| 1 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 2 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required |
| 3 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
| 6 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 7 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 8 | Supply of PVC insulated and FR PVC Sheathed multicore copper conductor 1.1KV grade, conforming to grade IS 694 as required . 3*1.5 Sq.mm |
| 9 | Supplying and erection of galvanized D-iron complete with shackle insulator (100 mm x 110 mm) GI bolt and nut coach screws etc as required. |
| 10 | Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable 1.1 KV grade Conforming to IS 7098/1988 of following Sizes 2 X10 SQmm. |
| 11 | Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable 1.1 KV grade Conforming to IS 7098/1988 of following Sizes 4X16 sqmm |
| 12 | Drilling and laying i/c HDPE pipe of 40 mm outer dia with PN 4 rating by hand moling /manual methodConfirming to IS 4984. |
| 13 | Dismantling of pole/ street light standard/ strut embedded in brick ballast foundation etc. as required. |
| 14 | Fabrication, supply and erection of7.0 mtr height, 3 mm thick, bottom dia of 130mm and top dia of 70 mm base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor- 4 nos. and shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length, 6 Amp. SPMCB\"C\" Curve characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be either embossed or Rivited plateon the pole. Galvanization as per relevant IS code etc. as required. |
| 15 | Providing and laying in position M25 grade reinforced cement concrete foundation of size 600 mm (L) x 600 mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1600 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 20 mm dia,700/750 mm long, J type i/c 2 nos. template anchor plates of size 225mmx225mmx3mm and providing DCW HDPE for cable entry and exit as required for 7 m. and 8 mtr pole. |
| 16 | Fabrication, supply & erection of 5.0 mtr height, minimum 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate,window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd,terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ characteristics, earth stud, cable support clamp suitable for 4x25 sqmm cable.Logo/Name of manufacturer shall be embosed on the pole, galvanization as per relevant IS codde etc as required. |
| 17 | Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L) ×450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1400 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DWC HDPE for cable entry and exit as required for 3 m and 5 mtr pole. |
| 18 | Fabrication supplyiing and fixing class B Galvanised double overhang arm bracket made out of 250 mm long galvanized top tube with cap & 1000 mm long 40 mm dia galvanized pipe with tightening bolts complete as reqd. |
| 19 | Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 40 mm dia galvanised pipe with tightening bolts complete as required. |
| 20 | LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy >135 lm/Watt) .Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection,EMIEMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 45 Watt. |
| 21 | S.I.T.C of Hot Press moulded SMC panel/Canopy Box of size(OD) 920 mm x 460 mm x 260 mm & (ID) 900 mm x 450 mm x250 mm , anti – corrosive, dust proof, rust proof, shock proof , Self-extinguishing property , resistant to heat , Vermin proof, Ultra Violet stabilized, Pilfer resistant, Suitable for mounting 1 no. 3 phase Starter, 1 no. 63 Amp 4 pole isolator and 1 no. 3 phase Energy meter, Socket for outgoing connection with pilferage proof SMC door duly welded with S/S handle having danger logo on its outer surface and with 1 no Hot Dip galvanized iron stand for a base of size 40 mm x 40 mm x 5 mm and height of the stand is 600 mm including 300 mm height below the ground with side strip of size 25 x 5 mm. |
| 22 | SITCof Pillar box size 900 mm x 450mm x 250mm suitable for mounting incomer of 250 A MCCB/Main switch 4 Pole and energy meter 3 phase complete with eleethoypic grade Aluminium bus bar of size 25mm x 19 mm mounted on galvanized M. S. body power quoted pilferage proof SMC door duly welded with S.S. withrain cover size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below groundand covered with shade proof SMC sheet of 3 mm as required. |
| 23 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreadersin existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100Amp, 30KA, FPMCCB. |
| 24 | Supplying and fixing 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole. |
| 25 | Providing and Fixing name board made of MS Sheet 90x60 cm , 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back of the sheet of MS flat 40x6mm, total height of the board above groundlevel 2.40m, length of legs below ground0.30m embeded in CC block 1:2:4(1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size) 30x30x45cm including excavation and removal of surplusearth with in 50m lead, applying primary coat of approved steel primer, painting with synthetic enamel point of approved quality and lettering with enamel paint of approved colour (one side)as per drawing /direction of Engineer in charge. |
| 26 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |