| 1 | Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete, all as specified. |
| 2 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified. |
| 3 | Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified. |
| 4 | Supply and Fixingin repairPP-R (Polypropylene random coplymer) concealed pipes 25mm boreSDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified. |
| 5 | Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 40mm boreSDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified. |
| 6 | Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 50mm boreSDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified. |
| 7 | Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 90mm boreSDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete all as specified. |
| 8 | Supply and Fixing in repair PP-R (Polypropylene random coplymer) concealed pipes 100mm boreSDR 7.4, 3 layer (PN 16) UV stabilized and antimicrobial fusion welded having thermal stabilized for hot &cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to wall,Ceiling or in trenches complete, all as specified. |
| 9 | Disconnection & taking out to non clog sewage submersible pump with motor of capacity 7.5 to 15 HPalong with column pipe of any size alongwithlowering the same after repaired motor / pump along with existing / replaced column pipe, and re-connection for three phase AC Supply and tested at site to the satisfaction of Engineer-in Charge. Note:- (i) Repair / replacement of pump /motor / column pipe / rubber gasket / Nut bolt and washers/Cable shall be measured and paid supply only in respective items of Schedule ‘A’. (ii) Transportation to defective motor / pump from well to work shop and vice-versa shall be deemed to be included in the unit rate of this item.Nothing extra shall be admissible on this account. (iii) The cost of T&P required for taking-out, loweringtosubmersible motor / pump / column pipe de-water the UG sump shall be deemed to be included in the unit rate of this item. Nothing extra shall be admissible on this account. |
| 10 | Dismantlingto existing unserviceable non clog sewage submersible pump with motor 15 HP, 3 phase, 440 volts, 50 Hz, 2900 RPM and rewinding to stator with PVCinsulated copper winding wire including sleeves, thimbles & minor spare parts like as bronze bushes, gland packing, water seal & adopter, stainless steel shaft,Neck ring,Bowl casing, Shaft sleeve ,impeller of gun metal etc and re-assembling to the same motor after repair work . complete all as specified and as directed by Engineer-in-Charge. |
| 11 | All as per aboveitem No 10 here-in-before but for submersible motor of13.20 HP. |
| 12 | All as per aboveitem No 10 here-in-before but for submersible motor of7.5 HP. |
| 13 | S&F for Nut, Bolt & Washers machine made suitable for jointing of column pipe fixed as in repaircomplete all as specified and as directed by Engineer-in-Charge |
| 14 | Disconnection & removingthe unserviceable column pipe and S&F 100mm bore mild steelwater pipeheavy duty both endflanged as column pipe as in repair complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Supply only PVC insulated multi-stranded copper conductor 16 Sq mm (nominal area) 3 core submersible cable (copper) and connected to submersible pump setincluding submersible cable joints & LT panel board complete all as specified and directed. |
| 16 | All as per above item No 15 here-in-before but for 10Sqmm |
| 17 | Supplyfixing FASDS(fully automatic star delta starter)enclosed in sheet steel enclousureFactory madesuit able for sewage non clog pump set but not less then 15 HP , 3 phase 415 volts, 50 Hzinclprovnofsingle phasing with CTs , Voltmeter&Ammeter with slector switch,LED Indicator,On & Trip indicator,with TP MCB \"C\"curve 3 phase Short circuit protection , fixing arrangement on wall etc complete all as specified . |
| 18 | Supplyfixing FASDS(fully automatic star delta starter)enclosed in sheet steel enclousureFactory madesuit able for sewage non clog pump set but not less then 12.5 HP , 3 phase 415 volts, 50 Hzinclprovnofsingle phasing with CTs , Voltmeter&Ammeter with slector switch,LED Indicator,On & Trip indicator,with TP MCB \"C\"curve 3 phase Short circuit protection , fixing arrangement on wall etc complete all as specified . |
| 19 | Material and labour for desluding of sewage sumpat various location by providing necessary arrangement todispose off the sludge wastemanualy with rope , buckets, chain pully and ladder/mechanical eqpt /veh etc and burried the waste mateial at disance approximate 50 mter away (under ground) . Cleaning of complete sumpand sump room and applying two coats of whitelime wash complete all as specified and as direted Note :-1.Tender may visit the site before quoting the rates . 2.All necessary T&P required shall be arranged by contractor.3.Net volume of sludge removedshall be measured .4.Contractor shall arrange necessary first aid for the worker so employed for the job to avoid any mishappning due to effulent. |
| 20 | Cleaning the area of sewage plantoutdoor/ indoor installations by cutting and removing jungle sturts, roots, bushes plants small trees etc and deposited to n.exc 50 mtr to 100 mtr out side installations complete allas specified and as directed by Engr-in-Charge. |
| 21 | Supply & fixing in repair butterfly Valve 150mm complete all as specified and as directed. |
| 22 | Supply & fixingin repair butterfly Valve 100mm complete all as specified and as directed. |
| 23 | Supply & fixingin repair butterfly Valve 80mm complete all as specified and as directed. |
| 24 | S&F in repair/replacement of 3P Contactor MNX 32A, Coil Voltage 415V, 50 Hz including connecting the cable complete all as specified and as directed. |
| 25 | S&F in repair/replecement ofAutomatic star/delta starter in stainless steel enclosure with relay max range 20 to 32 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 40 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed. |
| 26 | S&F in repair/replacement of DOL starterType - MK1, 15A, 3 Phase, 50 Cycles, Relay Range upto 9-14 Amp, 415V/440V including connecting the cable complete all as specified and as directed. |
| 27 | Supply & Fixas in repair incl testing and Commissioning of chemical dozing pump high pressure single head, adjustable dozing pump and high pressure range 0 to 100 PSI , Power 230 volts, 50 Hz, 40 Gallons per day self priming with vertical or Horizontal mounting type complete all as specified. Note: sample will be approved by GE. |
| 28 | Supply & Fixas in repair chemical dozing system consisting oftwo Nos FRP Tanks i e 1x170 Litre capacity and 1x 100 Ltr capacity with FRP lid and level gauge alongwith water inlet /outlet line with Y strainer, drain plug, over flow pipe, having conical bottom for sludge deposition, port hole with coverPlastic - mounted on tank. Lid will have port hole for pouring Granular chemical and water and shall have provn of mountingdozing pump complete all as specified. Note: sample will be approved by GE. |
| 29 | Supply & Fixas in repair agitator motor 120 Watt,copper wound, 900 RPM, Single phase 230 Volt with Shaft and impeller and all accessories suitable for mounting on FRP Tank lid or wall all as directed by Engr-in-charge. |
| 30 | Supply & replacement ofpump tube for chemical dozing systemas per existing make and dimension and as directed complete all as specified and as directed |
| 31 | All as per item No. 30 above but injection check valve 3/8\" . |
| 32 | All as per item No 30 abovebut discharge tubing 3/8\" . |
| 33 | All as per item No.30 abovebut Rotar Assy with bearings brackets and tolerances ring . |
| 34 | All as per item No.30 above but suction line strainer 3/8\" . |
| 35 | All as per item No.30 above Roller Assy . |
| 36 | All as per item No.30 above but Gear motor complete 230 volt, 50 Hz . |
| 37 | All as per item No. 30 above but Coil 250 volt 50 Hz . |
| 38 | M&L DI pipe 200mm (certifugally cast) class \"K-7\" (ISI Mark) in anylength with spigot and socketendscomplete including rubber ring joint (Tyton joint)as per IS- 1536-2001 jointedand laid in trenches or in any position, complete including taking down any type and size of pipe all as specified . Note :- Cost of rubber ring (tyton)joint is deemed to be included in the quoted rates |
| 39 | All as per item No. 38 above but 150mm. |
| 40 | All as per item No. 38 above but 100mm. |
| 41 | All as per item No. 38 above but 80mm. |
| 42 | Supply and fixing of CI/DI fittingsof size up to 200mm bends ( any radius and angle )Tapers any type,( straight, bend , increasing,decreasing or double socketetc)Tee pieces single branch. `Y` junction , double branch cross ( all socket or socket and spigot/ flanged as required at site) collars, caps and plugs etc.,complete all as specified. |
| 43 | Supply and fixing Rubber gasket joint for 100mm dia pipe complete all as specified. |
| 44 | All as per item No. 43 above but 150mm dia pipe complete all as specified. |
| 45 | All as per item No. 43 above but200mm dia pipe complete all as specified. |
| 46 | Disconnection and removing the U/S Sluice Valve and S&F Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & 02 Nos rubber insertion packingetc for 200mm bore pipe and fixed, in epairs, complete all as specified. |
| 47 | All as per item No. 46 above but 150mm bore. |
| 48 | All as per item No. 46 above but 100mm bore. |
| 49 | All as per item No. 46 above but 80mm bore. |
| 50 | S&F Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm dia, in repairs , complete all as specified. |
| 51 | All as per item No. 50 above but 40mm dia. |
| 52 | All as per item No. 50 above but 25mm dia. |
| 53 | All as per item No. 50 above but20mm dia. |
| 54 | S&F Cast iron Non return valve of 100mm dia withprovn of two end spoigot and socket suitable for rubber tyton joint and one end flangedfixed with removable MS plateincl ,rubber gas kit,nut,bolt ,washers,andmaking suitable fixing arrangement to spoigot and sockete DI 200 MM dia pipe etc complete all as specified .Note : Fitting will be measured and paid separetly, if any, required. |
| 55 | S&F 100mm bore cast iron Air release valve with two air outlets complete with fixing arrangement, as in repair complete all as specified and as directed by Engineer-in-Charge. |
| 56 | Arresting of water leakage from existing pipe line in position from DI/CI/GI pipe of size 150 mm to 200 bore ,including excavation through Men/Mechanical power ,cutting,welding as per site requirement,jointing material such as lead joint/gaskit joint/CI fitting, nut and bolts,washers and refilling etc complete all as specified .Note:-(i) Excavation up to 1x1x6 Mtr will be deemed to be includedin quoted rate.(ii), DI / CIfitting and pipe length) will be measured and paid saperately under appropriate item of sch \"A\" herein.(iii) Cost of new pig lead/lead wool required for repair of leakages is deemed to be included in the quoted rates. |
| 57 | All as per item No. 56 above but 100mm to 150mmbore |
| 58 | All as per item No. 56 above but 50mm to 100 bore. |
| 59 | All as per item No. 56 above but 25mm to 40mm bore. |
| 60 | All as per item No. 56 above but 15mm to 20mmbore. |
| 61 | Locating blockage in existing distribution pipeline 80mm dia any type in position by excavation work manualy in any type of soil upto 750x500mm upto max 2Mtr length at various location( Maximum up to 3 location ) incuding necessary cutting/threading/welding work & provision of required size offittings such as union/socket 1no ,replacement of damaged pipeline,returning filling and removal of surplus soil complete all as specified .Note :-(i) Pipe length will be measured and paid saperately under approriate item of sch \"A\"(ii) Contractor shall restore supply system within in 8Hrs. |
| 62 | All as per item No. 61 above but 40/50mm dia. |
| 63 | S&F Run lead joint for 150mm pipe complete all as specified and as directed by Engineer-in-Charge. . |
| 64 | All as per item No. 63 above but200mm pipe complete all as specified and as directed by Engineer-in-Charge.. |
| 65 | All as per item No. 63 above but 100mm pipe complete all as specified and as directed by Engineer-in-Charge.. |
| 66 | All as per item No. 63 above but 80mm pipe complete all as specified and as directed by Engineer-in-Charge.. |
| 67 | Construction of brick masonary valve pits,of internal size 120x120x100cm (depth of chamber to be recokoned from the top of PCC in foundation to top of MS cover) of chamberwith and including MS sheet cover fabricated from 11 gauge MS sheet and frame of angle iron 40 mm x 40 mm x 5 mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer on MS cover and frame including necessary excavation and earth work in any type of soil, returning, filling in approved soil, disposal of surplus soil to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation brick work in cement mortar 1:6, 15 mm plastering in cement mortar 1:4 both internally and externally 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified. |
| 68 | Construction of valve pit chamber of size 120 x120 x120 cm with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thickwith locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamelblack paint over a coat of red oxide primer to steel surfaces including necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified. |
| 69 | Construction of valve pit chamber of size 90 x90 x90 cm with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thickwith locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamelblack paint over a coat of red oxide primer to steel surfacesincluding necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified. |
| 70 | Cutting of existing /cast iron pipe of 150mm bore for insertion of new tees & branch line of any bore in position complete and all as specified. |
| 71 | Cutting of existing /cast iron pipe of 100mm bore for insertion of new tees & branch line of any bore in position complete and all as specified. |
| 72 | Supply and fixed only Pig lead complete all as specified. |
| 73 | Supply and fixed only lead wool complete all as specified. |
| 74 | S&F in repair Tubes 20mm bore, ‘medium grade’, ISI MARKED, galvanized with all fittings and fixed completelaid in trnches or walls and ceilings or laid in floors, complete all as specified. |
| 75 | All as per item No. 74 above but 25mm bore. |
| 76 | All as per item No. 74 above but 40mm bore. |
| 77 | All as per item No. 74 above but 50mm bore. |
| 78 | Cutting and threading existing 15mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) complete all as directed by the Engineer- in-Charge. |
| 79 | All as per item No. 78 above but 20mm bore. |
| 80 | All as per item No. 78 above but 25mm bore. |
| 81 | All as per item No. 78 above but 40mm to 50mm bore. |
| 82 | M&L for trench less cutting for passing upto 200 mm dia DI pipe complete all as specified and directed by the Engineer- in-Charge. |
| 83 | Comprehensive maintenace, Repair/servicing of4 x RO water purifier 500LPHcapacity of any make installed at various location at N area and Hallomajraas per under mentioned detail.(i) contractor has to provide one service each month by qualified technician.(ii) All complaints shall be attended on the same day.(iii) Repair to motor,mpv panel,flow meter and membrane cleaning,replacement of micron /sand/carbon filter ,or any other minor spares and propriotory material ie. Descaling solution, salt etc. will be covered under below item rate. |
| 84 | Supply and replace RO Membrane suitable for 500 LPH capacity of plant as per existing make and size complete all as specified and directed by the Engineer- in-Charge. |
| 85 | Supply and replace JUMBO filter suitable for 500 LPH capacity of plant as per existing make and size complete all as specified and directed by the Engineer- in-Charge. |
| 86 | Supply and fix in repair eletric driven single phase 230 volts 50 HZraw water pump for flow rate 1200 LHP @ 3.5Kgsqcm pressure complete all as specified and directed by the Engineer- in-Charge. |
| 87 | Spply and fix in repairelectric driven single phase 230 volts 50 Hz high pressure pump set2 HPautomatic grade with stainless steel bodySS 304 suitable for for discharge 1200 ltr /hrand maximum pressure 12 bar complete all as specified and directed by the Engineer- in-Charge. |
| 88 | Supply and fix in repair float switch (Low & High) for RO plantof cap 500 LPH complete all as specified and directed by the Engineer- in-Charge. |
| 89 | Supply and fix in repair Mulitiport valve 25 NB fully automaticfor RO plant of cap 500 LPH complete all as specified and directed by the Engineer- in-Charge. |
| 90 | Supply and fix in repair Auto control panel with low pressure switch for RO plant of cap 500 LPH complete all as specified and directed by the Engineer- in-Charge. |
| 91 | Supply and fix water supply Vessel 10x54 carbon and sendiment including with multiport Valve complete all as specified and directed by the Engineer- in-Charge. |
| 92 | Supply and fix membrane housing 40x80 complete all as specified and directed by the Engineer- in-Charge. |
| 93 | Supply and fix Jambo housing 20 inch complete all as specified and directed by the Engineer- in-Charge. |
| 94 | Supply and fix anty scalant dozing pump complete all as specified and directed by the Engineer- in-Charge. |
| 95 | Supply and apply anty scalant membrane cleaning chemical complete all as specified and directed by the Engineer- in-Charge. |
| 96 | Supply and fix uPVC pipe of 25mm dia complete with fittings all as specified. |
| 97 | Supply and fix uPVC pipe of 32mm dia complete with fittings all as specified. |
| 98 | Supply and fix MTA and FTA of any size and make complete all as specified and directed by the Engineer- in-Charge. |
| 99 | Supply and fix Rota meter 500 LPH complete all as specified and directed by the Engineer- in-Charge. |
| 100 | Note: For the purpose of arriving at lumpsum amount, the amount of credit schedule i.e Sch \"A\" section II (i.e Rs 204,664.00 shall be deducted from the total amount arrived. |
| 101 | Total of Schedule \"A\" Rs. |