| 1 | Site clearing and clearance including removing tree all complete. |
| 2 | Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap): 450mm dia piles. DSR.20.3.3 |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.DSR-2023, 2.6. |
| 4 | Provinding and laying cement concrete 1:4:8 (1 Cement: 4 coarse sand derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources).DSR-2023, 4.1.8. |
| 5 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).DSR-2023, 5.2.2 |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).DSR-2023, 5.3 |
| 7 | Mild steel or iron in plan work such as reinforced concrete or reinforced brick work wrought to required shape as necessary including bending for proper completion of the work. All complete S.I.No. 504 |
| 8 | M150 brick work Designation 7.5 in foundation and plinth in: Brick work with common burnt clay F.P.S. (non modular) bricks of class.DSR-2023,6.1.1. |
| 9 | 12mm thick plaster in 1:3 cement and coarse sand mortar. All complete. DSR-2023, 13.4.1. |
| 10 | Excavating, supplying, stacking and filling of local earth (including royalty) b mechanical transport upto a lead of 5km allso including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. DSR 2023 2.25(a) |
| 11 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on preared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achive the desired denisty, complete as per Technical Specification clause 401. |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: (1 Cement: 1½ coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR.2023- 4.1.2. |
| 13 | Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with Double armbracket (1 Mtr length each ) on RCC foundation including the cost of foundation, foundation bolts, |
| 14 | excavation & back filling and Required T&P completee in all respect. |
| 15 | S/L of Aluminium conductor PVC insulated Un- Armoured cable 1100 V 16 Sq.mm 02 Core ISI Approve Complete all respect (M.R.) |
| 16 | S/F of LED Factory wired integral LED flood Light luminaries with ndriver set suitable forn200 watt. Comfirming to IP-66 protection complete in all respect CAT-AAA As per PWD shedule 2018 sor no 1455 |
| 17 | Supply and Fixing of 25bamp. TPN capacityn of automatic street light, cubical control panel painted with anti consisting of time switch TSO 100 Series with contactor, HRC fuses isolating switch metering instrument & instrument box with CTs etc. in case of TPN complete in all respect. PWD shedule 2018 sor no 807-(E II) |
| 18 | S/F of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Double armbracket length 1 mtr. length in 1:2:4 RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect. As per PWDshedule 2024 SOR No. 21.2 |
| 19 | S/F of LED Street light fitting with mandatory driver set having die cast aluminium body with toughendglass/UV stablized PC cover and lenses suitable for 120 Watt. and Confirming to IP-66 protection and IK 07 and above protection having company LOGO Engraved complete in all respect. CATAAA, As per PWD shedule 2024 SOR No.23.17 |
| 20 | S/L of 15mm dia pvc pipe etc. Complete in all respect. (MR) (Class B) |
| 21 | Supply and laying of 16 sq. mm 2 core aluminium conductor PVC insulatedarmoured served sheathed cables1100V grade at depth of 750mm belowground level over cushion of 75mmthick sand all around and protected with burnt bricks on sides and on top. etc.complete in all respect. As per PWD shedule 2024 SOR No.20.1.3 |
| 22 | S/F of junction plate housing brass terminal mica sheet 10 Amp 1-P MCCB (MR) |
| 23 | S/F Distribution fuse board Neutral link four pole with 32 Amp. MCB complete in all respect (MR) |
| 24 | S/F of 40 AMP TPN capacity of automatic street light cubicle control panel complete in all respect (PWD-2018, SI No. 807(f) II) |
| 25 | S/L 1.5 mm 3 Core Copper wire for connection of LED light. From LED light to distribution fuse board complete in all respect ISI Mark (MR) |
| 26 | S/B of G.I. Pipe Earthing complete in all respect (PWD-2018 S.I. 701) |
| 27 | S/F of 16 sq. mm plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. Complete in all respect as per PWD shedule 2018 SOR No 504 (D) |
| 28 | Providing and fixing Stainless steel 3 Sheater Bench. All complete. (as per Market Rate) |
| 29 | Construction fo Padustrial board oapproved quality and as per direction of E/I including all complete (AR) Please Enable Macros to View BoQ information |