rubber gasket 3mm thick of any size |
| 77 | Cutting of burnt winding and rewinding the stator with PVC insulatedcopper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles mechanical oil seal with oil etc. |
| 78 | M & L taking out and dismanteling of openwell submersible pump set with motor of Cap22.5 HP, 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, transporataion to workshop & dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors and testing including replacing worn out nuts, bolts, washers, Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :-Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item . |
| 79 | supply only bush with oiling and gresing as required. |
| 80 | Supply only ball bearing as per existing. Make:- NBC/SKF/TATA |
| 81 | Cutting of burnt winding and rewinding the stator with supper enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles mechanical oil seal with oil etc. complete all as specified and directed. |
| 82 | S&F in repair DOL starter, 10 HP suitable for 3 phase, 415 volts AC supply, relay range 13 to 21 Amps, power contactor 32 Amps, combine V/A meter, voltmeter selector switch, rocker switch, single phase preventor, IP 54 protection, ON/OFF indication complete all as specified and directed. |
| 83 | S&F in repair of fully automatic star delta starter 15 HP Capacity , 3 phase, 415 volts AC supply, relay range 13 to 22 Amps, power contactor upto 32 Amps, combine V/A meter, voltmeter selector switch, rocker switch, single phase preventor, IP 54 protection, ON/OFF indication complete all as specified and directed. |
| 84 | S&F in repair of fully automatic star delta starter 20 HP Capacity, 3 phase, 415 volts AC supply, relay range 20 to 32 Amps, power contactor 32 Amps, combine V/A meter, voltmeter selector switch, rocker switch, single phase preventor, IP 54 protection, ON/OFF indication complete all as specified and directed. |
| 85 | S&F in replacement of VFD starter of capacity 50 HP centrifugal pump in existing panel wih switch for on/off at panel sheet and taking down old unsv complete all as specified and directed. Make:- LK Cat No. xD2000-88P0-4B1221 or equivalent in ABB/ Siemen/ C&S as approved by GE. |
| 86 | S&F in replacement of VFD starter of capacity 40 HP centrifugal pump in existing panel wih switch for on/off at panel sheet and taking down old unsv complete all as specified and directed. Make:-LK Cat No. xD2000-74P5-4B1221or equivalent in ABB/ Siemen/ C&S as approved by GE. |
| 87 | S&F in replacement submersible copper flat cable PVC insulated over all sheethed flat ISI marked of 1100 volts grade of 25 sqmm 3 core passing through and incl suitable size medium grade conduit/PVC pipe fixed on wall by clips from Starter to motor complete all as specified and directed. |
| 88 | S&F in repair MCCB, 63 Amp, 4 pole, 415 volts, 50 Hz 16 KA with adjustable thermal and adjustable magnetic protection releasr with spreader links including thimbles, nuts, bolts, washers andtaking down unsv complete all as specified and directed. |
| 89 | S&F in repair MCCB, 100 Amp, 4 pole, 415 volts, 50 Hz 16 KA with adjustable thermal and adjustable magnetic protection releasr with spreader links including thimbles, nuts, bolts, washers andtaking down unsv complete all as specified and directed. |
| 90 | S&F in repair MCCB, 200 Amp, 4 pole, 415 volts, 50 Hz 35 KA, microprocesor based including taking down unsv complete all as specified and directed. |
| 91 | S&F in repair MCCB, 400 Amp, 4 pole, 415 volts, 50 Hz 35 KA, microprocesor based including taking down unsv complete all as specified and directed. |
| 92 | Supply & fix straight through heat shrinkable cable jointing kit suitable for 1.1 KV, 3.5 core XLPE/ PVC armoured aluminium conductor cable of 16 Sqmm to 50 Sqmm size grade cable complete with jointing material and accessories including necessary earth work complete all as specified and directed. |
| 93 | ,---ditto--- all as per srl item No 30 above but 70Sqmm to 120 Sqmm size complete. |
| 94 | S&F in replacement of old U/S gland packing with new to the Pump set and valves of any sizes/capacity complete with neoprene rubber gasket, jointing material and incl nuts/bolts/washer of suitable size etc complete all as specified and directed. |
| 95 | S&F in repair 80mm bore size medium grade GI column pipe (ISI marked), both side flanged and welded (Each of 3 m length) including taking out old corroded column pipe both side flanged complete all as specified and directed. Note : Each pipe of 3m length shall be measured as one unit\" |
| 96 | ,---ditto--- all as per srl item No 33 above but 50 mm bore pipe complete. |
| 97 | Supply and fix in repair submersible copper cable PVC insulated over all sheethed flat ISI marked of 1100 volts grade of 6 sqmm 3 core passing through suitable medium grade conduit and conduit fixed with wall by clips from Starter to motor complete all as specified and directed. |
| 98 | Supply and fix in repair submersible copper cable PVC insulated over all sheethed flat ISI marked of 1100 volts grade of 10 sqmm 3 core passing through suitable medium grade conduit and conduit fixed with wall by clips from Starter to motor complete all as specified and directed. |
| 99 | Supply and fix in repair submersible copper cable PVC insulated over all sheethed flat ISI marked, 1100 volts grade of 4 sqmm 3 core passing through suitable medium grade conduit and conduit fixed with wall by clips from Starter to motor complete all as specified and directed. |
| 100 | Labour only for checking the serviceability of the different spares/ component/ parts of the starter and motor pump set/ panel/ phase sequential of any capacity at site complete all as directed by Engr-in-charge |
| 101 | M & L for Dismanteling of pressure pump set of cap upto 0.5 HP, single phase, 230 volts, 50Hz, AC supply after disconnecting electric connection, repairing/ replacing defective parts as ordered, re-assembling and testing including replacing worn out nuts, bolts, washers, bearing etcand winding by cutting of burnt winding and rewinding the stator with supper enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc. complete and electric connection after repairs as directed by Engineer-in-charge.Note : - (i) Minor spare part required for replacement and winding shall be included under quoted rates |
| 102 | Supply and fix in repair of universal pressure switch in existing pressure pump including taking down ols unsv complete all as specified and directed. Make : Denfoss or equivalent in siemen, ABB & C&S. |
| 103 | S&F in repair pressure pump of capacity 0.5 HP single phase 230 volts 50 HZ AC supply including all electric connection to the nearest point, testing and commissioning Complete as directed and specified by Engineer-in-charge. Make :- KSB, Crompton, Kirloskar or equivelent as approved by GE. |
| 104 | S & F in replacement of CI flanged foot valve of size 150mm ISI marked with all fittings, welding of flanged, nuts, bolts, washers, taking up of existing pipe from UG sump, fabrication work and taking down old unsv complete all as directed by Engr-in-charge |
| 105 | ,---ditto--- all as per srl item No 42 above but 50 mm bore pipe complete. |
| 106 | ,---ditto--- all as per srl item No 42 above but 40 mm bore pipe complete. |
| 107 | Providing area cleaning/sweeping of preimises water supply installation(Ph House) including cutting out green vegetation, roots, bushes, Treebranches,picking polothineand other unwanted material from the installation area and maintaining the ground surrounding the installation and removing the same out side the defence area as directed by Engr in charge. The approx area of installation kept clean all as under. (1) PH haldi ghati -6500 Sqm (2) Sub area booster pump house- 5200 Sqm (3) 61 Cav OHT - 900 Sqm (4) Signal Pump house-6100 Sqmm (5) PH No 03 and SP PH - 1800 Sqm (6) APS OHT - 1000 Sqm (7) JCO/OR OHT - 2500 Sqm (8) Comd Camp OHT - 900 Sqm (9) Comand Pump house - 5200 Sqmm (10) Queens road map ph - 6500 Sqm (11) khatipura Ph - 9200 Sqm (12) Para 3 Ph - 1200 Sqm (12) Ajaymeru ph & OHT - 1500 sqm (13) Booster PH QR - 1500 SqmNote :- (i) if contractor is fail to clean the area of installation complete in all respect else recovery @ 300 per installation/PH per day shall be recovered from his dues after 7 days of intimation to contractor and contractors claim shall not entertain on this account. (ii) Contractor provide required T&P like as(Broom, Axe,saw,boucket etc) (iii) Contractor will resposible to maintain the pump house area clean for contractual peroid.(iv) area shall be maintained clean throughout contract period and paid only once after completion |
| 108 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil including trimming of tree roots in trenches complete all as specified and directed. |
| 109 | Returning, filling-in, including spreading, watering and well ramming in layers notexceeding 25 cm thick each, in soft /loose soil complete all as specified and directed. |
| 110 | Removing excavated surplus soil to a distance not exceeding50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 111 | M & L Sand cushioning to PVC under ground cable with screened and washed tibba sand (non cohessive) and punning to provide a required cover complete all as specified and directed. Note :Punned thickness shall only be measured for payment. |
| 112 | M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) laid flat abutting each other with width of protection being equal to length of brick. The gap between adajcent bricks shall not exceed 10 mm as directed by Engineer-in-Charge. |
| 113 | M&L for PCC (1:3:6) type C1 using 20 mm graded aggregate for making good the disturbed portion of road/floor/platform/ header support column, support to UG sumps cover, valve chambers, pumps foundation etc including form work and compaction etc complete all as specfied and directed. |
| 114 | M&L for borig of existing road/path for laying of GI pipe for protection of cable and for passing DI pipe upto 150 mm dia including making good distrubed area/surface all as directed by Engr in charge |
| 115 | Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole of size 16 Sqmm 4 core including taking down old unserviceable cable complete all as specified and directed |
| 116 | Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole of size 25 Sqmm 3 ½ core including taking down old unserviceable cable complete all as specified and directed |
| 117 | Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole of size 70 Sqmm 3 ½ core including taking down old unserviceable cable complete all as specified and directed |
| 118 | Repair & maintenance of existing header, welding work, jointing of pipe, butter fly valve etc ofheader as per eixsting shape upto 50 mm to 600 mm bore pipe complete all as specified and directed. |
| 119 | S&F in repair for sluice valves, class PN 1.6 of 80mm bore size with cast iron body, non rising type and cast iron wheel head, both ends flanged, IS-14846 marked complete with neoprene rubber gasket, jointing material and incl nuts / bolts / washer of suitable size etc including taking down old unsv complete all as specified and directed. |
| 120 | ,---ditto--- all as per srl item No. 57 above but valve of size 100 mm bore complete. |
| 121 | ,---ditto--- all as per srl item No. 57 above but valve of size 150 mm bore complete. |
| 122 | ,---ditto--- all as per srl item No. 57 above but valve of size 200 mm bore complete. |
| 123 | S&F in repair for dual plate check non return valves, class PN 1.6 of 50mm bore size with cast iron body double disc of CS, Hinge pin, plate bearing, plugs of SS 410 and spring of SS316and both ends flanged, ISI marked comlete with neoprene rubber gasket ,jointing material, connected with existing MS pipe by jointing through flanged and welding work, rubber gasket, nuts/bolts/washer of suitable size etc including taking down old unsv complete all as specified and directed. |
| 124 | ,---ditto--- all as per srl item No. 61 above but valve of size 80 mm bore complete. |
| 125 | ,---ditto--- all as per srl item No. 61 above but valve of size 100 mm bore complete. |
| 126 | ,---ditto--- all as per srl item No. 61 above but valve of size 150 mm bore complete. |
| 127 | ,---ditto--- all as per srl item No. 61 above but valve of size 250 mm bore complete. |
| 128 | ,---ditto--- all as per srl item No. 61 above but valve of size 400 mm bore complete. |
| 129 | S & F Decrin dosing pump model 96NGQ51 High pressure single head gear Motored adjustable dosing pump of SpecificationAdjustable High Pressure - 0 to 100 PSIPower - 240 V, 50 HzHP - 1/30 fracionalOut put - 2 U.S. GPD to40 U.S. GPDALTOCH DOSING SYSTEM (MODEL ADS - I) consisting of 40 liter - 100 liter PE / FRP tank with PE / FRP Lid & level guage along with agitator with shaft & blade in plastic, mounted on tank with Acessories i.e lead tubing, connecting nuts, injection check valve, clay weight, ferrules of Make-Declibac/ Ion Exchange/ MAIC or equivalent approved by GE. |
| 130 | M&L Earthing complete as per electrical plate No 3 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8m below normal ground level connected to and including galvanised iron or steel earth strip 32X6 mmby means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole/ test point.Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive ofexcavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed.Note 1 - following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labourfor connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| 131 | M&L for Earth continuity conductor or main earthing lead of GI strip 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. including insulator, suitable size GI light grade pipe and taking down old unsv strip complete all as specified and directed. |
| 132 | M&L for testing & making earthing pit as per electrical plate No.3 with wire mesh, CI cover, Frame, funnel including testing of existing earthing and if result is within is not acceptable limit then improve the existing earthing by excavation and filled charcoal and salt, necessary PCC work and taking down old unsv complete all as specified and directed by EIC. |
| 133 | M&L for preparation of old painted steel surface of Centrifugal/ monoblock Pump sets ofcapacity upto 10 HP with two coat of RAL 7035/7032 paint by spraying machine including painting of base, cleaning, scraping foreign material and degreasing surfaces complete all as specified and directed. |
| 134 | ,---ditto--- all as per srl item No 71 above but pump set of 12.5 to 20 HP Capacity complete. |
| 135 | ,---ditto--- all as per srl item No 71 above but pump set of 30 to 50 HP Capacity complete. |
| 136 | M&L for preparation of old painted GI/MS/DI pipe surfaces upto 600 mm dia at various pump house/OHT and applying two coats of synthetic enameled paint over applying one coat of red oxide primer complete all as specified and directed. |
| 137 | Supply only drinking water chlorine test kit of ISI mark of range min 0.2 PPM to Max 5 PPM and PH meter of range min 0 to Max 14 as per specified and directed by EIC. |
| 138 | Disconnecting & taking out the existing unserviceableLT panel and S&F new outdoor Canopy type weather proof IP 54 LT panel board front opening hinged typed, double door with locking arrangement, made out of 3.15 mm thick CRCA sheet steel factory fabricated with powder coatingwith heat shrinkable PVC sleeves with colour code RYBN placed on insulators. The Aluminium bar RYBN having capacity is 1.5 times of main incomer MCCBs.The panel board shall be mounted 60 cm above ground level on a form work made out of MS channel of size 75 x 40 cm grouted on PCC Plateform.The sides of the form work shall be covered with 3.15 mm thick MS sheet and complete with necessary excavation PCC foundation, suitable cable glands for cable entry, change the burnt cable and lugs and refixing new cable lugs etc.The panel board shall be suitable housed with the following items:- (For Booster pump house 61 sub area)(i)4 Pole on load changeover switch 250 Amp (Main Incoming)-1 Nos (ii) 4 Pole MCCB 250 Amp with rupturing capacity 36 KA (main Incoming)-1 Nos (iii) 4 Pole MCCB 100 Amp with rupturing capacity 16 KA(Outgoing)-1 Nos (iv) 4 Pole MCCB 63 Amp with rupturing capacity 16 KA (Outgoing)- 4 Nos (v) 4 Pole MCCB 40 Amp with rupturing capacity 16 KA (Outgoing)- 3 Nos (vi)Volt meter 0-500 volts with selector switch.(vii) Amp meter 0-300 Amp with selector switch (viii)Phase indictor lamps LED type set of three (RYB)- 01 Set(ix) Single phase preventor at incomer -01 Nos(x) VFD starter for 30 HP Motor of LK Cat No. xD2000-61P5-4B1221 or equivalent in ABB/ Siemen/ C&S - 03 Nos (xi) VFD starter for 7.5 HP Motor of LK Cat No. xD2000-15P8-4B1221 or equivalent in ABB/ Siemen/ C&S - 02 Nos (xii) VFD starter for 12.5 HP Motor of LK Cat No. xD2000-23P5-4B1221 or equivalent in ABB/ Siemen/ C&S - 01 Nos (xi) VFD starter upto 4.0 HP Motor of LK Cat No. xD2000-09P3-4B1221 or equivalent in ABB/ Siemen/ C&S - 01 Nos |
| 139 | Disconnecting & taking out the existing UnserviceableLT panel and S&F new outdoor Canopy type weather proof IP 54 LT panel board front opening hinged typed, double door with locking arrangement, made out of 3.15 mm thick CRCA sheet steel factory fabricated with powder coatingwith heat shrinkable PVC sleeves with colour code RYBN placed on insulators. The Aluminium bar RYBN having capacity is 1.5 times of main incomer MCCBs.The panel board shall be mounted 60 cm above ground level on a form work made out of MS channel of size 75 x 40 cm grouted on PCC Plateform.The sides of the form work shall be covered with 3.15 mm thick MS sheet and complete with necessary excavation PCC foundation, suitable cable glands for cable entry, change the burnt cable and lugs and refixing new cable lugs etc.The panel board shall be suitable housed with the following items:- (For MAP pump house QR)(ii) 4 Pole MCCB 250 Amp with rupturing capacity 36 KA (Main Incoming)-1 Nos(iii) 4 Pole MCCB 100 Amp with rupturing capacity 16 KA (Outgoing)-3 Nos(iv) 4 Pole MCCB 63 Amp with rupturing capacity 16 KA (Outgoing)- 1 Nos (v) 4 Pole MCCB 40 Amp with rupturing capacity 16 KA (Outgoing)- 3 Nos (vi)Volt meter 0-500 volts with selector switch.(vii) Amp meter 0-300 Amp with selector switch (viii)Phase indictor lamps LED type set of three (RYB)- 01 Set(ix) Single phase preventor at incomer -01 Nos(x) VFD starter for 40 HP Motor of L&T Cat No.xD2000-74P5-4B1221or equivalent in ABB/ Siemen/ C&S - 02 Nos (xi) VFD starter for 4 HP Motor of L&T Cat No.xD2000-03P3-4B1221or equivalent in ABB/ Siemen/ C&S - 01 Nos |
| 140 | Disconnecting & taking out the existing UnserviceableLT panel and S&F new outdoor Canopy type weather proof IP 54 LT panel board front opening hinged typed, double door with locking arrangement, made out of 3.15 mm thick CRCA sheet steel factory fabricated with powder coatingwith heat shrinkable PVC sleeves with colour code RYBN placed on insulators. The Aluminium bar RYBN having capacity is 1.5 times of main incomer MCCBs.The panel board shall be mounted 60 cm above ground level on a form work made out of MS channel of size 75 x 40 cm grouted on PCC Plateform.The sides of the form work shall be covered with 3.15 mm thick MS sheet and complete with necessary excavation PCC foundation, suitable cable glands for cable entry, change the burnt cable and lugs and refixing new cable lugs etc. The panel board shall be suitable housed with the following items:- (For Jadhunath Vihar pump house)(i) 4 Pole on load changeover switch 160 Amp(Main Incoming)-1 Nos (ii) 4 Pole MCCB 160 Amp with rupturing capacity 36 KA (Main Incoming)-1 Nos (iii) 4 Pole MCCB 63 Amp with rupturing capacity 16 KA (Outgoing)-2 Nos (iv) 4 Pole MCCB 40 Amp with rupturing capacity 16 KA(Outgoing)- 4 Nos(v)Volt meter 0-500 volts with selector switch.(vi) Amp meter 0-300 Amp with selector switch (vii) Phase indictor lamps LED type set of three (RYB)- 01 Set(viii) Single phase preventor at incomer -01 Nos (ix) VFD starter for 12.5 HP Motor of LK Cat No. xD2000-23P5-B1221 or equivalent in ABB/ Siemen/ C&S - 01 Nos(x) VFD starter for 7.5 HPMotor of LK Cat No. xD2000-15P8-4B1221 or equivalent in ABB/ Siemen/ C&S - 02 Nos (xi) VFD starter for 4 HP Motor of LK Cat No. xD2000-09P3-4B1221 or equivalent in ABB/ Siemen/ C&S - 01 Nos |
| 141 | Disconnecting & taking out the existing UnserviceableLT panel and S&F new outdoor Canopy type weather proof IP 54 LT panel board front opening hinged typed, double door with locking arrangement, made out of 3.15 mm thick CRCA sheet steel factory fabricated with powder coatingwith heat shrinkable PVC sleeves with colour code RYBN placed on insulators. The Aluminium bar RYBN having capacity is 1.5 times of main incomer MCCBs.The panel board shall be mounted 60 cm above ground level on a form work made out of MS channel of size 75 x 40 cm grouted on PCC Plateform.The sides of the form work shall be covered with 3.15 mm thick MS sheet and complete with necessary excavation PCC foundation, suitable cable glands for cable entry, change the burnt cable and lugs and refixing new cable lugs etc. The panel board shall be suitable housed with the following items:- (For Booster pump house QR)(i)4 Pole on load changeover switch 160 Amp (Main Incoming)-1 Nos (ii) 4 Pole MCCB 160 Amp with rupturing capacity 36 KA (Main Incoming)-1 Nos (iii) 4 Pole MCCB 63 Amp with rupturing capacity 16 KA(Outgoing)-2 Nos (iv) 4 Pole MCCB 40 Amp with rupturing capacity 16 KA(Outgoing)- 4 Nos (v)Volt meter 0-500 volts with selector switch (vi) Amp meter 0-300 Amp with selector switch (vii) Phase indictor lamps LED type set of three (RYB)- 01 Set(viii) Single phase preventor at incomer -01 Nos (ix) VFD starter for 4 HPMotor of LK Cat No. xD2000-09P3-4B1221 or equivalent in ABB/ Siemen/ C&S - 01 Nos(x) VFD starter for 20 HPMotor of LK Cat No. xD2000-39P2-4B1221 or equivalent in ABB/ Siemen/ C&S - 03 Nos |
| 142 | Disconnecting & taking out the existing UnserviceableLT panel and S&F new outdoor Canopy type weather proof IP 54 LT panel board front opening hinged typed, double door with locking arrangement, made out of 3.15 mm thick CRCA sheet steel factory fabricated with powder coatingwith heat shrinkable PVC sleeves with colour code RYBN placed on insulators. The Aluminium bar RYBN having capacity is 1.5 times of main incomer MCCBs.The panel board shall be mounted 60 cm above ground level on a form work made out of MS channel of size 75 x 40 cm grouted on PCC Plateform.The sides of the form work shall be covered with 3.15 mm thick MS sheet and complete with necessary excavation PCC foundation, suitable cable glands for cable entry, change the burnt cable and lugs and refixing new cable lugs etc. The panel board shall be suitable housed with the following items:- (For Ajaymeru pump house )(i)4 Pole on load changeover switch 100 Amp (Main Incoming)-1 Nos (ii) 4 Pole MCCB 100 Amp with rupturing capacity 36 KA (Main Incoming)-1 Nos (iii) 4 Pole MCCB 63 Amp with rupturing capacity 16 KA (Outgoing)-2 Nos(iv) 4 Pole MCCB 40 Amp with rupturing capacity 16 KA (Outgoing)- 4 Nos (v)Volt meter 0-500 volts with selector switch.(vi) Amp meter 0-300 Amp with selector switch (vii) Phase indictor lamps LED type set of three (RYB)- 01 Set(viii) Single phase preventor at incomer -01 Nos (ix) VFD starter for 7.5 HPMotor of LK Cat No. xD2000-15P8-4B1221 or equivalent in ABB/ Siemen/ C&S - 02 Nos(x) VFD starter for 30 HPMotor of LK Cat No. xD2000-61P5-4B1221 or equivalent in ABB/ Siemen/ C&S - 01 Nos(xi) VFD starter for 4 HPMotor of LK Cat No. xD2000-09P3-4B1221 or equivalent in ABB/ Siemen/ C&S - 01 Nos |
| 143 | Disconnecting & taking out the existing UnserviceableLT panel and S&F new outdoor Canopy type weather proof IP 54 LT panel board front opening hinged typed, double door with locking arrangement, made out of 3.15 mm thick CRCA sheet steel factory fabricated with powder coatingwith heat shrinkable PVC sleeves with colour code RYBN placed on insulators. The Aluminium bar RYBN having capacity is 1.5 times of main incomer MCCBs.The panel board shall be mounted 60 cm above ground level on a form work made out of MS channel of size 75 x 40 cm grouted on PCC Plateform.The sides of the form work shall be covered with 3.15 mm thick MS sheet and complete with necessary excavation PCC foundation, suitable cable glands for cable entry, change the burnt cable and lugs and refixing new cable lugs etc. The panel board shall be suitable housed with the following items:- (ForSignal pump house )(i)4 Pole on load changeover switch 100 Amp (Main Incoming)-1 Nos (ii) 4 Pole MCCB 100 Amp with rupturing capacity 36 KA (Main Incoming)-1 Nos(iii) 4 Pole MCCB 63 Amp with rupturing capacity 16 KA(Outgoing)-1 Nos(iv) 4 Pole MCCB 40 Amp with rupturing capacity 16 KA(Outgoing)- 6 Nos(v)Volt meter 0-500 volts with selector switch.(vi) Amp meter 0-300 Amp with selector switch (vii) Phase indictor lamps LED type set of three (RYB)- 01 Set(viii) Single phase preventor at incomer -01 Nos (ix) VFD starter for 12.5 HPMotor of LK Cat No. xD2000-23P5-4B1221 or equivalent in ABB/ Siemen/ C&S - 04 Nos(x) VFD starter for 04 HPMotor of LK Cat No. xD2000-09P3-4B1221 or equivalent in ABB/ Siemen/ C&S - 01 NosNote :- (a) Contractor shall be submitted the drawing for approval within 45 days of commencement of work for Boq Items No 82 to 87. (b) Contractor shall be ordered after approval of drawing. |
| 144 | Disconnecting and taking out exisitng LT over heated or burnt cable terminal/ joint at panel/feeder pillar & unserviciable portion of LT cable of any size, after that stretching/ opening cable to suitable required length etc and fixing aluminium lugs / joint material, Phase sequencial, cable gland and suitable nuts bolts & washer etc complete all as specified and directed by Engr-in-charge. |
| 145 | Collecting the sample of water from different point such as bisalpur water supply tap point at haldighati pump house, Piru line ph situated at diff locations of cantt for chemical and bacteriological testing of water from authorised govt lab /NABL approved lab for iron content in water, PH value, hardness, turbidity, chloride, fluoride and other parameters as per IS standards all as specified and directedNote : (i) Contractor will collect the water sample in presence of JE/Engr-in-charge and tested from NABL/ Govt approved lab and report submitted to AGE E/M in tripliacte. |
| 146 | Supply and fix MS First Aid box with necessary medicines at wall of each installation complete all as specified and directed. |
| 147 | M& L for dismanteling of existing Declibac chlorination pump set 02 HP and mixer motor of Cap 2 HP, single phase, 230 volts, 50Hz, AC supply after disconnecting electric connection,transport to workshop, repairing/ replacing defective parts such as ball bearing, motor rewinding with super enammelled copper wire, circulating fan blades, fan shaft, pvc pipes etc andre-assembling and testing including replacing worn out nuts, bolts, washers complete and connecting electric connection etc after repairs complete all as specified and directed.Note : Quoted rate shall be inclusive of all minor parts specified above and rewinding of motor are included in quotated rate. |
| 148 | Supply and filling of Co2 Gas in fire extenguiser of capacity upto 5 Kg capacity at various pump installation and also mentioned the date of refilling on extinguiser complete all as specified |
| 149 | Supply and filling of dry powder in ABC type fire extenguiser upto 5 kg capacity at various pump installation and also mentioned the date of refilling on extinguiser complete all as specified |
