| Sl. No. | Item Description |
| 1 | Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonryand removal complete all as specified& directed by Engr-in-Charge. |
| 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for Repair of cable by getting out the any type soil,protection cable cover/bricks and sand and keept itin stachfor reuse after repai / replacement of cable etc. complete all as specified and directed. |
| 3 | M&L for PCC 1:2:4 type B1 (using 20 mm gradded stone agg )as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, drain channels, copings,parapetscopings, haunching, benching, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed. |
| 4 | M/L for PCC (1:3:6) typeC-1 using 20mm graded aggregate as in foundation/surface repair for pole / Platformetc complete all as specified and directed. |
| 5 | M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 6 | M & L brick work with old size sub-class ‘B’ bricks,(OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed. |
| 7 | Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish of the premises complete all as specified and directed. |
| 8 | M&L for glazed ceramic coloured tiles any coloured / shedof size 300mm x 600mm x 6 to 7mm on vertical surface such as skirting, dados, risers to steps etc set &jointed in neat cementslurry and pointed inwhite or coloured cementto match the colour oftiles, laidover and includingrendering10mm thick in cement mortar (1:4), complete all as specified and directed. |
| 9 | Demolition ofStone slabs and tiles of any description or thickness in floors, aprons etc. and Laidbeddedandpointedin any mortar complete all as specified and directed. |
| 10 | M&L for 16 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified& directed by Engr-in-Charge. |
| 11 | M&Lfor rounding to edges of stone/granite slabs one edgesuch as in steps cooking platform , window cilland other situations complete all as specified & directed. |
| 12 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed by Engr-in-Charge. |
| 13 | M&L for 25 thick cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as inlevelling coarse for tiles complete all as specified and directed. |
| 14 | M&L for colourCeramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile of size exc 0.11 sqmand but not exc 0.18 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. |
| 15 | M&L for 75 mm thick PCC 1:3:6 type C1 using 40 mm graded stone aggregate as inplinth protection surface finished fair and even complete all as specified and directed. |
| 16 | Taking downchowkhats(without taking off shutters from the frames) chowkattsn exc 1.5 sqm each complete all as specified & directed by Engr-in-Charge. |
| 17 | S&F Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for three/two tracks shutters/ frames/grill for doors, windows, ventilators and partitions (Fixed portions), slinding windows, incl rollers, with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 18 | M&L for Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks, plainblack sheet door shutters,door chowkats(frames) ,chullah hoods; water tanks; water troughs; grease trap cover,fasterning for concrete,ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, cloutnails or rivets and fixed to wood or steel members, etc., , and the like includingcaps,bases, splices etc. built up from twoormore beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directedby Engr-in -Charge. |
| 19 | Supply only 4 mm thick glass sheet any shade tintglass, ordinary quality and glazing with rubber bedding in square n exc 0.5 sq.m in each panecomplete all as specified & directed by Engr-in-Charge. |
| 20 | Supply only 3mm thick glass sheet froasted glass, ordinary quality and glazing with rubber bedding in square n exc 0.5 sq.m in each panecomplete all as specified & directed by Engr-in-Charge. |
| 21 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 22 | Dismantlingtimber scantlings unframed 40 sq. cm and over in section, in any position complete all as specified and directed. |
| 23 | M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 Complete all as specified. |
| 24 | M&L painting to new or previously untreated steel surfaces of any description over 10cm in width or girth with two coats of synthetic enamel paint over a coat of zincchromic primer including preparation of surfaces complete all as specified and directed. |
| 25 | Returning filling in inculding spreading ,levelling ,watering and well ramming in layers nit exc 25 cm Soft /loose soil complete all as specified and directed. |
| 26 | M&L for Earth work for Grease Trap / Soak well/septic tank/manholes/sewage lines etc and similar worksin excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, exc 30cmin width including getting out and disposal of all kind of soilexcavated earth lead upto 50 m and lift upto 10mtr as directed by Engineer-incharge |
| 27 | Excavating in post holes in soft/ loose soils(or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified. |
| 28 | M&L of sand filling under floor or in foundation including watering and consolidation complete all as specified and directed. |
| 29 | Labour only for laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable complete all as specified and directed. |
| 30 | Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point all as specified and directed. |
| 31 | Removal of excavated material (soil) to a distance exc 50m but notexc 250 mtrand depositing where directed at a level n.exc 1.5m above or below the starting pointcomplete all as specified & directed by Engr-in-Charge. |
| 32 | M&L for PCC Type C2 1:3:6 (40 mm graded aggregate) Cement concrete in foundations, filling and mass-concrete complete all as specified & directed by Engr-in-Charge. |
| 33 | M&L for Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass filling in drains, incl foundation/surface repair for ple/ platform etc. complete all as specified and directed by Engr-in-Charge |
| 34 | M&L forStairs (framed) including stringers , treads, landing , balusters, hand rails etc , cooler stand including cleats brackets, etc completewith gusset plate , rails braces etc. completeusing Fe- 290 (Gde E-165) quality \"A\" compleete all as directed by Engr-in-charge. |
| 35 | S&F for Pre-painted galvalumealuminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 36 | M&L painting to new or previously untreated steel surfaces of any description over 10cm in width or girth with two coats of synthetic enamel paint over a coat of zinc chromic primer including preparation of surfaces complete all as specified and directed. |
| 37 | M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 38 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 39 | Supply and fixing stainless steelhinges 100mm long medium weightto pressed steel/angle iron frames by welding/screws all as specified. |
| 40 | S&F aluminium anodised barrel tower bolt 150mm size extruded section, ISI marked & fixed |
| 41 | S&F extruded aluminium alloy handles 150mm size fabricated type anodised. ISI marked. |
| 42 | Taking down cement plaster on brick or stone wall etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 43 | M&L rendring 10mm thick on fair faces of brick work or concrete surfaces on walls, finished even and smooth without using extra cementin CM 1:6complete all as specified and directed by Engr-in-Charge. |
| 44 | M&L for rendering cement plaster 10mm thick in cement mortar 1:3 on fair faces of concrete in ceilings, chajjas, fins facia etc. finished even and smooth without using extra cement complete all as specified and directed. |
| 45 | M&L for rendering 12mm thick in CM 1:4 on stone wall surfacesfair faces of brick work & finished even and smooth without using extra cementwith water proof compound ( water proof compound paid seperatly) complete all as specified and directed. |
| 46 | M&L Rendring 15mm thick on fair faces of brick work or concrete surfaces with water proof compound (LWPC will be measured and paid seperately) on wall in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.Note :- Water proofing compound shall bemeasured and paid seperately under respective item. |
| 47 | Material and labour forpreparation of newly plastered/unplasteredsurfaces of ceilings & applying three coats of white wash complete all as specified and directed. |
| 48 | M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means and preparation for next treatment complete all as specified and directed. |
| 49 | M&L for 1mm thick wall care puttyon walls surface incl prepare to surface for next treatment complete all as specified and directed. |
| 50 | M&L forprepration of old surfaces of ceillingand applyingtwo coat of white wash complete all as specified and directed. |
| 51 | M&L for Distempering withacrylic distemper, of approved, of required shade and colour complete, as per manufacturer\"s specification. Twocoats on existing preparedwalls surface complete all as specified and directed. |
| 52 | M&L preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 53 | M&L preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 54 | Taking up or down 15mm steel tubing and connections, complete all as specified& directed by Engr-in-Charge. |
| 55 | S&F steel tubing medium grade 15mm bore with all fittings fixed complete to wall and or laid in floorcomplete all as specified & directed by Engr-in-Charge. |
| 56 | Supplying and laying of 20mm outer dia CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed. |
| 57 | S&F for CPVC PIPE OUTER DIA 20MM Brass Elbow (3/4 X ½) complete all as specified and directed. |
| 58 | Taking up or down 20mm steel tubing and connections, complete all as specified & directed by Engr-in-Charge. |
| 59 | Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 20mm bore of pipe complete all as specified and directed. |
| 60 | S&F 20mm GI tubing Medium grade fix to wall/floorcomplete all as specified & directed by Engr-in-Charge. |
| 61 | Taking up or down 25mm steel tubing and connections, complete all as specified & directed by Engr-in-Charge. |
| 62 | Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 25/32mm bore of pipe complete all as specified and directed. |
| 63 | S&F 25mm GI tubing Medium grade fix to wall/floorcomplete all as specified & directed by Engr-in-Charge. |
| 64 | M& L for Cutting chases, pinning in, for brick walls, making good to facings for concealed water tubing etc. cutting exceeding 10cm but not exceeding 20cm girth complete all as specified and directed. |
| 65 | S&F Rotational moulded polyethylene water storage tanksof 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I includng dismantling of of old tank complete all as specified & directed by Engr-in-Charge. |
| 66 | Disconnecting, setting aside (or lowering if required) andCleaning & removing all scale and dirt etc from HDPE water tanks of 500 litres capacity (Tanks placed on top of roof)and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed. |
| 67 | S&F ball valves brass high pressure with polythelene float and fly net complete, screwed, iron pipes 20 mm diacomplete all as specified & directed by Engr-in-Charge |
| 68 | S&Fin repair ball valves brass high pressure with polythelene float and fly net complete, screwed , iron pipes 20 mm diacomplete all as specified & directed by Engr-in-Charge |
| 69 | Dismantling of cast iron, PVC or reinforced concrete drain pipes jointed in cement mortar upto 110mm and75mm bore of pipe from wall/floors etc complete all as specified and directed. |
| 70 | S&F, 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including stack \"Z\" clamp complete all as specified and directed. |
| 71 | S&F, 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including \"Z\" clamp complete all as specified and directed. |
| 72 | S&F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 73 | S&F 110 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 74 | S&F, 75mm bore PVC (SWR) bend, any radius complete all as specified and directed. |
| 75 | S&F, 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 76 | S&F, 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 77 | S&F, 110mm bore PVC (SWR) bend, any radius complete all as specified and directed. |
| 78 | S&F, 110mm bore PVC vent cowl complete all as specified and directed. |
| 79 | M&L, in repair, PVC (SWR) Gully trap 125/100mm ssetting and jointing with cement mortar (1:1) complete all as specified and directed. |
| 80 | S&F, in repair, PVC (SWR) floor trap, with SS grating including jointing with solvent cement, dia of outlet 75mm complete all as specified and directed. |
| 81 | S&F, in repair, 40mm bore, low density polyethelene pipe (LDPE) of pressure rating 6kgf/sq.cm fixed to walls, ceilings or in floors etc. complete all as specified and directed. |
| 82 | S&F in repair fancy type bib taps, chromium plated alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule and fixed omplete all as specified & directed by Engr-in-Charge. |
| 83 | S&F in repair fancy type long bodybib taps, chromium plated alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule and fixed omplete all as specified & directed by Engr-in-Charge. |
| 84 | S&F in repair angle valves/stop valve ,fancy type, chromium plated alloy screwed down high presure, screwed both ends for iron pipe or for unions of 15 mm dia complete all as specified & directed by Engr-in-Charge. |
| 85 | S&F in repair vitreous China squatting pan \"Orissa pattern\" size 580x440 mm, white with integral foot rest including \"P\" or \"S\" trap front or back inlet excluding flushing cistern and flush pipe including connection to trap and flushing pipe etc and making good to floor complete all as specified and directed. |
| 86 | S&F in repairPVC valveless, syphonic action type, flushing cistern of 10 ltrs capacitylow level, white, with intel, ball valve, float and handle including bracketscomplete all as specified & directed by Engr-in-Charge. |
| 87 | S&F in repair PVC connection of 15mm bore with2 Nos. PTMT nuts, 60cm long fixed with one end to pillar tap & the other end to stop cock or iron pipe all as directed by Engineer-in-charge. |
| 88 | S&F in repair fancy typePillar tap,swan neckcast copper alloy with capstan heads, chromium plated, screwed down high pressure with or withoutlettered \"Hot\" or \"Cold\" with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore all as specified |
| 89 | Supply and fixing 150mm dia double wall corrugated Class SN8 ,laid and joints complete with collars etc complete all as specified and directed. |
| 90 | S&F in repairlooking mirror 5 mm thick selected quality of any size including necessarymoulding , stainless steel cup and washer etc complete all as specified and directed. |
| 91 | Providing and laying 100mm thickfor precast SFRC manhole cover with frameincluding complete sides iron sheets (medium ) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 20 ton /Sqm in square or rectangular shape(size as site requirement)complete all as specified and directed by Engr-in-Charge. |
| 92 | S&F in repairtubular towel rail, stainless steel, 20mm dia, ‘D’ type, 60cm long between flanges fixed to wall complete all as specified and directed. |
| 93 | S&F in repairkitchen sink without draining board bowl size 18\"x16\"x8\" inch of made out of stainless steel heavy dutywith plugs, washers and waste pipe includingwaste coupling and waste pipe complete all as specified & directed by Engr-in-Charge. |
| 94 | M&L for formwork to soffits of suspended slabs such as wash hand basin ,roof slabs, floor slabs, landings and similar work, not exc 200mm thick (horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and directed. |
| 95 | M&L for reinforced cement concrete nominal mix1:2:4 ,using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like complete all as specified and directed.Note :- Reinforcement & formwork shall be measured and paid for separately. |
| 96 | M&L for mild steel TMT bars 10mm dia & over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia completeall as specified and directed. |
| 97 | Supply only integral liquid water proofing compound (ISI marked) complete all as specified and directed. |
| 98 | S&Fwall mixer chromium plated (2 in -1) with arrangement for overhead shower with 220 mm max long bend pipe including 125mm x125mm over head shower complete all as specified & directed. |
| 99 | S&Fin repair sink cock faucet wall mountedchromium platedand suitable screwed for iron pipes of 15mm bore GI pipeall as specified complete all as specified & directed. |
| 100 | S&F, in repair, vitreous china wash basin, white, flat back of size 450mm x300mm including brackets grouted in cement mortar 1:2 in wall complete all as specified and directed. Note :- Supply only pillar taps, waste fittings, PVC connection, PVC waste pipe shall be measured and paid separately. |
| 101 | M&L for 150mm dia Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 102 | S&Fstainless steel Kitchen plate rack of overall minimum size 750mm x 750mm and 230mm deep, with partitions for small/large plates etc made out of stainless steel 24 Gauge, fixed with rawl plug and CP steel screws all as directed.Note : Weight of rack shall not be less than 4.00 Kg. |
| 103 | S&F in repair 19/20mm thickness factory made PVC solid board both side prelaminated approved texture as in kitchen cabinet/cupboard ( with shelves and partions) includingframe , beadingand necessary fittings & fixture likehinges, handle, magnet catch, lock etc as per manufacturers instructions andquality and make , made from rigid foam sheets having density 600 Kg/Cum and laminated sheet /PVC foil lamination . the exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter/frame shall be fire retardent having necessary scrwed holding capacity & incl necessary fittings etc complete all as specified and as directed. |
| 104 | S&F in repair stainless steel curtainrod of 25 mm dia(in lengths as directed) heavy duty with decorative ball type side brackets supporting hook etc , both ends and pairwith PVC rawl plug & steel screws on walls/beam complete all as specified and directed. |
| 105 | M&L for water proofing of sunken portion consisting under mentioned items :-(i) 15 mm thick plastering in C:M 1:3 with liquid WPC at all around and base of sunken floor with proper slope.(ii) Applying a coat of bitminous primer @ 0.30 litre/sqm and conforming to IS-3384, laying APP based polyster modified membrane reinforced non wooven polyster of 3.50 Kg/Sqm (minimum), sealed by torching including demolition and removal of old concreteand provn of new lean cement concrete 1:5:10 type E 2 using 40 mm graded stone aggregate specified complete all as specified and directed. |
| 106 | Dismantling/Demolition/Chipping carefully loose/distressed portions of reinforced cement concreteto a depth or thickness varying from 10 mm to 100mm (reinforcement cut as required to facilitate demolition) work by means of sharp chisel, low impact hamer without damaging existing strong concrete upto the suitabale depth of unsound concrete in beams, roofs, chajjas, columns, staircase, landing, parapets, soffits of slabs and similar suspended worketc incl disposal of broken material/malba to the distance of 50m complete all as specified and directed.Notes :-(i) Work to be carried out in patches.(ii) The rates for scaffolding system to be used upto 15 mtr workable height shall be deemed including in the above rates and no extra shall be paid over & above the quoted rates. |
| 107 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat with peak, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 108 | Material and labour for Taking outany type light fittings complete all as specified and directed. |
| 109 | Labour only for laying old bricks /un-reinforced precast concrete cable cover,any size and typeretrieved from ser no.1 complete all as specified and directed. |
| 110 | Labour only for refixingany type light fittings ny size and typeretrieved from ser no.1completeall as specified and directed |
| 111 | Material and labour for Taking outLT cable,after taking electrical shutdown complete f cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 4 Core x 16 Sqmm complete all as specified and directed. |
| 112 | Material and labour for Taking outLT cable,after taking electrical shutdown complete f cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 4 Core x 10 Sqmm complete all as specified and directed. |
| 113 | Material and labour for Taking outLT cable,after taking electrical shutdown complete f cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 10 Sqmm complete all as specified and directed. |
| 114 | Material and labour for Taking outLT cable,after taking electrical shutdown complete f cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 06 Sqmm complete all as specified and directed. |
| 115 | Material and labour for Taking outLT cable,after taking electrical shutdown complete f cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 04 Sqmm complete all as specified and directed. |
| 116 | Material and labour for Repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 4 Core x 16 Sqmm complete all as specified and directed. |
| 117 | Material and labour for Repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 4 Core x 10 Sqmm complete all as specified and directed. |
| 118 | Material and labour for Repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 10 Sqmm complete all as specified and directed. |
| 119 | Material and labour for Repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 06 Sqmm complete all as specified and directed. |
| 120 | Material and labour for Repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 4 Sqmm complete all as specified and directed. |
| 121 | Labour only for Repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 4 Core x 16 Sqmm complete all as specified and directed. |
| 122 | Labour only for Repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 4 Core x 10 Sqmm complete all as specified and directed. |
| 123 | Labour only for Repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 10 Sqmm complete all as specified and directed. |
| 124 | Labour only for Repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 6 Sqmm complete all as specified and directed. |
| 125 | Labour only for Repair/ replacement of LT cable, laying and testingof cableXLPE Insulated , galvanized steel strip or wire armoured,heavy dutyLT electric power cables 1100 Volts grade with stranded aluminium conductor of size 2 Core x 4 Sqmm complete all as specified and directed. |
| 126 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr-in-charge |
| 127 | M&L for horizontal drilling, in any type of soil, using trenchless technology suitable for insertion of GI pipe /Medium Grade PVCandLT cablesalong the pipe complete all as specified and directed of50 MM DIA GI PIPE complete all as specified and directed. |
| 128 | Material and Labour for Double Compression cable Gland weatherproof suitable for cable 10 to16 Sqmm complete all as specified and directed. |
| 129 | S&F GI tubing light grade galvanised /Medium Grade PVC with all fittings like Bend Elbow Tee etc& fixed complete wall/pole for 40mm bore complete all as specified and directed. |
| 130 | S&F GI tubing light grade galvanised/Medium Grade PVC with all fittings & fixed complete wall/pole for 50 mm bore complete all as specified and directed. |
| 131 | Supply, installation, commissioning and testing, in repair, Time switch panel , LT (415 Volts, 50 Hz , 3-phase, 4 wire supply),CPRI approved, plinth mounted, factory made, outdoor type of size (1500 x600 x 1000) mm weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.2 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:-(a) Incoming supply:- (i) Mains incomer, 63 A, 25 kA, 4-pole MCCB with adjustable thermal-magnetic release - 01 No(ii) Indicating lamp Neon type for R-Y-B - 3 Nos (vi)Extended rotary handle & spreader terminals for above MCCB-01 Nos (vii) 6 A TP MCB-01 Nos.MAIN BUSBAR SIZE- 25 X 10 mm. EC grade aluminium busbarsMAIN BUSBAR SIZE (For neutral)-25 X10 mm. EC grade aluminium busbarsEARTHING BUS 25 x 10 mm. EC grade aluminium busbarsPANEL MOUNTING-Floor mountedCABLE ENTRY-Bottom for both incoming and outgoingPANEL FABRICATION-From 11G CRCA sheet steelFINISHING-Powder coating (min. 80 micron) after 7-tank process to shade RAL-7035PANEL DIMENSIONS- App. 750 mm. (H) X 700 mm. (W) X 450 mm. (D) |
| 132 | M&L for Repair of CableBy Insertion of Straight trought Joint Cold Shrink Typefor LT Cable 10 Sq mm 2 Corewith all accessories all as spd and directed |
| 133 | S&F, aluminum / Tinned lugs for cable size 2.5 to 16 sqmm complete all as specified and directed. |
| 134 | S&F PVC insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth pipe, on pole/wall from juntion box to street light fitting complete all as specified and directed. |
| 135 | Supply and fixing LED Out doorunder Water Fountain Light Fittings complete IP-68, 220 Volt Ac50 Hzof RGBColour 36 Watt (12 x 3 ) complete in all respect all as directed. |
| 136 | Supply and fixing Tricolour LED Bollard / Column LightFittings of 1 mtr Height suitable for 220 volt Ac 50 Hz Supplycomplete in all Respect all as directed. |
| 137 | Supply and fixing LED Out door land scape ProjectionFlood Light Fitting complete IP-54, 220 Volt Ac50 Hzof RGBColour 36/45 Watt (12/15 x 3 ) complete in all respect all as directed |
| 138 | Supply and fixing LED Out door land scape ProjectionFlood Light Fitting complete IP-54, 220 Volt Ac50 Hzof RGBColour 60 Watt (20 x 3 ) complete in all respect all as directed |
| 139 | Supply and fixing TricolourColumn LEDLightFittings of 2 mtr Height suitable for 220 volt Ac 50 Hz Supplycomplete in all Respect all as directed. |
| 140 | Supply and fixing LED StripLightFittings of 10 mtrRollwith Driver of Red,Orange,Green., Blue, Voilet,White, Golden , Silver, Pink Colour suitable for 220 volt Ac 50 Hz Supplycomplete in all Respect all as directed. |
| 141 | Supply and fixing LED Out door land scape ProjectionFlood Light Fitting complete IP-54, 220 Volt Ac50 Hzof120 Wattcomplete in all respect all as directed. |
| 142 | Supply and Fixing 1 HP Single Phase, 220 volt Ac 50 HzSubmersible motor with Pump complete including starter and control panel with lighting controller complete all as specified and directed. |
| 143 | Supply and fixingLED Bollard LightFittings of9 watt suitable for 220 volt Ac 50 Hz Supplycomplete in all Respect all as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy