| 1 | Demolition of reinforced cement concrete as in Roofs, floors (other than ground floors), beams staircases, landing, chajjas and similar suspended work. Complete all as specified and directed. |
| 2 | Demolition of brickwork masonry built in cement mortar including all quoins, arches pillars etc. Complete all as specified and directed. |
| 3 | Taking down of Aluminium window/ ventilator of any size. Complete all as specified and directed. |
| 4 | Taking down chowkhats or frames as in doors exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frame). Complete all as specified and directed. |
| 5 | Taking down CP Bib tap/ Mixture tap/ Shower rose/ Angle cock etc. Complete all as specified and directed. |
| 6 | Dismantling water storage tank 1000 Ltrs capacity. Complete all as specified and directed. |
| 7 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 15 mm dia. Complete all as specified and directed. |
| 8 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 25 mm dia. Complete all as specified and directed. |
| 9 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness. Complete all as specified and directed. |
| 10 | Removal debris obtained from demolition of bldg upto distance of 5 km outside MD Land. Complete all as specified and directed. |
| 11 | Dismantling wrought iron or mild steel work of any description specifically provided for gates, staircase railings, framed truss etc Complete all as specified and directed. |
| 12 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades toE/M Store Yard at INS Hamla for depositing from site Complete all as specified and directed. |
| 13 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 14 | Taking downold unserviceable sub main wiring along with casing caping / conduit fixed on wall surface of any type Complete all as specified and directed. |
| 15 | Taking down carefully existing unserviceable main switch /cutout /DBs of any type, capacity / description and removing materials from site Complete all as specified and directed. |
| 16 | Taking up or down PPR/ UPVC32mm or galvanised steel tubing 25 mm bore (dia) including connections and fittings from trenches, walls, floors, etc Complete all as specified and directed. |
| 17 | Taking up or downPPR/ UPVC50 mm/ 63 mmor galvanised steel tubing 40 or 50 mm bore (dia) including connections and fittings from trenches, walls, floors, etc Complete all as specified and directed. |
| 18 | Making connection of PP-R distribution branch with PP-R main of following sizes 16 to 40 mmby providing and fixing tee including cutting and making fusion joint etc. Complete all as specified and directed. |
| 19 | Supply and fixing PP-R Gate valves40 mm (brass insert) as per requirement of the site Complete all as specified and directed. |
| 20 | Taking down / out unserviceable UG Cables of any cross sectional Area , connections and joints including pipes as in cable protection fixed on surface of walls segreating serviceable cables etc., and keep in safe custody for reuse or carrying to deposit in EM store Yard at INS Hamla complete all as specified and as directed. |
| 21 | Dismantling of Asbestos cement (Corrugated, semicorrugated etc) sheets in roof coverings. Complete all as specified and directed. |
| 22 | Taking down chowkhats or frames as in window/ ventilators with shutters not exc. 1.5 sq. m each (without taking off shutters from the frame). Complete all as specified and directed. |
| 23 | Taking up or down PPR/ UPVCgalvanised steel tubing 15 mm bore (dia) including connections and fittings from trenches, walls, floors, etc complete all as specified and as directed. |
| 24 | Labour for Screwing existing steel tubing for alterations or additions steel tubing 15 mm bore (dia) (or lengthening screw on pipe to form connector) complete all as specified and as directed. |
| 25 | Supply and fixing PVC perforated caps 15 mm bore (dia) screwed to ends of puff or vent pipes complete all as specified and as directed. |
| 26 | M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed. |
| 27 | M & L for submain wiring with approved colour coding as per IS with four single core PVC insulated FRLS multistranded copper conductor cable of size 25 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 25 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed.Note- Five run of 25 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed. |
| 28 | Supply and fixing amp rating 240V, 10KA \"C\" curve, IP 20 protected terminals, miniature circuit breaker (MCB) SP 5 To 32 AMP current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 29 | S & F sheet metal enclosure suitable for Flush Mounting and Surface Mounting, MCB DB with 250 Amps rated bus bar for each phase, Fully insulated & shrouded 2 Neutral bars, 2Earthbar and Cable ties for Cable management, &With provision for DPX³ 250 MCCB as incomer and SP/TP MCB\"s as outgoing, 415Volts, IP 43 - #IK 09 with metal double door & magnetic locking system includinginserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface &colour to wall Complete all as specified and directed. |
| 30 | (a) VTPN 4 Way. Make Legrand Cat No - 5077 58 or equivalent. |
| 31 | Supply and fixing DPX³ 160 MCCB with O/L & S/Cthermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 125 Amps. Make Legrand Cat No 4200 56 or Equivalent in L&T |
| 32 | Supply and fixing DPX³ 160 MCCB with O/L & S/Cthermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 160 AmpsMake Legrand Cat No 4200 57 or Equivalent in L&T |
| 33 | Supply and fixing 6A+16A Three pin socket with indicator and big switch, Cat No -SKG-GLD-GL16A1GBIS including 86 Size junction box for mounting switch socket combinationcat No SAC-WHT-JBX1 Make- Jaquar or equivalentcomplete all as specified and as directed. |
| 34 | Supply and fixing Medium duty SS 304 CABLE PERFORATED TRAYS, rust proof,in standard length of 2.5 Mtr, thickness - 3.0 mm, and height of tray 50mm complete with side SS couplers plates to connect cable trays with each other, SS couplers cable tray bends, andsupporting accessories of GI (Galvanized Iron) Threaded Rods, Fasteners, withnuts, bolts, washers etc for fixing cable tray on walls or hanging with ceilings all as specified and as directed complete width of |
| 35 | (a) Cable Tray 150mm |
| 36 | Note:- Supporting hanging/ wall fixing accesssories, couplersshall be fixed atminimum length01 Mtr spanand will be measured as one length along with cable tray. Rate quoted shall deemed to be included in the unit rate quoted. |
| 37 | Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/ 80 Ltrs with inbuilt water cartgidge filters complete all as specified and as directed. Make: Blue star, Voltas or Equivalent |
| 38 | Supply and fix, installation of 3 KVA voltage stabilizer for automatic operation with copper wound coil, single phase naturally air cooled indoor type wall mounted with electronic time delay relay, designed for input variation between 170 volt to 250 volts with out put voltage at 230 volt with accuracy of + 2.5% suitable for above water cooler complete all as specified and as directed. |
| 39 | Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or infloors etc., any type of pipe size |
| 40 | (a) 25 mm dia |
| 41 | (b) 32 mm dia |
| 42 | (c) 50 mm dia |
| 43 | Cutting existing steel tubing for alterations or additions (Each cut measured) 40 or 50 bore of pipe |
| 44 | Supplied and fixed Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed 15mm bore dia of pipe |
| 45 | Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable etc and getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 46 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. |
| 47 | Removing Surplus excavatedSoil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, Complete all as specified and directed. |
| 48 | Material and labour forcable route marker made of Pre-cast cement concrete block masonry Type C1 1:3:6 (20mm graded aggregrate)with solid blocks, exc. 10 cm in width and settingin cement concrete mortar 1:6, includingembosing DANGER/ LT CABLE / MESon cable route marker and properly painting with approved colour,size of cable route marker 900x300x100mm completeburied in ground for a depth of 45 cm & necessary earth work. Complete all as specified and directed. |
| 49 | Supply and layingHDPE Pipe PN 10 Size 100mm laid in trenches along with accessories such as couplerfor electrical applications as in cable protection pipe from physical damagecomplete all as specified and as directed. |
| 50 | Supply and layingHDPE Pipe PN 10 Size 65 mm laid in trenches along with accessories such as couplerfor electrical applications as in cable protection pipe from physical damagecomplete all as specified and as directed. |
| 51 | Supply and laying across road crossing reinforced concrete pipes, class NP2, laid and jointed complete with collars of size 250mm complete all as specified and as directed |
| 52 | Supply & laying of LTAluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip,Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 400 Sqmm 3½ Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clampsincluding Brass Cable Glands at termination end points Mild Steel Flat Iron Clampsof adequate size, etc. and Testing complete all as specified and as directed. |
| 53 | Supply and Laying of Aluminium HT Cables,11 kV (UE), of size 70 Sqmm 3½ CoreCore, Stranded Compacted Circular Aluminium Conductor, Conductor Screen with Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with Extruded Semi Conducting Compound in Combination with Copper Tape, Cores Laid Up, Innersheath of PVC, Galvanised Steel Flat Strip Armoured, & Overall PVC Sheathed Cable Conforming to IS 7098 (Part-2) 2011 with upto Date Amendments completelaid in Pipe / Ducts/ Trenches/ under Floor /Road including Testingand comissioning all as specified and as directed. |
| 54 | NOTE for Item No 46 & 47 : Earthworks, cable Protection pipe, cable traywill be measured and paid seperately under respective item of schedule. |
| 55 | Material and Labour Soling (or sub base) 150 mm spread thickness with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and directed. |
| 56 | M&L Cement Concrete Type B2-1:2:4 (40mm graded aggregate) as in Foundation filling and mass concretefor grounting of panel and making good disturbed road surfaces including necessary Formwork (as/if required) complete all as specified and as directed. |
| 57 | Supplied and fixed, Category 36 KA, Rated Current (A) - 320Amps, 4 Pole MCCB , Type -DPX³ 630 of Make- Legrand or equivalent as per existing fixed in panel board at sitewith thermal magnetic protection unit, O/L & S/C protection,Ics=100%Icu, complete all as specified and as directed |
| 58 | Design, supply, install, testing and commissioning of Factory made, indoor typepadestal mounted, totally enclosed, dust and vermin proof,power distribution system, LT cubical panel Board suitable for 500V, 3 phase, 4 wire, 50 Hz,of adequate size with double stud hinged door, front and rear openable along with locking arrangement duly fabricated out of Stainless Steel Sheet rust proof (outerbody and covers) & Inner body/ door covers of sheet not less then 2.0 mm thickness, & internal wiring complete with copper bus bar to be provided through out the length of the panel for incoming, outgoing feeders andelectric Meters accommodated in a modular multitier arrangement and interlocked to avoid paralleling, adequate size cable alley comprising and housed incompartments with the Accssories/Fixtures and Fittings mentionedhere-in-after including mounting LT panelon PCC Platform all round as recommended by OEM complete and setting aside old unserviceable LT Panel Board |
| 59 | The following accessories / Fittings and fixtures are requiredto be fitted in-housed in the LT Panel Board :-(A) INCOMING:(a) 500 Amps rated copper bus bar TPN duly insulated with coloured PVC Sleeve as per Standard Colour Code and rigidly mounted on Bakelite /DMC insulator Bus bar support (Square / round) insulators of suitable size and good insulation resistance .(i)MCCB 320 4 Pole 415 V 50 KA- 01 Nos Adjustable Thermal & Adjustable Magnetic (Main Incomer)(ii) Multi Function Meter Make L&T Cat No-WL440511OOOO-01(iii) Phase indicator lamps (RYB) - 01 set(B) OUTGOING:(i)MCCB 200 4 Pole 415 V 36 KA- 02 Nos (Adjustable Thermal & Adjustable Magnetic)(ii)MCCB 160 4 Pole 415 V 36 KA- 05 Nos(Adjustable Thermal & Adjustable Magnetic) |
| 60 | Material & labour for Earthing using galvanised iron earth plate electrode of size 60cm X 60cm X 6mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers including refilling with good earth as specified and electrode connections by using galvanised iron strip of size 32x6mm by means of bolts, nuts, check nuts and washers made of GI and provision of GI pipe medium grade 40 mm dia for protection of earthing lead and 20mm dia for watering arrangement including funnel, wire mesh, CI pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 5 of SSR Part-I2009. |
| 61 | Deduct Credit for Demolished/ Dismantled material Rs. (-) 0.00 (Minus) as listed in Schedule of CreditNote 1:- Tenderers will not quote against this item being a tentative amount to be considered to arrive at the \"Contract Sum\"Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items. |