| 150 | M & L for bore development by mechanical machine in such a way that sand particles/ debris removed from bottom of casing pipe of 200/250 mm bore pipethrough necessary arrangement for indoor and outdoor borewells at various location complete all as specified and directed. |
| 151 | S & F Electro flow/ magnetic flow switch/ meter of 50/80 mm bore at various borewell location including cutting existing pipe and fixed flow switch by fixing flanged with rubber gasket with nuts bolts, welding and including taking down unsv complete all as specified and directed. |
| 152 | M & L for for making machine history sheet for pumps, motors, DG sets installed at pumps house at Suitable size ACP/ MS sheet, painted Pump name, capacity, year of installation, MES No etc and fixed with wall at top of machines including fixed arrangement complete all as specified and directed by EIC. |
| 153 | S & F submersible openwell motor of 2 HP capacity, 1 phase 230 volt for priming of pumps including connected suitable size submersible flat cable from motor to DOL starter and DOL starter fitted at wall inside pump house and connected DOL starter to LT Panel complete all as specified and directed by EIC. |
| 154 | S & F mild steel work as infor valves chamber cover, ug sump cover, Borewell cap for 200/250 mmcasing pipes and ladder for UG sump/ OHT etc, complete drilled for fixing of steel sheeting or other covering and two coat paint and one coat red oxide primer over iron confirming to Fe-290 Gde-E-165 complete all as specified and directed |
| 155 | M & L for testing of existing earthing at pump houses by help of digital/ Manual earthing clamp meter and take 3 reading of each earthing as per direction and in presense JE E/m and Engr-in-charge. Calculate the average value of resistance and report in registered format shall be submitted to the subdivision duly signed by contractor, JE E/M and Engr-in-charge and also write the avg value at earthing pit by help of permanent marker. If minor repair as GI strips jointing by bolts, any minor repair shall be done by contarctor with out extra cost. |
| 156 | Supply only calcium based high strength granular chlorination chemical (calcium hypochlorite having chlorine 65% to 70% ) for water treatment. Granular material shall be free of foreign material decomposing at 177 C soluble in water and alcohol not hygroscopic practically clear in water solution at saturation level. The material should not contain more than 5% to 10 % moisture and contain free chlorine 65 to 75 % complete.Note : (i) Brand name/batch number and complete particulars of manufacturer should be printed on the container/packing.(ii) Manufacturers test certificate shall be submitted for each container / consignment |
| 157 | Note:- (a) Material like Starter, submersible cables, MCCB, foot valves, sluice valves, Non return valves, GI strips, Earthing material, MS first aid boxes, Flow meters etc shall be procured by contractor in one time for Min 50% quantity of as mentioned in BOQ of approved make from authorised dealer of manufacturer within 30 days of date of commencement and purchase vouchers and manufacturer test certificate (where applicable) shall be submitted by contractor before claim of payment. After procurement contractor intimate the department in written, shown on site to Engr-in-charge with purchase voucher, if contractor failed to purchasing the material as per BoQ items recovery @ 500 per day will be recovered and contractor\"s claim on this account shall not be entertained.(b) Contractor shall be submitted the sample approval letter of incorporated BoQ items with in 7 days of date of commencement of work. (c) Contractor shall be attend the complaints of unsv pumps, unsv motors, unsv sluice valves, unsv borewell, unsv starter, unsv panels etc via telephonically, message, site order, letter, email, complaint shall be attend within 04 hours and rectify the same within 12 hours. (d)The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule \"A\"/BOQ |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail