Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth: for foundationetc or for manholes, laying of pipe in any type of soil and getting out complete all as specified |
| 2 | Returning filling in, including spreading, leveling watering & well rammng in layers not exc 25cm thick complete all as specified and directed by EIC |
| 3 | Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & diected |
| 4 | Taking up CI/ DIpipe (including all fittings) with spigot and socket ends centrifugally cast 100 mm bore laid in trenches completeall as specified and directed by Engineer - in - Charge. |
| 5 | Taking up CI/ DIpipe (including all fittings) with spigot and socket ends centrifugally cast 150 mm bore laid in trenches completeall as specified and directed by Engineer - in - Charge. |
| 6 | Taking up CI/ DIpipe (including all fittings) with spigot and socket ends centrifugally cast 200 mm bore laid in trenches completeall as specified and directed by Engineer - in - Charge. |
| 7 | Supplying, laying, jointing, commissioning and testing of ductile iron pressure pipe with socket & spigot ends having ISImarking confirming to IS:8329/2000 in standard lengths of classification K-9 suitable for and includingpush on rubber tyton joint (gasket D-jointing) with cement mortar lining in the pipes having 100 mm bore, including aligning the pipes inside trench as per IS:12288/1987 and testing the joints with required water pressure complete all as specified & directed. |
| 8 | Supplying, laying, jointing, commissioning and testing of ductile iron pressure pipe with socket & spigot ends having ISImarking confirming to IS:8329/2000 in standard lengths of classification K-9 suitable for and includingpush on rubber tyton joint (gasket D-jointing) with cement mortar lining in the pipes having 150 mm bore, including aligning the pipes inside trench as per IS:12288/1987 and testing the joints with required water pressure complete all as specified & directed. |
| 9 | Supplying, laying, jointing, commissioning and testing of ductile iron pressure pipe with socket & spigot ends having ISImarking confirming to IS:8329/2000 in standard lengths of classification K-9 suitable for and includingpush on rubber tyton joint (gasket D-jointing) with cement mortar lining in the pipes having 200 mm bore, including aligning the pipes inside trench as per IS:12288/1987 and testing the joints with required water pressure complete all as specified & directed. |
| 10 | Cutting to existing CI/DI pipe line of size 100mm bore required for repair/replacement of pipe line and insertion of collars/tail pieces, tee etc including dewatering of pit if any complete all as specified and directed. Note : Excavation and earth work if any shall be measured and paid for separately. |
| 11 | Cutting to existing CI/DI pipe line of size 150mm bore required for repair/replacement of pipe line and insertion of collars/tail pieces, tee etc including dewatering of pit if any complete all as specified and directed. Note : Excavation and earth work if any shall be measured and paid for separately. |
| 12 | Cutting to existing CI/DI pipe line of size 200mm bore required for repair/replacement of pipe line and insertion of collars/tail pieces, tee etc including dewatering of pit if any complete all as specified and directed. Note : Excavation and earth work if any shall be measured and paid for separately. |
| 13 | S & F ductile iron pipe fittings such as bends, tapers, tee pieces single branch, \"Y\" junction, collars, caps and plugs etc spigot socketed or flanged ends type of size up to 150mm nominal bore conforming to IS-9520/2000 with pressure rating PN-1 (all the fittings shall be coated for rust prevention i.e. external coating zinc rich paint with finishing layer of bituminous as per Annexure - A of IS:9523/2000 and internal lining shall be of cement mortar with seal coat as per Annexure \"B\" of IS-9523/2000) complete all as specified and directed by Engineer - in - Charge.Note: (i) Joint and jointing material shall be measured and paid separately. (ii) Excavation and earth work shall be measured and paid for separately. |
| 14 | S & F ductile iron pipe fittings such as bends, tapers, tee pieces single branch, \"Y\" junction, collars, caps and plugs etc spigot socketed or flanged ends type of size 200mm to 600mm nominal bore conforming to IS-9520/2000 with pressure rating PN-1 (all the fittings shall be coated for rust prevention i.e. external coating zinc rich paint with finishing layer of bituminous as per Annexure - A of IS:9523/2000 and internal lining shall be of cement mortar with seal coat as per Annexure \"B\" of IS-9523/2000) complete all as specified and directed by Engineer - in - Charge.Note: (i) Joint and jointing material shall be measured and paid separately. (ii) Excavation and earth work shall be measured and paid for separately. |
| 15 | M&L as in repairs Run lead joint suitable for 80mm bore spigot and socketed pipes and fittingscomplete all as specified and as directed by Engineer-in-Charge. |
| 16 | M&L as in repairs Run lead joint suitable for 100mm bore spigot and socketed pipes and fittingscomplete all as specified and as directed by Engineer-in-Charge. |
| 17 | M&L as in repairs Run lead joint suitable for 150mm bore spigot and socketed pipes and fittingscomplete all as specified and as directed by Engineer-in-Charge. |
| 18 | M&L as in repairs Run lead joint suitable for 200mm bore spigot and socketed pipes and fittingscomplete all as specified and as directed by Engineer-in-Charge. |
| 19 | M&L as in repairs Run lead joint suitable for 250mm bore spigot and socketed pipes and fittingscomplete all as specified and as directed by Engineer-in-Charge. |
| 20 | M&L as in repairs Run lead joint suitable for 300mm bore spigot and socketed pipes and fittingscomplete all as specified and as directed by Engineer-in-Charge.Note (for item 15 to 20):-1. Earthwork shall be measured and paid separately. |
| 21 | M&L for cocking of Lead wool in leaked joints of 80mm bore spigot and socketed cast iron pipecomplete including necessary testing for leakage all as specified and as directed by Engineer-in-Charge. |
| 22 | M&L for cocking of Lead wool in leaked joints of 100mm bore spigot and socketed cast iron pipecomplete including necessary testing for leakage all as specified and as directed by Engineer-in-Charge. |
| 23 | M&L for cocking of Lead wool in leaked joints of 150mm bore spigot and socketed cast iron pipecomplete including necessary testing for leakage all as specified and as directed by Engineer-in-Charge. |
| 24 | M&L for cocking of Lead wool in leaked joints of 200mm bore spigot and socketed cast iron pipecomplete including necessary testing for leakage all as specified and as directed by Engineer-in-Charge. |
| 25 | M&L for cocking of Lead wool in leaked joints of 250mm bore spigot and socketed cast iron pipecomplete including necessary testing for leakage all as specified and as directed by Engineer-in-Charge. |
| 26 | M&L for cocking of Lead wool in leaked joints of 300mm bore spigot and socketed cast iron pipecomplete including necessary testing for leakage all as specified and as directed by Engineer-in-Charge.Note (for item 21 to 26):-1. Earthwork shall be measured and paid separately. |
| 27 | Taking out 80 mm bore sluice valve top cover, spindle and broken / unserviceable check nut (gutka)carrying away to workshop & refixing ofsluice valve after servicing /maintenance /grinding / cleaning / threading / greasingwork of sluice valve parts, including replacement of gland packing, rubber sheet, nuts, bolts, spindle ,check nut and washer of existing size completeall as specified and directed by Engineer - in - Charge. |
| 28 | Taking out 100 mm bore sluice valve top cover, spindle and broken / unserviceable check nut (gutka)carrying away to workshop & refixing ofsluice valve after servicing /maintenance /grinding / cleaning / threading / greasingwork of sluice valve parts, including replacement of gland packing, rubber sheet, nuts, bolts, spindle ,check nut and washer of existing size completeall as specified and directed by Engineer - in - Charge. |
| 29 | Taking out 150 mm bore sluice valve top cover, spindle and broken / unserviceable check nut (gutka)carrying away to workshop & refixing ofsluice valve after servicing /maintenance /grinding / cleaning / threading / greasingwork of sluice valve parts, including replacement of gland packing, rubber sheet, nuts, bolts, spindle ,check nut and washer of existing size completeall as specified and directed by Engineer - in - Charge. |
| 30 | Taking out 200 mm bore sluice valve top cover, spindle and broken / unserviceable check nut (gutka)carrying away to workshop & refixing ofsluice valve after servicing /maintenance /grinding / cleaning / threading / greasingwork of sluice valve parts, including replacement of gland packing, rubber sheet, nuts, bolts, spindle ,check nut and washer of existing size completeall as specified and directed by Engineer - in - Charge. |
| 31 | Taking out 250 mm bore sluice valve top cover, spindle and broken / unserviceable check nut (gutka)carrying away to workshop & refixing ofsluice valve after servicing /maintenance /grinding / cleaning / threading / greasingwork of sluice valve parts, including replacement of gland packing, rubber sheet, nuts, bolts, spindle ,check nut and washer of existing size completeall as specified and directed by Engineer - in - Charge. |
| 32 | Supply and fixingas in repairs CI sluice valve flanged type rating PN 1.6 size 80mm with brass spindle, gate with brass ring andhand wheel completejointing necessary gasket, nuts, bolts and washers etc. includingtesting for leakage all as specified and directed by Engineer – in – Charge. |
| 33 | Supply and fixingas in repairs CI sluice valve flanged type rating PN 1.6 size 100mm with brass spindle, gate with brass ring andhand wheel completejointing necessary gasket, nuts, bolts and washers etc. includingtesting for leakage all as specified and directed by Engineer – in – Charge. |
| 34 | Supply and fixingas in repairs CI sluice valve flanged type rating PN 1.6 size 150mm with brass spindle, gate with brass ring andhand wheel completejointing necessary gasket, nuts, bolts and washers etc. includingtesting for leakage all as specified and directed by Engineer – in – Charge. |
| 35 | Supply and fixingas in repairs CI sluice valve flanged type rating PN 1.6 size 200mm with brass spindle, gate with brass ring andhand wheel completejointing necessary gasket, nuts, bolts and washers etc. includingtesting for leakage all as specified and directed by Engineer – in – Charge. |
| 36 | Supply and fixingas in repairs CI sluice valve flanged type rating PN 1.6 size 250mm with brass spindle, gate with brass ring andhand wheel completejointing necessary gasket, nuts, bolts and washers etc. includingtesting for leakage all as specified and directed by Engineer – in – Charge. |
| 37 | Supplying and fixing as in repairs ductile iron sluice valve flanged type rating PN 1.6 size 80mm bore conforming to IS-14846 with wheel, necessary gasket, nuts, bolts and washers etc. and jointing including testing for leakage completeall as specified and directed by Engineer – in – Charge. |
| 38 | Supplying and fixing as in repairs ductile iron sluice valve flanged type rating PN 1.6 size 100mm bore conforming to IS-14846 with wheel, necessary gasket, nuts, bolts and washers etc. and jointing including testing for leakage completeall as specified and directed by Engineer – in – Charge. |
| 39 | Supplying and fixing as in repairs ductile iron sluice valve flanged type rating PN 1.6 size 150mm bore conforming to IS-14846 with wheel, necessary gasket, nuts, bolts and washers etc. and jointing including testing for leakage completeall as specified and directed by Engineer – in – Charge. |
| 40 | Supplying and fixing as in repairs ductile iron sluice valve flanged type rating PN 1.6 size 200mm bore conforming to IS-14846 with wheel, necessary gasket, nuts, bolts and washers etc. and jointing including testing for leakage completeall as specified and directed by Engineer – in – Charge. |
| 41 | Supplying and fixing as in repairs ductile iron sluice valve flanged type rating PN 1.6 size 250mm bore conforming to IS-14846 with wheel, necessary gasket, nuts, bolts and washers etc. and jointing including testing for leakage completeall as specified and directed by Engineer – in – Charge. |
| 42 | Demolition of brick work built in cement mortarall as specified and directed by Engineer - in - Charge. |
| 43 | M & L brick work with sub class ‘B’ old size burnt bricks straight or curved on plan exceeding 6.0m mean radius built in cement mortar 1:4 all as specified and directed by Engineer – in – Charge. |
| 44 | M&L for rendering 15mm thick on fair face of brick work in CM 1:4 finished aven and smooth complete all as specified and directed. |
| 45 | M & L as in repairs for framed work for valve pit chamber covermade of MS equal angle and MS sheet 3 mm thick including welding, cutting, hinges, locking arrangments including paintingcomplete all as specified and directed. |
| 46 | M & L cement concrete (1:2:4)type B-1 using 20mm graded stone aggregate as in lintels up to 1.5 m clear span, seismic and other similar bands, benching, coping, bed blocks, apex stones and kerbs etc including use of necessary form work all as specified and directed by Engineer - in - Charge . |
| 47 | Taking down steel tubing 100mm bore and connections including cleaning for refixing/ removal completeall as specified and directed by Engineer - in – Charge. |
| 48 | Taking down steel tubing 80mm bore and connections including cleaning for refixing/ removal completeall as specified and directed by Engineer - in – Charge. |
| 49 | Taking down steel tubing 50mm bore and connections including cleaning for refixing/ removal completeall as specified and directed by Engineer - in – Charge. |
| 50 | Taking down steel tubing 40mm bore and connections including cleaning for refixing/ removal completeall as specified and directed by Engineer - in – Charge. |
| 51 | Taking down steel tubing 25mm bore and connections including cleaning for refixing/ removal completeall as specified and directed by Engineer - in – Charge. |
| 52 | Taking down steel tubing 20mm bore and connections including cleaning for refixing/ removal completeall as specified and directed by Engineer - in – Charge. |
| 53 | Taking down steel tubing 15mm bore and connections including cleaning for refixing/ removal completeall as specified and directed by Engineer - in – Charge. |
