| 1 | Desert coolerM & L for taking down of Desert cooler 3000/4000 CFM air flow capacity, single phase, 230 Volts of any make & type for repairs / servicing after disconnecting electric/water connection, drain out water and carry out repair work such as repairing / replacement of internal worn out wiring, fan blade, fan motor, grass pad, switches, power supply cable, grill, side panels, Lead wire, 3 way distributor junction tee set, PVC elbow, Pump, and including provn of complete painting (internal & external), painting the external portion of desert cooler with 2 coat of synthetic enamel paint of Ist grade over a coat of zinc chrome primer after scarping existing painted surface and painting the interior portion of the cooler with one coat of anti corrosive plastic paint including preparation complete all as specified and directed.Note : (i) Spares/parts required for replacement shall be measured and paid separately as supply only in respective items\" (ii) Unit quoted rate shall be deemed includes the cost of painting. (iii) Cost of internal wiring with 1 Sqmm copper wire, Cost of 3 way distributor junction tee set , PVC elbow suitable for 15 mm dia pipe is included in unit rate quoted above. |
| 2 | M&L for dismentlling the fan motor of capacity upto 150 W, single phase 230 Volts of any make, 3 speed of installed desert cooler, rewinding the same with super ennamelled copper wire of appropriate gauge with insulating material complete after removing old burnt binding including servicing, change the unserviceable bush, shaft and testing after completion complete all as specified and directed by Engineer -in-Charge. |
| 3 | Supply only motor of desert cooler, 1350 RPM, 220V, 145W, heavy duty, 4 Core with 1 CM Round shaft along with new capacitor, motor holding legs & rings, for metal cooler to be fitted in Desert cooler (3000/4000) CFM air flow capacitycomplete all as specified and directed. |
| 4 | Supply only capacitor 4 mfd for desert cooler including necessary electrical connections, lugs, insulation tape etc complete.Make - Epcos/ Havells/ Asian or equivalent as approved by GE. |
| 5 | Supply only Fan Blade iron body with nut, Bolt, washer for (3000/4000) CFM Desert Cooler of any make all as per existing one complete all as specified and directed by Engr-in-charge |
| 6 | Supply only Submersible Vertical pump with suitable head for Desert coolers (3000/4000) CFM air flow capacity, 18 W,230 Volts, 1.65 meter head, LVS technology complete all as specified and directed.Make: Khaitan/Polar/Crompton/TEXMO or equivalent as approved by GE. |
| 7 | Supply only wooden shelving (wood wool pad) along with wire mesh for Desert cooler each set of three for 3000/4000 CFM, complete all as specified and directed by Engr-in-charge |
| 8 | Supply only PVC insulated with stranded copper conductor 1.5 Sqmm 3 core, ISI Marked, Flexible cable of lenght 1.5 RM along with 3 pin 5 Amps plugtop complete all as specified and directed by Engr-in-charge |
| 9 | Supply only Desert Cooler Fan regulator/selector switch, for upto 150 W fan motor (3000/4000) CFM capacity of any make all as per existing one complete all as specified and directed by Engr-in-charge. |
| 10 | Supply only Switch Piano 5 Amp single pole 230 volt 50 Hz, complete all as specified and directed by Engr-in-charge |
| 11 | Supply only plug top for desert cooler 3 pin 5 Amps, 230 Volt AC, ISI marked, complete all as specified and directed by Engr-in-charge. |
| 12 | Supply only iron frame motor holding clamps (set of 4) along with ring as per existing one with required no. of nut & bolt to hold fan as well as motor of Desert cooler all as specified and directed |
| 13 | Supply only Front Grill Air Divertor of iron with Selector Switch for Desert Cooler 3000/4000 Cum/Hr, complete all as specified and directed |
| 14 | Supply only desert cooler body (overall minimum size 26 inch x 26 inch x 39 inch) made out of 20 gauge galvanised iron sheet, depth of water tank shall be 11 inch (minimum) and Spray painting to external surfaces of cooler and anticrosive rubber paint to internal surface of water tank portion complete all as specified and directed. |
| 15 | Supply only Side Panels (set of 3) made of MS Sheet 2 mm thick for (3000/4000) CFM Desert Cooler, as per site complete all as specified and directed by Engr-in-charge |
| 16 | Supply only PVC flexible pipe (from vertical pump to distributer and distributer to side shutter approx 2 mtr)15mm dia for Desert cooler including 3 way distributor junction tee set,PVC elbow complete all as specified and directed by Engr-in-charge |
| 17 | Ceiling fanM&L for taking down defective ceiling fan of 1200/1400 mm sweep upto 150 W single phase any make after disconnecting electrically & mechanically incl transportation, dismantling, examine & carry out Re-winding the motor of ceiling fan with existing guage super enamelled copper wire of approved quality to maintain speed at load, along with one coat of spray painting with best quality enamel paint of required colour and approved brand to give an even shade and polishing with rubbing compound and wax polish including cleaning of surface and wiritng MES No, testing on full speed, replacing ball bearing, capacitor and fixing the fan on old or new position complete all as specified and directed by Engr-in-charge. Note:-(i) Ball bearing and fan capacitor of 2.5 / 3.15 mfd capacity will be replaced along with this job. No extra payment will be given on account of ball bearing & fan capacitor. |
| 18 | S&F in replacement ceiling fan complete with blades, 0.45m down rods, canopy set, rubber reel, electronic accessories 230 V, 1200mm sweep, min air delivery 210CFM with service value 6.00 BEE five stare rated with bushless direct current motor( BLDC) including 0.5 Sqmm three core PVC insulated flexible copper conductor multistranded wire from fan motor to ceiling and writing MES No. on fan body as requiredcomplete all as specified and directed by Engineer-in-Charge. Note:- Old ceiling fan will be deposited to MES store yard. |
| 19 | S&F in replacement AC film capacitor 2.5 /3.15 mfd capacity in FR plastic casing, suitable for any type ceiling fan including connection complete all as specified and directed. |
| 20 | S&F in repairs stepped type electronic fan regulator 240 V 50 HZ,100 Watts flush type (ISI marked) on the existing phenolic laminated sheet etc, complete all as specified and directed by Engr-in-charge. |
| 21 | S&F in replacement down road 300 mm long of approved quality for installation of ceiling fan complete alll as specified and directed by Engineer-in-Charge. |
| 22 | Exhaust fanM&L for taking down defective metal body exhaust fan 300 mm sweep up to 100 W single phase any make after disconnecting electrically & mechanically incl transportation, dismantling, examine & carry out Re-winding the burnt / short circuited winding with existing guage super enamelled copper wire to maintain speed at load, along with one coat of spray painting with best quality enamel paint of required colour and approved brand to give an even shade and polishing with rubbing compound and wax polish including cleaning of surface and wiritng MES No, testing on full speed, replacing ball bearing, capacitor and fixing the fan on old or new position complete all as specified and directed by Engr-in-charge. Note:-(i) Ball bearing and fan capacitor of 2.5 / 3.15 mfd capacity will be replaced along with this job. No extra payment will be given on account of ball bearing & fan capacitor. |
| 23 | M&L for taking down defective metal body exhaust fan 450 mm sweep up to 450 W single phase any make after disconnecting electrically & mechanically incl transportation, dismantling, examine & carry out Re-winding the burnt / short circuited winding with existing guage super enamelled copper wire to maintain speed at load, along with one coat of spray painting with best quality enamel paint of required colour and approved brand to give an even shade and polishing with rubbing compound and wax polish including cleaning of surface and wiritng MES No, testing on full speed, replacing ball bearing, capacitor and fixing the fan on old or new position complete all as specified and directed by Engr-in-charge. Note:-(i) Ball bearing and fan capacitor of 2.5 / 3.15 mfd capacity will be replaced along with this job. No extra payment will be given on account of ball bearing & fan capacitor. |
| 24 | S&F in replacement fan motor for 300 mm sweep metal body exhaust fan upto 100W of desired specifications (ISI Marked) to maintain current speed, air flow at load, complete all as specified and directed by Engr-in-charge |
| 25 | S&F in replacement fan motor for 450 mm sweep metal body exhaust fan upto 450W of desired specifications (ISI Marked) to maintain current speed, air flow at load, complete all as specified and directed by Engr-in-charge |
| 26 | S&F in repairs louvers of appropriate size for exhaust fan of (300 / 450 mm) sweep, complete all as specified and directed by Engr-in-charge. |
| 27 | S&F in repairs fasteners of appropriate size for exhaust fan of (300/450mm) sweep complete all as specified and directed by Engr-in-charge |
| 28 | Supply & fix in repairs nut/bolts of appropriate size for fixing loose exhaust fan of (300 / 450 mm) sweep complete all as specified and directed by Engr-in-charge |
| 29 | S&F in replacement exhaust fan, high speed, metal body, 300mm sweep, 1200 RPM, four blade, heavy duty motor, copper wound double ball bearings, grey colour with louver, nuts, bolts and washers incl three core 0.75sqmm copper cable connection with protective steel bird guard complete all as specified & directed.Note:- Old metal body exhaust fan will be deposited to MES store yard |
| 30 | S&F in replacement exhaust fan, high speed, metal body, 450mm sweep, 1400 RPM, four blade, heavy duty motor, copper wound double ball bearings, grey colour with louver, nuts, bolts and washers incl three core 0.75sqmm copper cable connection with protective steel bird guard complete all as specified & directed.Note:- Old metal body exhaust fan will be deposited to MES store yard |
| 31 | S&F in replacement fresh air fan of sweep 200 mm, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, 2700 RPM, copper winding incl making connections complete all as specified and directed. |
| 32 | Hot water appliances (Geyser)Taking down storage type water geysers of 25 ltrs capacity any type any make, any model, from its existing location, transportation to work shop for repairs and transportation back and reinstallation of geyser as per technical instructions and as directed by engr-in-charge and including the following:-(a) Dismantling complete geyser and carrying out complete overhauling i.e disconnecting electric and water supply and opening the heating plate, inner assembly, descaling complete assembly including heating element or otherwise. Replacement of defective heating element inlet and outlet tubes and refixing the assembly with gasket of good quality and tightening the nuts properly, reassembling geyser with all safety devices as specified in technical instructions and as directed by Engineer -in- Charge complete.Notes:- (i) Spare Parts, Safety devices with it required accessoriesshall be measured and paid saperately under respective items of schedule as supply only, labour for fixing the same are deemed to be included in rate quoted. |
| 33 | Supply only heating element 2.0 KW, 230 volts, ISI marked suitable for 25 litre capacity geysers of any type as required. |
| 34 | Supply only Thermostat 40 to 90 degree centigrade varying capactiy for 25 Ltrs capacity Geyser. |
| 35 | Supply only thermal-cutout with heating sensor rod (capillary type) overload relay/contactor (model T10020Amp 250 Volts) as per existing sample suitable for 25 litres capacity Geysers, Complete all as specified and directed by Engr-in-charge. |
| 36 | Supply only of neon indicator lamp round or rectangular type (ISI marked) complete all as specified and directed by Engr-in-charge. |
| 37 | Supply only 25 liter capacity stainless steel water tank having inlet /outlet assembly suitable for storage water heater of capacity 25 Ltrs having provn of any make housing thermostat, heating element including connected accessories provinding rubber gasket and holding nut bolts complete all as specified and directed. |
| 38 | Supply only pressure release safety valve for Geysers spring loaded suitable for 15 mm pipe chromium plated (ISI marked), Complete all as specified and directed by Engr-in-charge. |
| 39 | S&F in repair flexible copper wire PVC insulated, 3 core, 2.5 Sqmm dia multistranded, 1.5 meter longComplete all as specified and directed by Engr-in-charge. |
| 40 | M& L in repair for industrial type metal clad plug top suitable 15 Amp suitable for (geyser)water storage heater of capacity 25 Ltrs as per existing complete all as specified and directed. |
| 41 | M&L for replacement of old U/S Chromium plated flexible stainless steel pipe connection for cold water inlet/ hot water outlet pipe of size 15 mm dia complete with nipple/adaptors 450mm long (ISI marked), Complete all as specified and directed by Engr-in-charge. |
| 42 | S&F in repair MCBs of \"B\" curve, single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked, 240Volts incl connection testing and commissioning complete all as specified and directed. |
| 43 | S&F in repair MCBs of \"B\" curve, SPN 32 Amps having breaking capacity 10 KA, ISI marked, 240Voltsincl connection testing and commissioning complete all as specified and directed. |
| 44 | S & F in repair 20amp, single pole and neutral socket outlet, with 2 pole and earth, metal enclosed plug top in powder coated CRCA steel sheet enclosure recess mounted with chained matel cover for socket out let with and incl one double pole C curve MCB 20 Amps complete all as specified and directed. |
| 45 | M&L in repair for sub main wiring with two run of 4 Sqmm single core, 1100 V, PVC insulated, unsheathed, FRLSH multistranded copper conductor cable alongwith one run of 2.5 Sqmm single core, 1100 V, PVC insulated, unsheathed, FRLSH multistranded copper conductor cable as earth continuity conductor (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed PVC conduit of 20mm dia ISI marked ivory colour & fitting / fixing accessories of suitable size including making connection as required complete all as specified and directed. NOTE - Two run of 4 sq.mm phase and neutral wire & One run of 2.5 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length. |
| 46 | S&F in replacement electric water heater vertically wall mounting storage type of 25 litre capacity, BEE star rating 5, approved colour, heating element 2.0 KW, rated pressure 8 bar single phase, adjustable temperature setting knob for temperature setting between 25°C to 75° C, outer tank made of metal, inner tank made of extra thick superior cold rolled steel provided with high density PUF insullation complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.Note:- Old geyser will be deposited to MES store yard. |
| 47 | Water coolerM&L for dismantling / taking down water cooler of capacity 40/80 Ltr, any make and type, after discooncting electric and water connection, carrying out repair such as checking of, fan motor, compressor and other minor repair, tracing gas leakage, repairing / brazing of condenser / copper pipe circuit, refilling gas, replacement of unserviceable parts, making it serviceable, painting with one coat of synthetic enamel paint and wiritng MES No refixing the same after repair and testing the same complete all as specified and directed(i)Spare Parts required for replacement shall be measured separately under respective item of BOQ as supply only (ii) Gas will be measured and paid separately. (iii) All Engineering works shall be carried out at site/E/M store yard only in presence of JE/Engr- in- Charge, No equipment shall be transport/carry out to local market for repairs |
| 48 | Supply only refrigerant gas F-22/ R-22/ R-410A/ R-134(a) as per existing for filling in 40/80 capacity water cooler all as specified and directed. |
| 49 | Supply only new hermatically sealed compressor copper wound unit for operation on single phase, 230 V, 50 Hz, AC supply & confirm to IS-1067 Part-I,suitable for Water cooler of cooling capacity 40/80 ltrs/hrs and connecting u and testing complete all as specified and directedMake - Kirloskar/Godrej/LG/Tecumseh or equivalent as approved by GE. |
| 50 | Supply only condensor motor 1/10 HP 230V, SP, 50 Hz suitable for 40/80 capacitywater cooleras per existng sample etc complete all as specified and directedMake : LG/Universal/Airmaster or equivalent as approved by GE. |
| 51 | Supply only thermostat switch with knob suitable for compressor of water cooler 40/80 capacity complete all as specified and directedMake : Godrej / Renutrol/Anpurna/Whirlpool or equivalent as approved by GE. |
| 52 | Supply only starting Capacitor 60 to 80 MFD, 230V, 50Hz suitable for compressor of water cooler 40/80 capacity complete all as specified and directed by Engineer -in-Charge.Make: Usha/Asian/Brite/Epcos/Dipcon/Concap or equivalent as approved by GE. |
| 53 | Supply only over load Protector with relay box type suitable for compressor of water cooler 40/80 capacity complete all as specified and directed Make Hitachi/Anupurna/whirlpool or equivalent as approved by GE. |
| 54 | Supply only condenser Blower fan blade suitable for 40/80 capacity water cooler or suitable for 1/10HP & 1/35 HP fan motor only including nuts/bolts complete all as specified and directed |
| 55 | Supply and repalcement of Self closing water tap 15 mm dia chromium plated, cast copper alloy, inner/outer thread as per sample for water cooler 40/80 capacity complete all as specified and directed by Engineer -in-Charge. |
| 56 | Supply on top cover made of steel body suitable for 40/80capacity water cooler complete all as specifed and directed by Engineer-in-Chare. |
| 57 | RefrigeratorDismantling and taking out Refrigerator of any type & capacity or make, including dismantling cleaning, replacement of necessary new spares/items, brazing/ gas charging & testing on load and back after repairs, re-installing in its original position, making all required connections and commissioning complete all as specified and directed.Note :- Spares parts will be measured and paid separately. |
| 58 | Supply only refrigerant gas F-22/ R-22/ R-410A/ R-134(a) as per existing for regrigerator of capacity up to 320 Ltr all as specified and directed by Engineer-in-Charge. |
| 59 | Supply only Hermitically sealed compressor unit comprising of the compressor coupled with inbuilt AC single phase 230V motor and other standard compressor accessories complete for Refregerator 180/ 215 ltrs capacity. Make - Kirloskar/Godrej/LG/Tecumseh or equivalent as approved by GE |
| 60 | Supply only Hermitically sealed compressor unit comprising of the compressor coupled with inbuilt AC single phase 230V motor and other standard compressor accessories complete for Refregerator 258/320 ltrs capacity. Make - Kirloskar/Godrej/LG/Tecumseh or equivalent as approved by GE |
| 61 | Supply only Box type relay suitable for any make and any capacity Refrigerator as per existing complete |
| 62 | Supply only thermostat auto defrost type suitable for any make and any capacity Refrigerator as per existing complete all as specified and directed by Engineer -in-Charge.Make:Danfos/Ind Foss / Renutrol or equivalent as approved by GE. |
| 63 | Supply only Drier 1/4 size suitable for any make and any capacity Refrigerator as per existing complete all as specified and directed by Engineer -in-Charge. |
| 64 | Supply only Cooling coil suitable for any make and any capacity Refrigerator as per existing complete |
| 65 | Supply only Condenser suitable for any make and any capacity Refrigerator as per existing complete |
| 66 | Supply only Copper capillary Tube size of 1/4 inch outer dia suitable for any make and any capacity Refrigerator as per existing complete |
| 67 | Supply only Copper tubing of size 5/16 inch dia suitable for any make and any capacity Refrigerator as per existing complete |
| 68 | Supply only Magnetic door gasket suitable for any make and any capacity Refrigerator as per existing complete |
| 69 | Supply only Ice tray suitable for any make and any capacity Refrigerator as per existing complete |
| 70 | Supply only Vegetable tray setincluding front door inner trays suitable for any make and any capacity Refrigerator as per existing complete |
| 71 | Supply only Pigmy lamp 15W suitable for any make and any capacity Refrigerator as per existing complete |
| 72 | Supply only Fan Motor suitable for any make and any capacity Refrigerator as per existing complete |
| 73 | Air ConditionerM&L for servicing of Window/Split Air conditioning of capacity upto 2.0TR including air Filter Cleaning, washing inner and outer condernser (indoor unit & outdoor) with pressure pump and chemical, condenser and evaporator coil cleaning, checking all type of relay, circuit board, charging of refrigerant gas if reqd complete all as specified and directedNote:- (i) Petty stores such as insulation tape, screws, small pieces of wires, shall be provided by the Contractor without any extra cost to the department. (ii) Gas shall be measured and paid seperately under respective item of BOQ as suppy only |
| 74 | Dismantling and taking out window type air conditioner of capacity 1.5/2 TR, transporting to the nearest workshop for repairing,incl dismantling, cleaning, replacement of necessary new spare parts as reqd, tracing leakage by injecting nitrogen gas upto 300 PSi, rectifying leaking spots/joints with gas welding/brazing including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system, testing on load and back after repairs, re-installing in its original position, making all required connections and commissioning complete all as specified and directed.Note : Spare parts will be measured and paid seperately as supply only. |
| 75 | Dismantling and taking out split type air conditioner of capacity 1.5/2 TR, incl dismantling, cleaning, replacement of necessary new spare parts as reqd, tracing leakage by injecting nitrogen gas upto 300 PSi, rectifying leaking spots/joints with gas welding/brazing including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system, testing on load and back after repairs, re-installing in its original position, making all required connections and commissioning complete all as specified and directed.Note : Spare parts will be measured and paid seperately as supply only. |
| 76 | Supply only refrigerant gas F-22/ R-22/ R-410A/ R-134(a) as per existing for air conditioner of capacity 1.5 TRall as specified and directed by Engineer-in-Charge. |
| 77 | Supply only refrigerant gas F-22/ R-22/ R-410A/ R-134(a) as per existing for air conditioner of capacity 2.0 TR all as specified and directed by Engineer-in-Charge. |
| 78 | Supply only Hermitically sealed compressor unit, copper wound, comprising of the compressor coupled with inbuilt AC single phase 230V motor and other standard compressor accessories complete for window type / split type air conditioner of 1.5 Ton capacity any make as per existing compressor complete all as specified and directed.Make :Tecumesh /Godrej/ Kirloskar / LG / Voltas or equivalent as approved by GE. |
| 79 | Supply only Hermitically sealed compressor unit, copper wound, comprising of the compressor coupled with inbuilt AC single phase 230V motor and other standard compressor accessories complete for split /window type air conditioner of 2 Ton capacity any make as per existing compressor complete all as specified and directed.Make :Tecumesh /Godrej/ Kirloskar / LG / Voltas or equivalent as approved by GE. |
| 80 | Supply only PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC and 1.5/2.0 split type capacity Air Conditioner complete all as specified and directed by Engineer in Charge.Make : Voltas/Carrier/ Hitachi /Blue star as approved by GE. |
| 81 | Supply only over load relay suitable for 1.5/2.0 Ton AC complete all as specified and directed by Engineer in Charge.Make : Renutrol/ Indofos / Kelvinator or equivalent as approved by GE. |
| 82 | Supply only thermostat switch with knob suitable for AC of any capacity complete all as specified and directed by Engineer in Charge.Make : Renutrol/ Indofos / Kelvinator or equivalent as approved by GE. |
| 83 | Supply only starting capacitor of capacity 40-60 MFD complete all as specified and directed by Engineer in ChargeMake:Universal/Dipcon/Usha/Epcos/Brite or equivalent as approved by GE. |
| 84 | Supply only Copper capillary Tube of any size suitable for 1.5/2.0 Ton Capacity AC complete all as specified and directed by Engineer in Charge. |
| 85 | Supply only PVC Front gril suitable for 1.5/2.0 Ton window type AC of any Make or model as per existing complete all as specified and directed by Engineer in Charge. |
| 86 | Supply only electric blower motor double shaft suitable for any make / model / capacity AC complete all as specified and directed by Engineer in Charge.Make : Renutrol/ Indofos / Kelvinator or equivalent as approved by GE. |
| 87 | Supply only conderser fan motor suitable for any make/model upto 2.0TR AC capacity with single shaft / double shaft complete all as specified and directed by Engineer in Charge.Make : Renutrol/ Indofos / Kelvinator or equivalent as approved by GE. |
| 88 | Supply only plastic fan blade suitable for any make/model/ capacity for split type AC complete |
| 89 | Supply only copper cooling Coil suitable for 1.5/2.0 Ton Capacity AC complete all as specified and directed by Engineer in Charge.Make : Renutrol/ Indofos / Kelvinator or equivalent as approved by GE. |
| 90 | Supply only Copper Condenser to be install in split AC outdoor unit suitable for upto 2 TR to be fitted in outdoor unit of air conditioner complete |
| 91 | Supply and fix in replacement voltage stablizer for automatic operation, single phase naturally air cooled copper wound indoor type & designed for input variation betwwen 170V to 250V with output voltage 230V with accuracy +-2.5 % and capacity of 5KVA. Note:- Old Voltage stablizer will be deposited to MES store yard. |
| 92 | Note:- (i) Contractor will attend complaints related to AC, Water cooler, Refrigerator and rectify with in 48 Hrs. If in case of failure to attend and rectify within 48 Hrs, a panelty will be imposed @ 500/ day per complaint till the complaint rectified.(ii)The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule \"A\"/BOQ |