| 1 | Supply, installation, connecting, commissioning and replacement of LT panel with CPRI approvedmainfactory fabricatedLT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 1200 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work height from ground level .9 mtrs and Iron angle work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) ACB, 4 Pole,415V, 50HZ 630 Amps 65 KA Manual Drawout type with microprocessor release -01 Nos(B) OUTGOING(i) MCCB adjustable thermal andmagnetic of400 Amps, 4pole, 415 Volts, 36 KA, with rotary mechanism - 04 Nos (ii) MCCB adjustable thermal andmagnetic of250 Amps, 4pole, 415 Volts, 36 KA , with rotary mechanism - 04 Nos iii) MCCB adjustable thermal andmagnetic of 63 Amps, 4pole, 415 Volts, 16 KA , with rotary macanism - 02 Nos(iv) Blank space for MCCBs of same capacity - 02 Nos(v) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(vi) Three phase Amp meter Accuracy Class 1.0, 0.5Inbuilt selector switch for 3 phase metersCT/PT site programmableFrequency parameter available in 3Ph - 8 Nos(vii) LED TypePhase indicator lamps for three phases set of three -08 Nos(viii) Selector switch - 08 Nos(ix) Busbar chamber having insulated aluminium busbar, each suitable for 1200 Amps for three phases and neutral -01 Set |
| 2 | Supply, installation, connecting, commissioning and replacement of LT panel with CPRI approvedmainfactory fabricatedLT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 720 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work height from ground level .9 mtrs and Iron angle work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) MCCB, 4 Pole,415V, 50HZ 400 Amps 36 KA adjustable thermal and magnetic with rotary mechanism-01 Nos(B) OUTGOING(i) MCCB adjustable thermal andmagnetic of250 Amps, 4pole, 415 Volts, 36 KA, with rotary mechanism - 02 Nos (ii) MCCB adjustable thermal andmagnetic of200 Amps, 4pole, 415 Volts, 16 KA , with rotary mechanism - 02 Nos(iii) MCCB adjustable thermal andmagnetic of160 Amps, 4pole, 415 Volts, 16 KA , with rotary mechanism - 02 Nos(iv) MCCB adjustable thermal andmagnetic of 100 Amps, 4pole, 415 Volts, 1 KA - 01 Nos(v) Three pole power contractor MNX-12-01 Nos(vi) Three pole power contractor MNX-12-01 Nos-02 Nos (vii) Three pole power contractor MNX-12-01 Nos-02 Nos(viii) Change over switch400 Amps 4 pole 415 volt with handle - 01 Nos(ix) MCB SPN \"C\" Series,240V/415V,50Hz,32 amps 10 KA-01 Nos(x) Power factor Controller - 01 Nos (xi) Blank space for MCCBs of same capacity - 01 Nos(xii) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(xiii) LED TypePhase indicator lamps for three phases set of three -08 Nos(Xiv) Selector switch - 08 Nos(xii) Busbar chamber having insulated aluminium busbar, each suitable for 720 Amps for three phases and neutral -01 Set |
| 3 | Supply, installation, connecting, commissioning and replacement of LT panel with CPRI approvedmainfactory fabricatedLT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 225 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work height from ground level .9 mtrs and Iron angle work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-(A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ,125 Amps 25KA micro processor -01 No. (B) OUTGOING (i) MCCB, 4 Pole,415V, 50HZ 63 Amps 16 KA adjustable thermal and magnetic -01 Nos(ii) MCB, SPN \"C\" Series,240V, 50HZ 63 Amps 10KA-02 Nos(iii) MCB, SPN \"C\" Series,240V, 50HZ 32 Amps 10KA-01 Nos (iv) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(v) LED TypePhase indicator lamps for three phases set of three - 01 set (vi) Busbar chamber having insulated aluminium busbar, each suitable for 720 Amps for three phases and neutral -01 Set (vii) Spare space for MCCB of same capacity -01 Nos |
| 4 | M & L for earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6.0 mm burried directly in ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 5 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, cast iron cover with lifting handle, funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 40 mm bore light grade 7.5 m long test point etc complete including taking down old U/S earthing.Note :- (i) Cost of earth strip and GI protection pipe up to a distance 7.5 metre shall be included inthe quoted rate. (ii )On testing after completion if the desired earth resistance less than 2 ohm is not obtained the earthing will be redone at no extra cost. |
| 5 | Supply and Layingincluding jointing and testingelectric under ground LT cable XLPE insulated armoured heavy duty aluminium conductor cable 1100 volts grade in trenches , ducts, pipe on walls, poles of following sizes |
| 6 | 10 Sqmm 2 core |
| 7 | 150 sqmm 3.5 core. |
| 8 | 240 Sqmm 3.5 core |
| 9 | 400 Sqmm 3.5 core |
| 10 | Taking out existing LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor from tranches/ducts/pipe, on wall, poles of following size and removing unserviceable cable from site to store :- |
| 11 | 10 Sq mm 2 core |
| 12 | 150 Sqmm3.5 core. |
| 13 | 240 sqmm 3.5 core. |
| 14 | 400 Sqmm 3.5 core |
| 15 | Excavation in trenches nexc 1.5 mtr wide and not exc 1.5m in depth for taking out cable / pipe line n.exc 10 sq mtr on plan and n.exc 1.5 mtr depth and getting out in soft/loose soil.Note:(i) During laying of XLPE cable through roads, pavement and any othersurface contractor will re-doneexisting surface as previous road and pavement without any extra cost. |
| 16 | Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm. |
| 17 | Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point. |
| 18 | M & L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable all as specified. Note :- Punned thickness shall be measured and paid. |
| 19 | M & L well burnt bricks sub class \"B\" as in protection of cable laid dry, flat abutting each other width wise all as directed |
| 20 | M&L for GI tubing light grade fixed on wall/pole laid in trenches/under road of the following sizes :- |
| 21 | 40 mm dia bore |
| 22 | 50 mm dia bore |