|
| 1 | Supply & Fixing of punched barb tape (SRPBT) Aluminium basehelix coil with and including necessary GI fixing clips for securing concertina coil 600 mm dia (in stretched position) hot dip galvanized steel wire coated with CLR anti corrosive paint making complete all as specified and as directed with following specification:- (i) Dia of coil (unstretched) - 600 mm (ii)No circles - 20 turns per coil(iii) Strech of each coil - 6 RM (iv) Central core wire - made from 3.15 mm dia GI - H.T.S.S wire as per IS : 4454 galvanised as per IS : 2629(v) Razor PUNCHED STRIP Razor punched tape is CONSEC -ZAL steel comprising of aluminium base with Zinc alloy @ 150 gm/Sqm comfirming to ASTM A -792/12-792M with additional primer treatment of Epoxy/POLYRETHANE & final print top coat of caulified green shade (BSL 139) by Hot dipping process. NOTE :- Quoted Rate deemed to be included cutting and jointin of concertina coil 600 mm dia for fixing onIPSS POLE upto heitht of 9 Mtr ertical/horizontal, cutting and jointin of concertina coil 600 mm dia for fixing on pole. |
| 2 | Supply & Fixing of punched barb tape (SRPBT) Aluminium basehelix coil with and including necessary GI fixing clips for securing concertina coil 1000 mm dia (in stretched position) hot dip galvanized steel wire coated with CLR anti corrosive paint making complete all as specified and as directed with following specification:- (i) Dia of coil (unstretched) - 1000 mm (ii)No circles - 20 turns per coil(iii) Strech of each coil - 8 RM (iv) Central core wire - made from 3.15 mm dia GI - H.T.S.S wire as per IS : 4454 galvanised as per IS : 2629(v) Razor PUNCHED STRIP Razor punched tape is CONSEC -ZAL steel comprising of aluminium base with Zinc alloy @ 150 gm/Sqm comfirming to ASTM A -792/12-792M with additional primer treatment of Epoxy/POLYRETHANE & final print top coat of caulified green shade (BSL 139) by Hot dipping process. NOTE :- Quoted Rate deemed to be included cutting and jointin of concertina coil 1000 mm dia for fixing onIPSS POLE upto heitht of 9 Mtr ertical/horizontal, cutting and jointin of concertina coil 1000 mm dia for fixing on pole. |
| 3 | S&F Galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins or clips as directed (each line wire to be measured). |
| 4 | Demolition of brick masonry built in CM complete all as specified and directed by Engr-in-charge. |
| 5 | M&L for brick work with sub class \"B\" bricks (using old size bricks), straight or curved on plan, exc 6M mean radius, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 6 | M&L for 15 mm thick cement plaster in cement mortar 1:4 on fair faces of concrete or brick surface and finished even and smooth without using extra cement with and including water proofing compound complete all as directed and specified. |
| 7 | M&L forpreparation of new plastered surfaces of Wall and applying two coats of weather proof exterior emulsion paint in normal pattern , over a coat of primeras per manufacturers instructions complete all as specified and as directed. |
| 8 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanks, fixing of barbed wire or concertina coil upto height of 9 mtrsand similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 9 | Preparation of new painted steel surfaces of any description, over 10 cm width or girth, not otherwise Sqm described and applying two coat of synthetic enamel paint.over a coat of red oxide etc. complete all as specified directed. |
| 10 | Taking down GI pipe of any grade of 15mm bore including fittings complete all as specified and directed. |
| 11 | Taking down GI pipe of any grade of 20mm bore including fittings complete all as specified and directed. |
| 12 | S&F steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 15mm complete all as specified and directed. |
| 13 | S&F steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 20 mm complete all as specified and directed. |
| 14 | Dismantling floor,hearth or wall tiling including cement mortar bedding and removing rubbish off the premisescomplete all as specified and as directed |
| 15 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and Sqm getting out in hard/dense soil complete all as specified and directed. |
| 16 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 17 | M&L for Cement concrete type D2 1:4:8 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed. . |
| 18 | Supply only Integral water proofing compound (ISI marked) |
| 19 | M&L for spreading and levelling of soil in layer n.exc 25cm thick including well ramming incl watering all as specified and directed by Engr-in-Charge |
| 20 | M&L for 75mm thick P.C.C 1:4:8 type D-2 (using 40mm graded stone aggregates) as in sub base of fioor complete all as Sqm specified and directed . |
| 21 | M&L Broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed . |
| 22 | M&L for plain cement concrete PCC 1:2::4 type B-2 using 40 mm graded stone aggregate as in plinth protection, path/hardstanding /subbase etc complete all asspecified and as directed |
| 23 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 24 | M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigment complete all asspecified and as directed |
| 25 | M & L for 25 mm thick PCC 1:2:4 type B1, using 20 mm graded stone aggregate as in flooring including finishing cement concrete rough surface with out using extra cernent complete all asspecified and as directed . |
| 26 | M & L for non skid coloured ceramic tiles 7 to 8mm thick square / rectangular area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in floor laid over 15 mm thick screed bed in CM 1:6 . set and jointed in neat cement slurry and pointed in coloured cement to match the surface of tile complete all as specified and directe . |
| 27 | M & L for Glazed ceramic coloured tiles of size 300 mm X 200 mm X 7 mm thick as on vertical surfaces such as skirting, dados and rises to steps etc over 10mm thick screed bed in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed |
| 28 | M & L for 12 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and smoth without using extra cement complete all as specified and directed. |
| 29 | M&L for two coats of distemper oil emulsion over newely plastered surfaces of wall including preparation of surfaces complete all as specified and directed. |
| 30 | M & L for preparing newly plastered or previously untreated walls surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 31 | Returning filling in including speading, leveling, watering and well ramming in layers not exc 25 cm in soils complete ali as specified and directed by Engr-in-Charge |
| 32 | Removing of surplus excavated Soii n-exc 50m and depositing where directed at a level Cum n.exc 1.50m above the starting point complete all asspecified and as directed . |
| 33 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregates) as in plinth protection, finishing even and smooth without using extra cement complete all as specified and directed by Engr- in-Charge |
| 34 | M & L for plain cement concrete M-15 Nominal Mix (1:2:4) type B-1 (using 20 mm graded stone aggregate), as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth course, string courses, lacinng courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 35 | M & L for providing pre-cast cement concrete landing, cover slabs (for man holes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate and setting in cement mortar 1:6 complete all as specified and directed. |
| 36 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 37 | M & L for mild steel TMT bars upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed |
| 38 | use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, bands, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished flat surface of concrete complete all as specified and directed. |
| 39 | use & waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), fair finished surface complete all as specified and directed |
| 40 | M&L RCC M-25 Design Mix, using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 41 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames not exceeding 1.5 Sqm each and removing from site complete all as specified and directed. |
| 42 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube fixed in opening as per specification and shown in drg in SSR Part -II 2020 complete all as specified and as directed |
| 43 | S&F factory made solid panel PVC door moulded shutter 30mm thick consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain cover PVC C channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement as per specification and drg shown in SSR Part-II 2020 complete all as specified and as directed |
| 44 | S&F 300mm long stainless steel finished sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete all as specified and as directed |
| 45 | S&F stainless steel finished butt hinges cold rolled medium weight of size 100mm complete as specified and as directed. |
| 46 | S&F 150 mm long stainless steel finished barrel tower bolt of extruded section complete all as specified and as directed |
| 47 | S&F 150 mm long stainless steel finished handle fabricated type complete all as specified and as directed |
| 48 | S&F Framed work such as grills, gratings, etc. for window with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed |
| 49 | M&L for two coats of synthetic enamelled paint over a coat of red oxide primer on new steel surfaces exc 10cm width or girth including preparation of surfaces.complete all as specified and directed by Engr In Charge. |
| 50 | S&F tripple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part 1 of 1000 Ltrs capacity complete all as specified and directed |
| 51 | S&F 20mm bore ball valve high pressure of PTMT with epoxy coated alluminium rod and high density plastic ball secrewed for iron pipe and fixed (Minimum wt 15 mm 142 grns/20 mm - 210 gms) complete all as specified and as directed |
| 52 | S&F 15 mm dia of pipe Gun-metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed completo all as specified and directed by Engr In Charge. |
| 53 | S&F 20 mm dia of pipe Gun-metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed.complete ali as specified and directed by Engr in Charge. |
| 54 | S&F vitreous china wash down water closet pan with seat cover plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device (excluding fixing bolts, flushing cistern and flush pipe) etc complete all\"as specified and as directed. |
| 55 | S&F vitreous china urinal full stall type flat back size of white with grating and union for discharge pipe including chromium plated water spreader, connection. pipe and discharge down pipe complete all as specified and as directed |
| 56 | S&F for Wash Hand basins, Vitreous China, white, flat back, size 550x440mm, including cutting for and pinning in ends of brackets or erecting stand, angle bracket (but exclusive of fixing of supply, waste pipe, taps) complete all as specified and directed. |
| 57 | S&F PVC valveless, syphonic action type, 10 Itr flushing cistern, low level (dual flush), white, with inlet, bail valve, float and handle including brackets, CP down pipe and connecting to the WC and making good to the floor with PCC all as specified and directed. |
| 58 | S&F bib taps 15mm dia fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed. complete all as specified and directed by Engr In Charge. |
| 59 | S&F 15mm dia stop valves, fancy type chromium plated, screwed down, screwed both ends for iron pipe or for unions and fixed. complete all as specified and directed by Engr In Charge. |
| 60 | Supply & fixing 15mm pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered \"Hot\" or Cold\" with long screwed shanks and fly nuts, screwed for iron pipe and fixed. Bore of pipe in 15mm complete all as specified and directed by Engr In Charge |
| 61 | S&F for waste coupling of PTMT for 32 mm bore dia of discharge pipe (half or full Each threaded) Minirnum weight 32mm-45gms/40 nm-60 gms) complete all as specified and directed |
| 62 | S&F PVC connections\" 15mm size with PTMT nuts of length 600mm complete all as specified and directed |
| 63 | S&F urinal spreader of PTMT 15mm size with PTMT nuts of length 300mm complete all as specified and directed by Engr-in-Charge |
| 64 | S&F cast iron floor trap 75mm out let dia with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4). complete all as specified and directed. |
| 65 | M & L for Gully traps salt glazed stoneware (SGSW) square or round mouthed type \"P\" of size 180x100mm for drain pipes complete all as specified and directed. |
| 66 | S & F 75 mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in tenches or in floors complete all as specified and directed |
| 67 | S & F 110 mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in tenches or in floors complete all as specified and directed |
| 68 | S & F 75 mm dia bore PVC (SWR) bends any radius complete all as specified and directed |
| 69 | S & F 110 mm dia bore PVC (SWR) bends any radius complete all as specified and directed |
| 70 | S & F 110 mm dia bore PVC (SWR) junction single \"T\" equal or unequal complete all as specified and directed |
| 71 | S&F PVC (SWR) 110 mm bore vent cowl complete all as specified and directed |
| 72 | S&F soap dish vitreous china white, approximate size 160x160x90mm embedded in the wall. complete all as specified and directed |
| 73 | S & F of 20 mm dia Aluminium anodised tubular towel including one pair of fixing brackets complete all as specified and directed. |
| 74 | Demolition of brick masonry built in CM complete all as specified and directed by Engr-in-charge. |
| 75 | S&F for 150 mm dia reiforced concrete pipe, class NP-2, drain pipes laid in trenches and jointed with collars all as specified and directed. |
| 76 | M&L for Concrete bed in 1:4:8 type D2 to drain pipes 150 mm incl packing under,and hunching against the sides after they are laid and tested complete all as specified and as directed. |
| 77 | Cutting into existing manholes for 150mm dia of pipe for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed |
| 78 | S&F in repair vitreous china urinal full stall type flat back size of white with grating and union for discharge pipe including chromium plated water spreader, connection pipe and discharge down pipe complete all as specified and as directed |
| 79 | S&F in repair 10 Itr capacity PVC valueles, syphonic action type, flushing cistern top level, white with inlet, ball valve, float and handle inc! bracket 32mm dia flush pipe etc complete complete all as specified and directed |
| 80 | S&F in repair CP health faucet with 1.5 m PVC connection as in repairs complete Each all as specified & directed. |
| 81 | M&L in repair On site LLDPE septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 50 users conventional type including excavation and refilling with same void ratio before excavation and having capacity not less than 5000 Lires compiete all as specified and as directed |
| 82 | M&L in repair factory made perforated precast RCC Manhole cover 75mm thick any size incl 1mm MS Sheet all around the cover (incl placing)complete all as specified and directed by Engr-In-Charge.. |
| 83 | M&L cement concrete Type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) in kerb stone,copings,, apex stones,, anchorage biocks,, etc. (of any section as directed), with plain fair faces, including chamfered weatherings, throating etc complete al! as specified and as directed. |
| 84 | S & F in repairs 600mm X 450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. |
| 85 | Deduct Schedule of Credit of Rs 2225.00 as brought out from serial page No 36 of tender |