| 1 | Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender documents & all corrigendum/amendments and general condition of contracts before entry/quoting the rates.Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading ofincorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender. |
| 2 | Supply and fixing Copper bus bar of LT panel any capacity as per existing size with suitable size and capacity insulators including taking down complete all as specified and directed. |
| 3 | Supply and fixing in repair aluminium bus bar of LT panel any capacity as per existing size with suitable size and capacity insulators including taking down complete all as specified and directed. |
| 4 | Supply and fixing in repair HRC fuse of capacity 400 amp complete all as specified and directed. |
| 5 | Supply and fixing in repair HRC fuse of capacity 125 to 250 amp complete all as specified and directed. |
| 6 | Supply and fixing in repair HRC fuse of capacity 63 to 100amp complete all as specified and directed. |
| 7 | Supply and fixing in repair HRC fuse holder and base of capacity 32 to 160amp complete all as specified and directed. |
| 8 | Supply and fixing in repair sprader link of capacity upto 400amp complete all as specified and directed. |
| 9 | Supply and fixing in repair extended rotary handle for MCCB of capacity upto 400 amp complete all as specified and directed. |
| 10 | Supply and fixing in repair direct rotary handle for MCCB of capacity upto 400 amp complete all as specified and directed. |
| 11 | Supply and fixing in repair multifunction meter accuracy class 1.0 suitable for 50-520 VAC with suitable CT ratio complete all as specified and directed. |
| 12 | Supply and fixing in repair 3ph ammeter with accuracy class 1.0 suitable for 50-520 VAC with suitable CT ratio complete all as specified and directed. |
| 13 | Supply and fixing in repair 3 Phase voltmeter with accuracy class 1.0 suitable for 50-520 VAC with suitable CT ratio complete all as specified and directed. |
| 14 | Supply, installation, testing and commissioning of out type double door LT distribution box made out of 3.15mm thick CRCA sheet out door type, CPRI approved manufacture totally enclosed weather dust and as per IS with front and rearopening suitable locking arrangement having copperbus bar strip size 40mm x10mm capacity for RYB and neutral and insulated with insulators,including connecting incoming and outgoing cables necessary PCC (1:3:6) in foundation and made out of 50 x 50 x 6mm angle iron grouted at groundabove 90cm from ground level comprising the following, complete all as specified and directed:-Incoming:(i) MCCB 250 Amp 4 pole 36 KA with thermal magnetic protection - 01 No.(ii) Digital multi functionMeter01- 500 Volt(iii) RYB Indicating lamps -03 Nos.(iv) CT\"s 100 /5 Amp - Set of threeOutgoing:(i) MCCB 125 Amp 4 pole 36 KA with thermal magnetic protection - 03 No. (01 Spare + 02 Working)(ii) MCCB 63 Amp 4 pole 25 KA with thermal magnetic protection - 01 Nos.Note:- Cost of necessary internal wiringfor meters, CTs, indication lamps,etc and rigid bus bar connections from bus bar to MCCB terminals connection bus to MCCB/MCB connections shall deemed to be included in the unit quoted rate. All the MCCBs should be connected through bus bar by using sprader link, minium 6 inch projection of CRCA sheet all around the periphery to safe gaurd the LT panel from Rain. |
| 15 | Supply, installation, testing and commissioning ofout type double door LT distribution box made out of3.15mm thick CRCA sheetout doortype, CPRI approved manufacture totally enclosed weather dust and vermin proof as per ISwith front and rearopening suitablelocking arrangement having copperbus bar strip size 40mm x10mmcapacity for RYB and neutral and insulated with insulators,including connecting incoming and outgoing cables necessary PCC (1:3:6) in foundation and made out of 50 x 50 x 6mm angle iron grouted at groundabove 90cm from ground level comprising the following, complete all as specified and directed:-Incoming:(i) MCCB 250 Amp 4 pole 36 KA with thermal magnetic protection - 01 No.(ii) Digital multi functionMeter01- 500 Volt(iii) RYB Indicating lamps -03 Nos.(iv) CT\"s 100 /5 Amp - Set of threeOutgoing:(i) MCCB 200 Amp 4 pole 36 KA with thermal magnetic protection - 01 No.(ii) MCCB 160 Amp 4 pole 36 KA with thermal magnetic protection - 01 No.(iii) MCCB 125 Amp 4 pole 36 KA with thermal magnetic protection - 02 Nos. (01 Spare + 01 Working)(iv) TPN MCB 63 Amp 4 pole 10 KA with thermal magnetic protection - 02 Nos.Note:- Cost of necessary internal wiringfor meters, CTs, indication lamps,etc and rigid bus bar connections from bus bar to MCCB terminals connection bus to MCCB/MCB connections shall deemed to be included in the unit quoted rate. All the MCCBs should be connected through bus bar by using sprader link, minium 6 inch projection of CRCA sheet all around the periphery to safe gaurd the LT panel from Rain. |
| 16 | M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to earth lead of 32x6 mm dia by means of nuts, bolts, check nuts & washers made of galvanised iron protection pipe light grade of 20 mm dia and watering pipe medium grade of 15 mm dia and filled alternate layer of charcoal or coke and salt , watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No 3 of SSR Part I of 2009 connected to earthing testpoint or as directed by Engr-in-charge all specified and indicated including necessary excavationand earth work in hard / dense soil complete all as directed by EIC.Note:- GI strip from Earth pit to panel will be included in the quoted rates |
| 17 | Supply and fixing copper bus bas of LT panel any capacity as per existing size with suitable size and capacity insulators including taking down complete all as specified and directed. |
| 18 | Supply and fixing aluminium bus bas of LT panel any capacity as per existing size with suitable size and capacity insulators including taking down complete all as specified and directed. |
| 19 | Supply, installation, testing and commissioning of out type double door LT distribution box made out of 3.15mm thick CRCA sheet out door type, CPRI approved manufacture totally enclosed weather dust and vermin proof as per ISwith front and rearopening suitable locking arrangement having copperbus bar strip size 40mm x10mm capacity for RYB and neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC (1:3:6) in foundation and made out of 50 x 50 x 6mm angle iron grouted at ground above 90cm from ground level comprising the following, complete all as specified and directed:-Incoming:(i) MCCB 250 Amp 4 pole 36 KA with thermal magnetic protection - 01 No.(ii) Digital multi functionMeter01 - 500 Volt(iii) RYB Indicating lamps - 03 Nos.(iv) CT\"s 100 /5 Amp - Set of threeOutgoing:(i) MCCB 125 Amp 4 pole 36 KA with thermal magnetic protection - 03 No. (01 Spare + 02 Working)(ii) MCCB 63 Amp 4 pole 25 KA with thermal magnetic protection - 01 Nos.(iii) MCB TPN 63 Amp 4 pole 25 KA with thermal magnetic protection - 02 Nos.Note:- Cost of necessary internal wiringfor meters, CTs, indication lamps,etc and rigid bus bar connections from bus bar to MCCB terminals connection bus to MCCB/MCB connections shall deemed to be included in the unit quoted rate. All the MCCBs should be connected through bus bar by using sprader link, minium 6 inch projection of CRCA sheet all around the periphery to safe gaurd the LT panel from Rain. |
| 20 | Supply, installation, testing and commissioning ofout type double door LT distribution box made out of3.15mm thick CRCA sheetout doortype, CPRI approved manufacture totally enclosed weather dust and vermin proof as per ISwith front and rearopening suitablelocking arrangement having copperbus bar strip size 40mm x10mmcapacity for RYB and neutral and insulated with insulators,including connecting incoming and outgoing cables necessary PCC (1:3:6) in foundation and made out of 50 x 50 x 6mm angle iron grouted at groundabove 90cm from ground level comprising the following, complete all as specified and directed:-Incoming:(i) MCCB 200 Amp 4 pole 36 KA with thermal magnetic protection - 01 No.(ii) Digital multi functionMeter01- 500 Volt(iii) RYB Indicating lamps -03 Nos.(iv) CT\"s 100 /5 Amp - Set of threeOutgoing:(i) MCCB 125 Amp 4 pole 36 KA with thermal magnetic protection - 02 No.(ii) MCCB 100 Amp 4 pole 36 KA with thermal magnetic protection - 01 No.(iii) TPN MCB 63 Amp 4 pole 25 KA with thermal magnetic protection - 01 Nos.Note: Cost of necessary internal wiringfor meters, CTs, indication lamps,etc and rigid bus bar connections from bus bar to MCCB terminals connection bus to MCCB/MCB connections shall deemed to be included in the unit quoted rate. All the MCCBs should be connected through bus bar by using sprader link, minium 6 inch projection of CRCA sheet all around the periphery to safe gaurd the LT panel from Rain. |
| 21 | Supply, installation, testing and commissioning ofout type double door LT distribution box made out of3.15mm thick CRCA sheetout doortype, CPRI approved manufacture totally enclosed weather dust and vermin proof as per ISwith front and rearopening suitablelocking arrangement having copperbus bar strip size 40mm x10mmcapacity for RYB and neutral and insulated with insulators,including connecting incoming and outgoing cables necessary PCC (1:3:6) in foundation and made out of 50 x 50 x 6mm angle iron grouted at groundabove 90cm from ground level comprising the following, complete all as specified and directed:-Incoming:(i) MCCB 200 Amp 4 pole 36 KA with thermal magnetic protection - 01 No.(ii) Digital multi functionMeter01- 500 Volt(iii) RYB Indicating lamps -03 Nos.(iv) CT\"s 100 /5 Amp - Set of threeOutgoing:(i) MCCB 100 Amp 4 pole 36 KA with thermal magnetic protection - 02 No.(ii) MCCB 63 Amp 4 pole 36 KA with thermal magnetic protection - 01 No.(iii)TPN MCB 63 Amp 4 pole 25 KA with thermal magnetic protection - 03 Nos.Note:- Cost of necessary internal wiringfor meters, CTs, indication lamps,etc and rigid bus bar connections from bus bar to MCCB terminals connection bus to MCCB/MCB connections shall deemed to be included in the unit quoted rate. All the MCCBs should be connected through bus bar by using sprader link, minium 6 inch projection of CRCA sheet all around the periphery to safe gaurd the LT panel from Rain. |
| 22 | Supply, installation, testing and commissioning ofout type double door LT distribution box made out of3.15mm thick CRCA sheetout doortype, CPRI approved manufacture totally enclosed weather dust and vermin proof as per ISwith front and rearopening suitablelocking arrangement having copperbus bar strip size 40mm x10mmcapacity for RYB and neutral and insulated with insulators,including connecting incoming and outgoing cables necessary PCC (1:3:6) in foundation and made out of 50 x 50 x 6mm angle iron grouted at groundabove 90cm from ground level comprising the following, complete all as specified and directed:-Incoming:(i) MCCB 250 Amp 4 pole 36 KA with thermal magnetic protection - 01 No.(ii) Digital multi functionMeter01- 500 Volt(iii) RYB Indicating lamps -03 Nos.(iv) CT\"s 100 /5 Amp - Set of threeOutgoing:(i) MCCB 160 Amp 4 pole 36 KA with thermal magnetic protection - 02 No.(ii) MCCB 63 Amp 4 pole 36 KA with thermal magnetic protection - 02 No.(iii)TPN MCB 63 Amp 4 pole 25 KA with thermal magnetic protection - 02 Nos.Note:- Cost of necessary internal wiringfor meters, CTs, indication lamps,etc and rigid bus bar connections from bus bar to MCCB terminals connection bus to MCCB/MCB connections shall deemed to be included in the unit quoted rate. All the MCCBs should be connected through bus bar by using sprader link, minium 6 inch projection of CRCA sheet all around the periphery to safe gaurd the LT panel from Rain. |
| 23 | Supply, installation, testing and commissioning ofout type double door LT distribution box made out of 3.15mm thick CRCA sheet out door type, CPRI approved manufacture totally enclosed weather dust and vermin proof as per IS with front and rear opening suitable locking arrangement having copperbus bar strip size 40mm x10mmcapacity for RYB and neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC (1:3:6) in foundation and made out of 50 x 50 x 6mm angle iron grouted at ground above 90cm from ground level comprising the following, complete all as specified and directed:-Incoming:(i) MCCB 250 Amp 4 pole 36 KA with thermal magnetic protection - 01 No.(ii) Digital multi function Meter01- 500 Volt(iii) RYB Indicating lamps - 03 Nos.(iv) CT\"s 100/5 Amp - Set of threeOutgoing:(i) MCCB 200 Amp 4 pole 36 KA with thermal magnetic protection - 01 No.(ii) MCCB 160 Amp 4 pole 36 KA with thermal magnetic protection - 02 No.(iii)TPN MCB 63 Amp 4 pole 25 KA with thermal magnetic protection - 02 Nos.Note:- Cost of necessary internal wiring for meters, CTs, indication lamps,etc and rigid bus bar connections from bus bar to MCCB terminals connection bus to MCCB/MCB connections shall deemed to be included in the unit quoted rate. All the MCCBs should be connected through bus bar by using sprader link, minium 6 inch projection of CRCA sheet all around the periphery to safe gaurd the LT panel from Rain. |
| 24 | Supply, fabricating, installing, testing and commissioning of outdoor type LT bus bar box, factory made, of size not less than 900mm (L) x 900mm (B) x 450mm (D) factory fabricated, cubical panel, floor mounted double door, dust and vermin proof CPRI approved made out of 3.15 mm thick CRCA sheet mounted on 40 x 40 x 5mm angle iron supports at the base duly painted with synthetic enamel paint (spray painting) over and including priming coat and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply, including suitable size cable glands, lugs etc, in proper arrangement for ventilation, including taking down of old unserviceable bus bar box, complete all as specified and directed |
| 25 | Fixing & Erection of pole mounted solar light fitting 90 watt (pole height appx 3.00 metres long)including GI Base Plate, base foundation ofPole (appx 0.6x0.6x0.6m) by using PCC (1:3:6) (40mm graded aggregate) andCoping (1:2:4) (20mm graded aggregate) (appx 0.45 x 0.45 x 0.45m) complete all as specified and as directed.NOTE:-1. Earthwork, Cement Concrete, etc. included in unit quoted rate2. The solar light alongwith pole will be issued by department |
| 26 | M&L for painting of LT panel/ Bus bas panelby scraping and removing old paints, rust, etc. by applying two coat of synthetic enamel paint of approved colour (approx surface area of electric panel 24 sqmtr) complete all as specified and as directed. |