| 1 | S&F in repairs bracket for street light fitting made out of 40mm dia GI pipe light grade 1.2 mtr long each, bent to required shape andfixed to pole with and including MS clamps 02 Nos made out of 32X6 mm flat iron including GI nuts, bolts & washer and painting of clamps and street lightfitting bracket with two coat of red oxide primer and one finishing coat with aluminium paint complete all as specifiedand directed. |
| 2 | S&F in repairsbracket for street light fitting made out of 25 mm dia GI pipe light grade 1.2 mtr long each, bent to required shapeas directed by EIC & fixed to pole with and including MS clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts & washer and painting of clamps and street light fitting bracket with two coat of red oxide primer and one finishing coat with aluminium paint complete all as specifiedand directed. |
| 3 | Supply & fixing in repairs 45 W LED street Light luminaire made up of Pressure Die Cast aluminum housing IP 66 effeiceint protection with heat resistant toughned glass with indivdual LED lenses complete with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree) . The luminaire shall be complete available CCT 6500K,IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED street light should be top maintainable for easy maintenance. LED street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street Light shall havepower factor more than 0.95including testing after installation complete all as specified and directed |
| 4 | Supply & fixing in repairs 60 W LED street Light luminaire, made up of Pressure Die Cast aluminum housing IP 66 effeiceint protection with heat resistant toughned glass with indidual LED lenses complete with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree) . The luminaire shall be complete available CCT 6500K,IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED street light should be top maintainable for easy maintenance. LED street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street Light shall havepower factor more than 0.95 including testing after installation complete all as specified and directed. |
| 5 | Supply & fixing in repairs 70/72 W LED street Light luminaire, shall be made up of Pressure Die Cast aluminum housing IP 66 effeiceint protection with heat resistant toughned glass with indidual LED lenses complete with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree) . The luminaire shall be complete available CCT 6500K,IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED street light should be top maintainable for easy maintenance. LED street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street Light shall havepower factor more than 0.95 including testing after installation complete all as specified and directed. |
| 6 | Supply, fixing and testing of 100W LED Flood Light luminaire made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree) . The luminaire shall be complete available CCT 5700K,IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Flood light should be top maintainable for easy maintenance. LED Flood Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Flood Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Flood Light shall havepower factor more than 0.95including testing after installation complete all as specified and directed. |
| 7 | Supply, fixing and testing of 200W LED Flood Light luminaire made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree) . The luminaire shall be complete available CCT 5700K,IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Flood light should be top maintainable for easy maintenance. LED Flood Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Flood Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Flood Light shall havepower factor more than 0.95including testing after installation complete all as specified and directed. |
| 8 | Supply, fixing and testing of 100W LED highbay Light luminaire with tapered fin design and excellent thermal management along with IP-66 protection. LED highbay Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete available up to CCT 6500K,IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED highbay light shall be top cover maintainable for easy maintenance. LED highbay Light shall use multiple LEDs to get sufficient light output from the luminaire more than 20000 luman. The LED Flood Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver with SPD shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LEDLight shall havepower factor more than 0.95 complete all as specified and directed. |
| 9 | Supply, fixing and testing of 120W LED highbay Light luminaire with tapered fin design and excellent thermal management along with IP-66 protection. LED highbay Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete available up to CCT 6500K,IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED highbay light shall be top cover maintainable for easy maintenance. LED highbay Light shall use multiple LEDs to get sufficient light output from the luminaire more than 20000 luman. The LED Flood Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver with SPD shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LEDLight shall havepower factor more than 0.95 complete all as specified and directed. |
| 10 | Note for Item No 03 to 09 :- Contd..1. Driver should be potted anti-vibration types.2. LM-79 and LM-80test report with lakh burning hours LED life from NABL lab shuld be provided.3. CRI ( Colour Rendering Index) of fixture shall be >70.4. CCT (Colour Co-related Temprature of fixture shall be 5700K + 300K). 5. System Lumen Efficiency shall be >100 Lm/W.6. 10 KV separate surge protection shall be provided as a part of fitting7. Lenses shall be modular type.8. PCB used shall be MC PCB type.9. CA No shall be written on each fitting before installation.10. The Name of Manufacturer to be emborssed on the fitting. |
| 11 | Note for Item no 03 to 09:-11. The fittings shall have arrangement so that maintenance required, if any can be carried out from top cover. 12.The defect libility period of LED lights shall be 05 years from the certified date of completion and the contractor shall replace/ repair the defective fitting with in 07 days after handing over the replacement. 13. A guarantee of 05 years shall be provided by contractor, supported by OEM covered all parts of luminaire. Contractor shall deposit security on this account @ 5% of work done against these items otherwise the same shall be deducted from the dues payable to him in RAR/ Final Bill. |
| 12 | S&Fin repairs stay assembly comprising stay 14 mm dia and 40 cm long stay rod 20 mm dia and 1.8 m long threaded ends with nuts, mild steel plate 30 cm X 30 cm X 6 mm thick and two number of thimble etc. complete with accessories as shown in electrical plate No. 1 of SSR Part-I of 2009 including taking down existing stay assembly complete all as specified and directed.Note:- Loop type insulator, stay clamps, excavation & earh work and concrete shall be measured and paid separately. |
| 13 | S&F for galvanized steel stay wire size 7/ 4.0 mm for stay of poles complete all as specified and directed. |
| 14 | S&F loop type insulator vitreous, poecelain, white/brown/green, large size, with overall dimensions 65 x90 mm, clearanceof hole 16 mm complete all as specified and directed. |
| 15 | S&Fin repairsindustrial switchgear busbar chambers of size 600x600x150 mm of cap 200 A, 6 way for LT cable any size including necessary PCC/Wall mounted work, cable gland, all as in repair complete all as specified and directed. |
| 16 | Supply and fix in repairs 3 core PVC insulated and sheathed copper conductor cable of size 1.5 sqmm drawn through the existing pole/GI pipe bracket complete all as specified and directed. |
| 17 | Supply and fixing in repairs automatic street light switch for LED street light using infrared sensor based nature switch for autmatic switching of street light, 440 volt, 3phase of cap 5-8 KW, outdoor type factory made IP-66 protection having nature switch operating should be based on natural light flux level and selector switch to change the mode of operation, supply indicator with SMC box and locking arrangement . The sensor along withpower Contactor of cap up to 63 Amp and incoming and outloging MCB TPN cap upto 63 Amp with auto manual operation and overvoltage and overcurrent protection and auto trip & auto reset making arrangement incl internal wiring of copper cable FRLS 10 sqmm single core multistranded and mounted arrangement with clump and nut bolt on wall/poles, dust proof and temper proof complete all accessories as required and provided by manufacturer complete all as specified and directed. |
| 18 | Supply and fixing in repairs automatic street light switch for LED street light using infrared sensor based nature switch for autmatic switching of street light, 230 volt, single phase of cap 5-8 KW, outdoor type factory made IP-65 protection having nature switch operating should be based on natural light flux level and selector switch to change the mode of operation, supply indicator with SMC box and locking arrangement. The sensor along withpower Contactor of cap up to 40 Amp and incoming and outloging MCB TPN cap upto 40 Amp with auto manual operation and overvoltage and overcurrent protection and auto trip & auto reset making arrangement incl internal wiring of copper cable FRLS 10 sqmm single core multistranded and mounted arrangement with clump and nut bolt on wall/poles, dust proof and temper proof complete all accessories as required and provided by manufacturer complete all as specified and directed. |
| 19 | S&F in repairs fixedtype MCCB FP 415 volts, 63 Amps rating with rupturing capacity 25 KA including providing thimble for out going cablescomplete from LT Panel, complete all as specified and directed. |
| 20 | S&F in repairs fixedtype MCCB FP 415 volts, 100 Amps rating with rupturing capacity 25 KA including providing thimble for out going cables complete from LT Panel, complete all as specified and directed. |
| 21 | Supplying, jointing and connectingin repairs cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed. |
| 22 | Supplying, jointing and connectingin repairs cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 120 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed. |
| 23 | Supplying, jointing and connectingin repairs cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed. |
| 24 | Supplying, jointing and connecting as in repairs cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 120 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed. |
| 25 | Supply & fix in repairs decorative post top lantern 40 watts 230 volts, 50 HZ, mushroom or oval shaped in sothing opal/ prismatic finish made up of polycarbonate, suitable for 40 watt LED, all accessories prewire.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9 (iv) Contractor shall submit LM 79 and LM 80 test reports from manufacturer NABL accredated laboratory. |
| 26 | S&F in repairs cable of size 10 sqmm, twin core multistranded 1100 volts grade heavy dutyPVC insulated aluminiun conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspended with galavnised steel wire, complete all as specified and directed. |
| 27 | Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays complete all as specified and directed. |
| 28 | Excavation in trenches in any type of soil n. exc. 1.5 m in width and exc. 1.5 m but n. exc. 3 m in depthand getting out all as required for laying of cables, foundation filling of poles or stays complete all as specified and directed. |
| 29 | Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required complete all as specified and directed. |
| 30 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & directed |
| 31 | Supply and laying of DWC (Double wall Corrugated) pipe of 75mm bore as per IS-16205 laid for protection of cables in trenches completed all as specified and directied. |
| 32 | Supply and laying of DWC (Double wall Corrugated) pipe of 63mm bore as per IS-16205 laid for protection of cables in trenches completed all as specified and directied |
| 33 | Material and Labour for PCC 1:4:8 (nominal mix) type D-1(using 40mm graded crushed stone aggregates) as in coping of polecomplete all as specified and directed. |
| 34 | Material and Labour for PCC 1:3:6 (nominal mix) type C-1(using 40mm graded crushed stone aggregates) as in coping of polecomplete all as specified and directed. |
| 35 | Relaying only in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated, armoured heavy duty electric cable, with aluminium conductor of size 6 Sqmm x 2 core from trenches or fixed to wall/pole or passing through ducts or pipe of any sizeany core complete all as specified and directed. |
| 36 | Description all as per srl item No. 33.00 here in beforebut 10 Sqmm 2 core size. |
| 37 | Description all as per srl item No. 33.00 here in before16 Sqmm 2 core size. |
| 38 | Description all as per srl item No. 33.00 here in beforebut 16 Sqmm 4 core size. |
| 39 | Description all as per srl item No. 33.00 here in beforebut 25 Sqmm 3.5 core size. |
| 40 | Description all as per srl item No. 33.00 here in beforebut 35 Sqmm 3.5 core size.. |
| 41 | Description all as per srl item No. 33.00 here in before but 50 Sqmm 3.5 core size. |
| 42 | Supply & fix in repairsin trenches or fixed to wall/pole or passing through pipeLT XLPE cable 1100 volts grade heavy duty, armoured, extruded insulation on alumn conductor multistand of any size upto 16 Sqmm 2 core complete all as specified and directed. |
| 43 | Description all as per srl item No. 37.00 here in before but 16 Sqmm 4 core. |
| 44 | Description all as per srl item No. 37.00 here in beforebut 25 Sqmm 4 core. |
| 45 | Description all as per srl item No. 37.00 here in beforebut 50 Sqmm 3.5 core. |
| 46 | Description all as per srl item No. 37.00 here in beforebut 95 Sqmm 3.5 core. |
| 47 | S&F in repairs GI tubing light grade 40 mm borefor passing through cables under the floor, along the wall or along the pole complete all as specified and directed. |
| 48 | S&F in repairs GI tubing light grade 80 mm borefor passing through cables under the floor ,along the wall or along the pole complete all as specified and directed. |
| 49 | M&L for shifting of PCC /steel pole from one location to other location after digging of earth and dismatling of PCC with the help of JCB and other connected accessories & removing accessories, refixed the pole with connected items and two coat of alternative green and white strips of 30cm each upto 1.5 Mtr height from coping /ground level using synthetic enamel paint. marking of the pole number with black enamel paint over yellow circle of dia 100mm. Repainting the remaining pole and iron parts i.e \"U\" clamps, channels etc above 1.5 mtr height by applying two coat of alumn paint, complete all as specified and directed. |
| 50 | M&L for scraping of old paint from the steel tubular pole 9 Mtr height without removing accessories and preparation of surfaces for repainting, repainting the pole with two coats of alternative green and white strips of 30cm each upto 1.5 Mtr height from coping / ground level using synthetic enamel paint,marking of the pole number with black enamel paint over yellow circle of dia 100mm, painting the remaining pole and iron parts i.e \"U\" clamps, channels etc above 1.5 mtr height by applying two coats ofpaint, complete all as specified and directed. |
| 51 | S&F in repairs electronic driver after taking down street light, ISI approved company made as per existing make and size for suitable for LED fittings of cap upto 45-90 watts any type and make, and refixing the same complete all as specified and directed. |
| 52 | S&F in replairselectronic driver ofLED security light after taking down street light, ISI approved company made as per existing make and sizesuitable for LED fittings of cap more than 100 to 150 watts any type and make, and refixing the same complete all as specified and directed. |
| 53 | S&F in repairs MCB single pole 240 volts, C series, any rating from 6 to 32 amps, with rupturing capacity 10 KA,including providing thimble for out going cablescomplete all as specified and directed. |
| 54 | S&F in repairs steel tubular swaged poles of9 metres long, type 410 SP-31 complete with cast iron base plate,clamps, bolt, nuts & screws as specified and painting internal surface with anti-corrosive paintand external surface painting up to 1.5 m height from base of poles with two coats of synthetic enamel paint Ist quality green and white colour alternate strip 30 cm wide over a coat of red oxide primer and remaing portion with two coats of aluminum paint over a coat of red oxide primercomplete all as specified and directed. Note:-Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately. |
| 55 | Supply and erecting in repairs prestressed concrete pole, 9 m long, 102 mm x172 mm at top and 102 mm x 279 mm at bottom, class 10 including Zebra painting to PCC poles up to 1.5 m height from base of poles with two coats of synthetic enamel paint Ist quality black & yellow colour alternate strip 30 cm widecomplete all as specified and directed. Note:- Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately. |
| 56 | M&L forearthing with steelearth plate electrode ofsize 60cmx60cmx6mm thick buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 25x4mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI medium grade watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in electrical plate No 3 of SSR Part-Icomplete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. |
| 57 | Trimming up of tree branches upto 3 metre all around LT overhead lines andremoving cut branches from sitecomplete all as specified and directed.Note : (i)The overhead lines will be kept clear form all trees by trimming of tree branches with 3 M all around the line.Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department accordingly.The trimming work shall be commenced once it is permitted by AGE in writing(ii) Total length of line from one pole to another adjustingwill be measured as one span for the purpose of payment, irrespective of the No of trees required to be trimmed.No claim whatsoever shall be entertained by the deptt at later stage.(The approximate length of one span is 30 to 50 m) . T&P shall be arranged by contractor. |
| 58 | M&L for painting of PCC pole 9 mtr height without removing accessories with one coat ofalternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamell paint,marking the pole number with black synthetic enamel paint over yellow circle of dia 100mm,painting the steel parts i.eclamps, channels etc by applying two coat of alumn paintall as required at site,complete all as specified and directed. |
| 59 | S&F in replairs of surge protection device of cap 10 KA after taking down street light, ISI approved company made as per existing make and size,suitable for LED fittings of cap upto 150 watts any type and make, and refixing the same complete all as specified and directed. |
| 60 | M&L as in repairs mild steel cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat & two coats of aluminium paint including dismantling from pole complete all as specified and directed. |
| 61 | Re-stretching/Re-stringing of existing over head line ACSR/copper conductor of LT type on existing PCC/steel pole including 22 gauge aluminium binding wire, line connectors jumpers etc. including connections of incoming and outgoing cables, binding with spacers where requiredcomplete all as specified and directed. NOTE:- (a) For measurement purpose distance between centre of adjacent pole will be considered. (b) Contractors quoted rate is inclusive of rejointing of ACSR/Copper conductor if damaged during restraining. |
| 62 | Dismantling of ACSR conductors of any size from LT poles and removing from site complete all as specified and directed. |
| 63 | M&L for ACSR conductor (Weasel conductor 6 x 2.59 + 1 x 2.59 Al + Steel), of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables, including dismantling and taking down carefully existing old ACSR conductor/GI wire of any size from HT/LT overhead line complete all as specified and directed. Note:- For the purpose of paymenmt 3% for sag shall be added. |
| 64 | S&F in repairs GI wire4mm diadrawn straight horizontal as continuous earth wire on poles or fabrication of cradles complete all as specified and directed. |
| 65 | Dismantling insulators any type, any size and keeping serviceable insulators aside for reuse removing unserviceable insulators from site complete all as specified and directed. |
| 66 | S & F Pin type, polymer type, insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts gradecomplete all as specified and directed. |
| 67 | S & F Shackle insulators porcelain, vitreous, white,brown or green insulator including one set of galvanised mild steel section of straps 31 x3 mm, dia of bolt 12mm alongwith iron washers and one galvanised iron nut, 75mm height, 95mm dia for 1100 volts grade all as specified and directed. |
| 68 | Supply & fix junction box of size 260x160x250mm made out of 3.15 mm thick CRCA sheet powder coated front door openable with fixing arrangement by nut and bolts including 63 Amp having four No of aluminium bus bar mounted on epoxy based post insulators and drilled holes for including MCB SP 6 Amps-01 No all as required and fixed to poles using MS clamp of size 32x6mm and including nuts, bolts and washers connected electricallyas required at sitecomplete all as specified and directed. |
| 69 | M&L for tighting the loose coversof fittings, setting rubber beads, screws,nuts, bolts, clamp of brackets etc. of street / flood light fitting / gate lights LED fittings any type / watt on poles / walls / high mast, and tightening of, all loose electric connections of steet light / junction boxcomplete all as specified and directed. Note: 1. T&P shall be provided by the contractor and the rate quoted shall include the cost thereof. |