| 54 | Refixing old steel tubing and connections in new or old position in trenches 100mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 55 | Refixing old steel tubing and connections in new or old position in trenches 80mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 56 | Refixing old steel tubing and connections in new or old position in trenches 50mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 57 | Refixing old steel tubing and connections in new or old position in trenches 40mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 58 | Refixing old steel tubing and connections in new or old position in trenches 25mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 59 | Refixing old steel tubing and connections in new or old position in trenches 20mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 60 | Refixing old steel tubing and connections in new or old position in trenches 15mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 61 | Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc.)25mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 62 | Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc.)20mm bore including all fittings all as specified and directed by Engineer - in - Charge. |
| 63 | Refixing old steel tubing and connections in new or old position (walls, ceiling, floors, etc.)15mm bore including all fittings all as specified and directed by Engineer - in - Charge.Note (for item 61 to 63):-1. Work will be executed upto (Ground+4 storey building). Necessary arrangement for replacement/ fixing of new pipe along the wall included inquoted amount. |
| 64 | S&F 100mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in trenches including taking down old existing pipe, all as specified and directed . |
| 65 | S&F 80mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in trenches including taking down old existing pipe, all as specified and directed . |
| 66 | S&F 50mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in trenches including taking down old existing pipe, all as specified and directed . |
| 67 | S&F 40mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in trenches including taking down old existing pipe, all as specified and directed . |
| 68 | S&F 25mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in trenches including taking down old existing pipe, all as specified and directed . |
| 69 | S&F 20mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in trenches including taking down old existing pipe, all as specified and directed . |
| 70 | S&F 15mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in trenches including taking down old existing pipe, all as specified and directed . |
| 71 | S&F 50mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in wall/ceiling/ floor including taking down old existing pipe, all as specified and directed . |
| 72 | S&F 40mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in wall/ceiling/ floor including taking down old existing pipe, all as specified and directed . |
| 73 | S&F 25mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in wall/ceiling/ floor including taking down old existing pipe, all as specified and directed . |
| 74 | S&F 20mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in wall/ceiling/ floor including taking down old existing pipe, all as specified and directed . |
| 75 | S&F 15mm boremedium grade steel tubes galvanized with all fittingincluding cutting threading connection in new or old positionfor laid in wall/ceiling/ floor including taking down old existing pipe, all as specified and directed .Note (for item 71 to 75):-1. Work will be executed upto (Ground+4 storey building). Necessary arrangement for replacement/ fixing of new pipe along the wall included inquoted amount. |
| 76 | S&F 110mm diameter 3- layered SDR 7.4 (PN-16) (outer green coloured UV stabilized, middle black coloured UV stabilized and inner most layer white coloured with antimicrobial properly)PP-R (Poloyproplene randonCo-polymer) pipes laid in trenches incl plain PP-R and brass threaded PP-R fittings or flanged jointsincl connecting up with existingsystem all as specified and directed . |
| 77 | S&F 90mm diameter 3- layered SDR 7.4 (PN-16) (outer green coloured UV stabilized, middle black coloured UV stabilized and inner most layer white coloured with antimicrobial properly)PP-R (Poloyproplene randonCo-polymer) pipes laid in trenches incl plain PP-R and brass threaded PP-R fittings or flanged jointsincl connecting up with existingsystem all as specified and directed . |
| 78 | S&F 63mm diameter 3- layered SDR 7.4 (PN-16) (outer green coloured UV stabilized, middle black coloured UV stabilized and inner most layer white coloured with antimicrobial properly)PP-R (Poloyproplene randonCo-polymer) pipes laid in trenches incl plain PP-R and brass threaded PP-R fittings or flanged jointsincl connecting up with existingsystem all as specified and directed . |
| 79 | S&F 50mm diameter 3- layered SDR 7.4 (PN-16) (outer green coloured UV stabilized, middle black coloured UV stabilized and inner most layer white coloured with antimicrobial properly)PP-R (Poloyproplene randonCo-polymer) pipes laid in trenches incl plain PP-R and brass threaded PP-R fittings or flanged jointsincl connecting up with existingsystem all as specified and directed . |
| 80 | S&F 32mm diameter 3- layered SDR 7.4 (PN-16) (outer green coloured UV stabilized, middle black coloured UV stabilized and inner most layer white coloured with antimicrobial properly)PP-R (Poloyproplene randonCo-polymer) pipes laid in wall/ ceiling/ floor incl plain PP-R and brass threaded PP-R fittings or flanged jointsincl connecting up with existingsystem all as specified and directed . |
