|
| 1 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driverwith IP 65/66 protection and system efficiency >120Lm/W complete all as specified and directed.Make : Crompton cat pt No CRP-421-70-57-SL-LM-NSG or equivalent in make of Havells/Bajaj/Magik |
| 2 | Supply and fixing LED flood light 100 watt 230 V AC outdoor type made of pressure die cast aluminium housing with toughened glass with SMD LEDs and IP65 and system efficiency >120Lm/W complete all as specified and directed.Make : Crompton cat pt No TFS-522-100-30-NL-SL-NS-GL-NSG or equivalent in make of Havells/Bajaj |
| 3 | Supply and fixing25watt LED post top lantrerns fittings made in Iron, housing with decorative clear acrylic diffuser and IP 65 protection with and including LED lamp and all necessory electric connection withfrom junction box to post top lantern complete all as specified and as directed. |
| 4 | S & F M.S. Fabrication work consisting of wire mesh, M.S. Angle squire pipe, Flate etc duly cut into shape and size to fabricate cage for Post top lanterns mounted on boundary wall complete as specified and as directed by Engr-in-charge including grouting on wall, one coat of red oxide meteal primar and two coats of synthetic enamel paint complete all as specified and directed. |
| 5 | S&F GI bracket on street light pole/ boundary wall for post top lantern made of 40 mm dia light grade GI pipe including fixing clamps, nuts and bolts,/cement work and painting with two coats of aluminium paint over a coat of red oxide metal primer complete for maximum length of 1.20mtr complete all as specified and as directed. |
| 6 | Supply installation and erection in trench vertical position steel tubular swaged welded poles complete with MS base plate of 6mm thick of size 450mmx450mm finial taper plug pole cap, bolts, nut and screwed pole made out of ERW MS tubing conforming to IS 2713 Part II of 09 mtr long 410, SP-55 incl drilling of holes of required size of nos for fixing of cross arms bracing support /taking out of cables etc, with inbuilt junction box for 3 phase 4 wire AC supply and painting of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concrete complete all as specified and as directed |
| 7 | S & F Cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, in any shape or size as indicated or directed and including applying two coats of aluminium paint over a coat of red oxide primer and Anit climbing device comprising 2.24mm dia Galvanised Steel 2 strand barbed wire with 2mm dia barbs wrapped spirally round poles complete all as specified and directed. |
| 8 | M&L for stay assembly rod 20mm dia complete with accessories as shown in Electrical plate No 1 (Loop type insulator , stay clamps, excavation and concrete measured separately) complete all as specified and directed. |
| 9 | M&L for Plain cement concrete ( 1:4:8)type D-2 (using 40mm graded crushed stone aggregates) as in foundation of poles etc complete all as specified and directed. |
| 10 | Materials and labour forplain cement concreate (1:3:6) type C2 (using 40 mm graded stone aggregrate) as in foundations filling, coping for poleand mass concreate filling of trench across the road etc. complete all as specified and as directed. |
| 11 | M&L for Plain cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in coping of poles complete all as specified and directed. |
| 12 | S&F thermoplastic street light junction box, weather proof having ingress protection level IP-66 and size L(254-255mm)x B (180-205mm)x H(111-112mm) dually fixed with Aluminium flat clamp and support made of 25mmx3mm/Flush in existing wall, duly painted with aluminium paint over a coat of red oxide metal prmer complete (including 1 no 5 way cable connector suitable to connect 16 Sqmm Aluminium cable 3 nos polymide cable gland having sealing range 17-25 mm complete with 1 no 19 mm PVC blend) complete all as specified and directed. |
| 13 | Supply and laying steel tubing GI light grade for cable protection passing under road/floor or for fixing to poles all as spd and directed of size 80mm bore complete all as specified and directed.Make : Jindal/Zenith/TATA or equivalent make as approved by GE |
| 14 | Supply and laying steel tubing GI light grade for cable protection passing under road/floor or for fixing to poles all as spd and directed of size 40mm bore complete all as specified and directed.Make : Jindal/Zenith/TATAor equivalent make as approved by GE |
| 15 | Supply and laying for under ground heavy dutyXLPE insulated, armouredaluminium conductor cable1100 volts grade, cross-sectional area 25 sq. mm 3.5 corein trenchches / through pipe or bare in road crossing / plingth/ drain/ duct/ floor along pole/ wall /ceillings etccomplete all as specified and directed. Note:- Earth work, bricks protection sand cuisioning shall be measured and paid seperately. |
| 16 | Supply and laying for under ground heavy dutyXLPE insulated, armouredaluminium conductor cable1100 volts grade, cross-sectional area 16 sq. mm 4.0 corein trenchches / through pipe or bare in road crossing / plingth/ drain/ duct/ floor along pole/ wall /ceillings etccomplete all as specified and directed. Note:- Earth work, bricks protection sand cuisioning shall be measured and paid seperately. |
| 17 | Cutting existing metal/bituminus road/PCC walk way/any type of tile worksn.exc 0.45m width and n.exc 0.90 m in depth including all connected earth work and making good disturbed surfaces matching with the existing specification and finish including disposal of surplus material to a distance n.exc 50m complete all as specified and as directed. |
| 18 | Supply and fix 6KW, 3 phasecapacity timer streeet light controller panel complete all as specified and directed. |
| 19 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth for foundationor for laying of cable , fixing of poleetc and getting out in soft/loose soil, old serviceable bricks etc complete all as specified and as directed. |
| 20 | Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed. |
| 21 | Removing excavated soil to a distance not exceeding 50 metre anddepositing where directed at a level , not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 22 | Materials and labour for sand filling 23 cm thick above thecable with approved quality coarse sand for sand cushioning of under ground cableincludingspreading and punning down to desired thickness of 18 cm complete all as specified and as directed. |
| 23 | Supply and laying for burnt brick sub class \"B\" locally available best quality laid in trenches for protections of under ground cable complete all as specified and as directed. |
| 24 | Supply, installatioin, commissioning and testing of Tower Air Condtioner of 2.0 TR (6000 Kcal/Hr) capacity, Digital inverter type, complete with cordless remote control unit with LCD/LED display with 5 star rating or above and EER of 3.2 and above. Indoor unit floor Standing type suitable for 230 volts, 50 Hz, single phase AC supply and capable of performing the function as cooling , heating, air circulating and filtering. Outdoor unit of the air conditioner shall be fitted with discharge cool type rotary/ scroll compressor operating on non-CFC refrigerants R-32 with over load protection and mounted on resistant mountings for quite operation. Remote cordless controlshall be provided with ON/OFF timer, fan speed selector (min 3 speed), mode selector (cooling/fan) and setting -up of temperature. Display of temperature and mode shall be provided on indoor unit and on handset. Overall power factor of the unit shall not be less than 0.85 at operating conditions. Note :- The installation shall include mounting/ fitting indoor and outdoor unit at respective locations. Laying refregerent piping, extension of drain pipeupto 6 mtr length and connecting both units after drilling holes, putting PVC sleeve, sealingand finshing the same duly matched with adjoining surface. Refrigerant pipeshall be insulated with expanded polythylene foam not less than 5 mm thick.Leak testing of the entire system after installationto be carried out. Rate quoted will include Charging refrigerant gas in the unit, suitable electric connection between indoor and outdoor unitand upto switchMake : VOLTAS/ HITACHI /SAMSUNG or equivalent make as approved by GE |
| 25 | Supply, installatioin, commissioning and testing of Split type Air Condtioner of 1.5 TR (4535 Kcal/Hr) capacity, Digital inverter type, complete with cordless remote control unit with LCD/LED display, 5 star rating and EER of 3.2 and above. Indoor unit Hi wall mounted type suitable for 230 volts, 50 Hz, single phase AC supply and capable of performing the function as cooling , heating, air circulating and filtering. Outdoor unit of the air conditioner shall be fitted with discharge cool type rotary/ scroll compressor operating on non-CFC refrigerantswith over load protection and mounted on resistant mountings for quite operation. The filters packs provided shall be washable. Remote cordless controlshall be provided with ON/OFF timer, fan speed selector (min 3 speed), mode selector (cooling/fan) and setting -up of temperature. Display of temperature and mode shall be provided on indoor unit and on handset. Overall power factor of the unit shall not be less than 0.85 at operating conditions. Note :- The installation shall include mounting/ fitting indoor and outdoor unit on wall with suitable bracket etc. at respective locations. Laying refregerent piping, extension of drain pipeupto 6 mtr length and connecting both units after drilling holes, putting PVC sleeve, sealingand finshing the same duly matched with adjoining surface. Refrigerant pipeshall be insulated with expanded polythylene foam not less than 5mm thick.Leak testing of the entire system after installationto be carried out. Rate quoted will include Charging refrigerant gas in the unit, suitable electric connection between indoor and outdoor unit and upto switch. Make : VOLTAS/ HITACHI / SAMSUNG or equivalent make as approved by GE |
| 26 | M&L for modular metal flush box 2 moduleone omplete all as specified and directed. |
| 27 | M&L for modular white cover plate with frame 2 modulecomplete all as specified and directed. |
| 28 | M&L for modular white cover plate with frame 3 modulecomplete all as specified and directed. |
| 29 | M&L for modular metal flush box 3 moduleone omplete all as specified and directed. |
| 30 | S & F modular type mini MCB 32Amp SP C Series 3KA white complete all as specified and directed. |
| 31 | S & F modular type 25 A Motor starters white colour complete all as specified and directed. |
| 32 | S & F modular type 10/25A 3 Pin Shuttered Socket white colour complete all as specified and directed. |
| 33 | S&F 25A 3 pin plug top complete all as specified and directed. |
| 34 | Material and labour for circuit/sub-main wiringwith two run of 1100 V gradePVC insulated & unsheathed 6.0 Sqmm single core multi stranded copper conductor cable alongwith one run of6.0 Sqmm 1100 V grade FRLSH PVC insulated & unsheathed single core multi stranded copper conductor cable for earth continuity conductor connected to common earth dolly, drawn throughconcealed PVC conduit complete all as specified and as directed. Note : (i) Three runs of 6.0 Sqmm cable shall measured as one length.(ii) Cutting chases, pinning in, making good to facings etc shall be included in sub-main wiring. Make : Polycab/KEI/Havells or equivalent make as approved by GE |
| 35 | Supply and laying out of copper refregerent pipe 5/8\" dia with PUF insulation as per required length at site complete with brazing and flaring nuts of suitable size (brass) complete all as specified and directed. |
| 36 | Supply and laying out of copper refregerent pipe 1/4\" dia with PUF insulation as per required length at site complete with brazing and flaring nuts of suitable size (brass) complete all as specified and directed. |
| 37 | Supply and laying out of suitable size of drain out pipe of indoor unit of Split AC completeall as specified and directed. |
| 38 | Supply and fixdecorative five star rated with brushless direct current motor (BLDC) ceiling fans 1200 mm sweep complete with blades, down rods, electronic regulator and accessories, 230 V, min air delivery 245 CFM complete all as specified and directed. Make: Havells Cat No FHCLB5SPWT48 or equivalent in make of Bajaj/Usha/Crompton as approved by GE |