| 1 | Taking downframe or Chowkhats (w/o taking off shutter from the frame ) of any description notexc. 1.50 Sqm and making surface good with CM 1:4 each complete all as specified and as directed. |
| 2 | S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube completeall asspecified and directed. |
| 3 | S&Ffactory made solid PVC Moulded Door shutter30mm thick with 2, 4 or 6 raised pannels design with 2mm thick Moulded PVC Sheet on front faceand 2mm plain colour PVC sheet on back face of particle board core as per specification & drawing completeall asspecified and directed. |
| 4 | Taking downframe or Chowkhats (w/o taking off shutter from the frame) of any description exc. 1.50 Sqm and not exc. 4.00 Sqm each incl necessary repair to opening with CM 1:4 complete all as specifiedand directed. |
| 5 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x100 /65x125mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibbers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners not paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extrapayment on this account shall be made. |
| 6 | S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 7 | S&F for Butt hinges of stainless steel 100mm size Heavy type complete all as specified and directed. |
| 8 | S&F for 150mm long stainless steel handles, fancy type, fabricated type. complete all as specified and directed. |
| 9 | S&F for 200 mm stainless steel, barrel tower bolts of extruded section and fixed complete all as specified anddirected. |
| 10 | S&F for Brass Mortice lock, vertical type, size 100mm 4 levers vertical with fancy handle (as decided by EIC) complete all as specified and directed. |
| 11 | S&Fin Door closer hydraulically regulated Aluminium (Die cast) body design No-3 universal type, suitable for door shutter of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed. Complete all as specified and directed. |
| 12 | S&F fordoor stopper of of brass body and tongue with hard drawn steel spring, (140mm size),complete all as specified and directed. |
| 13 | Taking down cementplaster of any description on brick or concrete surfaces of walls or ceilingetc incl. Raking out joints , hacking for key and scrubbing down with water complete all as specified and directed. |
| 14 | M&L for 15 mm thick rendering ofcement mortar 1:6, on brick work or concrete surfaces on wall and finished the surface even and smooth all as specified and directed. |
| 15 | M&L for 15 mm thick rendering ofcement mortar 1:4, on brick work or concrete surfaces on wall and finished the surface even and smooth all as specified and directed. |
| 16 | M&L for 5 mm thick rendering with cement mortar CM 1:3, on concrete surfaces as on ceiling, soffit of stair case, chhajjas facia etc including cement slurry etcfinished the surface even and smooth all as specified and directed. |
| 17 | M/L for preparation of new plastered surface of walls and applying two coats of OBD over chalk whitening complete all as specifiedand directed. |
| 18 | M&L for preparation ofnewlyplastered or unplaster surface and applying two coats of OBD on ceiling complete all as specified and directed. |
| 19 | M & L for preparation of new surfaces of walland applying one coats of cement based paint complete all as specified and directed. |
| 20 | M&L complete removal of existing treatment of walls and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. Two or more coats on plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smoothcompleteall as specified and directed. |
| 21 | M&L complete removal and scraping of existing treatment of walls and applying one coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 22 | M&L complete removal and scraping of existing treatment on ceillingand applying two coats of oil bound distemper over a coat of primer all as specified and directed. |
| 23 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specifiedand directed. |
| 24 | M&L for 25mm thick PCC 1:2:4 type B-1(using 20mm graded stone aggregate), as in sub base to the tile flooring complete all as specified and directed. |
| 25 | M&L non skid ceramic coloured printed tiles 7 to 8 mm thick(square/rectangular) area of each tiles exc 0.11 sqm but n. exc 0.18 sqm, in floors or dado etc set and jointed in neat cement slurry and pointed in coloured cement to match over 15 mm thick screed bed or bedding layer in cm (1:4) complete all as specified and directed. |
| 26 | M&L forvitrified tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floorsetc, set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over 15 mm th screed in cement mortar 1:4 complete all as specified and as directed. |
| 27 | M&L forVitrified Ceramic tiles light shade/dark shade /double charge/ ultracharged 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over 15 mm th screed in cement mortar 1:6 complete all as specified and directed. |
| 28 | M&L Glazed printed/ coloured ceramic tiles in vertical surface 350mmx 250mmx 7 mm/ 450mmX 350mmX 7mm/450mmX 300mmX 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick rendering in cement mortar 1:4 complete all as specifiedand directed. |
| 29 | M & L for 600mm x 600 mm x16 mm thick heavy duty non skid vitrified tiles in floor/skirting set and jointed in neatcement slurry and pointed in white or coloured cement to match etc over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 30 | Dismantling water tank and removing to storeexceding 250 but n.exc 500 ltrs complete all as specifed and directed. |
| 31 | S&F for rotational moulded polyethylene water storage tanks of 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including 20mm dia HD polythene float (ball) and epoxy coated aluminium rod (fly nut) screwed for iron pipe or brass ferrule complete all as specifed and directed. |
| 32 | Dismantling water tank and removing to storeexeeding 500 but n.exc 1000 ltrs complete all as specifed and directed. |
| 33 | S&F for rotational moulded polyethylene water storage tanks of 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including 20mm dia HD polythene float (ball) and epoxy coated aluminium rod (fly nut) screwed for iron pipe or brass ferrule complete all as specifed and directed. |
| 34 | Demolition ofwall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/ slabs/ blankets/board fixed in aluminum door or partition, any thickness, including cover fillets & framed work if necessary complete all as specified and directed. |
| 35 | S&F 5 mm thick ACPwall cladding sheet in colour as directed by Engr-in-charge fixed on MS frame . The size of each panel not exc 1.5sqm. MS frame to be fixed on walls, chajja and fasad with Min 08 Nos GI fastener 5\" long per 1.5 sqm, including all necessary repairing work as reqd, two coat of synthetic enamel paint over one coat of red oxide primer, including weather sealing sealent, masking tape, including cutting of V groves to fixing moulded ACP sheet self-tapping screw complete all as specified and directed by Engineer-in-Charge.Note:-1.Work to be carried out upto four storey bldg with MS scaffolding not bamboo.2. MS frame should be fixed on wall after painting. |
| 36 | S & F in \"E\" board(Design: LACK & hill) : 605x605x4 mm thick, white pre laminated set embossed reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped galvanized iron imposed grid with 24 mm wide T-section exposed flanges which shall be power coated white. The frame work shall be comprise of main runner made from 0.33 mm thickgalvanised steel sheet and of size 24 mm X32mmX300 mm board spaced at 120 mm maximum center to center, hangers of GI wire4 mm dia to be fixed by approved rawal plug level and fasteners and screws etc.,The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall , flushing fitting of 1200 mm longer cross tee(with double stitching) to be interlocked between main runners at 600 mm center to center from 1200X600 mm modules cross tee longer than 600 mm to be supported independently . 600mm long cross tee centrally between the 1200 mm cross tee(with double stitching) to be interlocked between main runners at 600 mm center to center from 1200X600 mm modules cross Tee longer than 600 mm to be supported independently . The perimeter wall angle shall be 0.45 mm thick GS sheet of size 19 mm X 19 mm and 300 mm long of white colour all as per manufacturer\"s instructions complete all as specified and directed by Engr-In-Charge. |
| 37 | S&F for 10-15mm thick exterior PVC wall cladding (Jalli) sheet of medium denasity in colour white or as directed by Engr-in-charge with compterised numerical control (CNC cutting) as directed, fixed on MS frame. The size of each panel not exc 1.5sqm. MS frame to be fixed on walls, chajja and fasad with GI fastener 5\" long per 1.5 sqm, including all necessary repairing work as reqd, two coat of synthetic enamel paint over one coat of red oxide primer, including weather sealing sealant, masking tape, including cutting of V groves to fixing molded PVC sheet with S/S self-tapping screw complete all as specified and directed by Engineer-in-Charge.Note:-1.Work to be carried out up to four story bldg with MS scaffolding not bamboo. 2. MS frame should be fixed on wall after painting. |
| 38 | M&L for10mm thick plaster of Paris ceiling (Gypsum anhydrous) to sunk or raised moulding to flat surface overmetal frame work inclreinforced with G.I. wire mesh & Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre & Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long all as specified and directed.Note Rates includes for taking down electrical fitting and refixing the same if required complete all as specified and directed. |
| 39 | S & F in fixing false ceiling at all heights with GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of Size 595x595 mm, semi perforated 12mm thick micro regular edged of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non-combustible as per BS 476 (part 4) - 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross - T of size 15x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanized iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 40 | Supply and fixingin position wall panelling at all heights (fire retardant and sound absorbent) with GRG ( Glass Fibre Reinforced Gypsum) panels/tiles of10 mm thick fully perforated suitable for acoustic purpose of size 595 x 595 mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 99%, NRC 0.70 to 0.85 as per IS 8225:1987, Non combustible as per BS 476 (Part 4)-1970 and light Reflectance of 75% to 85% (Minimum), comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanising @ 120 grams per square metre including both sides) i.e vertical studs of size 48 x 34 x 36 mm are placed at 600 mm centre to centre in a floor and ceiling channel section ofnickel coated size 50 x 32 mm fixed to the floor and ceiling at 600 centres using 12 mm dia, 50 mm long wedge type expanded zinc alloy dash fasteners with 10 mm bolt. The same channel is then to be fixed in horizontal direction at 600 centre to centre so as to form a grid of 600 x 600 mm. Glass wool of 50 mm thickness is then to be inserted in the slots and finally GRG ( Glass Reinforced Gypsum) non combustible panels/tiles are to be screw fixed with self tapping pan head nickle coated mild steel screws of size 13 x 3.2 mm on this grid leaving an even groove of 1 mm between the panels. The joint between the panels are to be duly jointed and finished using recommended jointing compound and fibre joint tape roll 50 mmm wide ( 90 meter) roll and two coats of primer suitable for panelling as per manufacturer\"s specifications as per direction of Engineer-in-charge all complete. |
| 41 | M&L for PVC /wpc profile for wall paneling of size 23cm wide, 8mm over all thick and 01mm wall thickness fixed with screw to mild square tubular steel frame work mad e out of MS Hollowsection of size 25mm x 15mm x 2mm spacing 01 meter on both side frame work shall be fixed in wall with the help rawl plug and required length of screws and MS work shall painted with one coat of Red oxide primer for wall panelling,complete all as specified and directed . |
| 42 | S&F in repair pvc bib taps of 15 mm borecomplete all as specified and directed. |
| 43 | Taking down or up steel water tubing and connections including cleaning for re-fixing/ credit of 15 mm borecomplete all as specified and directed. |
| 44 | Taking down or up steel water tubing and connections including cleaning for re-fixing/ credit of 20 mm borecomplete all as specified and directed. |
| 45 | S & F steel water tubing, galvanised,medium grade, ISI marked with all fittings andfixed on walls and ceilingsor laid in floors bore of pipe 15 mm complete all as specified and directed. |
| 46 | S & F steel water tubing, galvanised,medium grade, ISI marked with all fittings andfixed on walls and ceilingsor laid in floors bore of pipe 20 mm complete all as specified and directed. |
| 47 | Repair of automatic sensor glass door its motion motors or safety sensor or all mechanical part(Sliding door (dorma xl-c4125,150mmheight 4 mtr (aprox),all specified and as per amnufacturer instructions or as directed by engineer in charge . NOTE: Rates including visting and inspection charges |
| 48 | S&Fin repairs HPL or HDF board modular cubical for toilets of size 1.2 m x1.2m / 1.2 m x1.05m or as per site requirementwith openabledoors, hight of cubicals upto 2.1mtr,thickness of board shall be 10mm, density od board shall be 1.45gm/cm cu. , including with most extensively stainless frame for complete cubical and hardware along with standard adjustable foot, stainless steel top rail for providing extra lengthcomplete in all respect.Note :- Rate includes hardware like hinge, locks , door knobs, coat hooks, tower bolt , handles and as per manufacturer instruction |
| 49 | Dismantling of Stone slabs laid, bedded and pointed in any mortar complete all as specified and directed. |
| 50 | M&L for screed bed or bedding layer of mortar 20 mm thick in CM 1:4for laying floor finishescomplete all as specified and directed. |
| 51 | M & Lfor machine cut kota stone slab flooring 20-22 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingto achieve mirror polish complete all as specified and directed. |
| 52 | Dismantling plain /corrugated steel sheeting any gauge thick ness including Nainital and similar pattern complete all as specified and directed. |
| 53 | S&F forfibre glass reinforced translucent plain decorative sheeting having thickness 3mm textured surface side lap fixed with coach screw and washer in roof wall chain link fencing etc cranked hook bolts complete all as specifed and directed. |
| 54 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 55 | S&F in repairs for powder coated (minimum thickness of powder coating 50 micron) aluminum anodized three track slinding window with two or more shutter with 5 mm thick plane glass, one shutter of stainless steel mosquito proofing with good quality bearing ,handle lock,etc rubber beading and glazing clips etc using following sections as given in \"JINDAL\" catlogue etc as specified as per manufacturer instructions with the following size, complete all as specified and directed by Engr-in-Charge.Note : (1)Glass and wire not measured and paid separately however cost of all other connected accessories deemed included in unit rate. (2) faces of windows jamb should be given fair finish before fixing the window as per requirement of site |
| 56 | S&F in repair vertical venetian blinds made out of nylon cloth of any clour 100mm wide strip as aprroved including hanging arrangement rollers etc complete all as specified and directed. |
| 57 | S and F in repair 12mm thick Toughned glass as in hinged doors, partitions, sliding doors, automatic doors and similar work of approved brand and manufactures, including cutting to shape, drilling holes required, including Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, complete all as specifiedand directed by Engr-in-Charge.Note:- Rate included all nessesry fitting and frame work for glass fitting, provision of top and bottom pivots, S/S handle, hinges, double action floor spring, stoppers etc. complete all as specifiedand directed. |
| 58 | M&L for dismantling loose concrete cover of RCC slab, ceiling , columns, beams,chajja, balconies, staircase and as direceted, roughening and cleaning concrete surfaceswith steel wire brushes, removing of rust from existing steel surfaces with rust removers of SIKKA restoff 100 applied two coast @0.15kg/Sqm per coat of steel surface and cleaning all rust with steel wire brush and washed with water and allowed to dry incl S&F welded fabric GI wire mesh or wire , size not less than 75 x 75 mm and 3 mm dia as reinforcement to concrete.After placing the additional re-inforcement, all concrete surfaces shall be throughly scurbbed with brushes, washed with water and allowed to dryto this surface , apply chenmical policrete admixture at the rate not less than 2% by weight of cement and providing minimum 30 mm thick (average thickness) guniting mix (using 1 part of oridinary poartland cement 53 grade and 2 parts of ghaggar sand mixed with adhesive/admixture at the rate as directed) with a pressure of 2.2 to 2.5 kg per sqm by guniting machine and surfaces finished even and fair including necessary padding, shuttering form work etc and finally applying 5 mm thick cement plaster in CM 1:3 complete all as specified and directed. |
| 59 | S&F in repair aluminium chequered grill of anodized sectionmesh100mmx100mm or80mmx80mm of 8/6/mm dia of bar fixed to frame with 20x20mm aluminium flat section with screw complete all as specified and as directed. |
| 60 | M&L in repair for 16-18mm thick granite slab on top of floor, stairs, or any plateformincluding cutting polishing rounding on edge etcmachine cut, bedded andjointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in CM 1:4. including grinding and polishing including demolition of existing slab complete all as specified and directed. |
| 61 | Demolition of concrete of any description and in any position not otherwise specifically provided for.complete all as specified and directed. |
| 62 | M&L cement concrete chequered tiles of size 300mm x 300mm x25 mm thick machine pressed tiles, set and jointed in neat cement slurry in floors with grey cement and no pigment over and including 15 mm thick screed bedding layer in CM 1:6 complete all as specified and directed. |
| 63 | M& L for 60 mm thick, M-35 grade machine pressed rubber form moulded precast interlocking concrete coloured (Red/yellow) paver block , in any shape and size with grey cement and pigment as approved confirming to IS 15658-2006 complete all as specified and directed. |
| 64 | M&L for75 mm thick Cement concrete1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub floors, sub bases , floors and pavings/ paver blocks etc. complete all as specified and directed. |
| 65 | M&Lspreading and levelling of sandaverage 25 mm thick below inter lockingpaver complete all as specified and directed. |
| 66 | M&L cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in roof kerb or mud stops rounded or chamfered on edge complete all as specified and directed. |
| 67 | S&F in repairsfactory made UPVC white colour casement (openable/sliding)window/Doors area made of extrudedprofiles with wall thickness of 2.0mm (+/0.2mm). Window profile with hollow section with multi chamber, frame (60mmx58mm),sash (60mmx73mm),T profile (One vertical length in between two shutters) (60mmx74mm) Glazing bead(35x20mm) will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware EPDM gasket 1.2 + -0.2 mm thick galvanized steel frame (28mmx21.5mm) sash (31mmx27.5mm)\"T\" profile (27mmx17mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners.Hardware : [ casementhandle made of zinc alloyed (while powder coated) Butt hinges, slider, rollar of zinc alloyed (white powder coated) transmission gear made of mild steel with multi point locking system)and 5mm thick glazing with selected quality glass. Note : Glass not measured and paid separately however cost of all other connected accessories deemed included in unit rate. Net opening will be measured for payment purpose. |
| 68 | Demolition of brick/concrete block walling, RR masonary in cement mortar including all quoins archas pillars etc and pre-cast block walling etc complete all as specifed and directed. |
| 69 | M & L for brick work with sub-class `B\" bricks old size, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 70 | M & Lforcompleteremovalofexistingrooftreatment (Mud puska, Cement Tiles, bricks or Old APP Roof treatment and vegetation from root) including bedding layer in cement mortar/Mud anddisposedfrom MoD landcomplete all as specified and directed. |
| 71 | M&L PCC 1:2:4type B1 (using 20mm graded stone aggregate) mixed withliquid water proofing compound as per manufacturer instruction oflaid 25 mm thickness as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smoothwithout using extra cement complete all as specified and directed. |
| 72 | M&L for five layer prefabricated atactic polypropylene polymer (APP) modified 3 mm thick membrane ( weight not less 3 kg/sqm) reinforced with 160 gms polestar non-woven fabric with scratched tool before finishing roof surface. When the concrete surface is still green, 10 mm thick 1:4 cement plaster shall be laid, the roof surface shall be thoroughly wire brushed washed dried up and cleaned of all foreign matter and dust prior to the application of primer on the dried surface, one coat of approved bituminous primer having density in the range of 0.87 to 0.89 / kg at 25 degree and viscosity of 70 to 160 CPS manufactured by the same manufacturer @ 0.40 litres/sqm shall be applied. APP membrane shall be laid on primed surfacetorch application method after allowing 24 hours of primer to dry. Laying of APP membrane shall be commenced at the lowest level and worked upto the crest. APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100 mm on longitudinal direction and 150mm on the transverse direction. All overlaps shall be bonded with bitumen primer and levelled by the heating the overlaps with butane torch. This treatment shall be done by theapproved authorized applicator. Guarantee of treatment shall be for 10 years. Thereafter APP membrane shall be painting with two coat of water proofing paint with aluminium finish.(ii) Independent testing of membrane for the approval technical parameters specified hereinafter shall be carried out the approved laboratories like National test house any other Govt approved laboratory having facilities for the testing of membrane. |
| 73 | S&F in repairs for white vitreous china battery based infrared sensor operated urinal of size 295mm x 325mm x 575 mm having water inlet from back side, including fixing to wall with suitable brackets and sensor all as per manufacturers specification and directioncomplete all as specified and as directed by the Engineer-in-Charge. (Make: Hindware - Flow with integrated sensor CAT No 60021/or equivalent.) |
| 74 | S&F in repair vitreous china wash basin white oval type size as directed by EICwhite in colour, fitted in counter platform of granite stone (Granite stone shall be measured separately) including waste coupling for WHB with long screwed and shanks and fly nuts, flanged end bedded in red lead and other end fixed, PVC waste pipe, 32mm dia ,medium grade, pipe with fittings fixed in wall connected to floor trap for drain out, completeall as specified.(Make:HINDWARE/PARRY WARE/CERA) Ist quality. |
| 75 | S&Fin repair Vitreous china coloured wash down water closet pan one pieces (Couple closet) with \"P\" or \"S\" trap, Soft close PVC seat cover and twin flushing cistern complete all as specified and as directed. |
| 76 | S & F in repair Aluminium door single leaf with anodized aluminium frame of section 62.5mm x 37mm x 2.5 mm thick, shutter with bottom & middle rail of section 112.50mm x 37mm x 2.5 mm thick and styles & top rail of section 83mm x 37mm x 2.5 mm thick with centrally locking arrangement with lock make of ‘GODREJ’ or ‘LINK’ 7 lever and self closing device with rebate includingjointingcleats, fixing of builders hardware fittings, necessary numbers of floor spring and glazing with 5.5 mm thick ordinary plain glass includingnecessary fittings, fixtures & aluminium snap beadsComplete all as specified and directed. |