| 81 | S&F 25mm diameter 3- layered SDR 7.4 (PN-16) (outer green coloured UV stabilized, middle black coloured UV stabilized and inner most layer white coloured with antimicrobial properly)PP-R (Poloyproplene randonCo-polymer) pipes laid in wall/ ceiling/ floor incl plain PP-R and brass threaded PP-R fittings or flanged jointsincl connecting up with existingsystem all as specified and directed . |
| 82 | S&F 20mm diameter 3- layered SDR 7.4 (PN-16) (outer green coloured UV stabilized, middle black coloured UV stabilized and inner most layer white coloured with antimicrobial properly)PP-R (Poloyproplene randonCo-polymer) pipes laid in wall/ ceiling/ floor incl plain PP-R and brass threaded PP-R fittings or flanged jointsincl connecting up with existingsystem all as specified and directed . |
| 83 | Drilling and taping CI/ DI/ MS/ GI/ PP-R pipe water mains (in position) for branch connection of size 15mm/ 20mm/ 25mm complete all as specified. |
| 84 | S&F as in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 50mm bore as in repairs complete all as specified and directed by Engineer – in – Charge. |
| 85 | S&F as in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 40mm bore as in repairs complete all as specified and directed by Engineer – in – Charge. |
| 86 | S&F as in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 25mm bore as in repairs complete all as specified and directed by Engineer – in – Charge. |
| 87 | S&F as in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 20mm bore as in repairs complete all as specified and directed by Engineer – in – Charge. |
| 88 | S&F as in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 15mm bore as in repairs complete all as specified and directed by Engineer – in – Charge. |
| 89 | M&L Rubber gasket joint (push on tyton joint) suitable for 80mm bore spigot and socketed ductile iron pipecomplete all as specified and as directed by Engineer-in-Charge. |
| 90 | M&L Rubber gasket joint (push on tyton joint) suitable for 100mm bore spigot and socketed ductile iron pipecomplete all as specified and as directed by Engineer-in-Charge. |
| 91 | M&L Rubber gasket joint (push on tyton joint) suitable for 150mm bore spigot and socketed ductile iron pipecomplete all as specified and as directed by Engineer-in-Charge. |
| 92 | M&L Rubber gasket joint (push on tyton joint) suitable for 200mm bore spigot and socketed ductile iron pipecomplete all as specified and as directed by Engineer-in-Charge. |
| 93 | M&L Rubber gasket joint (push on tyton joint) suitable for 250mm bore spigot and socketed ductile iron pipecomplete all as specified and as directed by Engineer-in-Charge. |
| 94 | M&L Rubber gasket joint (push on tyton joint) suitable for 300mm bore spigot and socketed ductile iron pipecomplete all as specified and as directed by Engineer-in-Charge. |
| 95 | M&L Rubber or fibre board gasket joint suitable for 80mm bore flanged pipes and fittings including provision of bolts, nuts, washers and white lead or mineral oil complete all as specified. |
| 96 | M&L Rubber or fibre board gasket joint suitable for 100mm bore flanged pipes and fittings including provision of bolts, nuts, washers and white lead or mineral oil complete all as specified. |
| 97 | M&L Rubber or fibre board gasket joint suitable for 150mm bore flanged pipes and fittings including provision of bolts, nuts, washers and white lead or mineral oil complete all as specified. |
| 98 | M&L Rubber or fibre board gasket joint suitable for 200mm bore flanged pipes and fittings including provision of bolts, nuts, washers and white lead or mineral oil complete all as specified. |
| 99 | M&L Rubber or fibre board gasket joint suitable for 250mm bore flanged pipes and fittings including provision of bolts, nuts, washers and white lead or mineral oil complete all as specified. |
| 100 | M&L Rubber or fibre board gasket joint suitable for 300mm bore flanged pipes and fittings including provision of bolts, nuts, washers and white lead or mineral oil complete all as specified. |
| 101 | M&L PTMT float valve high pressure with polythene float and fly complete, screwed for Aluminium rod or PVC fenule and fixed in 15 mm bore all as specified and directed. |
| 102 | M&L PTMT float valve high pressure with polythene float and fly complete, screwed for Aluminium rod or PVC fenule and fixed in 20 mm bore all as specified and directed. |
| 103 | M & L for areacleaning of water supplyincluding clearing of vegitation, wild growth and trimming of grass etc in and around the water storage tanks, valve pits and installation compound and removing rubbish off the premises complete including spreading of suitable chemicals as approved for further growth of weeds and vegitation in the vicinity of installations complete all as specified and as directed. |
| 104 | M&L for Bacteriological/Chemical testing and analysis with preparation of detailed report as per IS 10500:1991 after collection of samples at various locations all as specified and directed by Engr-In-Charge.Note: (a) the testing will be conducted by Govt Approved Labs/NABL labs only (b) the contractor will make suitable arrangements for collection of sample water with prior intimation to Engr-in-Charge. (c) Test report should be submitted to the office by the Contractor. |
| 105 | S & F as in repairs PP-R Gate valves (brass insert) as per requirement of the site 63mm diameter all as specified and directed by Engineer - in – Charge . |
| 106 | S & F as in repairs PP-R Gate valves (brass insert) as per requirement of the site 50mm diameter all as specified and directed by Engineer - in – Charge . |
| 107 | S & F as in repairs PP-R Gate valves (brass insert) as per requirement of the site 32mm diameter all as specified and directed by Engineer - in – Charge . |
| 108 | S & F as in repairs PP-R Gate valves (brass insert) as per requirement of the site 25mm diameter all as specified and directed by Engineer - in – Charge . |
| 109 | S & F as in repairs PP-R Gate valves (brass insert) as per requirement of the site 20mm diameter all as specified and directed by Engineer - in – Charge . |
| 110 | S & F as in repairs DOL starter for induction motor capacity of 2 HP three phase, 415 V, 50 Hz as per specified and directed by Engr-in-charge. |
| 111 | S & F as in repairs automatic star delta starter suitable for 15 HP capacity motor, three phase, 415 v with IP54 extended wide band coil FRLS internal wiring air break, 15 HP, 11.5 kW contactor size 22 overload relay range 12 to 18 Amp all as specified and directed. |
| 112 | S & F as in repairs automatic star delta starter suitable for 10 HP capacity motor, three phase, 415 v with IP54 extended wide band coil FRLS internal wiring air break, 10 HP, 7.5 kW contactor size 18 overload relay range 25 to 30 Amp all as specified and directed. |
| 113 | S & F as in repairs automatic star delta starter suitable for 70/75 HP capacity motor, three phase, 415 v with IP54 extended wide band coil FRLS internal wiring air break, 75 HP, 55 kW contactor size 65 overload relay range 100 to 110 Amp all as specified and directed. |
| 114 | S&F as in repairs horizontal, multistage, end-section centrifugal pump with axial suction port radial discharge port 0.5/0.7 KW/HP single phase 220-240 Volts, minimum head 34 metre, minimum flow 3.1 cum/hr, RPM 2900, Rated current 3.1-2.8A, Enclosoure class (ICE 34-5) IP55, Pump materials in contact with the liquid are in high grade SS with miniumum efficiency index 70% with pressure controller for costant water pressure, incl pressure meter, pressure tank 24L for constant water, material SS 304 with incl complete GI fitting for fixing of pump with existing pipe inlet & outlet 25 mm bore incl PCC Work complete all as specified and directed. |
| 115 | S&F as in repairs water pressure tank (24 Litre)pressure pump working pressure-10kg,suitable as per existing tank size made out galvanized steelMale:-Aventura & equivalent make As per approved by GE. |
| 116 | S & F as in repairs Italtecnica PM/5G pressure relay to 5 bar 1.25 BP, a cap n code-PM/5G for pressure pump at Md Accn area all as specified and directed by Engineer - in – Charge. |
| 117 | Supply, installation, testing & commissioning as in repairs of Whole house water filtration system made from food grade material, suitable for removal of impurities such as silt, sand and other sediments from water. Water house filtration system shall be comprising of following sepcification and accessories.(a) Capable of filtration of impurities up to 5 micron from water.(b) High performance depth filtration, no electricity required.(c) FDA CFR-21 compliant.(d) In-built shut off valve.(e) Working pressure 1.7-6.9 bar.(f) Flow rate upto 170 LPM. |
| 118 | (g) Cartridge inclusion type.(h) Operating temperature (4 to 37.8⁰C)(j) Filter wriench to be provided for sump removale and cartridge changing.(k) One inch NPT inlet or outlet ports.Note:- (i) Make to be approved by GE out of the make/ brands fulfilling above listed parameters/ criteria. Contractor has to submit all relevant documents related to parameters/ criterria for approval of make prior to ordering bulk quantity.(ii) Quoted rate shall be inclusive of cuting of pipe for making connection with and including any type of GI/ CPVC/ UPVC fittings required for installation of the filter complete all as specified and directed. |
| 119 | S&F in replacement, mild steel clamp suitable for 100mm bore pipe made from 25x3mm flat iron including 20mm socket welded in the clamp including nuts and bolts and rubber sheet complete all as specified and as directed. |
| 120 | S&F in replacement, mild steel clamp suitable for 150mm bore pipe made from 25x3mm flat iron including 20mm socket welded in the clamp including nuts and bolts and rubber sheet complete all as specified and as directed. |
| 121 | S&F in replacement, mild steel clamp suitable for 200mm bore pipe made from 25x3mm flat iron including 20mm socket welded in the clamp including nuts and bolts and rubber sheet complete all as specified and as directed. |
| 122 | S & F in repair bib taps 15mm bore cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified and directed by Engineer - in – Charge . |
| 123 | S&F as in repairs 25mm dia Brass NRVscrewed type complete all as specified and as directed. |
| 124 | S&F as in repairs 20mm dia Brass NRVscrewed type complete all as specified and as directed. |
| 125 | S&F as in repairs 15mm dia Brass NRVscrewed type complete all as specified and as directed. |
| 126 | M&L Cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate for foundations, mass and for repairing to paths/ road & hardstanding etc. including necessary cutting of roads/ paths for passing of pipes and making good the disturbed portion complete all as specified and directed by Engineer – in - Charge. |
| 127 | S & F as in replacement rotational moulded polythene water storage tanks, triple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres all as specified and directed by Engineer - in - Charge . |
| 128 | S & F as in replacement rotational moulded polythene water storage tanks, triple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 1000 Litres all as specified and directed by Engineer - in - Charge . |
| 129 | Supplying and laying as in repairs of uPVC, Class-III, 6 Kgf per Sqcm,65 mm inner diameterand laying in wall/ceiling or laying in floor including fittings complete all as specified and as directed. |
| 130 | S&F as in replacement 65mm dia uPVC ball valve omplete all as specified and as directed. |
| 131 | S & F as in replacement mechanical collar suitable for DI pipe line 100 mm bore size complete all as specified and directed. |
| 132 | S & F as in replacement mechanical collar suitable for DI pipe line 150 mm bore size complete all as specified and directed. |
| 133 | S & F as in replacement mechanical collar suitable for DI pipe line 200 mm bore size complete all as specified and directed. |
| 134 | S & F as in replacement mechanical collar suitable for DI pipe line 250 mm bore size complete all as specified and directed. |
| 135 | S & F as in replacement mechanical collar suitable for DI pipe line 300 mm bore size complete all as specified and directed. |
| 136 | Supply and laying as in repairs straight plain brass ferrule, screwed both ends for iron pipe for 20mm bore complete all as specified and directed. |
| 137 | Supply and laying as in repairs straight plain brass ferrule, screwed both ends for iron pipe for 25mm bore complete all as specified and directed. |
| 138 | S & F as in replacement mechanical collar \"D\"joint suitable for DI pipe line 100 mm bore size complete all as specified and directed. |
| 139 | S & F as in replacement mechanical collar \"D\"joint suitable for DI pipe line 150 mm bore size complete all as specified and directed. |
| 140 | S & F as in replacement mechanical collar \"D\"joint suitable for DI pipe line 200 mm bore size complete all as specified and directed. |
| 141 | S & F as in replacement mechanical collar \"D\"joint suitable for DI pipe line 250 mm bore size complete all as specified and directed. |
| 142 | S & F as in replacement mechanical collar \"D\"joint suitable for DI pipe line 300 mm bore size complete all as specified and directed. |
| 143 | Supply and installation as in replacement Retro Reflective Sign Boards for water supply installation of size 5\"0\" x 4\"0\" (print area) as per the following specifications:(a) Post (pillar type) 55 mm dia 2 mm thickness SS 304 grade 9.5 feet long - 02 Nos fittted with MS base plate 150 mm x 150 mm x 5 mm thickness at the bottom and 50 mm dia SS half balls on the top. (b) Pipe for print area frame using 32 mm dia 1.2 mm thickness SS 304 Grade pipe and 06 Nos connecting pipes of 50 mm length.(c) SS rivetted strip 2 mm thickness and size 30 mm length & 25 mm width- 16 Nos.(d) 3 mm thick ACP sheet (Aluminium composite sheet) of size 4 feet x 5 feet along with 1 mm thickness retro reflective material for approved colour and writing work in capital letters and numbers/ photographs on both sides of ACP sheet all as specified and directed by Engr-in-charge.(e) PCC 1:2:4 type B-1 block of size 300 mm x 300 mm x 450 mm - 02 Nos for grouting of sign board incl earth work complete all as specified and directed. |
| 144 | Supply and installation as in replacement of Retro Reflective Sign Boards of size 5\"0\" x 4\"0\"of 3 mm thick ACP sheet (aluminium composite sheet)with 1 mm thickness retro reflective material for approved colour and writing work in capital letters and numbers/ photographs on one sides of ACP sheet for water supply installation all as specified and directed by Engr-in-charge. |
| 145 | M & L for preparing old painted steel surfaces of over 10 cm in width or girth and applying two coat of synthetic enamel paint applying by spray gun over exixting LT Panel/ Pipes/ Iron Angle/ MS Sheet installed at different EM installation as per the colour standard specified by the Engineer-in-Charge. |
| 146 | S & F as in repairs DOL starter for induction motor capacity of 5 to 7.5 HP three phase ,415 V, 50 Hz as per specified and directed by Engr-in-charge. |
| 147 | Repair & servicing of control card of soft stater of capacity 175 KW which includes assessment through visual inspection, diagnostic test to identify the cause of malfunction, checking of voltage level, current flow, checking fault in thyistors, damaged PCB components, loose connection, incorrect settings etc including repairing and refixing the same to its original position and testing for its functioning complete all as specified and directed. |
| 148 | Repair & servicing of control card of soft stater of capacity 90 KW which includes assessment through visual inspection, diagnostic test to identify the cause of malfunction, checking of voltage level, current flow, checking fault in thyistors, damaged PCB components, loose connection, incorrect settings etc including repairing and refixing the same to its original position and testing for its functioning complete all as specified and directed. |
| 149 | Repair & servicing of control card of soft stater of capacity 75 KW which includes assessment through visual inspection, diagnostic test to identify the cause of malfunction, checking of voltage level, current flow, checking fault in thyistors, damaged PCB components, loose connection, incorrect settings etc including repairing and refixing the same to its original position and testing for its functioning complete all as specified and directed. |
| 150 | Repair & servicing of control card of soft stater of capacity 55 KW which includes assessment through visual inspection, diagnostic test to identify the cause of malfunction, checking of voltage level, current flow, checking fault in thyistors, damaged PCB components, loose connection, incorrect settings etc including repairing and refixing the same to its original position and testing for its functioning complete all as specified and directed. |
| 151 | Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed. |
| 152 | Design, fabricate, supply, installation, testing and commissioning in replacement of indoor type dust proof & vermin proof cubicle panel board compartmentalized with seperate bus and cable alley chambers suitable for 3 phase, 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory (Manufacturer possessing CPRI test report for equivalent ratings)having modern fabrication facilities, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad-locking facility. |
| 153 | Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mmx50mmx6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards(02 Nos) LT 415/440 Volts, and manufacturer\"s name plate shall be riveted on external doors of feeder pillar box. |
| 154 | The size of panel board shall not be less than 1200mm x 850mm x 450mm (outer dimensions)for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity including taking down old unserviceable LT Panel complete all as specified and directed with and incl the followingBus Bar :-(a) 3 Phase 4 wire copper bus bars of suitable length & section not less than 30 x 10mm covered with coloured heat shrinkable anti track insulation tape of make Denson/ M-seal or equivalent of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm- 01 set. |
| 155 | Indication devices:-(a) Multifunction digital meter compatible to measure current, voltage, power factor & frequency with 3 lines LCD display in 96 x 96 sqmm flush mounted case, accuracy class 1.0 - 01 No.(b)Resin cast CT 250/5A cast resin base – 01 set of 03.(c)LED type phase indicator lamp RYB – 02 set of three(d) On/Off push buttons - 04 andselector switches - 02 Nos complete all as specified and directed.Incoming :-(a) I/C fast acting Semiconductor Fuse 250 A - 03 Nos(b)MCCB 3 pole, 200 Amps, 415 volts, 50 Hz, Ics = 100% Icu of breaking capacity 36 kA, adjustable thermal & fixed magnetic release type - 01 No(c) Line contactor, AC 3 duty, 415 Volts, 50 Hz, 185 Amps-01 No.(d) Control Transformer copper wound of suitable capacity- 01 No |
| 156 | Outgoing :-(a) Digital soft starter suitable for 60 HP motor,3 phase,415 Volts - 01Nos(b) MCB TP 32 Amp C curve - 01 Nos(b) Capacitor duty contactor,3 phase,415 volts,50 Hz,of rating12.5 kVAr – 2 Nos(c) Capacitor duty contactor,3 phase,415 volts,50 Hz,of rating 8.5 kVAr – 2 Nos(d) Power factor capacitor, ultra heavy duty advanced APP technology, 3 phase, 440 volt, 50Hz of rating 10 KVAR - 02 Nos(e) Power factor capacitor, ultra heavy duty advanced APP technology, 3 phase, 440 volt, 50Hz of rating 5 KVAR - 02 NosNote :(i) All existing and new connections of incoming/ outgoing cables shall be done through appropriate size of copper thimbles. |
| 157 | (ii) Factory made name plates with feeder names / Bldg Nos shall be fixed on relevant incomer / outgoing MCCB doors. (iii) The Contractor shall submit set of all drawings of the L.T. Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing. However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail