| 1 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50m and lift up to 1.5m Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 2 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 3 | Supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 4 | Cement Concrete 1:4:8 (One Cement, Four Sand and Eight hard broken stone aggregate) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specificationIncluding cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columnsIncluding cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level TMT Bars ; Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 7 | Reinforced Cement Concrete 1:1½:3 (One Cement, One and a half sand and Three hard broken stone aggregate) using 20 mm gauge hard broken granite stone aggreagate for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper & Blocks laid over it without claiming extra, etc., complete complying with standard specification. Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 8 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 Cement mortar 1:6 (1 cement : 6 coarse sand) Coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all liftIncluding cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form work for Columns, piers, abutments, pillars, posts and strutsIncluding cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level TMT Bars From Item No.12 RCC 1 : 1½ : 3Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 13 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 15 | Cement concrete flooring 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 16 | Plastering with cement mortar 1:5 (1 cement : 5 coarse sand) on brick/stone masonry or concrete surfaces, including surface preparation, raking of joints, cleaning and wetting, applying plaster to the specified thickness, finishing smooth and even, curing complete, including cost of materials, labour, scaffolding and all incidental charges,and directions of the Engineer-in-Charge. |
| 17 | Special ceiling plastering and finishing all the RCC exposed surfaces such as RCC Slabs sunshade, canopy, staircase steps, landing slab etc., with cement mortar 1:3 [One cement and three M-sand] 10mm thick including hacking the surface and providing cement mortar noising beading wherever necessary using the same mix as directed by the departmental officers etc., complete complying with standard specifications.Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 18 | Painting two coats of newly plastered ceiling surface with White washing with lime to give an even shade Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 20 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 21 | Providing and laying integral cement based waterproofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
| 22 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1cement : 4 coarse sand) and finished neat complete. Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 23 | Providing and laying matt finished vitrified tile of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 24 | Provision for plumbing work with necessary fittings, including supply, installation, testing and commissioning of complete plumbing system, inclusive of cost of materials, labour charges, conveyance, tools & plants, scaffolding, cutting and making good, testing and all incidental charges, complete, as per specifications and directions of the Engineer-in-Charge.Supplying and fixing in position White / Colour Special Delux Model Glazed Cascade Type Parryware / Hindware / Equivalent Wall Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections,15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) with 10 litres capacity flushing tank with all internal dual flush fittings with normal seat cover Wall Fitting Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 25 | Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 26 | Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) |
| 27 | Supplying and fixing of 1000 litres capacity PVC water tank with IS specification IS 10701/96 the tank is meant for outdoor (or)indoor use complete with removable hinged top locking arrangement and to make provision to fix water supply pipe lines, necessary man hole with cover and etc. (The water tank should be got approved by the engineer incharge before use on work) Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 28 | Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers including cost of all labour charges tools and incidental charges etc complete as directed by the Engineer in charge. |
| 29 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 30 | Supplying and erecting in position of 500 liters capacity Industrial Model Reverse Osmosis Water-cum- Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories.(a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP 1 No.(d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch- 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works ,wherever necessary to install the System in position and intact. Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 31 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works) |
| 32 | Wiring with 2x1.5sq.mm.PVC insulated unsheathed FRL SSC copper conducto rof 1100V grade insuitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and SAFT switch inflush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator)Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 33 | Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm Metal switch box with suitable top cover for 5 A 3 pin non inter locking CS Modular Plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 34 | Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colourIncluding cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 35 | Wiring with 2x4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade insuitable pipe concelaed with PVC accessories with 150mm x100mmx113mm TW switch box for 15A 3pin non inter locking wall socket with 15A flush type switch with painting of suitable colour with continuous earth wire connection of 4 sq.mm copper wire for open PVC power plug point Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 36 | Supply and fixing of fancy glass shade and 11W CFL for BH point.Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 37 | Supply and fixing of single box type 4\"36 W flu fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting. Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 38 | Supply and fixing of 1 x 45w 4U Retro CFL B22 type street light fitting complete with 19mm dia GI pipe (class “B”) on the existing post / wall with PVC unsheathed copper leads MS clamps and aluminium painting with CFL (CG / Philips or Equivalent)Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 39 | Supply and fixing of 4’ 40 W Twin Mirror optic suspension type fitting (Philips / Crompton / Wipro) complete with louvers cover complete with copper choke and condensor with conduit pipe suspension, with PVC unsheathed Copper leads from the terminals to the fittings with flu. tubes (SD-96)Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 40 | Supply & Fixing of AC / DC 76mm Buzzer /caII bell suitable for 230 Volts 50 cis single phase AC supply on suitable TW Board with push switch. Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 41 | Supply and fixing of 3 Nos. 5Amps (3 Pin and 2 Pin) combined flush type wall socket with control switches concealed in suitable TW Boxcovered with Hylem sheet in flush with wall with earth connection (For Computer Plug Socket) Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 42 | Supply and fixing of 20Amps DP Plug and Socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug) [Legrand (MDS) / Hager (L&T) make] Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 43 | Supply and fixing of 63A TPN MC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only.Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosureDistribution board 1No 32 Amps DB MCB as incoming and 6 Nos 6 Amps to 32 Amps SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB\"s should be with ISI mark (Like Standard make). Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 44 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure Distribution board 1No 32 Amps DB MCB as incoming and 6 Nos 6 Amps to 32 Amps SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB\"s should be with ISI mark (Like Standard make). Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 45 | Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40A 4 pole MCB isolater as incoming and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB\"s should be with the ISI mark (like standard make) Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 46 | Supply and laying of 31/2 X 50 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 47 | Supply and clamping of 31/2x50 mm PVC ctvg ARMOURED CABLE ON SUITABLE on post or on wall with MS Clamps Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 48 | Supply and fixing of 2x36w CFL type street light fitting with complete with 32mm dia G.I. pipe class ’B with 1 No 32mm G.I. Bend complete on the existing post / well with 16A aerial fuse unit on MS plate with PVC unsheathed copper leads, MS clamps and aluminium paiting with 2 Nos 36w CFL. (Make CG SCE 13236EB / equivalent)Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 49 | Earthing as per the ISI specification with an earth electrode of 2.1mt class \"B\" GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 50 | Providing and fixing UPVC (Unplasticized Polyvinyl Chloride) casement type openable windows of size 0.60 m × 0.90 m (0.54 Sqm each), made from multi-chambered UPVC profiles having minimum 2 mm wall thickness, with outer frame size 60 mm × 58 mm and shutter profiles reinforced with 1 mm thick GI reinforcement (minimum 125 GSM zinc coating), fully corrosion-free, complete. The windows shall be provided with EPDM rubber gaskets (black colour) all around the frame and shutter, Espag multi-point locking system with handle operation, key-lockable security hinges and strong locking arrangement to reduce noise and energy loss. Corners and joints shall be fusion welded, cleaned and finished properly. Glazing shall be 4 mm thick radiation-free pin-headed plain or brown coloured glass, securely fixed to the shutter and watertight even during heavy rains and storm conditions. The window shall be fixed to the wall opening with proper alignment, 100% packing, screws and silicone sealant all around the frame, ensuring smooth operation of the sash. All materials shall be of approved make and the window shall be got approved by theEngineer in charge before use on work, complete in all respects including cost of materials, labour, fittings, conveyance and installation, Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 51 | Providing and fixing UPVC (Unplasticized Polyvinyl Chloride) louvered ventilators of approved make and quality, manufactured from multi-chambered UPVC profiles having minimum wall thickness of 2 mm, with outer frame size 60 mm × 58 mm and shutter profile size 60 mm × 78 mm, both profiles reinforced with 1 mm thick GI reinforcement with minimum 125 GSM zinc coating, fully corrosion-free. The ventilators shall be provided with EPDM rubber gaskets (black colour) all around the frame and shutter edges. The corners and joints of the profiles shall be fusion welded, properly cleaned and finished. The louvers shall be fitted with 4 mm thick radiation-free pin-headed glass securely fixed in position. The ventilator shall be fixed to the wall opening with proper alignment, 100% packing, screws and silicone sealant all around the frame to ensure a firm and watertight installation. All materials shall be of approved make and the ventilator shall be got approved by the Executive Engineer before use on work, complete in all respects including cost of materials, labour, fittings, conveyance and installation, |
| 52 | Providing and fixing 35 mm thick factory-made pre-laminated ABS (Acrylonitrile Butadiene Styrene) door shutters of approved make and design, moulded in different patterns, complete with all fittings and accessories. The door shutter shall consist of an all-round frame made of waterproof solid foam PVC bars of size 20 mm × 32 mm, reinforced with 32 mm × 32 mm LVL (Laminated Veneer Lumber) vertical members (2 Nos.). The core shall be of 32 mm thick high-density craft paper honeycomb board, sandwiched on both sides with 1.5 mm thick pre-laminated ABS sheets, and finished with 0.45 mm thick PVC edge banding on the vertical sides. The shutter shall be provided with steel-coated butterfly hinges (3 Nos. per shutter) and ISI-marked stainless steel round lock, complete. The rate shall include cost of materials, labour, fittings, conveyance, installation and finishing, complete in all respects and complying with standard specifications. The door shutter and frame shall be got approved by the Engineer incharge before use on work Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 53 | Providing and fixing UPVC / solid PVC door shutters or partition walls with jambs, complete with all fittings and accessories, as per approved specifications and directions of the Engineer-in-Charge. The shutter and frame shall be fabricated using 19 gauge, 19 mm MS square tubes for styles and outer frames, and 15 mm MS square tubes for top rail, lock rail and bottom rail. The steel members shall be fully covered with 5 mm thick solid PVC sheets. The shutter panelling shall be made of 5 mm thick solid PVC sheets, rigidly fixed in position. The overall size of styles shall be 50 mm × 30 mm, the overall size of top rail, lock rail and bottom rail shall be 75 mm × 30 mm, and the overall size of frames shall be 50 mm × 45 mm, provided with suitable rebate for housing the shutter. The work shall include supplying and fixing of all necessary furniture and fittings, complete. All materials shall be of approved make and quality, and the shutter, partition and frame shall be got approved by the Engineer in charge before use on work, complete in all respects including cost of materials, labour, fittings, conveyance and installation, |
| 54 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia (unplasticized PVC medium well screen (RMS) pipes )Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 55 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge |
| 56 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 57 | Supplying Assembling lowering and fixing the Submersible Motor 2HP Texmo with starter in vertical position (Local Market) Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 58 | Excavation work by mechanical means (Hydraulic excavator)/ manual means including cost of all materials and hirecharges of tools and plants etc complete.as directed by the engineer in charge |
| 59 | Supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 60 | Cement Concrete 1:2:4 (One Cement, Two sand and Four hard broken stone aggregate) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification including cost of all labour charges tools and incidental charges etc complete as directed by the Engineer in charge. |
| 61 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4including cost of all labour charges tools and incidental charges etc complete as directed by the Engineer in charge. |
| 62 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns including cost of all labour charges tools and incidental charges etc complete as directed by the Engineer in charge. |
| 63 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Including cost of all materials, conveyance, loading and unloading, labour, hire charges, fuel, tools and plant, all applicable taxes, and incidental charges, complete as directed by the Engineer-in-Charge |
| 64 | Supplying and providing Thermo-Mechanically Treated bars of grade Fe-500D or more including cost of all labour charges tools and incidental charges etc complete as directed by the Engineer in charge. |
| 65 | Plastering with cement mortar 1:3 (1 cement : 3 coarse sand) on brick/stone masonry or concrete surfaces, including surface preparation, raking of joints, cleaning and wetting, applying plaster to the specified thickness, finishing smooth and even, curing complete, including cost of materials, labour, scaffolding and all incidental charges, and directions of the Engineer-in-Charge. |
| 66 | Supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. including cost of all labour charges tools and incidental charges etc complete as directed by the Engineer in charge. |
| 67 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer in-charge. |
| 68 | Removing the old paint by scrapping, sand papering and preparing the surface smooth and Painting the surface with two coats of enamel paint including cost of all materials and labour cost etc., complete. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail