| 1 | Supply and fix powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 2 | Supply and fix powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides withrequired EPDM rubber/ neoprene gasket etc.aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and as directed by Engineer-In-Charge. |
| 3 | Supply and fix 4.00 mm thick sheet glass, ordinary quality and glazingin square not exceeding 0.50 sqm in each panein aluminium joineryin each pane complete all as specified. |
| 4 | Supply and fix 18/19 mm thick veneered particle board, interior grade, solid core, with decorative face veneers both faces, fixed with screws complete all as specified. |
| 5 | Supply and fix collapsible steel gates, top hung,consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as directed. |
| 6 | Excavation in post holes (for similar holes) each not exceeding 0.5 CUM getting out soft/ loose soil, returning filling, in and ramming earth or broken mixed with earth around in layers not exceeding 25 cm watering and removing surplus soil to a distance not exceeding 50 m and making good surface in soft loose soil complete all as specified.Note: Returning filling and Removing of surplus soil are deemed to be included in this item. |
| 7 | Material and labour for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregates as in foundation, filling and mass concrete complete all as specified. |
| 8 | Supply and fix hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified. |
| 9 | Material and labourfor Mild steel deformed bars, 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for chainlink fencing and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified.Make: Any of as per Engineer-In-Chief branchs list of approved makes |
| 10 | Supply only M.S Galvanised chain link fencing any size or type. Note: (a)The sample only be approved by GE after physical check.(b) The contractor shall produce necessary test certificate for galvanised coating and without the same no payment shall be made to the contractor. |
| 11 | Fixing only chainlink fencing incl line wire any mesh size and type of any type of standard, rails, straining bolts etc. including provision of binding wire. |
| 12 | Supply and fix of galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, straining bolts at ends, staples or steel pins etc. complete all as specified. Note: The contractor shall produce necessary test certificate for galvanised coating and without the same no payment shall be made to the contractor. |
| 13 | Supply and fix mild steel screw bolts (machine made) of dia 5-10 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10 cm but not exc 15 cm long complete all as specified and directed. |
| 14 | Excavation in trenches not exc. 1.5 m wide not exc. 1.5 m in depth; for laying of cables not exc. 10 Sqm on plan and getting out , trimming sides, forming bottom surface to required level complete in hard/dense soil all as specified and as directed. |
| 15 | Material and labour for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 in damaged manholes, septic tank/ soak well etc. complete all as specified |
| 16 | Material and labour for 15 mm thick renderingin cement mortar 1:4 in two layers (10 mm +5 mm) on fair faces of brick wall or concrete surfaces, finished the surfaces even and smooth without using extra cement with using approved Liquid Water Proofing Compound on second layer (5 mm) as per manufacturer instruction complete all as specified. Note: Liquid Water Proofing Compound shall be measured and paid including this item |
| 17 | Material and labour for preparation of new and previously untreated steel or ironsurfaces of any description, not otherwise described exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over one coat ofred oxideprimer all as specified. |
| 18 | Material and labour for preparation of newly plastered surfaces of wall and applying two coats of cement based paint over a coat of chalk whitening complete all as directed. |
| 19 | Returning filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed. |
| 20 | Removing excavated materials (soils) not exc 50.00mtr and depositing where directed at a level not exc 1.50 mtr above the starting point in soil, complete all as specified and as directed. |
| 21 | Material and labour for cement concrete type C1, 1:3:6 (20 mm graded aggregate), rounded or chamfered on edges in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, coping kneelers, apex stones, bed plates, kerbs not provided for roof kerbs or mud stops, rounded or chamfered on edges, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including water proofing compound complete all as specified |
| 22 | Material and labour Reinforced cement concrete 1:1.5:3 type A1 using 20 mm graded crushed stone aggregates as in Columns, pillars, piers, posts and struts complete all as specified and directed. Note:-Reinforcement and form work shall be measured and paid including this item |
| 23 | Material and labour for reinforced cement concrete 1:1.5:3 type A1 using 20 mm graded crushed stone aggreagates as in foundation including rafters footings foundation beam plinth beam bases for column etc basement slab under reamed piles and mass concrete complete all as specified and directed. Note:Reinforcement and form work shall be measured and paid including this item |
| 24 | Material and labour for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing confirming to Fe-410-W Grade E-250 Quality-A complete all as specified.Note: All accessories and decorative members as per requirement as decided by Engineer-In-Chargeshall be included in this item |
| 25 | Material and labour for point wiring with 1.50 Sqmm PVC insulatedun sheatned multi stranded copper conductor cable (FRLSH) 1100 volts grade two single core conforming to IS-694-1990 and one run of continious earth wire with 1.50 Sqmm PVC insulated unsheatned stranded copper conductor cable (FRLSH) draw in and including heavy duty 20 mm dia PVCconduit(ISI marked) in concealed with all necessaryfittings and fixures and switch, socket, regulator, fan point, exhaust fan point etc. including making good disturbed surface with CM (1:4) to match with the existing surface complete all as specified for the following :- Note:-(a) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing.Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.(b) Quoted rates shall be deemed for conduit,cutting chases of wall, making good disturbed wall.(c) The metal flush box with modular cover plates with frame measured and paid separately.Make: Finolex(ISI Marked)/ Polycab(ISI Marked)/ Nicco (ISI Marked)/ Havells (ISI Marked)/ RR Cable(ISI Marked)/ KEI (ISI Marked) |
| 26 | One light/ fan/ exhaust fan/ bell point controlled by one nos, one way switch |
| 27 | One 5 pin 6 Amps switch socket outlet point controlled by one switch on independent board. |
| 28 | All as per Item No 25.00 but One 3 pin socket outlet. 15 amps, independent, with cables 2.50 sq. mm size complete all as specified. |
| 29 | Supply and fix Modular type Switch , flush type single pole one way 10 Amps 240V.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 30 | Supply and fix socket outlet modular type 2 module , 2/3 pin 6 Amps 240 V flush type.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 31 | Supply and fix Modular type Switch , flush type single pole one way 16 Amps 240V.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 32 | Supply and fix Modular socket outlet 2 module , 3 pin 6 to 16 Amps 240 V flush type . Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 33 | Supply and fix modular metal flush box with modular white cover plate with frame , 1 or 2 module complete all as specified.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 34 | Supply and fix modular metal flush box with modular white cover plate with frame , 3 module complete all as specified.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 35 | Supply and fix modular metal flush box with modular white cover plate with frame , 4 module complete all as specified.Make: L&T/ Legrand/ Havells/ Anchor/ Schneider/ Hager |
| 36 | Supply and fixing LED luminaire 600mm x 600mm square type 34 to 36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three flexible copper conductor cases of suitable size complete all as directed.Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minimum 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 37 | Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 6.00 Sqmm single core multistrand copper conductor cable (FRLSH), 1100 Volt grade alongwith single run of 6.00 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH) 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through minimum 25 mm PVC conduitcomplete all as specified.Note:- (a)PVC conduit in concealed including accessories shall be measured and paid including the item.(b) 2 Run of line conductor and 1 Run of earth continuity conductor shall be measured as one unit length.(c) Cable requireds for connection to MCBs/DBs shall be deemed to be included in the unit rate.(d) Rate shall be included for cutting, pinning in, making good to facings where required for pointing in cement mortar 1:3 and cutting chases for concealed conduit wiring and making good, and cutting not exceeding 10 cm girth.Make:Finolex(ISI Marked)/ Polycab(ISI Marked)/ Nicco (ISI Marked)/ Havells (ISI Marked)/ RR Cable(ISI Marked)/ KEI (ISI Marked) |
| 38 | Supply and fix as in replacement sheet metal enclosure MCB DB SPN with din rail 08 way 240 V (double door type) with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonry etc. and making good of disturbed surface to match with existing colour of wall complete all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GENote: (a) Quoted rates shall be deemed for brick wall / concrete wall cutting and making good as per existing surfaces. |
| 39 | Supply and fix as in repair MCB SP 240 volts, 50 Hz capacity 6-32 Amps \"B\" curve all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE |
| 40 | Supply and fix as in repair MCB SPN/ DP 240 volts, 50 Hz capacity 40 to 63 Amps \"B\" curve all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE |
| 41 | Supply and filling for dry sand in cable protection trenches before and after the cables are laid, for sand cushioning to cables complete all as specified and directed. NOTE : thickness after punning of sand shall be (minimum as specified in SSR) measured and paid in this item. |
| 42 | Material and labour for brick protection for UG XLPE cable with burnt clay old size sub class \"B\" bricks laid dry and flat abutting each other with gaps between adjacent brick not more than 10mm and width equal to length of brick in trenches across the cable complete all as directed by Engineer-In-Charge.Make: Best quality locally available which is duly approved by GE. |
| 43 | Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured,electric powercables (heavy duty) 1100 Volts grade conforming to IS 7098 withaluminium conductor multi-strand of cross-sectional area 6 Sqmm 2.00 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc.all as directed by Engr-In-Charge.Make: Polycab(ISI Marked)/ Finolex(ISI Marked)/ Havells (ISI Marked)/ Gloster (ISI Marked)/ KEI (ISI Marked)Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately |
| 44 | M&L for horizontal boring for 15 mm bore GI pipe under road/pavement/hard standing at 0.45 m to 1.5 m depth from top of road level and insert 15 mm medium GI for Laying XLPE UG Cable with all necessary fittings and without any damage of road/pavement/hard standing surface complete all as specified and directed.Note :- (i) Necessary earth work shall be carried out and the cost for the same shall be included in the rate quoted for this item.(ii) GI pipe shall be measured and paid including this item |
| 45 | Material and labour for tubes \"light grade\" galvanised with all fittings laid in trenches of 15 mm bore dia. Make : Tata / Jindal Steel / Prakash/ Surya Roshni ltd |
| 46 | Supply and fix SMC cable junction box of size 295 mm x 195 mm x 100 mm with terminals / connectors, mounting bracket & polyamide cable gland with lock nut & bolts including internal connections with proper size Copper/ Aluminum lugs/ thimbles includingfixing on pole with clamps and also drilling of two holes on pole for inserting PVC insulated copper cable complete all as directed. |
| 47 | Supply and fixing as in replacement GI bracket for street light made out of 40 mm dia GI pipe light grade 1.5 mtr length bend in shape as required complete with 2 nos of MS flat iron clamp of size 50 mm x 6 mm, nuts and bolts etccomplete as specified and as directed |
| 48 | Supply and fix100 W LED street light made up of pressure die cast aluminium housing with high efficient LED with driver IP 65 luminiares comprising of high brightness LEDs and all accessores complete including taking down old u/s fitting all as specifed and directed.Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 49 | Supply and fix as in repair LED Post top lantern of 60 Watts, 240V, 50Hz IP 65 made of black ABS plastic spigot, spun aluminium funnel shape with clear acrylicand accessories such as integrated drivers pre-wired etc suitable with gate lightpipe.Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 50 | Supply and fix as in repair LED Post top lantern of 40 Watts, 240V, 50Hz IP 65 made of black ABS plastic spigot, spun aluminium funnel shape with clear acrylicand accessories such as integrated drivers pre-wired etc suitable with gate lightpipe.Note:- (a) LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings.(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minium 50000 Hrs.(c) LED light fitting and drivers shall be of same make. |
| 51 | Supply and fix as in repair MCB SPN 240 volts, 50 Hz capacity 6-32 Amps \"B\" curve all as specified.Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE |